2.Levels of plasma Quaking and cyclooxygenase-2 predict in-stent restenosis in patients with coronary artery disease after percutaneous coronary intervention.
Ping WANG ; Yuanyuan KUANG ; Yubo LIU ; Yinzhuang ZHANG ; Haodong GAO ; Qilin MA
Journal of Central South University(Medical Sciences) 2022;47(6):739-747
OBJECTIVES:
Percutaneous coronary intervention (PCI) is one of the important methods for the treatment of coronary artery disease (CAD). In-sent restenosis (ISR) after PCI for patients suffered from CAD is considered to be an essential factor affecting long-term outcomes and prognosis of this disease. This study aims to investigate the correlation between plasma Quaking (QKI) and cyclooxygenase-2 (COX-2) levels and ISR in patients with CAD.
METHODS:
A total of 218 consecutive CAD patients who underwent coronary angiography and coronary arterial stenting from September 2019 to September 2020 in the Department of Cardiology of Xiangya Hospital of Central South University were enrolled in this study, and 35 matched individuals from the physical examination center were served as a control group. After admission, clinical data of these 2 groups were collected. Plasma QKI and COX-2 levels were measured by enzyme linked immunosorbent assay (ELISA). Follow-up angiography was performed 12 months after PCI. CAD patients were divided into a NISR group (n=160) and an ISR group (n=58) according to the occurrence of ISR based on the coronary angiography. The clinical data, coronary angiography, and stent features between the NISR group and the ISR group were compared, and multivariate logistic regression was used to explore the factors influencing ISR. The occurrence of major adverse cardiovascular events (MACE) 1 year after operation was recorded. Fifty-eight patients with ISR were divided into an MACE group (n=24) and a non-MACE group (n=34), classified according to the occurrence of MACE, and the plasma levels of QKI and COX-2 were compared between the 2 groups. Receiver operating characteristic (ROC) curves were utilized to analyze the diagnostic value of plamsa levels of QKI and COX-2 for ISR and MACE occurrences in patients after PCI.
RESULTS:
Compared with control group, plasma levels of QKI and COX-2 in the CAD group decreased significantly (all P<0.001). Compared with the NISR group, the plasma levels of QKI and COX-2 also decreased obviously in the ISR group (all P<0.001), while the levels of high sensitivity C-reactive protein (hs-CRP) and glycosylated hemoglobin (HbAlc) significantly increased (all P<0.001). The level of COX-2 was negatively correlated with hs-CRP (r=-0.385, P=0.003). Multivariate logistic regression analysis showed that high level of plasma QKI and COX-2 were protective factors for in-stent restenosis after PCI, while hs-CRP was a risk factor. ROC curve analysis showed that the sensitivity and specificity of plasma QKI for evaluating the predictive value of ISR were 77.5% and 66.5%, respectively, and the sensitivity and specificity of plasma COX-2 for evaluating the predictive value of ISR were 80.0% and 70.7%, respectively. The sensitivity and specificity of plasma QKI combined with COX-2 for evaluating the predictive value of ISR were 81.3% and 74.1%, respectively. The sensitivity and specificity of plasma QKI for evaluating the prognosis of ISR were 75.0% and 64.7%, respectively. The sensitivity and specificity of plasma COX-2 for evaluating the prognosis of ISR were 75.0% and 70.6%, respectively. The sensitivity and specificity of plasma QKI combined with COX-2 for prognostic evaluation of ISR were 81.7% and 79.4%, respectively. The sensitivity and specificity of plasma COX-2 combined with QKI for evaluating ISR and MACE occurrences in patients after PCI were better than those of COX-2 or QKI alone (P<0.001).
CONCLUSIONS
High level of plasma QKI and COX-2 might be a protective factor for ISR, which can also predict ISR patient's prognosis.
C-Reactive Protein/analysis*
;
Constriction, Pathologic/etiology*
;
Coronary Angiography/adverse effects*
;
Coronary Artery Disease
;
Coronary Restenosis/therapy*
;
Cyclooxygenase 2
;
Humans
;
Percutaneous Coronary Intervention/adverse effects*
;
Risk Factors
;
Stents/adverse effects*
3.Cut-off values of lesion and vessel quantitative flow ratio in de novo coronary lesion post-drug-coated balloon therapy predicting vessel restenosis at mid-term follow-up.
