1.Nanomaterial-based Therapeutics for Biofilm-generated Bacterial Infections
Zhuo-Jun HE ; Yu-Ying CHEN ; Yang ZHOU ; Gui-Qin DAI ; De-Liang LIU ; Meng-De LIU ; Jian-Hui GAO ; Ze CHEN ; Jia-Yu DENG ; Guang-Yan LIANG ; Li WEI ; Peng-Fei ZHAO ; Hong-Zhou LU ; Ming-Bin ZHENG
Progress in Biochemistry and Biophysics 2024;51(7):1604-1617
Bacterial biofilms gave rise to persistent infections and multi-organ failure, thereby posing a serious threat to human health. Biofilms were formed by cross-linking of hydrophobic extracellular polymeric substances (EPS), such as proteins, polysaccharides, and eDNA, which were synthesized by bacteria themselves after adhesion and colonization on biological surfaces. They had the characteristics of dense structure, high adhesiveness and low drug permeability, and had been found in many human organs or tissues, such as the brain, heart, liver, spleen, lungs, kidneys, gastrointestinal tract, and skeleton. By releasing pro-inflammatory bacterial metabolites including endotoxins, exotoxins and interleukin, biofilms stimulated the body’s immune system to secrete inflammatory factors. These factors triggered local inflammation and chronic infections. Those were the key reason for the failure of traditional clinical drug therapy for infectious diseases.In order to cope with the increasingly severe drug-resistant infections, it was urgent to develop new therapeutic strategies for bacterial-biofilm eradication and anti-bacterial infections. Based on the nanoscale structure and biocompatible activity, nanobiomaterials had the advantages of specific targeting, intelligent delivery, high drug loading and low toxicity, which could realize efficient intervention and precise treatment of drug-resistant bacterial biofilms. This paper highlighted multiple strategies of biofilms eradication based on nanobiomaterials. For example, nanobiomaterials combined with EPS degrading enzymes could be used for targeted hydrolysis of bacterial biofilms, and effectively increased the drug enrichment within biofilms. By loading quorum sensing inhibitors, nanotechnology was also an effective strategy for eradicating bacterial biofilms and recovering the infectious symptoms. Nanobiomaterials could intervene the bacterial metabolism and break the bacterial survival homeostasis by blocking the uptake of nutrients. Moreover, energy-driven micro-nano robotics had shown excellent performance in active delivery and biofilm eradication. Micro-nano robots could penetrate physiological barriers by exogenous or endogenous driving modes such as by biological or chemical methods, ultrasound, and magnetic field, and deliver drugs to the infection sites accurately. Achieving this using conventional drugs was difficult. Overall, the paper described the biological properties and drug-resistant molecular mechanisms of bacterial biofilms, and highlighted therapeutic strategies from different perspectives by nanobiomaterials, such as dispersing bacterial mature biofilms, blocking quorum sensing, inhibiting bacterial metabolism, and energy driving penetration. In addition, we presented the key challenges still faced by nanobiomaterials in combating bacterial biofilm infections. Firstly, the dense structure of EPS caused biofilms spatial heterogeneity and metabolic heterogeneity, which created exacting requirements for the design, construction and preparation process of nanobiomaterials. Secondly, biofilm disruption carried the risk of spread and infection the pathogenic bacteria, which might lead to other infections. Finally, we emphasized the role of nanobiomaterials in the development trends and translational prospects in biofilm treatment.
