1.Salidroside affects proliferation, invasion and apoptosis of cervical squamous cell carcinoma C33Acells through JAK2/STAT3 pathway
HUANG Jin ; LIU Furong ; WEN Ting ; TANG Qian ; XU Xiangmei ; LIAO Dazhong
Chinese Journal of Cancer Biotherapy 2020;27(5):522-527
[Abstract] Objective: To investigate the effects of salidroside on the proliferation, invasion and apoptosis of cervical squamous cell carcinoma C33A cells and explore its possible mechanism. Methods: C33A cells were divided into 4 groups: control group, low-dose group (salidroside 50 μg/mL), high-dose group (salidroside 150 μg/mL), and AG490 group (inhibitor of JAK2/STAT3 signaling pathway, 50 μmol/L). Effects of salidroside and AG490 on the proliferation, invasion and apoptosis of C33A cells were detected by MTT method, EdU labeling experiment, Transwell assay, Rh123 staining and Flow cytometry, respectively. Western blotting was used to detect the effects of salidroside and AG490 on the expressions of JAK2/STAT3 pathway-related proteins (p-JAK2, p-STAT3) and apoptosis-related proteins (Bax, Bcl-2, caspase-3) in C33A cells. Result: Compared with the control group, the proliferation and DNA synthesis as well as the invasion of C33Acells in the low-dose group were significantly inhibited (all P<0.05), while the apoptosis was significantly enhanced (P<0.05); in the meanwhile, the fluorescence intensity of Rh123 was significantly reduced (all P<0.05) and the membrane structure of C33A cells were destroyed; moreover, the expressions of p-JAK2, p-STAT3 and Bcl-2 were significantly decreased while the expressions of Bax and caspase-3 were significantly increased (all P<0.05). Compared with the low-dose group, the effects of high-dose salidroside and AG490 on the proliferation, invasion, apoptosis and related protein expressions in C33A cells were more significant (all P<0.05), but there was no difference between the high-dose group and the AG490 group. Conclusion: Salidroside can inhibit the proliferation and invasion of C33A cells and promote cell apoptosis. Its mechanism may be related to inhibition of JAK2/ STAT3 signaling pathway.
2.Multifunctional Cervical Health Care Pillow.
Zhaolan YANG ; Zengtao HOU ; Dazhong XU ; Yafei CAO ; Weidong LIU ; Peng SHANG
Chinese Journal of Medical Instrumentation 2018;42(5):341-344
Cervical spondylosis is due to degenerative cervical disc and its stimulation or oppression of the adjacent nerves, spinal cord, spinal artery and other tissue caused by clinical symptoms. The cervical spine is an anatomical structure with activity, while the pillow has a certain plastic fixation effect on the cervical spine anatomy. Therefore, the pillow not only plays a health role in the cervical spine, but also plays an important role in restoring the normal physiological curvature of the cervical spine. Based on this, a multi-functional cervical vertebra treatment pillow is designed, which not only has the functions of traction, maintaining different positions of the cervical spine, correcting the cervical curvature and equipment exercises, but also has the functions of voice broadcast and network data terminal.
3.Development of Software System for Artificial Joint Biomechanics.
Zengtao HOU ; Yuanju QU ; Zhaolan YANG ; Dazhong XU ; Qinli ZHANG ; Shuang ZHANG ; Peng SHANG
Chinese Journal of Medical Instrumentation 2018;42(5):330-331
In the research of artificial joint biomechanics, it is a common method in the world to evaluate the biomechanical properties of the implanted fixtures through experiments . The domestic research started late, and the corresponding testing software were lacking. There is still no special software. In this paper, an integrated software test system was designed and built based on the existing hardware system, including:hardware control, data collection, data save, data processing and display. It can directly show the 3D motion trajectory and the angle curve of joints. The system can accurately measure the relative motion angle value, external torque value, and inter pressure value of each joint. It has some reference significance for the development of the artificial joints' evaluation system.
4.Hardware System for the Test of Artificial Joint Biomechanics.
Zengtao HOU ; Zhaolan YANG ; Dazhong XU ; Qinli ZHANG ; Peng SHANG
Chinese Journal of Medical Instrumentation 2018;42(4):256-258
In the research of artificial joint biomechanics, it is a common method in the world to evaluate the biomechanical properties of the implanted fixtures through experiments . The domestic research started late, and the corresponding testing methods were lacking. There is still no unified standard. In this paper, a complete hardware test system was designed and built around the existing mechanical testing machine, including:binocular vision catcher, torque bearing clamp, film pressure sensor and so on. The system can accurately measure the relative motion angle value, external torque value, and inter pressure value of each joint. It has some reference significance for the forming and standardization of the artificial joints' evaluation system.
