1.Recent advances in drug screening methods of SARS-CoV-2 spike protein
Li-de HU ; Chuan-feng LIU ; Ping LI ; Guan-yu DONG ; Xin-yong LIU ; Peng ZHAN
Acta Pharmaceutica Sinica 2024;59(2):298-312
The pandemic of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused a serious impact on global public health and the economy. SARS-CoV-2 infiltrates host cells
2.Clinical Observation on Abdominal Penetrating Moxibustion Combined with Acupuncture at Four Chong Acupoints for the Treatment of Stroke in the Convalescent Stage
Nan YU ; Jie HU ; Hai-Ning LI ; Shan-Shan SONG ; De-Song ZHENG ; Xin-Hong XUE ; Ying GAO
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(1):116-122
Objective To observe the effects of abdominal penetrating moxibustion combined with acupuncture at the"four chong points"on balance,walking function and trunk control in patients recovering from stroke.Methods Seventy-eight patients recovering from stroke were randomly divided into an observation group and a control group,with 39 patients in each group.The control group was given conventional rehabilitation exercises,while the observation group was given abdominal penetrating moxibustion combined with acupuncture at the"four chong points"on the basis of the control group.Both groups were treated for 2 consecutive months.After 2 months of treatment,the clinical efficacy of the two groups was evaluated,and the changes in the Berg Scale score and the Timed Up and Go Test(TUGT)were observed before and after treatment.The changes in the National Institutes of Health Stroke Scale(NIHSS)scores were compared before and after treatment between the two groups.The Sheikh Trunk Control Scale scores were also evaluated.Results(1)The total effective rate of the observation group was 94.87%(37/39),and the total effective rate of the control group was 80.00%(31/39),and the efficacy of the observation group was superior to that of the control group,and the difference was statistically significant(P<0.05).(2)After treatment,the Berg scores of the patients in the two groups were significantly increased(P<0.05),and the Berg scores of the observation group were higher than those of the control group,and the difference was statistically significant(P<0.05).(3)After treatment,the TUGT time and NIHSS score of patients in the two groups were significantly improved(P<0.05),and the TUGT time of the observation group was shorter than that of the control group,and the NIHSS score was lower than that of the control group,and the difference was statistically significant(P<0.05).(4)After treatment,the Sheikh trunk control scores of the two groups were significantly increased(P<0.05),and the Sheikh trunk control score of the observation group was higher than that of the control group,and the difference was statistically significant(P<0.05).Conclusion Abdominal penetrating moxibustion method combined with acupuncture at the four chong points for the treatment of stroke recovery can effectively restore the patients'balance and walking function,improve the patients'trunk control ability,and the therapeutic effect is precise.
3.Correlation analysis between patient stature-based optimization of image acquisition parameters and low-dose coronary angiography
Hai QIAN ; Yu-Qin ZHANG ; Ke-Nan LOU ; De-Xing HU
Chinese Journal of Interventional Cardiology 2024;32(4):191-196
Objective To explore the correlation among image acquisition parameter optimization,coronary angiography radiation dose and image quality.Methods 60 patients scheduled for elective percutaneous coronary angiography from January 2022 to January 2024 in our hospital were selected.Basic information and body measurements were collected.Patients were divided into three groups based on BMI,and patients in each BMI group were randomly assigned to the conventional mode group(coronary mode image acquisition:Cardiac Left Coronary,15fps)and the optimized mode group(electrophysiology mode image acquisition:Cardiac EP,7.5fps).Radiation dose data were collected.Image quality was evaluated using an image quality scoring table.Independent sample t-tests,Mann-Whitney U tests,and one-way ANOVA were used for comparisons between groups.Pearson analysis was used for correlations.Results Higher BMI and larger chest circumference were associated with higher radiation doses in a positive linear correlation.Within each BMI group,all radiation dose data(Dose-Area Product,Air Kerma and Chest skin dose)were lower in the optimized mode group than in the conventional mode group(all P<0.05,reduction rate 48.95%-70.59%).The difference in image quality scores between two groups was not statistically significant(P>0.05),and all images were of the required quality.Conclusions The radiation dose of percutaneous coronary angiography is affected by the patient's body size,image acquisition parameters,exposure time and many other factors.Optimizing the image acquisition parameters can ensure the quality of the image while realizing the low dose of radiation and reducing the radiation hazards to the patient and the operator.
