1.Meta-analysis of the clinical efficacy and safety of Jianwei xiaoshi oral liquid in the treatment of functional dyspepsia in children
Ping RONG ; Guiyun PAN ; Juan WEI ; Tengda LI ; Xilian ZHANG
China Pharmacy 2025;36(7):867-873
OBJECTIVE To evaluate the clinical efficacy and safety of Jianwei xiaoshi oral liquid in the treatment of functional dyspepsia (FD) in children, and provide evidence-based basis for clinical use of the drug. METHODS Retrieved from CNKI, VIP, Wanfang, CBM, Cochrane Library and PubMed, randomized controlled trials (RCTs) about Jianwei xiaoshi oral liquid in the treatment of FD in children were collected from the inception to Apr. 2024. The control group was treated with conventional western drugs (including gastrointestinal motion-promoting, antacids or acid-suppressing drugs), and the trial group was treated with Jianwei xiaoshi oral liquid alone or combined with conventional Western drugs (drug dosage and course of treatment were the same as the control group). Meta-analysis was performed using RevMan 5.3 software after quality evaluation with the Cochrane risk bias assessment tool 6.1. RESULTS Totally 16 literature were employed which included 1 962 patients. The results of meta-analysis showed that the total clinical effective rate of Jianwei xiaoxi oral liquid in the treatment of FD in children of trial group was significantly higher than that of the control group [RR=1.18, 95%CI (1.13, 1.22), P<0.000 01]. In this study, subgroup analysis was conducted on the usage and dosage, course of treatment, and combination or not in trial group, as well as the type of conventional Western drugs. The results showed that the total clinical effective rate of trial group was significantly higher than that of control group; the relief time of abdominal distension and abdominal pain in trial group [MD=-2.54, 95%CI (-3.10, -1.98)], loss of appetite relief time [MD=-2.12, 95%CI (-2.63, -1.61)], nausea and vomiting relief time [MD=-1.70, 95%CI (-2.27, -1.14)], and belching relief time [MD=-1.61, 95%CI (-2.44, -0.78)] were shorter than that of the control group significantly (P<0.05). In addition, compared with control group, the levels of gastrin [SMD=1.63, 95%CI (0.98, 2.29)] and motilin [SMD=2.06, 95%CI (1.58, 2.54)] as well as gastric antral emptying rate [MD=5.99, 95%CI (2.78, 9.21)] in trial group were increased significantly, while the level of somatostatin was decreased significantly [SMD=-1.30, 95%CI (-1.57, -1.02)] (P≤0.000 3). CONCLUSIONS Jianwei xiaoshi oral liquid, whether used alone or in combination with other medications, and regardless of the treatment course or dosage and usage, is effective in treating FD in children, with good safety.
3.Experimental validation of the accuracy of reported dose-length product values in different CT scanner models
Bin YANG ; Shicai ZHANG ; Xiankai HUO ; Zhenhe LIU ; Pengcheng WANG
Chinese Journal of Radiological Health 2025;34(2):155-160
Objective To evaluate the accuracy of dose-length product (DLP) values in CT dose reports by comparing them with the DLP values measured using a pencil-type ionization chamber. Methods Experiments were conducted using four CT scanners with different detector row numbers from two manufacturers (A and B), along with a head phantom and a pencil-type ionization chamber. Other scanning parameters were fixed, while pairwise combinations of kV and mAs were tested. The DLP values were measured under various scanning conditions using the pencil-type ionization chamber (DLPmeasured) and the corresponding DLP values in CT dose reports were recorded (DLPreported). All data were subjected to statistical analysis. Results Differences were observed between DLPreported and DLPmeasured values. The smallest mean absolute value of ΔDLP was approximately 2.526 mGy·cm observed on the 40-row CT scanner of manufacturer A. There was a difference between the ΔDLPs of the four CT scanners. Both DLPreported and DLPmeasured exhibited a linear relationship with mAs. Conclusion The percentage errors between DLPreported and DLPmeasured values for all four CT scanners were within the national standard tolerance of 15%. DLP values in CT dose reports can serve as a reference for assessing patient radiation dose during scanning. However, for radiation dose-related research, data measured using dosimetric instruments such as pencil-type ionization chamber are recommended.
4.Transfer learning enhanced graph neural network for aldehyde oxidase metabolism prediction and its experimental application.
Jiacheng XIONG ; Rongrong CUI ; Zhaojun LI ; Wei ZHANG ; Runze ZHANG ; Zunyun FU ; Xiaohong LIU ; Zhenghao LI ; Kaixian CHEN ; Mingyue ZHENG
Acta Pharmaceutica Sinica B 2024;14(2):623-634
Aldehyde oxidase (AOX) is a molybdoenzyme that is primarily expressed in the liver and is involved in the metabolism of drugs and other xenobiotics. AOX-mediated metabolism can result in unexpected outcomes, such as the production of toxic metabolites and high metabolic clearance, which can lead to the clinical failure of novel therapeutic agents. Computational models can assist medicinal chemists in rapidly evaluating the AOX metabolic risk of compounds during the early phases of drug discovery and provide valuable clues for manipulating AOX-mediated metabolism liability. In this study, we developed a novel graph neural network called AOMP for predicting AOX-mediated metabolism. AOMP integrated the tasks of metabolic substrate/non-substrate classification and metabolic site prediction, while utilizing transfer learning from 13C nuclear magnetic resonance data to enhance its performance on both tasks. AOMP significantly outperformed the benchmark methods in both cross-validation and external testing. Using AOMP, we systematically assessed the AOX-mediated metabolism of common fragments in kinase inhibitors and successfully identified four new scaffolds with AOX metabolism liability, which were validated through in vitro experiments. Furthermore, for the convenience of the community, we established the first online service for AOX metabolism prediction based on AOMP, which is freely available at https://aomp.alphama.com.cn.
