1.A comparative study based on the mandibular movement track and the movement parameters of the virtual articulator in simulating occlusal adjustment.
Liya MA ; Jiarui CHAO ; Fei LIU ; Jiansong MEI ; Jiefei SHEN
West China Journal of Stomatology 2023;41(3):254-259
OBJECTIVES:
This study aimed to compare the effects of virtual adjustment on occlusal interferences in mandibular posterior single crown and three-unit bridge restorations by using the mandibular movement track and the movement parameters of a virtual articulator.
METHODS:
Twenty-two participants were recruited. Digital casts of the maxillary and mandibular arches were obtained using an intraoral scanner, and the jaw registration system was used to record the data of the mandibular movement track and the movement parameters of the articulator. Four kinds of restorations with 0.3 mm occlusal interferences were designed with dental design software. In particular, single crowns were designed for teeth 44 and 46, whereas three-unit bridges were designed for teeth 44-46 and 45-47, and the corresponding natural teeth were virtually extracted. Virtual adjustment of the restorations was performed using two dynamic occlusal recordings, namely, the mandibular movement track and the movement parameters of the virtual articulator. A reverse-engineering software was used to measure the root-mean-square of the three-dimensional deviation of the occlusal surfaces between natural teeth and the adjusted restorations. The differences between the two methods of virtual-occlusion adjustment were compared and analyzed.
RESULTS:
For the same group of restorations, the three-dimensional deviation of the mandibular movement track group were lower than those of the virtual articulator group, and the differences were statistically significant (P<0.05). For the four groups of restorations adjusted by the same method, the three-dimensional deviation of the 46-tooth single crown was the largest and the smallest three-dimensional deviation was that of the 44-tooth single crown. Statistical differences existed between the 44-tooth single crown and the other groups (P<0.05).
CONCLUSIONS
For the occlusal design of posterior single crown and three-unit bridge, the mandibular movement track could be a more effective approach to virtual occlusal adjustment than the movement parameters of the virtual articulator.
Humans
;
Mouth, Edentulous
;
Occlusal Adjustment
;
Jaw Relation Record
;
Dental Articulators
;
Software
2.Evolution and development: engine-driven endodontic rotary nickel-titanium instruments.
International Journal of Oral Science 2022;14(1):12-12
Various engine-driven NiTi endodontic files have been indispensable and efficient tools in cleaning and shaping of root canals for practitioners. In this review, we introduce the relative terms and conceptions of NiTi file, including crystal phase composition, the design of the cutting part, types of separation. This review also analysis the main improvement and evolution of different generations of engine-driven nickel-titanium instruments in the past 20 years in the geometric design, manufacturing surface treatment such as electropolishing, thermal treatment, metallurgy. And the variety of motion modes of NiTi files to improve resistance to torsional failure were also discussed. Continuous advancements by the designers, provide better balance between shaping efficiency and resistance to of NiTi systems. In clinical practice an appropriate system should be selected based on the anatomy of the root canal, instrument characteristics, and operators' experience.
Dental Alloys/chemistry*
;
Dental Instruments
;
Equipment Design
;
Nickel/chemistry*
;
Root Canal Preparation
;
Titanium/chemistry*
3.The Evidence-based Periodontal Risk Assessment (PRA) Tool for Nonsurgical Periodontal Therapy in a Comprehensive Periodontal Management by Risk Assessment (PEMBRA)
Mahyunah Masud ; Izza Ilyani Mohd Ishak ; Najihah Kamarazaman ; Izyan Hazwani Baharuddin
Archives of Orofacial Sciences 2022;17(SUPP 1):85-96
ABSTRACT
In the management of periodontitis patients, periodontal risk assessment (PRA) tool is currently being
applied during periodontal review (PR). However, an assessment of risk profiles during examination and
diagnosis (E&D) may and would effectively assess and diagnose patients’ periodontal conditions, provide
personalised treatment planning, and render an enhanced patient care through periodontal management
by risk assessment (PEMBRA). From a retrospective study on selected records of 81 patients treated
for chronic periodontitis, the PRA profiles of the patients were evaluated during E&D and two to three
months after completion of nonsurgical periodontal therapy (NSPT) during PR. The results were
analysed using SPSS version 24 for descriptive statistics. On E&D, the patients presented with 25.9%
localised and 74.1% generalised chronic periodontitis. Of these, 2.5% of low-risk patients on E&D
increased to 21% during PR signifying an improvement after the treatment. However, the medium-risk
patients have a slight increase from 32% to 35%, and patients with a high risk of 62% were reduced to
43%. The improvement of the risk profiles for both low and high-risk groups was mostly contributed
by the reduction in the plaque score, percentages of bleeding on probing (BOP), and probing pocket
depth (PPD) ≥ 5 mm. This evidence-based evaluation of PRA tool during E&D and PR is important for PEMBRA as it encouraged the clinicians to adopt periodontal management through basic periodontal
examination, detailed periodontal charting, radiographic interpretation, tooth per tooth prognosis,
diagnosis, and targeted NSPT.
