1.Drainless Parotidectomies versus Conventional Parotidectomies: Randomised Control Study on Efficacy and Safety.
Dennis Yk CHUA ; Christopher Hk GOH
Annals of the Academy of Medicine, Singapore 2016;45(11):513-515
Adenolymphoma
;
surgery
;
Adenoma, Pleomorphic
;
surgery
;
Compression Bandages
;
Drainage
;
Facial Nerve Diseases
;
epidemiology
;
Female
;
Fibrin Tissue Adhesive
;
therapeutic use
;
Health Care Costs
;
Hospitalization
;
economics
;
statistics & numerical data
;
Humans
;
Length of Stay
;
Male
;
Middle Aged
;
Parotid Gland
;
surgery
;
Parotid Neoplasms
;
surgery
;
Postoperative Complications
;
epidemiology
;
Singapore
;
epidemiology
;
Tissue Adhesives
;
therapeutic use
2.Application of Video Monitoring System in Intensive Care Unit.
Yong QIN ; Lianying GONG ; Jiahui YU ; Mengmeng SHANG
Chinese Journal of Medical Instrumentation 2015;39(6):400-402
The system applies H.264 compression coding technology and uses TCP/IP protocol to transmit data. It transfers the video information, cardio-spectrograms, blood oxygen and blood pressure spectrum to the medical area and the visiting area for families that outside of ICU intensively. The patients' information is transmitted to the medical staffs intensively, then making the relevant backups, so people can avoid many potential medical disputes.
Blood Pressure
;
Data Compression
;
Heart
;
Humans
;
Intensive Care Units
;
Monitoring, Physiologic
;
instrumentation
;
Technology
;
Video Recording
3.Research and realization of signal processing algorithms based on FPGA in digital ophthalmic ultrasonography imaging.
Simin FANG ; Sheng ZHOU ; Xiaochun WANG ; Qingsheng YE ; Ling TIAN ; Jianjun JI ; Yanqun WANG
Chinese Journal of Medical Instrumentation 2015;39(1):1-4
OBJECTIVETo design and improve signal processing algorithms of ophthalmic ultrasonography based on FPGA.
METHODSAchieved three signal processing modules: full parallel distributed dynamic filter, digital quadrature demodulation, logarithmic compression, using Verilog HDL hardware language in Quartus II.
RESULTSCompared to the original system, the hardware cost is reduced, the whole image shows clearer and more information of the deep eyeball contained in the image, the depth of detection increases from 5 cm to 6 cm.
CONCLUSIONThe new algorithms meet the design requirements and achieve the system's optimization that they can effectively improve the image quality of existing equipment.
Algorithms ; Data Compression ; Diagnostic Imaging ; Ophthalmology ; Signal Processing, Computer-Assisted ; Ultrasonography
4.Influence of Image Compression on the Interpretation of Optical Coherence Tomography in Diabetic Macular Edema.
Sunah KANG ; Young Suk CHANG ; Jong Woo KIM ; Chul Gu KIM ; Tae Gon LEE ; Jae Hui KIM
Journal of the Korean Ophthalmological Society 2014;55(9):1320-1326
PURPOSE: To evaluate the influence of image compression on optical coherence tomography (OCT) images in eyes with diabetic macular edema (DME). METHODS: Twenty eyes of 30 patients diagnosed with DME were included in this retrospective observational case series. Horizontal OCT scans centered at the center of the fovea were conducted using spectral-domain OCT (Spectral OCT/SLO(R)). The images were exported to Tag Image File Format (TIFF) and then transformed to 10, 5, and 1 quality of Joint Photographic Experts Group (JPEG) format using Photoshop. OCT images were taken before and after intravitreal bevacizumab injection. The presence of intraretinal fluid, foveolar detachment, and photoreceptor inner segment/outer segment (IS/OS) disruption were evaluated in each image. RESULTS: The mean (+/- standard deviation) size of TIFF images and 10, 5 and 1 quality JPEG images were 1712.0, 183.3 +/- 6.8, 90.9 +/- 4.3, 42.8 +/- 1.4 kilobytes (KB), respectively, before the injection and 1712.0, 189.5 +/- 9.1, 94.9 +/- 5.6, 43.4 +/- 1.8 KB, respectively, after the injection. The presence of intraretinal fluid, foveolar detachment, and photoreceptor IS/OS disruption identified in TIFF images was also identified in the compressed JPEG images. CONCLUSIONS: Quality of retinal OCT image did not influence the estimation of DME despite the JPEG image being compressed to approximately 1/40 of the original TIFF image size.
