1.Expression of allograft inflammatory factor-1 in the testicular model of diabetes mellitus rats
Dechao LI ; Mingjin ZHANG ; Yibi LAN ; Chunlei MA ; Weijin FU
The Journal of Practical Medicine 2024;40(1):65-71
Objective To investigate the expression of allograft inflammatory factor-1(AIF-1)in the testicular model of diabetes mellitus(DM)rats as well as its significance.Methods The rat model of DM testis(DMT)was established,which were randomly divided into the DM testis 4-week group(DMT4W),DM testis s 8-week group(DMT8W)and the DM testis 12-week group(DMT12W).The normal control group(NC group)was randomly divided into three subgroups:NC 4-week(NC4W),NC 8-week(NC8W)and NC 12-week(NC12W).The morphologic changes of testis in the different groups was detected by histopathology.The expression of AIF-1 protein was detected by immunohistochemistry.The expression of AIF-1 and NF-κB p65 protein was observed by immunofluorescence.Results The histopathological results suggested that the numbers of spermatogenic cells,sertoli cells,interstitial cells and sperms in the DMT group were significantly decreased,as compared with the NC group.The immunohistochemistry results showed that the expression of AIF-1 protein was significantly increased in the DMT group,as compared with the NC group(P<0.05).The intensity of AIF-1 and NF-κB p65 in the DMT group was significantly increased by immunofluorescence,as compared with the NC group.Conclusion The over expression of AIF-1 protein in DMT tissue suggests that it may play an important role in the pathological process of DMT and may become a new therapeutic target and diagnostic marker in the future.
2.The clinical value of transarterial catheterization C-arm CT perfusion scanning during prostatic artery embolization
Chengzhi ZHANG ; Mengyao SONG ; Dechao JIAO ; Xinwei HAN ; Yiming LIU ; Kaihao XU
Journal of Practical Radiology 2024;40(2):285-288
Objective To evaluate the clinical value of transarterial catheterization C-arm CT perfusion scanning technique during prostatic artery embolization(PAE)for benign prostatic hyperplasia(BPH).Methods The clinical data of 46 patients with BPH received PAE were analyzed retrospectively.All patients underwent prostatic artery(PA)digital subtraction angiography(DSA)and C-arm CT perfusion scanning to identify PA and prevent non-target organ embolization.The final recognization of PA was consulted by three senior doctors.After C-arm CT confirmation,PA was embolized with 100-300 μm polyvinyl alcohol(PVA)particles or microspheres under fluoroscopy.The postoperative complications and 3-month clinical efficacy were observed.Results A total of 106 vessels were angioraphed in 46 patients,with 83 PA vessels and 23 non-PA vessels.PA was identified by DSA and C-arm CT with sensitivity of 81.9%(68/83)and 100%(83/83),respectively,which showed significance(χ2=22.3,P<0.01).Non-PA was identified by DSA and C-arm CT with specificity of 73.9%(17/23)and 100%(23/23),which showed significance(χ2=9.2,P=0.02).No serious complications were observed and 3-month clincial efficacy was 91.3%.Conclusion Transarterial catheterization C-arm CT perfusion scanning technique can accurately identify PA,reduce PA leakage and prevent non-target organ embolization.
3.Microwave ablation synchronously with biopsy strategy for pulmonary nodules
Chengzhi ZHANG ; Zhanguo SUN ; Yi FANG ; Mengyao SONG ; Xinwei HAN ; Dechao JIAO
Journal of Practical Radiology 2024;40(4):637-640
Objective To evaluate the efficacy of microwave ablation(MWA)synchronously with biopsy for pulmonary nodules.Methods The data of 64 patients with MWA combined with biopsy were analyzed retrospectively.Thirty-one patients(non-synchronous group)were treated with ablation following biopsy in turn to identify malignant tumors,and 33 patients(synchronous group)were treated by ablation and biopsy synchronously.The technical success rate,operation time,complications,hospitalization time and expenses were compared between non-synchronous group and synchronous group.Results The technical success rate,pneumothorax,and pleural effusion rate showed no significance between the two groups(P>0.05).There were all significant differences in operation time(42.00 min vs 54.26 min),hospitalization time(5.09 days vs 9.26 days),hospitalization expenses(26 840.61 yuan vs 32 527.26 yuan),lung hemorrhage(27.27%vs 87.10%)and hemoptysis(3.03%vs 19.35%)between synchronous group and non-synchronous group,respectively(P<0.05).Conclusion MWA synchronously with biopsy for pulmonary nodules is safe and feasible,which can reduce intraoperative bleeding,shorten treatment period and reduce hospitalization expenses.
