1.Delayed Diagnosis of Brachial Plexus Injury Due to Vertebral Arteriovenous Fistula Caused by Blunt Trauma
Jin Gee PARK ; Jae Yeon KIM ; Young Sook PARK ; Hyun Jung CHANG ; Eun Sol CHO ; Da Hye KIM ; Jeong Hwan LEE ; Se Jin KIM
Journal of Electrodiagnosis and Neuromuscular Diseases 2025;27(1):18-22
Vertebral arteriovenous fistula (VAVF) is a rare lesion characterized by an abnormal connection between the extracranial vertebral artery and the surrounding venous plexus. It typically arises due to penetrating injury, although it can occasionally result from blunt trauma. Brachial plexus injury (BPI) is also infrequently associated with VAVF. We present a rare case of VAVF caused by blunt trauma, which resulted in BPI. The patient, who had previously sustained a C2 fracture and C2–3 myelopathy from a bicycle accident, presented with new-onset weakness in the right upper extremity. His previous clinical history led to an initial suspicion of either an exacerbation of a pre-existing lesion or a shoulder injury. However, electromyography indicated that the weakness was due to BPI. Further evaluations later revealed VAVF to be the primary cause of the BPI. VAVF must be recognized as a rare potential reason for BPI, as timely intervention is essential for improving patient recovery and prognosis.
2.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
3.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
4.Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea
Hyundam GU ; Suyoung LEE ; Sol KIM ; Hye-Lim JANG ; Da-Woon CHOI ; Kyu Seok KIM ; Yu Ri SHIN ; Dae Young CHEUNG ; Bo-In LEE ; Jin Il KIM ; Han Hee LEE
Clinical Endoscopy 2024;57(6):790-797
Background/Aims:
Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement.
Methods:
All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings.
Results:
The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved.
Conclusions
This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
5.Early nutritional support for inpatients reduces admission rates to intensive care units in Korea: a single-center case-control study
Hyun Suk KIM ; Jae Do YANG ; Se Wung HAN ; Mi Rin LEE ; Da-Sol KIM ; Sejin LEE ; Seon-Hyeong KIM ; Chan-Young KIM
Annals of Clinical Nutrition and Metabolism 2024;16(2):57-65
Purpose:
Early nutritional support (ENS) for critically ill patients is promoted by many studies. However, there is a lack of data evaluating its necessity in general wards. This study aims to determine the impact of ENS on patients in general wards.
Methods:
Patients aged 18 and above, admitted to the Jeonbuk National University Hospital in Jeonju from January 2020 to December 2020, who were eligible for nutritional support and hospitalized for at least 7 days were included in the study. We divided the patients into two groups: the ENS group, who received nutritional support within 48 hours of admission, and the control group, who received it after 48 hours.
Results:
Among 1,077 patients, 146 met the inclusion criteria. The ENS group (n=38) and the control group (n=108) were compared retrospectively. There was a significant age difference between the two groups (P=0.028). The admission ratio to the intensive care unit (ICU) in the ENS group was significantly lower than that in the control group (10.2% vs.26.3%, P=0.019). The calorie support rate (%) and protein support rate (%) in the ENS group were significantly higher than in the control group (50.12%±23.30% vs. 38.56%±18.02%, P=0.006; 44.61%±25.07% vs. 32.07%±22.76%, P=0.002, respectively). After propensity score matching, the ENS was significantly associated with ICU low admissions (odds ratio 0.08, 95% confidence interval 0.01–0.69, P=0.022).
Conclusion
A future multi-center study considering underlying diseases is needed to provide additional scientific evidence to support the effects of ENS.
6.Effect of Pre- and Post-Dialysis Exercise on Functional Capacity Using Portable Ergometer in Chronic Kidney Disease Patients
Tae-Seok CHAE ; Da-Sol KIM ; Myoung-Hwan KO ; Yu Hui WON
Annals of Rehabilitation Medicine 2024;48(4):239-248
Objective:
To assess whether performing exercises during hemodialysis reduces the risk of developing intradialytic hypotension and enhances exercise capacity in patients with chronic kidney disease.