5.Challenges Faced by "Young" Ethics Committees under the Mode of Collaborative Review
Xiaoyan DONG ; Shuo YIN ; Xubin ZHANG ; Quan XIAO
Chinese Medical Ethics 2024;35(5):508-512
In the process of exploring standardized and efficient ethical review models for multi-center drug clinical trials, the ethical review alliance emerged as the times require. Compared with mature ethics committees, higher requirements have been put forward for the "young" ethics committees. By analyzing problems existing in review work of "young" ethics committees in the ethics review alliance, this paper discussed the measures to improve the review quality of "young" ethics committees and promote the standardized and efficient operation of the alliance, and put forward countermeasures and suggestions for improving the homogenization of ethics review and accelerating the clinical research process of innovative drugs.
6.Characteristics and significance of age-related changes in cervical uncinate process-related angle
Dezhou ZHANG ; Chaoqun WANG ; Jun SHI ; Kun LI ; Shaojie ZHANG ; Yuan MA ; Erfei HOU ; Danyang ZHAO ; Yunteng HAO ; Simin WANG ; Xiaohe LI ; Haiyan WANG ; Zhijun LI ; Xing WANG
Chinese Journal of Tissue Engineering Research 2024;28(36):5766-5772
BACKGROUND:As a unique structure of the cervical spine,the occurrence,development and progression of the uncovertebral joint directly affect the stability and range of motion of the cervical spine,and are also closely related to the pathogenesis of cervical spondylosis.A thorough understanding of the developmental characteristics of the uncovertebral joint is of great significance for the pathogenesis,diagnosis,and treatment of cervical spondylosis. OBJECTIVE:By using imaging and three-dimensional reconstruction technology to measure and observe the cervical uncinate process-related angle in a large sample of different age groups,the aim is to reveal the characteristics of its changes with age and vertebral growth,as well as its relationship with cervical spine stability. METHODS:Using a retrospective research design,we collected 1 447 cases of raw CT imaging data that meet the study requirements for complete cervical spine segments.The raw data were imported into Mimics 21.0 software in DICOM format for post-processing and measurement of angle of uncinate process and sagittal angle of uncinate process.The data were grouped based on gender,age,and side. RESULTS AND CONCLUSION:(1)With the increase of vertebral sequence,the angle of uncinate process increased in a V-shaped shape,and the lowest peak was at C5.The overall population showed a sharp peak with the increase of age,and the peak value mostly occurred in the age range of 30-39 years.(2)The sagittal angle of the uncinate process increased like a fishhook with the increase of the vertebral sequence,and the overall angle of the uncinate process increased with age,and the peak value mostly occurred in the age range of 20-29 years.The uncinate process angle and sagittal angle showed only partial significant differences between sides and genders(P<0.05).(3)It is concluded that the angle of the uncinate process increased with the increase of vertebral sequence in a V-shaped manner.The sagittal angle of the uncinate process increases like a fish hook with increasing vertebral order,while the two angles generally peak with increasing age.The angle of the uncinate process is about 131°,which may be closely related to the stability of the cervical spine,while the sagittal angle of the uncinate process is about 14°,and its function may play a certain role in limiting the excessive rotation of the cervical spine.
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Intraseasonal variation in acute health effects of extreme heat: An example using emergency ambulance calls data in Dezhou City, Shandong Province, China
Ya ZHANG ; Shengli YIN ; Weihong YANG ; Yu ZHONG ; Qi ZHAO ; Yongbiao CUI
Journal of Environmental and Occupational Medicine 2024;41(8):849-854
Background Intraseasonal variation in acute health effects of extreme heat remains insufficiently investigated. Emergency ambulance calls (EACs) may offer timely insights into the population's health during such extreme heat events. Objective To analyze intraseasonal variation in the association between extreme heat and hourly EACs during summer in Dezhou City, Shandong Province, China. Methods We collected data on all-cause hourly EACs in Dezhou City from 2021 to 2022 and assigned hourly temperature and humidity data (with a spatial resolution of 0.0625° × 0.0625°) to call addresses. Summer in this study was defined as from June to September each year, with June to July considered as early summer and August to September as late summer. Extreme heat was defined as the 99th percentile of the temperature range during the summer. We employed a time-stratified case-crossover design using conditional logistic regression integrating distributed-lag nonlinear models to compare the association between extreme heat and the risk of hourly EACs in both early and late summer periods. Results A total of

Result Analysis
Print
Save
E-mail