4.Trans-sheath intraluminal forceps biopsy under digital subtraction angiography guidance for assisting diagnosis of pulmonary artery obstructive diseases
Rongna HOU ; Xueliang ZHOU ; Mengyao SONG ; Chengzhi ZHANG ; Zhanguo SUN ; Yi FANG ; Xinwei HAN ; Dechao JIAO
Chinese Journal of Interventional Imaging and Therapy 2024;21(7):390-392
Objective To explore the efficiency and safety of trans-sheath intraluminal forceps biopsy under digital subtraction angiography(DSA)guidance for assisting diagnosis of pulmonary artery obstructive diseases.Methods Data of 16 patients who underwent trans-sheath intraluminal forceps biopsy for pulmonary artery obstructive diseases were retrospectively analyzed,and the clinical manifestations were recorded.The technical success of biopsy was defined as tissue obtained met the needs of pathology diagnosis.For patients with malignant pathology results,the final diagnosis was malignant,for those with benign pathology results after biopsy and no obvious changes after 6-month or longer follow-up,or benign pathology results after surgical resection,the final diagnosis was benign,otherwise was no clear diagnosis.The operation time,technical success rate,diagnostic efficiency,complications and changes of pulmonary artery pressure before and after the biopsy were observed.Results Among 16 patients,9 complained of intermittent chest tightness,4 complained of chest pain with chest tightness,2 complained of chest pain but 1 denied any symptoms.The lesions located in the left lung in 10 cases and in the right lung in 6 cases,all with enhanced CT showed filling defects of the involved branch of pulmonary artery.Totally 16 trans-sheath intraluminal forceps biopsies were performed in 16 patients,with an average operation time of(31.02±6.02)min and technical success rate of 100%.Malignant tumors were finally diagnosed in 10 cases,including 1 case of lung cancer with false-negative biopsy result,while biopsy correctly diagnosed benign lesions in the other 6 cases.Transient worsening chest pain with chest tightness occurred in 2 cases and relieved after symptomatic treatments.No statistically significant difference of pulmonary artery pressure was found before([53.38±14.28]mmHg)and after([53.69±14.15]mmHg)biopsy(P>0.05).Conclusion DSA-guided trans-sheath intraluminal forceps biopsy was relatively safe and valuable for assisting diagnosis of pulmonary artery obstructive diseases.
5.Fluoroscopy-guided Fustar adjustable bent sheath clamp biopsy for diagnosing obstructive esophageal diseases
Yipu LI ; Mengyao SONG ; Rongna HOU ; Chengzhi ZHANG ; Zhanguo SUN ; Dechao JIAO
Chinese Journal of Interventional Imaging and Therapy 2024;21(10):580-582
Objective To observe the feasibility and effectiveness of fluoroscopy-guided Fustar adjustable bent sheath clamp biopsy for diagnosing obstructive esophageal diseases.Methods Totally 29 patients with esophageal or esophagogastric junction obstruction who failed to complete endoscopic biopsy were retrospectively analyzed.Real-time fluoroscopy-guided clamp biopsy of lesion areas were performed through 10F Fustar adjustable bent sheath under local anesthesia.The technical success rate,operation time,radiation dose were recorded,and the complications were evaluated.Results Clamp biopsy of lesion areas were successfully performed in all 29 cases,with technical success rate of 100%(29/29),the average operation time of(29.81±10.05)min and the average radiation dose of(127.14±100.36)mGy.No serious complication such as esophageal perforation nor massive bleeding occurred.After biopsy,22 cases(22/29,75.86%)were preliminarily diagnosed as positive,among them 2 cases underwent surgical operation,and the postoperative pathological results were consistent with biopsy.Negative biopsy results were found in 7 cases(7/29,24.14%),among them 2 cases underwent clamp biopsy again 3 months later which showed positive results.Conclusion Fustar adjustable bent sheath clamp biopsy was feasible and effective for diagnosing obstructive esophageal diseases,which could be regarded as the substitution and supplementation of endoscopic clamp biopsy.