Risk Assessment
;
Periodontal Diseases -- diagnosis
;
Dental Instruments
4.Diagnostic consistency for observing endodontic files in digital radiographs displayed on different electronic devices.
Chinese Journal of Stomatology 2022;57(4):384-389
Objectives: To evaluate the diagnostic consistency of working lengths by observing endodontic files in root canals and periapical subtle structures in digital intraoral radiographs presented in two smartphones, a tablet and a laptop computer. Methods: A dried human skull embedded in an acrylic compound was used for exposing radiographs of the upper and lower second premolars and first molars with two endodontic files (Kerr files size 10 and 15) positioned to the full length of the roots or 1.5 mm short of apexes. A total of 100 radiographs were taken for each of the file sizes. Five observers were asked to assess all the 200 digital radiographs according to a 5-category scale in smartphone A (HUAWEI P9 Plus), smartphjone B (Apple iPhone 7), tablet (Apple iPad 2018) and laptop computer (Lenovo Thinkpad E480), respectively. The gold standard for receiver operating characteristic curve (ROC) analysis was determined with the endodontic Kerr file size 20. A total of 150 roots with files were radiographed, 75 of which with files reaching the radiographic apexes of the respective roots and 75 of which with files 1.5 mm short of the radiographic apexes for each endodontic file size. Results from ROC analysis was analyzed with one-way ANOVA and independent sample t test. Results: For the Kerr file size 10, the area under the ROC curve for laptop, tablet and two smartphones were 0.891±0.037, 0.869±0.037, 0.870±0.017 and 0.849±0.037, while for the Kerr file size 15 the ROC values were 0.957±0.02, 0.961±0.02, 0.961±0.01 and 0.961±0.02, respectively. There were no significant differences for diagnostic accuracy for observing endodontic file positions among digital radiographs presented in the two smartphones, one tablet and one laptop devices (endodontic file size 10: F=1.39, P=0.281; endodontic file size 15: F=0.05, P=0.985). A significant difference was found in the diagnostic accuracy of endodontic file positions between size 10 and 15 files in different display devices (t=-10.65, P<0.001). Conclusions: There was a high diagnostic consistency in the determination of working length and periapical subtle structures of roots by observing digital radiographs displayed on smartphones, tablet and laptop computer.
Dental Instruments
;
Dental Pulp Cavity/diagnostic imaging*
;
Electronics
;
Humans
;
Molar
;
Observer Variation
;
Root Canal Preparation
5.Accuracy of intercuspal occlusion in 3D reconstruction with the dental articulator position method.
Lin Lin LI ; Yi Jiao ZHAO ; Hu CHEN ; Yong WANG ; Yu Chun SUN
Journal of Peking University(Health Sciences) 2020;52(1):138-143
OBJECTIVE:
To evaluate the three-dimensional (3D) reconstruction accuracy of the intercuspal occlusion (ICO) of the dental casts, by the dental articulator position method, and provide a reference for clinical application.