4.Comparison of Clinical Characteristics of JAK2,CALR and Tri-Negative Driving Mutant Type in Patients with Essential Thrombocythemia
Yu-Meng LI ; Er-Peng YANG ; Zi-Qing WANG ; De-Hao WANG ; Ji-Cong NIU ; Yu-Jin LI ; Jing MING ; Ming-Qian SUN ; Zhuo CHEN ; Wei-Yi LIU ; Yan LYU ; Xiao-Mei HU
Journal of Experimental Hematology 2024;32(1):197-201
Objective:To investigate the relationship between mutated genes and clinical features in patients with essential thrombocythemia(ET).Methods:The clinical data of 69 patients with ET from October 2018 to March 2022 were retrospectively analyzed.According to driver mutation type,patients were divided into JAK2 group,CALR group and triple-negative group.The sex,age,cardiovascular risk factors,thrombosis,splenomegaly,routine blood test and coagulation status of patients in three groups were analyzed.Results:Among 69 ET patients,46 cases were associated with JAK2 mutation,14 cases with CALR mutation,8 cases with triple-negative mutation,and one with MPL gene mutation.There were no significant differences in age and sex among the three groups(P>0.05).The highest thrombotic rate was 26.09%(12/46)in JAK2 group,then 12.5%(1/8)in triple-negative group,while no thrombotic events occurred in CALR group.The incidence of splenomegaly was the highest in JAK2 group(34.78%),while no splenomegaly occurred in triple-negative group.The white blood cell(WBC)count in JAK2 group was(9.00±4.86)× 109/L,which was significantly higher than(6.03±2.32)× 109/L in CALR group(P<0.05).The hemoglobin(Hb)and hematocrit(HCT)in JAK2 group were(148.42±18.79)g/L and(0.44±0.06)%,respectively,which were both significantly higher than(131.00±15.17)g/L and(0.39±0.05)%in triple-negative group(P<0.05).The platelet(PLT)in JAK2 group was(584.17±175.77)× 109/L,which was significantly lower than(703.07±225.60)× 109/L in CALR group(P<0.05).The fibrinogen(Fg)in JAK2 and triple-negative group were(2.64±0.69)g/L and(3.05±0.77)g/L,respectively,which were both significantly higher than(2.24±0.47)g/L in CALR group(P<0.05,P<0.01).The activated partial thromboplastin time(APTT)in triple-negative group was(28.61±1.99)s,which was significantly decreased compared with(31.45±3.35)s in CALR group(P<0.05).Conclusions:There are differences in blood cell count and coagulation status among ET patients with different driver gene mutations.Among ET patients,JAK2 mutation is most common.Compared with CALR group,the thrombotic rate,WBC and Fg significantly increase in JAK2 group,while PLT decrease.Compared with triple-negative group,the incidence of splenomegaly and HCT significantly increase.Compared with CALR group,Fg significantly increases but APTT decreases in triple-negative group.
5.Preliminary discussion on the appendix and inspection memorandum of investigational medicinal products of PIC/S
De LU ; Jing-Feng HU ; Wen-Yan XU ; Yu-Sheng PEI ; Xiao YE
The Chinese Journal of Clinical Pharmacology 2024;40(15):2301-2304
The National Medical Products Administration have become an official applicant of the Pharmaceutical Inspection Co-operation Scheme(PIC/S)in 2023,and the good manufacturing practice appendix and inspection memorandum are key documents of PIC/S.Based on the analysis of the history,framework and main contents of the appendix and inspection memorandum of PIC/S investigational medicinal products,this paper discusses the key contents of the appendix and inspection memorandum of PIC/S clinical trial drugs,and provides reference for the inspection work.
8.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
9.Population structure of food-borne Staphylococcus aureus in China.
Ya Hui GUO ; Zi Long HE ; Qing Long JI ; Hai Jian ZHOU ; Fan Liang MENG ; Xiao Feng HU ; Xiao Yue WEI ; Jun Cai MA ; Yu Hua YANG ; Wei ZHAO ; Li Jin LONG ; Xin WANG ; Jia Ming FAN ; Xiao Jie YU ; Jian Zhong ZHANG ; De HUA ; Xiao Mei YAN ; Hai Bin WANG
Chinese Journal of Epidemiology 2023;44(6):982-989
Objective: To understand the population structure of food-borne Staphylococcus (S.) aureus in China. Methods: Whole genome sequencing was used to analyze 763 food-borne S. aureus strains from 16 provinces in China from 2006 to 2020. Multilocus sequence typing (MLST), staphylococcal protein A gene (spa) typing, and staphylococcal chromosome cassettemec (SCCmec) typing were conducted, and minimum spanning tree based on ST types (STs) was constructed by BioNumerics 7.5 software. Thirty-one S. aureus strains isolated from imported food products were also included in constructing the genome phylogenetic tree. Results: A total of 90 STs (20 novel types) and 160 spa types were detected in the 763 S. aureus isolates. The 72 STs (72/90, 80.0%) were related to 22 clone complexes. The predominant clone complexes were CC7, CC1, CC5, CC398, CC188, CC59, CC6, CC88, CC15, and CC25, accounting for 82.44% (629/763) of the total. The STs and spa types in the predominant clone complexes changed over the years. The methicillin-resistant S. aureus (MRSA) detection rate was 7.60%, and 7 SCCmec types were identified. The ST59-t437-Ⅳa (17.24%, 10/58), ST239-t030-Ⅲ (12.07%, 7/58), ST59-t437-Ⅴb (8.62%, 5/58), ST338-t437-Ⅴb (6.90%, 4/58) and ST338-t441-Ⅴb (6.90%, 4/58) were the main types in MRSA strains. The genome phylogenetic tree had two clades, and the strains with the same CC, ST, and spa types clustered together. All CC7 methicillin sensitive S. aureus strains were included in Clade1, while 21 clone complexes and all MRSA strains were in Clade2. The MRSA strains clustered according to the SCCmec and STs. The strains from imported food products in CC398, CC7, CC30, CC12, and CC188 had far distances from Chinese strains in the tree. Conclusions: In this study, the predominant clone complexes of food-borne strains were CC7, CC1, CC5, CC398, CC188, CC59, CC6, CC88, CC15, and CC25, which overlapped with the previously reported clone complexes of hospital and community-associated strains in China, suggesting that close attention needs to be paid to food, a vehicle of pathogen transmission in community and food poisoning.