2.Determination of L-synephrine in rat plasma by UHPLC-MS/MS method in pharmacokinetic study
Wei-Kang CHEN ; De-Hong LIU ; Yang-Bin ZHENG ; Qian-Ying WU ; Yi-Sheng YANG
The Chinese Journal of Clinical Pharmacology 2024;40(15):2256-2260
Objective To establish an ultra-high performance liquid phase tandem triple quadrupole mass spectrometry method for the determination of L-synephrine in rat plasma and to study its pharmacokinetics.Methods The plasma samples were precipitated by acetonitrile vortex,centrifuged,dried by nitrogen,dissolved by mobile phase,and then analyzed.Chromatographic column:Shiseido CAPCELL PAK CR(1∶4)column(2.0 mm × 150.0 mm,5 μm),temperature:25 ℃.Mobile phase:Acetonitrile:0.1%formic acid solution(containing 10 mmoL·L-1 ammonium formate)(73∶27)with flow rate:0.3 mL·min-1 and injection volume was 2 μL.The electrospray ion source ionization and positive ion multiple reaction monitoring mode were used for mass spectrometry detection,and biological sample methodology verification was carried out according to requirements.After intragastric administration with 5 mg·kg-1 dose of L-synephrine,blood samples were collected at different time points to investigate the pharmacokinetic characteristics of L-synephrine in rats.Results L-synephrine showed a good linear relationship in the range of 2-800 ng·mL-1,the lowest limit of quantification of L-synephrine was 2 ng·mL-1.Precision,extraction recovery,matrix effect,accuracy,dilution effect and residual effect all meet the requirements all met the requirements.The main pharmacokinetic parameters:Cmax were(464.83±76.68)ng·L-1,tmax were(0.67±0.26)h,t1/2z were(1.89±0.48)h,AUC0-t were(602.26±42.25)ng·mL-1·h-1,AUC0-∞ were(612.28±41.18)ng·mL-1·h-1.Conclusion The established ultra high performance liquid chromatography-tandem triple quadrupole mass spectrometry method for the determination of L-synephrine in rat plasma is simple and rapid,and can be used for the determination of L-synephrine in plasma.
3.A comparative study of chronic obstructive pulmonary disease models in rats established by exposure to cigarette smoke and motor vehicle exhaust
De-Fu LI ; Yuan-Yuan YE ; Hong-Ping ZHANG ; Run-Hua HOU ; Yao-Jun HE ; Chun-Yun ZHANG ; Jie-Ying HU ; Rui CHEN
Medical Journal of Chinese People's Liberation Army 2024;49(9):1038-1044
Objective To compare the fidelity of chronic obstructive pulmonary disease(COPD)models established using two methods:exposure to cigarette smoke(CS)and exposure to motor vehicle exhaust(MVE)in rats.Methods Twenty-four male SD rats were randomly divided into control,CS-exposed(CS),and MVE-exposed(MVE)groups,with 8 rats per group.Rats in CS and MVE groups were exposed to CS or MVE,respectively,to induce COPD models.After COPD model established,lung function of each group was assessed.Bronchoalveolar lavage fluid(BALF)was collected to measure inflammatory cell counts,levels of inflammatory cytokines interleukin-6(IL-6)and tumor necrosis factor(TNF)-α,and expression levels of mucin 5AC(MUC5AC).Lung tissue sections were stained with hematoxylin and eosin(HE)to observe pulmonary tissue and airway pathological changes.Periodic acid-Schiff(PAS)staining was used to detect goblet cell hyperplasia in airways.Results Compared with control group,rats in CS and MVE groups showed significantly increased inspiratory resistance(RI),total lung capacity(TLC),and lung static compliance(Cchord)(P<0.05),while expiratory flow parameters FEV50/FVC were significantly decreased(P<0.05).Compared with MVE group,rats in CS group had significantly higher RI,TLC,and Cchord(P<0.05),and lower FEV50/FVC(P<0.05).HE staining of lung tissues showed that mean linear intercept(MLI)was significantly higher in both CS and MVE groups compared with control group(P<0.05),with CS group having higher MLI than MVE group(P<0.05).BALF analysis revealed that white blood cells,neutrophils,macrophages,lymphocytes,IL-6,and TNF-α levels were significantly higher in both CS and MVE groups compared with control group(P<0.05),and inflammatory cell counts,IL-6,and TNF-α levels were higher in CS group compared with MVE group(P<0.05).PAS staining of lung tissues indicated that goblet cells in large airways were significantly increased in both CS and MVE groups compared with control group(P<0.05),with CS group showing higher goblet cell counts than MVE group(P<0.05).Expression levels of MUC5AC in BALF were significantly higher in both CS and MVE groups compared with control group(P<0.05),with CS group having significantly higher MUC5AC levels than MVE group(P<0.05).Conclusions Exposure to CS or MVE can establish a rat model of COPD,with CS exposure better mimicking characteristics of acute exacerbation of COPD compared to MVE exposure.