Methods:
This study included patients aged ≥18 years undergoing hemodialysis. Participants performed exercises using a portable lower extremity ergometer during hemodialysis sessions for 3 weeks. Data regarding walking distance, knee strength, quality of life, fat-free mass, arterial pressure, blood pressure, heart rate, frequency of intradialytic hypotension, fatigue, and duration of hemodialysis were collected and analyzed.
Results:
Significant improvements in walking distance and knee strength were observed following the implementation of exercise training during hemodialysis. Although there was no significant reduction in the frequency of intradialytic hypotension, a decreasing trend was noted. Other parameters such as quality of life and fatigue did not show significant changes.
Conclusion
Using a portable ergometer during hemodialysis improved exercise capacity and knee strength in patients with chronic kidney disease. There was a trend toward reduced intradialytic hypotension, suggesting potential cardiovascular benefits. Further research with larger sample sizes is needed to confirm these findings.
7.Changes in Lower Extremity Muscle Quantity and Quality in Patients with Subacute Stroke
Da Hye KIM ; Eun Sol CHO ; Young Sook PARK ; Hyun Jung CHANG ; Jin Gee PARK ; Jae Yeon KIM ; Jeong Hwan LEE
Annals of Rehabilitation Medicine 2023;47(6):493-501
Objective:
To analyze the changes in muscle mass and quality with time on the paretic and non-paretic sides in subacute stroke patients and identify correlations between the variation of muscle mass and quality and lower limb functions.
Methods:
Thirty hemiplegia patients diagnosed with stroke participated in this study. To evaluate poststroke muscle changes, longitudinal measurement of muscle mass and quality was conducted with bilateral lower limbs. The elastic shear modulus was measured using shear wave elastography and muscle thickness (MT) of rectus femoris, vastus intermedius, vastus lateralis (VL), vastus medialis, tibialis anterior, and gastrocnemius (GCM) muscles. Functional evaluation was performed using Berg Balance Scale (BBS), Five Times Sit to Stand Test (FTSST). Follow-up was performed at discharge. The muscle mass and quality were compared according to time. We analyzed whether muscle quantity and quality were related to function.
Results:
MT demonstrated no significant change with time. The elastic shear modulus increased significantly in the paretic VL and GCM muscles and did not change significantly in the muscles on the non-paretic side. Correlation analysis detected that elastic shear modulus in the VL has a cross-sectional negative relationship between BBS and positive relationship between FTSST. There were significant correlation between variation of FTSST and the variation of the elastic shear modulus in VL.
Conclusion
Only paretic VL and GCM muscle quality changed in subacute stroke patients and muscle’s property related to lower limb functions. Therefore, the lower extremity requires an approach to muscle quality rather than quantity for subacute stroke patients.
8.Kennedy’s Disease with Chronic Low Back Pain and Muscle Weakness
Jae Yeon KIM ; Young Sook PARK ; Hyun Jung CHANG ; Jin Gee PARK ; Eun Sol CHO ; Da Hye KIM ; Jeong Hwan LEE ; Se Jin KIM
Clinical Pain 2023;22(2):127-130
Kennedy’s disease (KD) or bulbospinal muscular atrophy is an uncommon x-linked recessive genetic disorder. Its diagnosis is challenging due to its wide array of clinical manifestations and difficulty distinguishing it from other motor neuron diseases.Thus, diagnosis is confirmed through DNA testing. 52-year-old male patient presented to the hospital with chronic low back pain (LBP) and muscle weakness. The patient had mild weakness in some proximal muscles, increased deep tendon reflex.Lumbar spine magnetic resonance imaging (MRI) showed degenerative changes. Motor nerve conduction test results showed close to the normal. Sensory nerve conduction test results showed decreased latency and amplitude in most nerves. Needle electromyography revealed fasciculation potentials, diffuse fibrillation potentials, and positive sharp waves were detected. Thus, molecular genetic testing was performed. Consequently, KD was diagnosed. These results suggest the importance of detailed history taking and neurological examination even for patients with chronic LBP to rule out severe diseases.