METHODS:
The standard dental casts in ICO were mounted on average values articulator, and five pairs of milling resin cylinders were respectively attached to the base of both the casts. 100 μm articulating paper and occlusal record silicone rubber were used to detect the occlusal contact number between the posterior teeth of casts mounted on articulator in ICO. The occlusal contact numbers NA detected by the two methods were calculated simultaneously, as the reference. After the upper and lower casts were scanned separately, and the buccal data of casts in ICO were scanned with the aid of the dental articulator position, registration was carried out utilizing the registration software. Then the digital casts mounted in ICO as well as the buccal occlusal data were saved in standard tessellation language (STL) format. Geomagic Studio 2013 software was used to analyze the contact number NS between digital upper and lower casts by the "deviation analysis" function. The differences were compared between NS and NA, to evaluate the sensitivity and positive predict value (PPV) of the model scanner to reproduce the occlusal contact with the aid of dental articulator position. The distance DR between the centers of the circles at the top surface of the upper and lower corresponding cylinders was obtained by the three-coordinate measuring system Faro Edge, as the reference value. The Geomagic Studio 2013 software was used to construct the cylinders of digital casts and the distance DM between the centers of the circles at the top surface of the corresponding cylinders were measured, as the test value. The one-sample T test was used to analyze the variable differences between DM and DR.
RESULTS:
The PPV of reproducing the occlusal contact point was 0.76 and sensitivity was 0.81. The distance error of the opposite cylinder was (0.232±0.089) mm. There was no statistical difference between the feature points 5-5', while there were statistical differences between the other feature points.
CONCLUSION
By the dental articulator position method, the model scanner reproduces the occlusal contact point with high sensitivity and PPV, and that meets clinical needs. Meanwhile, the distance between the feature points is greater than the reference value, which will lead to occlusal disturbance, and require clinical grinding.
Dental Articulators
;
Dental Occlusion
;
Imaging, Three-Dimensional
;
Jaw Relation Record
;
Models, Dental
;
Software
6.Method and accuracy of determining the jaw position of repositioning splint with the aid of digital technique.
Shuo Bo FANG ; Guang Ju YANG ; Yan Feng KANG ; Yu Chun SUN ; Qiu Fei XIE
Journal of Peking University(Health Sciences) 2020;53(1):76-82
OBJECTIVE:
To establish the workflow of determining the jaw position of repositioning splint with the aid of digital technique, and to evaluate the accuracy of this workflow and compare the accuracy of raising different vertical dimensions in vitro.
METHODS:
A volunteer was recruited. The data of full-arch scans, cone beam computed tomography (CBCT) image and ultrasonic jaw motion tracking of the volunteer were acquired. The full-arch scans were merged with the CBCT image, which were then matched to the jaw motion tracking reference system. The jaw position of repositioning splint was determined when the anterior teeth opening was 3 mm and the condyle was in centric relation of the fossa in the sagittal plane. A digital repositioning splint was designed in the software based on virtual articulator and fabricated with additive manufacturing technique. After the splint was tried in, another CBCT image was taken and a qualitative analysis was conducted to compare the position of condyle between these two CBCT images. In the in vitro study, standard dental plaster casts with resin ball markers attached to the base were mounted onto a fully adjustable articulator in the intercuspal position. The dental casts were scanned by an extraoral scanner to establish digital models. The ultrasonic jaw motion tracking device was used to obtain simulated jaw movements on the articulator, which was repeated for three times. The digital models and data of jaw movements were merged in one coordination with the aid of bite forks. The jaw position of repositioning splint was determined by adjusting data of jaw movements, each of which was used to determine three vertical jaw positions 4 mm, 5 mm, and 6 mm with the horizontal jaw position of protrusion 2 mm. The virtual articulators with differently adjusted jaw movements were applied in designing repositioning splints, and the final repositioning splints and virtual jaw relationships were exported in STL format. Then the repositioning splints were fabricated with additive manufacturing technique and tried in plaster casts on the mechanical articulator, which were scanned and the jaw relationships on the mechanical articulator were exported later. The virtual jaw relationships and scanned jaw relationships were registered according to lower models and displacement of upper models was calculated. Ball markers were fit to acquire the coordinates of centers and absolute difference values of centers along three coordinating axes X, Y, and Z were calculated. One-way analysis of variance was conducted using SPSS 18.0 software to compare deviations of the three different vertical jaw relationships in two-side test and the significance level was 0.05.