Humans
;
Staphylococcus aureus/genetics*
;
Methicillin-Resistant Staphylococcus aureus/genetics*
;
Multilocus Sequence Typing
;
Phylogeny
;
Staphylococcal Infections/epidemiology*
;
China/epidemiology*
10.Clinical efficacy observation of omalizumab on patients with moderate to severe allergic asthma for one year.
Yu XU ; De Xun ZHOU ; Ping HU ; Pei Hua GONG
Chinese Journal of Preventive Medicine 2023;57(3):427-432
To observe the symptom control, pulmonary function changes and safety of use of omalizumab in patients with moderate to severe allergic asthma for 1 year. A small sample self-controlled study before and after treatment was conducted to retrospective analysis involved 17 patients with moderate to severe asthma who received omalizumab therapy for 12 months in Peking University People's Hospital and Beijing Jishuitan Hospital from January 2020 to December 2021. The clinical symptoms and pulmonary function changes were compared before treatment, after 6 months and 12 months of treatment, and the clinical data such as the use of other drugs and adverse reactions were observed. Statistical data are collected using the median method, and non-parametric paired Wilcoxon analysis was used for pairwise comparison. Before treatment with omalizumab, the patients' FeNO value was 79(58, 121) ppb, and the total serum IgE was 228(150.5, 345.5) IU/ml. After 6 months of omalizumab therapy, the percent predicted value of the forced expiratory volume in 1 second (FEV1%) before inhaled bronchodilator increased from 86.70(82.65, 91.35)% to 90.90(87.70, 95.85)% (Z=-3.626, P<0.001). The FEV1%pred after inhaled bronchodilator increased from 92.60(85.75, 96.90)% to 94.30(89.95, 98.15)% (Z=-2.178, P=0.029). The absolute value of improvement in FEV1 decreased from 150(95, 210)ml to 50(20, 125) ml (Z=-2.796, P=0.005), and the improvement rate decreased from 6.60(3.80, 7.85)% to 1.90(0.75, 4.85)% (Z=-2.922, P=0.003). After 12 months of treatment, the FEV1%pred before inhaled bronchodilator further increased to 92.90 (91.60, 98.15)% (Z=-3.575, -2.818, and P<0.001, 0.005 compared with before treatment and 6 months after treatment, respectively). The FEV1%pred after inhaled bronchodilator increased to 96.80 (91.90, 101.25)% (Z=-3.622, -1.638, and P<0.001, 0.008 compared with before treatment and after 6 months of treatment, respectively). The absolute value of improvement in FEV1 was 70 (35, 120) ml (P=0.004, 0.842 before treatment and 6 months after treatment, respectively), and the improvement rate was 3.0(1.0, 5.0)% (Z=-2.960, -0.166, and P=0.003, 0.868, compared with before treatment and after 6 months of treatment, respectively). After 12 months of treatment, ACT increased from 13 (10.5, 18) before treatment to 24 (23, 25) (Z=-3.626,P<0.001). Only 1 patient experienced an injection site skin reaction during treatment. Therefore, after 6 months and 12 months of treatment with omalizumab, the patient's lung function improved and symptoms were relieved, which could effectively prevent the acute exacerbation of asthma. Omalizumab treatment is safe and well tolerated, and no effect on blood pressure and blood glucose was observed.
Humans
;
Omalizumab/therapeutic use*
;
Anti-Asthmatic Agents/therapeutic use*
;
Retrospective Studies
;
Bronchodilator Agents/therapeutic use*
;
Asthma/diagnosis*
;
Treatment Outcome

Result Analysis
Print
Save
E-mail