1.Audit to assess the quality of 916 prosthetic prescriptions of removable partial dentures.
Na ZHANG ; Bochun MAO ; Yunhan DAI ; Shengkai CHEN ; Ziying YOU ; Junjing ZHANG ; Xin CHEN ; Haoyue DONG ; Li YUE ; Haiyang YU
West China Journal of Stomatology 2023;41(3):315-322
OBJECTIVES:
The objectives of this study were to assess the quality of prosthetic prescriptions of removable partial dentures (RPDs) and to analyze the current situation of the communication and information delivery between clinicians and technicians.
METHODS:
All RPD prosthetic prescriptions received by a major dental laboratory in 4 weeks were involved in a quality audit, and the prescriptions were divided into three groups in accordance with the grades of clients. The filling of prosthetic prescriptions was recorded. The items in the prescriptions for audit included the general information of the patient, the general information of the clinician, the design diagram information, other detailed information, and the return date. The prescriptions were categorized into four levels on the basis of their quality by two quality inspectors who have been working for more than 10 years.
RESULTS:
A total of 916 prescriptions were collected and assessed. The names in the general information of the patient and the clinician were filled out best, both at the rate of 97.6% (n=894). The return date was filled out worst, only at the rate of 6.4% (n=59). Of those prescriptions, 86.8% (n=795) exhibited inadequate design diagram information. The results of the quality assessment demonstrated that 74.2% of prescriptions were assessed as noncompliant ones and failed to meet the acceptable clinical quality standard.
CONCLUSIONS
At present, the overall quality of RPD prosthetic prescriptions is poor. The responsibilities of clinicians and technicians are unclear, and the communication between them is not ideal.
Humans
;
Denture Design
;
Denture, Partial, Removable
;
Prescriptions
2.Finite element analyses of retention of removable partial denture circumferential clasps manufactured by selective laser melting.
Ke Nan MA ; Hu CHEN ; Yan Ru SHEN ; Yong Sheng ZHOU ; Yong WANG ; Yu Chun SUN
Journal of Peking University(Health Sciences) 2022;54(1):105-112
OBJECTIVE:
To compare the retentions of different designs of cobalt-chromium (Co-Cr), pure titanium (CP Ti), and titanium alloy (Ti-6Al-4V) removable partial denture (RPD) circumferential clasps manufactured by selective laser melting (SLM) and to analyze the stress distribution of these clasps during the removal from abutment teeth.
METHODS:
Clasps with clasp arm size A (1.9 mm width/1.1 mm thickness at the body and 0.8-taper) or B (1.2 times A) and 0.25 mm or 0.50 mm undercut engagement were modeled on a prepared first premolar die, named as designs A1, A2, A3, and A4, respectively. The density and elastic modulus of SLM-built Co-Cr, CP Ti, and Ti-6Al-4V were measured and given to different groups of clasps. The density, elastic modulus, and Poisson ' s ratio of enamel were given to the die. The control group was the cast Co-Cr clasp with design A1, to which the density and elastic modulus of cast Co-Cr alloy were given. The Poisson's ratio of all metals was 0.33. The initial 5 N dislodging force was applied, and the maximum displacement of the clasp along the insertion path was computed. The load was reapplied with an increment of 5 N than in the last simulation until the clasp was completely dislodged. The retentive force range of different groups of clasps was obtained. The retentive forces of the SLM-built Co-Cr, CP Ti, and Ti-6Al-4V clasps with equivalent computed retentive force range to the control group were validated through the insertion/removal experiment. The von Mises stress distributions of these three groups of SLM-built clasps under 15 N loads were analyzed.
RESULTS:
SLM-built Co-Cr, CP Ti, and Ti-6Al-4V clasps with designs B1 or B2, and Co-Cr clasps with design A2 had higher retentive forces than those of the control group. SLM-built CP Ti and Ti-6Al-4V clasps with design A1 had lower retentive forces than those of the control group. SLM-built Co-Cr clasp with design A1 and SLM-built CP Ti and Ti-6Al-4V clasps with design A2 had equivalent retentive forces to those of the control group. The insertion/removal experiment showed that the measured retentive forces of these three groups of SLM-built clasps were (21.57±5.41) N, (19.75±4.47) N, and (19.32±2.04) N, respectively. No statistically significant measured retentive force difference was found among these three groups of SLM-built clasps (P>0.05). The maximum von Mises stress of these three groups of SLM-built clasps exceeded their responding yield strength except for the Ti-6Al-4V one.
CONCLUSION
SLM-built Co-Cr circumferential clasps had higher retention than CP Ti and Ti-6Al-4V ones with the same clasp arm size and undercut engagement. The retention of SLM-built circumferential clasps could be adjusted by changing the undercut engagement and clasp arm size. If SLM-built circumferential clasps are used in clinical practice, the Ti-6Al-4V clasp with clasp arm size A and 0.50 mm undercut engagement is recommended considering the long-term use of RPD in the patient's mouth.