RESULTS:
With the aid of multi-source data fusion and individualized jaw motion, the clinical workflow of determining jaw position of repositioning splint was preliminarily established. The designed jaw position was realized on the right and the condyle was more inferior than the designed position on the left. Both displacement of the upper models and absolute difference values of centers showed no significant differences (P>0.05) in different vertical jaw dimensions. The displacement of the upper models was (0.25±0.04) mm. The absolute difference values of centers along the three coordinating axes X, Y, and Z were respectively (0.08±0.01) mm, (0.30±0.02) mm, and (0.21±0.04) mm.
CONCLUSION
A novel method of determining the jaw position of repositioning splint with the aid of digital technique is established. It is proved to be feasible by try-in after multi-data fusion, computer-aided design and computer-aided manufacturing. As is shown in vitro, it is accurate to apply this method in adjusting jaw position. Further clinical trial will be designed to evaluate its clinical effect.
Computer-Aided Design
;
Cone-Beam Computed Tomography
;
Dental Articulators
;
Humans
;
Jaw Relation Record
;
Occlusal Splints
;
Software
;
Splints
7.Awareness of occupational hazards and personal protective equipment use among dental hygienists
Hyun Ju CHOI ; Tae Yoon HWANG ; Man Joong JEON
Yeungnam University Journal of Medicine 2019;36(1):20-25
BACKGROUND: The aim of this study was to evaluate the awareness of occupational hazards and personal protective equipment use among dental hygienists (DHs).METHODS: A total of 271 self-administered questionnaires were obtained from 280 DHs working at dental hospitals or clinics in Daegu and Gyeongsangbuk-do, Korea.RESULTS: The occupational hazards included work involving dust (94.1%), volatile substances (86.0%), noise (97.0%), and light-curing units (96.7%). The proportion of dental hygiene tasks that participants perceived as harmful were 42.4%, 51.7%, 9.2%, and 31.4% in the same order as above. The proportion of participants who used dust-proof masks during work involving dust was 1.1%. Those who wore gas-proof masks and gloves for work using volatile substances were 0.7% and 31.2%, respectively. Participants who used goggles for work involving light-curing units were 31.0%. None of the participants used ear plugs for work involving noise. A total of 22.9% of the participants recognized the Material Safety Data Sheet, while 79.7% had never been educated about harmful work environments.CONCLUSION: When compared to exposure status and perception of occupational hazards, the level of protective equipment use was very low. Extra measures to increase DHs’ use of personal protective equipment are necessary.
Daegu
;
Dental Hygienists
;
Dust
;
Ear
;
Eye Protective Devices
;
Gyeongsangbuk-do
;
Humans
;
Korea
;
Masks
;
Material Safety Data Sheets
;
Noise
;
Occupations
;
Oral Hygiene
;
Personal Protective Equipment
8.Elucidating the relationship of gingivitis and dental calculus with the periodontal health of 12-year-old children
Jung Ha LEE ; Se Yeon KIM ; Ji Soo KIM ; Min Ji BYON ; Eun Joo JUN ; Han Na KIM ; Jin Bom KIM
Journal of Korean Academy of Oral Health 2019;43(4):196-203
OBJECTIVES: This study aimed to investigate factors related to the periodontal health of 12-year-old children.METHODS: In 2015, the Korean Children's Oral Health Survey from the Ministry of Health & Social Welfare conducted a nationwide representative sample comprised of 23,702 12-year-old children. The calibration-trained dentists examined the gingivitis and dental calculus of the children taking into consideration of the Löe and Silness gingival index to diagnose gingivitis with a modified gingivitis scale. We used questionnaires to collect data from the children on dental treatments, the experience of dental pain and gingival bleeding, self-perceived oral health, and oral health behaviors. Data were analyzed using a complex samples Chi-square test, general linear model, and logistic regression. Significance was determined at P < 0.05.RESULTS: The prevalence of gingivitis was higher among males (OR 1.57), among children with poor perception (OR 1.19), dental calculus (OR 3.68), or gingival bleeding experience (OR 2.00), and among children not using dental floss (OR 1.69) or tongue cleaner (OR 1.90). The prevalence of dental calculus was higher among children with gingivitis (OR 3.82) and among children who had not visited a dental clinic in the preceding year (OR 1.31). However, dental calculus was lower among children with a higher frequency of daily toothbrushing (OR 0.75), intake of cariogenic foods (OR 0.90), or a higher DMFT index (OR 0.91).CONCLUSIONS: Children with dental calculus and gingival bleeding who did not visit a dental clinic in the preceding year also had a higher prevalence of gingivitis and dental calculus. The prevalence of children's dental calculus was lower among children with a high frequency of daily toothbrushing.