6.Utility of Radiographic Parameter in Assessing Bone Density and Subsequent Fractures in Patients With Osteoporotic Vertebral Compression Fracture
Yunsheng WANG ; Mei DONG ; Jiali ZHANG ; Dechao MIAO ; Feng WANG ; Tong TONG ; Linfeng WANG
Neurospine 2024;21(3):966-972
Objective:
To investigate the ability of radiological parameter canal bone ratio (CBR) to assess bone mineral density and to differentiate between patients with primary and multiple osteoporotic vertebral compression fracture (OVCF).
Methods:
A retrospective analysis was conducted on OVCF patients treated at our hospital. CBR was measured through full-spine x-rays. Patients were categorized into primary and multiple fracture groups. Receiver operating characteristic curve analysis and area under the curve (AUC) calculation were used to assess the ability of parameters to predict osteoporosis and multiple fractures. Predictors of T values were analyzed by multiple linear regression, and independent risk factors for multiple fractures were determined by multiple logistic regression analysis.
Results:
CBR showed a moderate negative correlation with dual-energy x-ray absorptiometry T values (r = -0.642, p < 0.01). Higher CBR (odds ratio [OR], -6.483; 95% confidence interval [CI], -8.234 to -4.732; p < 0.01) and lower body mass index (OR, 0.054; 95% CI, 0.023–0.086; p < 0.01) were independent risk factors for osteoporosis. Patients with multiple fractures had lower T values (mean ± standard deviation [SD]: -3.76 ± 0.73 vs. -2.83 ± 0.75, p < 0.01) and higher CBR (mean ± SD: 0.54 ± 0.07 vs. 0.46 ± 0.06, p < 0.01). CBR had an AUC of 0.819 in predicting multiple fractures with a threshold of 0.53. T values prediction had an AUC of 0.816 with a threshold of -3.45. CBR > 0.53 was an independent risk factor for multiple fractures (OR, 14.66; 95% CI, 4.97–43.22; p < 0.01).
Conclusion
CBR is negatively correlated with bone mineral density (BMD) and can be a novel opportunistic BMD assessment method. It is a simple and effective measurement index for predicting multiple fractures, with predictive performance not inferior to T values.
7.Utility of Radiographic Parameter in Assessing Bone Density and Subsequent Fractures in Patients With Osteoporotic Vertebral Compression Fracture
Yunsheng WANG ; Mei DONG ; Jiali ZHANG ; Dechao MIAO ; Feng WANG ; Tong TONG ; Linfeng WANG
Neurospine 2024;21(3):966-972
Objective:
To investigate the ability of radiological parameter canal bone ratio (CBR) to assess bone mineral density and to differentiate between patients with primary and multiple osteoporotic vertebral compression fracture (OVCF).
Methods:
A retrospective analysis was conducted on OVCF patients treated at our hospital. CBR was measured through full-spine x-rays. Patients were categorized into primary and multiple fracture groups. Receiver operating characteristic curve analysis and area under the curve (AUC) calculation were used to assess the ability of parameters to predict osteoporosis and multiple fractures. Predictors of T values were analyzed by multiple linear regression, and independent risk factors for multiple fractures were determined by multiple logistic regression analysis.