Chromium Alloys
;
Dental Clasps
;
Denture Retention
;
Denture, Partial, Removable
;
Finite Element Analysis
;
Humans
;
Lasers
;
Titanium
3.Maxillary Occlusion rehabilitation of multiple anterior teeth agenesis followed by tooth wear: A case report
Muhammad Dimas Aditya Ari ; Abil Kurdi ; Yonatan Christian Suisan ; Harry Laksono
Acta Medica Philippina 2021;55(8):849-853
A 19-year-old female patient came with the chief complaint that the upper anterior teeth looked small and with many spaces. The patient claimed that the tooth had never been replaced since birth. The patient wanted to improve the aesthetics of the tooth. Treatment, in this case, was made using a fixed prosthetic to aesthetically rehabilitate through prosthodontic treatment in the anterior teeth agenesis followed by attrition. It can be concluded that fixed prosthodontic treatment using a splint bridge is one treatment option that can be used in multiple anterior teeth agenesis followed by tooth wear. An appropriate material selection increases the aesthetics and functional aspects of the final treatment.
Denture, Partial, Fixed
;
Anodontia
;
Dental Occlusion
;
Humans
;
Health
4.Evaluation of methods for fitness of removable partial denture.
Jung Min YOON ; Zi Xuan WANG ; Chon Kai CHAN ; Yu Chun SUN ; Yun Song LIU ; Hong Qiang YE ; Yong Sheng ZHOU
Journal of Peking University(Health Sciences) 2021;53(2):406-412
OBJECTIVE:
To compare the differences and indications of three evaluation methods for fitness evaluation of removable partial denture (RPD).
METHODS:
A RPD was fabricated and seated on the stone cast of a partially edentulous mandible, and the spaces between RPD and stone cast were recorded with polyvinyl siloxane (PVS) impression material forming PVS replicas. Using cross sectional measurement, the average thicknesses of PVS replicas were measured under stereomicroscope with different numbers of selected measuring points in the denture base, major connector, occlusal rest of the RPD, and the average thicknesses of the PVS replicas measured with different numbers of measuring points were compared using one-way analysis of variance (ANOVA) and independent sample t test. Three kinds of method, including cross sectional measurement, three-dimensional analysis on the stone cast, and three-dimensional analysis on the polyether cast, were applied to measure the average thicknesses of the PVS replicas, and the average thicknesses of the PVS replicas measured by these three evaluation methods were compared with ANOVA.
RESULTS:
For cross sectional measurement, statistically significant differences were found in the average thicknesses of the PVS replicas in the denture base and the major connector among the different numbers of measuring points (P < 0.05), but no differences were found in the average thicknesses of the PVS replicas in the occlusal rest (P>0.05). There were significant differences among the average thicknesses of the PVS replicas measured by these three evaluation methods in each component of the RPD (P < 0.01). The average thickness measured by three-dimensional analysis on the stone cast and three-dimensional analysis on polyether cast were smaller than that measured by cross sectional measurement (P < 0.05). And there were no differences between the average thicknesses of PVS replicas measured by three-dimensional analysis on stone cast and three-dimensional analysis on polyether cast (P>0.05).
CONCLUSION
For cross sectional measurement, the average thickness of the PVS replicas was influenced by the number of measuring points, and the measurement accuracy of cross sectional measurement was not reliable enough. Three-dimensional analysis on stone cast which is suitable for evaluation in vitro and three-dimensional analysis on polyether cast which is suitable for evaluation in vivo can evaluate the fitness of RPD more comprehensively and effectively than that of cross sectional measurement.
Computer-Aided Design
;
Cross-Sectional Studies
;
Denture, Partial, Removable
;
Exercise
;
Research Design
5.Effects of 3 kinds of processing techniques on the fitness of metal clasp.
Xinping YIN ; Hongbo ZHOU ; Fei YAN ; Xiling WU ; Guofeng WU ; Danlin PANG
Journal of Central South University(Medical Sciences) 2021;46(10):1122-1128
OBJECTIVES:
At present, removable partial denture is still one of the main restoration methods for dentition defects. However, the trend for digital partial denture is becoming more and more obvious in the field of oral repair. However, there are relatively few studies on digital removable partial denture. The aim of this study is to investigate the effects of 3 processing technologies (precision casting, digital cutting, and 3D printing) on the fitness for the clasps of cobalt chromium alloy and pure titanium removable partial denture, and to provide a theoretical basis for the clinical application of digital removable partial denture.
METHODS:
Clasps of Co-Cr alloy and pure titanium were produced by 3 different processing technologies (precision casting, digital cutting, and 3D printing). There are 6 groups, including a casting pure titanium group, a casting cobalt chromium group, a cutting pure titanium group, a cutting cobalt chromium group, a printing pure titanium group, and a printing cobalt chromium group (
RESULTS:
There was no statistical difference in fitness between the casting pure titanium group and the casting cobalt chromium group (
CONCLUSIONS
The cobalt chromium alloy and pure titanium clasps made by precision casting, digital cutting, and 3D printing have good fitness. Under the same process, there is no significant difference between cobalt chromium alloy and pure titanium clasps. The 3D printing pure titanium clasps have better fitness than casting pure titanium and cutting pure titanium clasps, which meet the needs of clinical application.