Child
;
Dental Calculus
;
Dental Clinics
;
Dental Devices, Home Care
;
Dentists
;
Gingivitis
;
Hemorrhage
;
Humans
;
Linear Models
;
Logistic Models
;
Male
;
Oral Health
;
Periodontal Index
;
Prevalence
;
Social Welfare
;
Tongue
;
Toothbrushing
9.A CAD/CAM-based strategy for concurrent endodontic and restorative treatment
Patricia Maria ESCOBAR ; Anil KISHEN ; Fabiane Carneiro LOPES ; Caroline Cristina BORGES ; Eugenio Gabriel KEGLER ; Manoel Damião SOUSA-NETO
Restorative Dentistry & Endodontics 2019;44(3):e27-
This case report describes a technique in which endodontic treatment and permanent indirect restoration were completed in the same clinical appointment with the aid of a computer-aided design/computer-aided manufacturing (CAD/CAM) system. Two patients were diagnosed with irreversible pulpitis of the mandibular first molar. After access preparation, root canals were located, irrigation was performed until bleeding ceased, and the coronal tooth structure was prepared for indirect restoration. Then, utilizing an interim 3-mm build-up of the endodontic access cavity, a hemi-arch digital scan was performed with an intraoral scanner. Subsequent to digital scanning, restoration design was performed simultaneously with the endodontic procedure. The root canals were shaped using the Race system under irrigation with 2.5% sodium hypochlorite followed by root canal filling. The pulp chamber was subsequently filled with a 3-mm-thick composite resin restoration mimicking the interim build-up previously utilized to facilitate block milling in the CAD/CAM system. Clinical try-in of the permanent onlay restoration was followed by acid etching, application of a 5th generation adhesive, and cementation of the indirect restoration. Once the restoration was cemented, rubber dam isolation was removed, followed by occlusal adjustment and polishing. After 2 years of follow-up, the restorations were esthetically and functionally satisfactory, without complications.
Adhesives
;
Cementation
;
Computer-Aided Design
;
Continental Population Groups
;
Dental Pulp Cavity
;
Endodontics
;
Follow-Up Studies
;
Hemorrhage
;
Humans
;
Inlays
;
Molar
;
Occlusal Adjustment
;
Pulpitis
;
Rubber Dams
;
Sodium Hypochlorite
;
Tooth
10.The survey on the infection control of noncritical instruments used in dental treatment
Journal of Dental Rehabilitation and Applied Science 2019;35(1):27-36
PURPOSE: The aims of this study were to evaluate the dentist's awareness and the actual status of infection control of noncritical dental instruments. MATERIALS AND METHODS: 40 dental clinics in Daejeon, South Chungcheong, North Chungcheong and North Jeolla provinces were surveyed. The questionnaire was delivered to the dentists belonging to those clinics, and the awareness and the practice of infection control were examined. The microbial contamination on the surface of five noncritical instruments (impression gun, light curing unit, 3-way syringe, shade guide, and dental floss dispenser) used by them was measured with an ATP luminometer. Correlation analysis between the awareness and the actual state of infection control was conducted. RESULTS: Awareness and frequency of infection control was highest in the 3-way syringe. Surface disinfection using disinfectant was most frequent in all instruments. 3-way syringes and shade guides were less contaminated than impression guns, light curing units, and dental floss dispensers. CONCLUSION: 3-way syringes had a significant correlation between user awareness of infection control and surface contamination, and the higher awareness, the lower the contamination measurement was shown.
Adenosine Triphosphate
;
Dental Clinics
;
Dental Devices, Home Care
;
Dental Instruments
;
Dentists
;
Disinfection
;
Firearms
;
Humans
;
Infection Control
;
Syringes


Result Analysis
Print
Save
E-mail