4.Antimicrobial resistance of bacteria from blood specimens:surveillance re-port from Hunan Province Antimicrobial Resistance Surveillance System,2012-2021
Hong-Xia YUAN ; Jing JIANG ; Li-Hua CHEN ; Chen-Chao FU ; Chen LI ; Yan-Ming LI ; Xing-Wang NING ; Jun LIU ; Guo-Min SHI ; Man-Juan TANG ; Jing-Min WU ; Huai-De YANG ; Ming ZHENG ; Jie-Ying ZHOU ; Nan REN ; An-Hua WU ; Xun HUANG
Chinese Journal of Infection Control 2024;23(8):921-931
Objective To understand the change in distribution and antimicrobial resistance of bacteria isolated from blood specimens of Hunan Province,and provide for the initial diagnosis and treatment of clinical bloodstream infection(BSI).Methods Data reported from member units of Hunan Province Antimicrobial Resistance Survei-llance System from 2012 to 2021 were collected.Bacterial antimicrobial resistance surveillance method was imple-mented according to the technical scheme of China Antimicrobial Resistance Surveillance System(CARSS).Bacteria from blood specimens and bacterial antimicrobial susceptibility testing results were analyzed by WHONET 5.6 soft-ware and SPSS 27.0 software.Results A total of 207 054 bacterial strains were isolated from blood specimens from member units in Hunan Province Antimicrobial Resistance Surveillance System from 2012 to 2021,including 107 135(51.7%)Gram-positive bacteria and 99 919(48.3%)Gram-negative bacteria.There was no change in the top 6 pathogenic bacteria from 2012 to 2021,with Escherichia coli(n=51 537,24.9%)ranking first,followed by Staphylococcus epidermidis(n=29 115,14.1%),Staphylococcus aureus(n=17 402,8.4%),Klebsiella pneu-moniae(17 325,8.4%),Pseudomonas aeruginosa(n=4 010,1.9%)and Acinetobacter baumannii(n=3 598,1.7%).The detection rate of methicillin-resistant Staphylococcus aureus(MRSA)decreased from 30.3%in 2015 to 20.7%in 2021,while the detection rate of methicillin-resistant coagulase-negative Staphylococcus(MRCNS)showed an upward trend year by year(57.9%-66.8%).No Staphylococcus was found to be resistant to vancomy-cin,linezolid,and teicoplanin.Among Gram-negative bacteria,constituent ratios of Escherichia coli and Klebsiella pneumoniae were 43.9%-53.9%and 14.2%-19.5%,respectively,both showing an upward trend(both P<0.001).Constituent ratios of Pseudomonas aeruginosa and Acinetobacter baumannii were 3.6%-5.1%and 3.0%-4.5%,respectively,both showing a downward trend year by year(both P<0.001).From 2012 to 2021,resistance rates of Escherichia coli to imipenem and ertapenem were 1.0%-2.0%and 0.6%-1.1%,respectively;presenting a downward trend(P<0.001).The resistant rates of Klebsiella pneumoniae to meropenem and ertapenem were 7.4%-13.7%and 4.8%-6.4%,respectively,presenting a downward trend(both P<0.001).The resistance rates of Pseudomonas aeruginosa and Acinetobacter baumannii to carbapenem antibiotics were 7.1%-15.6%and 34.7%-45.7%,respectively.The trend of resistance to carbapenem antibiotics was relatively stable,but has de-creased compared with 2012-2016.The resistance rates of Escherichia coli to the third-generation cephalosporins from 2012 to 2021 were 41.0%-65.4%,showing a downward trend year by year.Conclusion The constituent ra-tio of Gram-negative bacillus from blood specimens in Hunan Province has been increasing year by year,while the detection rate of carbapenem-resistant Gram-negative bacillus remained relatively stable in the past 5 years,and the detection rate of coagulase-negative Staphylococcus has shown a downward trend.