Chromium Alloys
;
Cobalt
;
Denture, Partial, Removable
;
Titanium
6.A technique to design the framework of removable partial denture by multi-stage expert system.
Xin CHEN ; Bo-Chun MAO ; Chen-Yang XIE ; Qian-Qian ZHANG ; Ji-Kui SUN ; Li YUE ; Hai-Yang YU
West China Journal of Stomatology 2020;38(4):475-478
This study aims to apply a new expert system to design removable partial denture (RPD) framework. The RPD design is completed in three steps, namely, "selecting missing teeth", "selecting abutment condition", and "selecting personalized clasp". The system can help auxiliary dentists develop personalized treatment plans to reduce their clinical workload. It can also generate a dental preparation guideline for clinical preparation, which can prevent tooth preparation mistakes. By generating the standard electronic drawings of the framework design, the system can reduce the inconvenience caused by manual drawing, thereby facilitating dentist-technician communication and reducing the rate of remade.
Dental Abutments
;
Denture Design
;
Denture, Partial, Removable
;
Expert Systems
;
Tooth
7.Application of single-retainer all-ceramic resin-bonded fixed partial denture in the maintenance of missing incisor gap after orthodontic treatment in adolescents: a case report.
Guan-Yi LIU ; Li-Yuan YANG ; Jing GUO
West China Journal of Stomatology 2020;38(1):101-103
This article reports a case of an orthodontic adolescent patient without a right inferior incisor. The right lower canine was used as the abutment. The single-retainer all-ceramic resin-bonded fixed partial denture was used to restore the complete dentition. Thus, the missing space was filled, and the function and aesthetics were restored.
Adolescent
;
Ceramics
;
Denture Design
;
Denture, Partial, Fixed
;
Denture, Partial, Fixed, Resin-Bonded
;
Esthetics, Dental
;
Humans
;
Incisor
8.Fiber-reinforced composite resin bridges: an alternative method to treat root-fractured teeth
Gun HEO ; Eun Hye LEE ; Jin Woo KIM ; Kyung Mo CHO ; Se Hee PARK
Restorative Dentistry & Endodontics 2020;45(1):8-
The replacement of missing teeth, especially in the anterior region, is an essential part of dental practice. Fiber-reinforced composite resin bridges are a conservative alternative to conventional fixed dental prostheses or implants. It is a minimally invasive, reversible technique that can be completed in a single visit. The two cases presented herein exemplify the treatment of root-fractured anterior teeth with a natural pontic immediately after extraction.
Dental Prosthesis
;
Denture, Partial, Fixed
;
Methods
;
Tooth
9.Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report
You Kyoung OH ; Chang Mo JEONG ; Mi Jung YUN ; So Hyoun LEE ; Hyeon Jong LEE ; Jung Bo HUH
The Journal of Korean Academy of Prosthodontics 2020;58(1):58-66
Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified into screw-retained and cement-retained type according to the retention type, and each has advantages and disadvantages. The EZ crown system (Samwon DMP, Yangsan, Korea) has a cylinder combined with abutment, and the nickel-titanium spring in this cylinder provides a constant force on the zirconia ball to obtain retention in EZ crown system. In this patient, the natural abutment teeth of the mandibular overdenture was hopeless. We planned implant assisted removable partial denture using anterior implant surveyed prosthesis considering functional and esthetical rehabilitation, cost and patient's needs. When fabricating IARPDs using implant as abutment, we could compensate for the shortcomings of existing implant-supported prosthesis retention type and made the design of removable partial denture easy due to using EZ crown system.
Crowns
;
Denture, Overlay
;
Denture, Partial, Removable
;
Gyeongsangnam-do
;
Humans
;
Prostheses and Implants
;
Prosthesis Retention
;
Rehabilitation
;
Tooth
10.Aesthetic rehabilitation of the severe bone loss on anterior region using Andrew’s Bridge: A case report
Reni Puspa Daniat ; Rostiny Hendrijantini ; Nike Hendrijantini
Acta Medica Philippina 2019;53(6):506-511
A patient with several missing teeth in the anterior region usually experiences severe hard and soft tissue loss, posing a greater challenge for the prosthodontist to treat. This is a case of a 50-year-old female patient who came to the RSGMP UNAIR department of prosthodontics needing to replace the old denture that felt loose and had a change of color to rehabilitate the loss of large residual ridges involving hard and soft tissue. The patient has lost the central and lateral right maxillary incisors with severe hard and soft tissue defect after cyst removal in the region. The patient considered to restore an anterior region with severe hard and tissue loss. Andrew’s Bridge successfully restores an anterior region with severe hard and soft tissue loss.
Denture, Partial, Removable


Result Analysis
Print
Save
E-mail