Biomechanical Phenomena
;
Joint Prosthesis
;
Motion
;
Pressure
;
Torque
5.Super-minimally invasive bilateral thoracoscopic extended thymectomy
Wei WANG ; Dazhong LIU ; Hao XU ; Yi LI ; Lei YANG ; Linyou ZHANG
Chinese Journal of Thoracic and Cardiovascular Surgery 2017;33(3):135-136
Objective To present the technique of super-minimally invasive bilateral thoracoscopic extended thymectomy,and evaluate the early clinical results by using of this technique.Methods Twenty-three patients with myasthenia gravis (MG) with thymoma underwent with super-minimally invasive bilateral thoracoscopic extended thymectomy in our institution between July 2014 and January 2016.Two operate-poles are 5mm trocar,one is three intercostal space at the anterior axillary line,and the other is four intercostal space at the midclavicular line.A 10 mm trocar is inserted through the 6th intercostal space in the mid axillary line.The perioperative variables and outcomes were collected and analysed retrospectively.Results In the 23 patients who underwent Super-Minimally invasive bilateral thoracoscopic extended thymectomy,the mean operation time was (163.2 ± 14.4) min and the average blood loss was (148.2 ± 39.5) ml.The chest tube duration was (4.14 ± 0.27) days.There were no mortalities.Conclusion Our preliminary report showed that Super-Minimally invasive bilateral thoracoscopic extended thymectomy for mediastinal tumour resection was a promising and safe technique with regard to short-term clinical outcome.
6.Prognostic significance of the number of dissected lymph nodes in Siewert typeⅡadenocarcinoma of the esophagogastric junction without lymphatic metastasis
Jinqian WANG ; Dazhong WEI ; Mingran XIE ; Shibin XU ; Dongchun MA
Chinese Journal of Oncology 2016;38(4):300-304
Objective To investigate the correlation between the number of dissected lymph nodes ( LNs) and the prognosis of patients with node?negative Siewert type ⅡAEG. Methods 248 patients with Siewert type Ⅱ AEG treated in our hospital between January 1998 and December 2008 were retrospectively assessed. All cases underwent left transthoracic subtotal esophagogastrectomy with conventional two?field lymphadenectomy, and were histopathologically proved to be without lymph node involvement. The prognostic impact of the number of dissected LNs was analyzed. Results The overall median survival time and the 1?, 3?, and 5?year overall survival rates were 64 months, 80. 4%, 60. 8% and 51. 0%, respectively. Cox regression showed that the number of dissected LNs and the depth of tumor invasion were independent prognostic factors. Patients with a high number of negative LNs had better overall survival than patients with a low number of negative LNs ( P<0.05) . The patients had better long?term survival outcomes with more than 10 LN dissected for cases with pT1 tumor ( P<0.001) , and so did those with more than 15 LN dissected for cases with pT2?3 tumor (P=0.003, 0.018, respectively). Conclusion The number of negative lymph nodes and the depth of tumor invasion are independent prognostic factors for node?negative Siewert type ⅡAEG, and adequate lymph node dissection can improve the long?term survival.
7.Prognostic significance of the number of dissected lymph nodes in Siewert typeⅡadenocarcinoma of the esophagogastric junction without lymphatic metastasis
Jinqian WANG ; Dazhong WEI ; Mingran XIE ; Shibin XU ; Dongchun MA
Chinese Journal of Oncology 2016;38(4):300-304
Objective To investigate the correlation between the number of dissected lymph nodes ( LNs) and the prognosis of patients with node?negative Siewert type ⅡAEG. Methods 248 patients with Siewert type Ⅱ AEG treated in our hospital between January 1998 and December 2008 were retrospectively assessed. All cases underwent left transthoracic subtotal esophagogastrectomy with conventional two?field lymphadenectomy, and were histopathologically proved to be without lymph node involvement. The prognostic impact of the number of dissected LNs was analyzed. Results The overall median survival time and the 1?, 3?, and 5?year overall survival rates were 64 months, 80. 4%, 60. 8% and 51. 0%, respectively. Cox regression showed that the number of dissected LNs and the depth of tumor invasion were independent prognostic factors. Patients with a high number of negative LNs had better overall survival than patients with a low number of negative LNs ( P<0.05) . The patients had better long?term survival outcomes with more than 10 LN dissected for cases with pT1 tumor ( P<0.001) , and so did those with more than 15 LN dissected for cases with pT2?3 tumor (P=0.003, 0.018, respectively). Conclusion The number of negative lymph nodes and the depth of tumor invasion are independent prognostic factors for node?negative Siewert type ⅡAEG, and adequate lymph node dissection can improve the long?term survival.