Pei-Na MENG ; Bin LIU ; Long-Bo LI ; De-Lu YIN ; Heng ZHANG ; De-Feng PAN ; Wei YOU ; Zhi-Ming WU ; Xiang-Qi WU ; Lei ZHAO ; Zhi-Bo LI ; Jin-Peng WANG ; Zhi-Hui WANG ; Tian XU ; Xiao-Yu HUANG ; Ruo-Nan GAO ; Fei YE
Chinese Medical Journal 2021;134(12):1450-1456
BACKGROUND:
Drug-coated balloons (DCBs) have emerged as potential alternatives to drug-eluting stents in specific lesion subsets for de novo coronary lesions. Quantitative flow ratio (QFR) is a method based on the three-dimensional quantitative coronary angiography and contrast flow velocity during coronary angiography (CAG), obviating the need for an invasive fractional flow reserve procedural. This study aimed to assess the serial angiographic changes of de novo lesions post-DCB therapy and further explore the cut-off values of lesion and vessel QFR, which predict vessel restenosis (diameter stenosis [DS] ≥50%) at mid-term follow-up.
METHODS:
The data of patients who underwent DCB therapy between January 2014 and December 2019 from the multicenter hospital were retrospectively collected for QFR analysis. From their QFR performances, which were analyzed by CAG images at follow-up, we divided them into two groups: group A, showing target vessel DS ≥50%, and group B, showing target vessel DS <50%. The median follow-up time was 287 days in group A and 227 days in group B. We compared the clinical characteristics, parameters during DCB therapy, and QFR performances, which were analyzed by CAG images between the two groups, in need to explore the cut-off value of lesion/vessel QFR which can predict vessel restenosis. Student's t test was used for the comparison of normally distributed continuous data, Mann-Whitney U test for the comparison of non-normally distributed continuous data, and receiver operating characteristic (ROC) curves for the evaluation of QFR performance which can predict vessel restenosis (DS ≥50%) at mid-term follow-up using the area under the curve (AUC).
RESULTS:
A total of 112 patients with 112 target vessels were enrolled in this study. Group A had 41 patients, while group B had 71. Vessel QFR and lesion QFR were lower in group A than in group B post-DCB therapy, and the cut-off values of lesion QFR and vessel QFR in the ROC analysis to predict target vessel DS ≥50% post-DCB therapy were 0.905 (AUC, 0.741 [95% confidence interval, CI: 0.645, 0.837]; sensitivity, 0.817; specificity, 0.561; P < 0.001) and 0.890 (AUC, 0.796 [95% CI: 0.709, 0.882]; sensitivity, 0.746; specificity, 0.780; P < 0.001).
CONCLUSIONS
The cut-off values of lesion QFR and vessel QFR can assist in predicting the angiographic changes post-DCB therapy. When lesion/vessel QFR values are <0.905/0.890 post-DCB therapy, a higher risk of vessel restenosis is potentially predicted at follow-up.
Constriction, Pathologic
;
Coronary Angiography
;
Coronary Artery Disease/therapy*
;
Coronary Restenosis
;
Follow-Up Studies
;
Fractional Flow Reserve, Myocardial
;
Humans
;
Pharmaceutical Preparations
;
Predictive Value of Tests
;
Retrospective Studies
;
Treatment Outcome
4.Advances in Preparation and Evaluation of Non-vascular Drug-eluting Stents.
Yu GAN ; Cong WEN ; Fang JIN ; Hua ZHU
Chinese Journal of Medical Instrumentation 2021;45(1):46-51
In recent years, the application of stent intervention in the treatment of non-vascular stenosis caused by benign and malignant factors has been widely concerned by researchers at home and abroad. The high incidence of malignant tumor diseases, further promotes the development of stent intervention. The conventional bare stents are prone to irritate luminal mucosa and produce restenosis and other complications. The emergence of drug-eluting stent is expected to solve this problem and become one of the important development trends of non-vascular stents. In this paper, the drug loading materials, drug loading layer drugs, preparation technology and quality evaluation methods of non-vascular drugeluting stent are described based on the recent research and clinical application documents, so as to provide basis and direction for the follow-up research and development.