9.Short-Term Effectiveness of Oral Nirmatrelvir/Ritonavir Against the SARS-CoV-2 Omicron Variant and Culture-Positive Viral Shedding
Eunyoung LEE ; Sehee PARK ; Jae-Phil CHOI ; Min-Kyung KIM ; Eunmi YANG ; Sin Young HAM ; Seungjae LEE ; Bora LEE ; Jeong-Sun YANG ; Byoung Kwon PARK ; Da Sol KIM ; So-Young LEE ; Joo-Yeon LEE ; Hee-Chang JANG ; Jaehyun JEON ; Sang-Won PARK
Journal of Korean Medical Science 2023;38(8):e59-
Background:
Information on the effectiveness of nirmatrelvir/ritonavir against the omicron is limited. The clinical response and viral kinetics to therapy in the real world need to be evaluated.
Methods:
Mild to moderate coronavirus disease 2019 (COVID-19) patients with risk factors for severe illness were prospectively enrolled as a treatment group with nirmatrelvir/ritonavir therapy versus a control group with supportive care. Serial viral load and culture from the upper respiratory tract were evaluated for seven days, and clinical responses and adverse reactions were evaluated for 28 days.
Results:
A total of 51 patients were analyzed including 40 in the treatment group and 11 in the control group. Faster symptom resolution during hospitalization (P= 0.048) was observed in the treatment group. Only minor adverse reactions were reported in 27.5% of patients. The viral load on Day 7 was lower in the treatment group (P = 0.002). The viral culture showed a positivity of 67.6% (25/37) vs. 100% (6/6) on Day 1, 0% (0/37) vs. 16.7 (1/6) on Day 5, and 0% (0/16) vs. 50.0% (2/4) on Day 7 in the treatment and control groups, respectively.
Conclusions
Nirmatrelvir/ritonavir against the omicron was safe and resulted in negative viral culture conversion after Day 5 of treatment with better symptomatic resolution.
10.Efficacy of an Integrated Training Device in Improving Muscle Strength, Balance, and Cognitive Ability in Older Adults
Choong-Hee ROH ; Da-Sol KIM ; Gi-Wook KIM ; Yu-Hui WON ; Sung-Hee PARK ; Jeong-Hwan SEO ; Myoung-Hwan KO
Annals of Rehabilitation Medicine 2021;45(4):314-324
Objective:
To determine the effects of an integrated training device for strength and balance on extremity muscle strength, postural balance, and cognition in older adults using a combination with various rehabilitation training games, in which balance, strength, and cognitive training were configured in a single device.
Methods:
This prospective study included 20 healthy participants aged 65–85 years. Participants trained for 30 minutes daily, 3 days weekly, for 6 weeks with an integrated training device for strength and balance (SBT-120; Man&Tel Inc., Gumi, Korea). Main outcomes were measured using the Korean Mini-Mental State Examination (K-MMSE), Korean version of the Montreal Cognitive Assessment (K-MoCA), Timed Up and Go Test (TUG), Functional Reach Test (FRT), Berg Balance Scale (BBS), and Manual Muscle Test. Measurements were taken at three time points: T0 (pretreatment), T1 (immediately after treatment), and T2 (4 weeks after treatment).
Results:
All 20 patients completed the training, and TUG, FRT, and BBS scores significantly improved at T1 and T2 compared to T0. Mean TUG scores decreased by 0.99±2.00 at T1 and 1.05±1.55 at T2 compared to T0. Mean FRT scores increased by 6.13±4.26 at T1 and 6.75±4.79 at T2 compared to T0. BBS scores increased by 0.60±0.94 at T1 and 0.45±1.15 at T2 compared to T0. Moreover, muscle strength and cognition (K-MMSE and K-MoCA scores) increased after training.
Conclusion
Our findings suggest that an integrated training device for strength and balance can be a safe and useful tool for older adults.

Result Analysis
Print
Save
E-mail