5.Identification of NUF2 expression pattern and its prognostic value of in breast cancer
Xue-Zhi LIU ; Bao-Ping ZHU ; Ying-De LI ; Qian CHEN
Chinese Journal of Current Advances in General Surgery 2024;27(9):699-703
Objective:To investigate the expression pattern and prognostic value of NUF2(Ndc80 kinetochore complex component)in breast cancer(BC).Methods:In the present study,the trancriptional level and survival information of NUF2 was analyzed by ONCOMINE dataset,bc-GenExMiner,Kaplan-Meier Plotter and TCGA.Results:NUF2 was highly expressed in BC com-pared with normal samples(P<0.05).In addition,the BC patients younger than 51 years old(P<0.0001),nodal metastasis(P=0.0168),with basal-like BC(P<0.0001),orestrogen receptor(ER)-negative(P<0.0001),progesterone receptor(PR)-negative(P<0.0001),human epidermal growth factor receptor-2(HER2)-positive(P<0.0001)and triple-negative BC(P<0.0001)pathological clas-sification have a higher transcriptional level of NUF2.Survival analysis indicated that patients with low expression level of NUF2 have a better relapse-free survival(RFS,HR=1.63,P<0.0001).Fur-ther anaysis revealed that the NUF2 expression was negatively related to the RFS of BC patients with ER-positive or PR-positive or HER2-negative pathological classification(HR=2.40,P=0.0015).Conclusion:NUF2 play an important role in BC and can be a potential prognostic bio-marker for ER-positive or PR-positive or HER2-negative BC patients.
6.Localization and anatomical measurement of lateral compression Ⅱscrew guide needle insertion point for pelvic fracture
Yong-Zheng CHEN ; Zhen-Hua HU ; Shao-Juan LI ; Xia-Cun LIANG ; Li-Kang HOU ; Shu-Liang ZHU ; Xin-Ying BAI ; Jin-Jian HE ; De-Meng YANG ; Zhi-Guo CHEN
Acta Anatomica Sinica 2024;55(6):728-733
Objective To measure the distance between the lateral compression Ⅱ(LC-Ⅱ)screw guide needle and the surrounding important structures around the anterior inferior iliac spine in pelvic fractures and to locate the needle point,so as to provide anatomical reference for clinical nail placement.Methods Totally 40 adult gross specimens of embalming were implanted with LC-Ⅱ screw guide needle under the surveillance of C-arm machine,and the specimens were dissected.The shortest distance between the insertion point and the lateral femoral cutaneous nerve,femoral nerve,femoral artery,femoral vein,anterior superior iliac spine and inguinal ligament was measured.The triangle was constructed between the insertion point,anterior superior iliac spine and inguinal ligament,and the exact location of the entry point was calculated.Results The average distance between the insertion point of the male needle and the femoral vein was(50.67±7.29)mm>the anterior superior iliac spine(43.83±7.58)mm>the femoral artery(38.35±6.63)mm>the femoral nerve(31.17±1.67)mm=the inguinal ligament(28.69±6.59)mm>the lateral femoral cutaneous nerve(7.98±3.81)mm.The mean distance between the insertion point of the female needle and the anterior superior iliac spine was(45.28±7.07)mm=femoral vein(43.72±6.89)mm>femoral artery(33.76±6.33)mm>femoral nerve(25.66±6.46)mm=inguinal ligament(23.22±5.00)mm>lateral femoral cutaneous nerve(8.97±4.76)mm.The projection distance of the entry point was 31.77 mm for men and 38.41 mm for women.The Angle b was 42.81°for men and 31.71° for women.Conclusion The lateral femoral cutaneous nerve is most vulnerable to injury when LC-Ⅱ screw is inserted,and the risk of injury has nothing to do with sex.The insertion point positioning method a and b made LC-Ⅱ screw placement quickly,safely and accurately,and reduced fluoroscopy time and frequency.
7.Overview of systematic reviews of Chinese herbal injections for sepsis.