Data Compression*
;
Humans
;
Joints
;
Macular Edema*
;
Retinaldehyde
;
Retrospective Studies
;
Tomography, Optical Coherence*
;
Bevacizumab
5.An improved prior image constrained compressed sensing reconstruction for low-dose computed tomography.
Hong GUO ; Zhaoying BIAN ; Jing HUANG ; Jianhua MA
Journal of Southern Medical University 2013;33(11):1620-1623
Low-dose computed tomography (CT) reconstruction has become the focus of X-ray CT imaging study. In this paper, we propose an improved prior image constrained compressed sensing (PICCS) reconstruction approach. A penalized weighted least-squares approach was adopted to realize the line integral projection (sinogram) data restoration, followed by filtered back-projection (FBP) of the restored sinogram data for image reconstruction. Finally, the FBP image as the prior image was used for PICCS approach for dose reduction. Qualitative and quantitative evaluations were carried out with computer simulation. The results showed that the present approach yielded noticeable gains over the original PICCS approach for dose reduction in terms of noise-induced artifacts suppression and edge detail preservation.
Algorithms
;
Computer Simulation
;
Data Compression
;
methods
;
Image Processing, Computer-Assisted
;
methods
;
Least-Squares Analysis
;
Phantoms, Imaging
;
Radiation Dosage
;
Signal-To-Noise Ratio
;
Tomography, X-Ray Computed
;
methods
6.Realization of DICOM medical image compression technology.
Chenxi WANG ; Quan WANG ; Haiping REN
Chinese Journal of Medical Instrumentation 2013;37(3):178-181
This paper introduces the implement method of DICOM medical image compression technology, The image part of DICOM files are extracted and converted to BMP format. The non-image information in DICOM file are stored into the text. When the final image of JPEG standard and non-image information are encapsulated to DICOM format images, it realizes the compression of medical image, which is beneficial to the image storage and transmission.
Data Compression
;
methods
;
Image Processing, Computer-Assisted
;
methods
;
Software
7.Role of Intraoperative Red Cell Salvage and Autologus Transfusion in Metastatic Spine Surgery: A Pilot Study and Review of Literature.
Harinder GAKHAR ; Munzer BAGOURI ; Rajendranath BOMMIREDDY ; Zdenek KLEZL
Asian Spine Journal 2013;7(3):167-172
STUDY DESIGN: Prospective cohort study. PURPOSE: There has been no research examining the use of intraoperative cell salvage during metastatic spinal surgery. The present work is a pilot study investigating the role of cell salvage during metastatic spine surgery. OVERVIEW OF LITERATURE: There is no spinal literature about role of cell salvage and autologus transfusion in metastatic spinal cancer. METHODS: Sixteen spinal metastases patients who received red cell salvage using a leucocyte depletion filter were enrolled. Of these, ten patients who received salvaged blood transfusion were included in the final analysis. Data collection involved looking at the case notes, operating room records and the prospectively updated metastatic spinal cancer database maintained in the spinal department. Cell salvage data was recovered from the central cell salvage database maintained in the anesthetic department. RESULTS: Amount of salvaged blood ranged from 120 to 600 mL (average, 318 mL). The average drop in hemoglobin was 1.65 units (range, 0.4-2.7 units). Three patients (30%) required postoperative allogenic blood transfusion. The average follow up was 9.5 months (range, 6-6 months). One patient developed new lung metastasis, at seven months. No patient developed new liver metastases. Preoperatively, six patients had diffuse skeletal metastases. Of this subgroup, three developed new skeletal metastases. No cases showed any wound related problems in the postoperative period. CONCLUSIONS: In our study transfusion of intraoperatively salvaged blood did not result in disseminated metastatic cancer. We would suggest that red cell salvage might have a role during metastatic spine surgery.