8.Establishment and Cluster Analysis of UPLC-MS Fingerprint of Shuanghuanglian Powder-injection
Yuanyuan GU ; Dianming LI ; Hongying XU ; Dazhong CHEN
Chinese Journal of Information on Traditional Chinese Medicine 2015;(6):91-94
Objective To establish the UPLC fingerprint of Shuanghuanglian powder-injection. Methods Acquity UPLCTM BEH C18 Column (2.1 mm × 50 mm, 1.7 μm) was established;mobile phase was acetonitrile and 0.1%formic acid with gradient elution;the flow rate was 0.3 mL/min;the column temperature was 40 ℃. Characteristic spectrum cluster of 13 batches of Shuanghuanglian powder-injection were analyzed, and Chinese Medicine Chromatographic Fingerprint Evaluation System (2004 A) was used to evaluate their quality. Results UPLC fingerprint common mode of 13 batches of Shuanghuanglian powder-injection was established. There were total 16 common spectrum peaks in the reference for comparison, and three main peaks were identified with better separation. The 13 batchs had good consistency, and the process was stable. Conclusion The method is rapid, efficient and can be used for full control of the quality of Shuanghuanglian powder-injection.
9.Application of new ERCC1 antibody for molecular diagnosis of platinum chemotherapy in non-small cell lung cancer
Jing LUO ; Meiqing XU ; Mingfa GUO ; Dazhong WEI ; Changqing LIU ; Xiangxiang SUN
China Oncology 2014;(2):135-138
Background and purpose:High expression of excision repair cross-complementing 1 (ERCC1) is related to resistance in patients treated with platinum-containing regimens. The ERCC1 antibody 8F1 was usually used in past studies, but it was found to have no-speciifcity recently. This study aimed to investigate the predictive role of a new ERCC1 antibody 4F9 to platinum chemotherapy in non-small cell lung cancer (NSCLC) patients. Methods:Expression of ERCC1 was detected using antibody 4F9 by immunohistochemistry (IHC) in 72 NSCLC tissues. The relationship between the expression of ERCCl and the clinical pathological parameters, the efficacy of platinum chemotherapy and overall survival of patients were explored by statistical analysis. Results: The high expression of ERCCl protein was 55.5%in 72 cases. There was no signiifcant correlation between the ERCC1 expression with gender, age, pathological type, clinical stage and lymphatic metastasis (P>0.05). Patients with low expression of ERCC1 had signiifcantly higher response rates to platinum chemotherapy, longer median survival time and 2-years survival rate comparing with those with high expression of ERCC1 (62.5%vs 37.5%;22.9 vs 18.4 month;46.9%vs 37.5%), respectively (P<0.05). Conclusion:The expression analysis of ERCC1 using new ERCC1 antibody 4F9 by IHC method is helpful to assign chemotherapeutic regimen, and guide individual platinum chemotherapy for post-operation patients.
10.Application of contrast-enhanced ultrasound in preoperative diagnosis of anal fistula
Dazhong ZOU ; Yifeng YU ; Danping YAN ; Li LIU ; Qin XUE ; Yufang XU ; Yuying TANG ; Hai GONG
Chinese Journal of Ultrasonography 2010;19(12):1051-1053
Objective To evaluate the clinical value of contrast-enhanced ultrasound (CEUS) in preoperative diagnosis of anal fistula. Methods Forty-five patients with fistula in ano were evaluated by physical examination, then CEUS were peformed by injecting SonoVue through the external opening to enhance the detection of the fistulous track and the internal opening. The results of CEUS were matched with surgical features to establish their accuracy in preoperative assessment of anal fistula. Results Simple typing fistula was found in 19 of 45 patients and 26 patients had complex fistulas. The accurate diagnostic rates by conventional ultrasound of simple typing fistula and complex fistulas were 89. 5% and 61.5%,respectively,the accurate diagnostic rates by CEUS of simple typing fistula and complex fistulas were 94. 7% and 92.3%, respectively, there was no significant difference between conventional ultrasound and CEUS about simple typing fistula( P >0.05), and there was significant difference about complex fistulas ( P <0. 05). Conclusions CEUS has a good visibility and accurate rate for diagnosis of anal fistula,It plays an important role for operation.

Result Analysis
Print
Save
E-mail