Results:
CBR showed a moderate negative correlation with dual-energy x-ray absorptiometry T values (r = -0.642, p < 0.01). Higher CBR (odds ratio [OR], -6.483; 95% confidence interval [CI], -8.234 to -4.732; p < 0.01) and lower body mass index (OR, 0.054; 95% CI, 0.023–0.086; p < 0.01) were independent risk factors for osteoporosis. Patients with multiple fractures had lower T values (mean ± standard deviation [SD]: -3.76 ± 0.73 vs. -2.83 ± 0.75, p < 0.01) and higher CBR (mean ± SD: 0.54 ± 0.07 vs. 0.46 ± 0.06, p < 0.01). CBR had an AUC of 0.819 in predicting multiple fractures with a threshold of 0.53. T values prediction had an AUC of 0.816 with a threshold of -3.45. CBR > 0.53 was an independent risk factor for multiple fractures (OR, 14.66; 95% CI, 4.97–43.22; p < 0.01).
Conclusion
CBR is negatively correlated with bone mineral density (BMD) and can be a novel opportunistic BMD assessment method. It is a simple and effective measurement index for predicting multiple fractures, with predictive performance not inferior to T values.
8.Utility of Radiographic Parameter in Assessing Bone Density and Subsequent Fractures in Patients With Osteoporotic Vertebral Compression Fracture
Yunsheng WANG ; Mei DONG ; Jiali ZHANG ; Dechao MIAO ; Feng WANG ; Tong TONG ; Linfeng WANG
Neurospine 2024;21(3):966-972
Objective:
To investigate the ability of radiological parameter canal bone ratio (CBR) to assess bone mineral density and to differentiate between patients with primary and multiple osteoporotic vertebral compression fracture (OVCF).
Methods:
A retrospective analysis was conducted on OVCF patients treated at our hospital. CBR was measured through full-spine x-rays. Patients were categorized into primary and multiple fracture groups. Receiver operating characteristic curve analysis and area under the curve (AUC) calculation were used to assess the ability of parameters to predict osteoporosis and multiple fractures. Predictors of T values were analyzed by multiple linear regression, and independent risk factors for multiple fractures were determined by multiple logistic regression analysis.
Results:
CBR showed a moderate negative correlation with dual-energy x-ray absorptiometry T values (r = -0.642, p < 0.01). Higher CBR (odds ratio [OR], -6.483; 95% confidence interval [CI], -8.234 to -4.732; p < 0.01) and lower body mass index (OR, 0.054; 95% CI, 0.023–0.086; p < 0.01) were independent risk factors for osteoporosis. Patients with multiple fractures had lower T values (mean ± standard deviation [SD]: -3.76 ± 0.73 vs. -2.83 ± 0.75, p < 0.01) and higher CBR (mean ± SD: 0.54 ± 0.07 vs. 0.46 ± 0.06, p < 0.01). CBR had an AUC of 0.819 in predicting multiple fractures with a threshold of 0.53. T values prediction had an AUC of 0.816 with a threshold of -3.45. CBR > 0.53 was an independent risk factor for multiple fractures (OR, 14.66; 95% CI, 4.97–43.22; p < 0.01).
Conclusion
CBR is negatively correlated with bone mineral density (BMD) and can be a novel opportunistic BMD assessment method. It is a simple and effective measurement index for predicting multiple fractures, with predictive performance not inferior to T values.
9.Utility of Radiographic Parameter in Assessing Bone Density and Subsequent Fractures in Patients With Osteoporotic Vertebral Compression Fracture
Yunsheng WANG ; Mei DONG ; Jiali ZHANG ; Dechao MIAO ; Feng WANG ; Tong TONG ; Linfeng WANG
Neurospine 2024;21(3):966-972
Objective:
To investigate the ability of radiological parameter canal bone ratio (CBR) to assess bone mineral density and to differentiate between patients with primary and multiple osteoporotic vertebral compression fracture (OVCF).