Blood Transfusion
;
Cohort Studies
;
Data Collection
;
Follow-Up Studies
;
Hemoglobins
;
Humans
;
Liver
;
Lung
;
Neoplasm Metastasis
;
Operating Rooms
;
Operative Blood Salvage
;
Pilot Projects
;
Prospective Studies
;
Spinal Cord Compression
;
Spine
8.The research of decoded compression arithmetic for medical high-frequency ultrasound coded excitation imaging.
Sheng ZHOU ; Xiaochun WANG ; Jun YANG ; Yanqun WANG
Chinese Journal of Medical Instrumentation 2011;35(6):409-413
This paper combined the coded excitation with the technique of ophthalmic high-frequency ultrasonic imaging, and raised a new high-velocity data detection and signal processing method. 16 bit Golay complementarity sequences were produced by FPGA, which excited the probe to produce ultrasonic waves. Data detection circuit achieved the digitalized of the 15 MHz high-frequency ultrasonic echo signals in real time. Sampling rate was 120MHz, and sampling bit was 14 bit. Decoded compression arithmetic was realized by FPGA in real time, in which A code compression was alternated with B code compression. The return echo was correlated with the corresponding decode filter A and filter B respectively, and then the echo was delayed and summed to complete the decoding process. The experiment indicated that coded excitation can effectively increase the range of mainlobe and decrease the range of sidelobe. This technique can effectively raise the signal-to-noise ratio, and has significant research value in advancing the ophthalmic ultrasonic image quality and raising the safety of the equipment.
Data Compression
;
Diagnostic Techniques, Ophthalmological
;
Signal Processing, Computer-Assisted
;
Ultrasonography
;
methods
9.An algorithm for quick fitting of linear approximation distance thresholding.
Journal of Biomedical Engineering 2010;27(1):20-23
In this paper is proposed a new method that approximates line segment with angle to control line as a basis for improving radial fitting. Experiments on selected records from the Massachusettes Institute of Technology and Boston's Beth Isral Hospital (MIT-BIH) arrhythmia database have revealed that the improved algorithm not only increases computation quantity, but also improves approximating quality and potentiates Real-time application of the linear approximation distance thresholding (LADT).
Algorithms
;
Data Compression
;
Electrocardiography
;
methods
;
Humans
;
Signal Processing, Computer-Assisted
10.A research on JPEG2000 used in DICOM store service.
Luzhou LI ; Wei ZHANG ; Changjian TANG ; Haoyang XING
Journal of Biomedical Engineering 2009;26(2):225-229
In view of the fact that the large quantities of data contained in the medical image do not have a favorable setting for effective storage and transmission in the existing network, we have developed a JPEG2000 DICOM image compression kit using VC++, and we have realized the medical image storage service according to the C-STORE rule of DICOM standard. The results showed that the medical image processed by JPEG2000 compression algorithm not only greatly saved the storage space, but also reduced the band width needed by transmission. In this paper is discussed the DICOM image compressed by JPEG2000 compression algorithm in DICOM strorage service application. The significance of JPEG2000 compression algorithm in the development of picutre archiving and communication systems (PACS) and telemedicine is also explained.
Algorithms
;
Computer Communication Networks
;
instrumentation
;
Data Compression
;
Diagnostic Imaging
;
instrumentation
;
Humans
;
Image Processing, Computer-Assisted
;
Medical Records Systems, Computerized

Result Analysis
Print
Save
E-mail