Ying GAO ; Xiao-Kun YANG ; Zhao-Chen JI ; De-Hui PENG ; Xin-Yi XU ; Yi-Fan WU ; Kai LI ; Jun-Hua ZHANG ; Lu-Jia CAO
China Journal of Chinese Materia Medica 2023;48(7):1962-1975
In this study, an overview of systematic reviews/Meta-analysis(SR/MA) of Chinese herbal injections for sepsis was performed to provide references for clinical practice and promote the quality improvement of clinical evidence. Eight Chinese and English databases such as CNKI, Medline, and EMbase were electronically searched for SR/MA of Chinese herbal injections for sepsis from database inception to June 2022. AMSTAR 2, PRISMA 2020, and GRADE system, combined with Recommendations for Clinical Evidence Grading on Traditional Chinese Medicine Based on Evidence Body, were applied to evaluate the methodological quality, reporting quality, and evidence quality of the included articles. Twenty-seven articles of SR/MA were included, containing four Chinese herbal injections(Xuebijing Injection, Shenfu Injection, Shenmai Injection, and Shengmai Injection). AMSTAR 2 checklist showed that the methodological quality of the SR/MA ranged from moderate to very low. Item 2(prior study design) was the critical item with poor scores, and the non-critical items with poor scores were items 3(explain the selection of the study designs), items 10(report on the sources of funding), and items 16(conflicts of interest stated). In terms of PRISMA 2020, items in eight topics with complete reporting of missing>50%, including search strategy, certainty assessment, results of syntheses, certainty of evidence, registration and protocol, support, competing interests, availability of data, code and other materials. The included SR/MA involved 30 outcome indicators. Evidence quality of mortality, APACHE Ⅱ, and safety, the top three outcome indicators, was evaluated, and all of them were graded as the medium level. The lack of random allocation sequence, allocation concealment mechanism, blinding, and trial sample size was the main reason for the reduction of the evidence level. The available evidence shows that Chinese herbal injections can serve as an effective and safe adjunctive treatment for sepsis, which can reduce mortality, inhibit inflammation, improve coagulation function, and regulate immune function, tissue perfusion, and oxygenation in patients with sepsis. However, the quality of SR/MA was suboptimal, and more high-quality SR/MA is needed to provide evidence to support the efficacy and safety of Chinese herbal injections in the treatment of sepsis.
Humans
;
Injections
;
Medicine, Chinese Traditional
;
Research Design
;
Sepsis/drug therapy*
8.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
10.Highly Sensitive Poly-N-isopropylacrylamide Microgel-based Electrochemical Biosensor for the Detection of SARS-COV-2 Spike Protein.
Hao CHEN ; Zhi Yuan HOU ; Die CHEN ; Ting LI ; Yi Ming WANG ; Marcelo Andrade DE LIMA ; Ying YANG ; Zhen Zhong GUO
Biomedical and Environmental Sciences 2023;36(3):269-278
OBJECTIVE:
Late 2019 witnessed the outbreak and widespread transmission of coronavirus disease 2019 (COVID-19), a new, highly contagious disease caused by novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Consequently, considerable attention has been paid to the development of new diagnostic tools for the early detection of SARS-CoV-2.
METHODS:
In this study, a new poly-N-isopropylacrylamide microgel-based electrochemical sensor was explored to detect the SARS-CoV-2 spike protein (S protein) in human saliva. The microgel was composed of a copolymer of N-isopropylacrylamide and acrylic acid, and gold nanoparticles were encapsulated within the microgel through facile and economical fabrication. The electrochemical performance of the sensor was evaluated through differential pulse voltammetry.
RESULTS:
Under optimal experimental conditions, the linear range of the sensor was 10 -13-10 -9 mg/mL, whereas the detection limit was 9.55 fg/mL. Furthermore, the S protein was instilled in artificial saliva as the infected human saliva model, and the sensing platform showed satisfactory detection capability.
CONCLUSION
The sensing platform exhibited excellent specificity and sensitivity in detecting spike protein, indicating its potential application for the time-saving and inexpensive detection of SARS-CoV-2.
Humans
;
Microgels
;
Spike Glycoprotein, Coronavirus
;
COVID-19/diagnosis*
;
Gold
;
Metal Nanoparticles
;
SARS-CoV-2

Result Analysis
Print
Save
E-mail