Methods:
A retrospective analysis was conducted on OVCF patients treated at our hospital. CBR was measured through full-spine x-rays. Patients were categorized into primary and multiple fracture groups. Receiver operating characteristic curve analysis and area under the curve (AUC) calculation were used to assess the ability of parameters to predict osteoporosis and multiple fractures. Predictors of T values were analyzed by multiple linear regression, and independent risk factors for multiple fractures were determined by multiple logistic regression analysis.
Results:
CBR showed a moderate negative correlation with dual-energy x-ray absorptiometry T values (r = -0.642, p < 0.01). Higher CBR (odds ratio [OR], -6.483; 95% confidence interval [CI], -8.234 to -4.732; p < 0.01) and lower body mass index (OR, 0.054; 95% CI, 0.023–0.086; p < 0.01) were independent risk factors for osteoporosis. Patients with multiple fractures had lower T values (mean ± standard deviation [SD]: -3.76 ± 0.73 vs. -2.83 ± 0.75, p < 0.01) and higher CBR (mean ± SD: 0.54 ± 0.07 vs. 0.46 ± 0.06, p < 0.01). CBR had an AUC of 0.819 in predicting multiple fractures with a threshold of 0.53. T values prediction had an AUC of 0.816 with a threshold of -3.45. CBR > 0.53 was an independent risk factor for multiple fractures (OR, 14.66; 95% CI, 4.97–43.22; p < 0.01).
Conclusion
CBR is negatively correlated with bone mineral density (BMD) and can be a novel opportunistic BMD assessment method. It is a simple and effective measurement index for predicting multiple fractures, with predictive performance not inferior to T values.
10.Utility of Radiographic Parameter in Assessing Bone Density and Subsequent Fractures in Patients With Osteoporotic Vertebral Compression Fracture
Yunsheng WANG ; Mei DONG ; Jiali ZHANG ; Dechao MIAO ; Feng WANG ; Tong TONG ; Linfeng WANG
Neurospine 2024;21(3):966-972
Objective:
To investigate the ability of radiological parameter canal bone ratio (CBR) to assess bone mineral density and to differentiate between patients with primary and multiple osteoporotic vertebral compression fracture (OVCF).
Methods:
A retrospective analysis was conducted on OVCF patients treated at our hospital. CBR was measured through full-spine x-rays. Patients were categorized into primary and multiple fracture groups. Receiver operating characteristic curve analysis and area under the curve (AUC) calculation were used to assess the ability of parameters to predict osteoporosis and multiple fractures. Predictors of T values were analyzed by multiple linear regression, and independent risk factors for multiple fractures were determined by multiple logistic regression analysis.
Results:
CBR showed a moderate negative correlation with dual-energy x-ray absorptiometry T values (r = -0.642, p < 0.01). Higher CBR (odds ratio [OR], -6.483; 95% confidence interval [CI], -8.234 to -4.732; p < 0.01) and lower body mass index (OR, 0.054; 95% CI, 0.023–0.086; p < 0.01) were independent risk factors for osteoporosis. Patients with multiple fractures had lower T values (mean ± standard deviation [SD]: -3.76 ± 0.73 vs. -2.83 ± 0.75, p < 0.01) and higher CBR (mean ± SD: 0.54 ± 0.07 vs. 0.46 ± 0.06, p < 0.01). CBR had an AUC of 0.819 in predicting multiple fractures with a threshold of 0.53. T values prediction had an AUC of 0.816 with a threshold of -3.45. CBR > 0.53 was an independent risk factor for multiple fractures (OR, 14.66; 95% CI, 4.97–43.22; p < 0.01).
Conclusion
CBR is negatively correlated with bone mineral density (BMD) and can be a novel opportunistic BMD assessment method. It is a simple and effective measurement index for predicting multiple fractures, with predictive performance not inferior to T values.

Result Analysis
Print
Save
E-mail