Coronary Restenosis
;
Drug-Eluting Stents
;
Humans
;
Prosthesis Design
;
Treatment Outcome
5.Efficacy of drug coated balloon versus conventional balloon in the treatment of coronary de novo bifurcation lesions: a meta-analysis.
En Rui XIE ; Chang LIU ; Ya Juan NI ; Deng Feng GAO ; Jie DENG
Chinese Journal of Cardiology 2021;49(12):1227-1234
Objective: To systematically evaluate the efficacy of drug coated balloon (DCB) versus conventional balloon in the treatment of coronary de novo bifurcation lesions. Methods: The databases of PubMed, Embase, Cochrane Library, Web of science, CNKI (China National Knowledge Infrastructure), Wanfang database, VIP, China Biology Medicine disc, Chinese clinical trial registry, American clinical trial registry and cardiovascular related websites until September 2020 were retrieved for collecting the randomized controlled trials (RCT) comparing DCB versus conventional balloon in the treatment of coronary de novo bifurcation lesions. The risk of bias of included studies was assessed using the Cochrane risk assessment tool. The meta-analysis was performed by using Revman 5.3 and Stata 14.0 software. Results: Seven RCTs with a total of 613 patients were included in this meta-analysis. Among the included studies, 4 articles reached the low risk of bias, and the other 3 articles reached the medium risk of bias. The results of meta-analysis showed that there was no significant difference in the major adverse cardiac events (RR=0.65, 95%CI 0.39-1.08, P=0.10), myocardial infarction (RR=0.68, 95%CI 0.25-1.80, P=0.43), target lesion revascularization (RR=0.94, 95%CI 0.53-1.67, P=0.83) between DCB group and conventional balloon group. Late lumen loss of side branch was less in the DCB group than that in the conventional balloon group (WMD=-0.25, 95%CI -0.41--0.09, P<0.01) and the risk of side branch restenosis was also lower in the DCB group than that in the conventional balloon group (RR=0.47, 95%CI 0.22-0.98, P<0.05). However, subgroup analysis showed that the conclusions of domestic studies and foreign studies on late lumen loss and side branch restenosis were inconsistent. The meta-analysis based on domestic literature showed that the risk of side branch restenosis after DCB treatment was lower compared with conventional balloon group (RR=0.29, 95%CI 0.15-0.57, P<0.05), while this parameter derived from foreign literatures remained unchanged between two groups (P=0.53). The meta-analysis results of domestic literature showed that late lumen loss in DCB group was less than that in conventional balloon group (WMD=-0.32, 95%CI -0.51--0.13, P<0.05), but this phenomenon was not observed in foreign literatures (P=0.30). Conclusions: The use of DCB in the treatment of coronary de novo bifurcation lesions has the potential to reduce the rate of restenosis and late lumen loss of side branch compared with conventional balloon group. However, due to the limitation on quantity, quality and results of published studies, more high-quality and large scale RCTs are still needed to confirm these findings.
Angioplasty, Balloon, Coronary
;
Coronary Artery Disease
;
Coronary Restenosis
;
Humans
;
Myocardial Infarction
;
Pharmaceutical Preparations
;
Treatment Outcome
6.Application of Rotarex mechanical thrombectomy system in treating in-stent restenosis of lower extremity arteriosclerosis obliterans.
Jin Man ZHUANG ; Tian Run LI ; Xuan LI ; Jing Yuan LUAN ; Chang Ming WANG ; Qi Chen FENG ; Jin Tao HAN
Journal of Peking University(Health Sciences) 2021;53(4):740-743
OBJECTIVE:
To evaluate the role of Rotarex mechanical thrombectomy system in treating instent restenosis of peripheral artery disease (PAD).
METHODS:
The clinical data of 7 in-stent restenosis (ISR) cases of lower extremity PAD from June 2017 to Dec 2018 were retrospectively analyzed. There were 5 males and 2 females and the mean age was (70.0±7.6) years from 59.0 to 76.0 years. All the cases were treated by Rotarex mechanical thrombectomy system. In the 7 cases, time interval from the previous stent implantation to ischemia recurrence was 1.0 to 72.0 months, and the median time was 6.0 months. The period from ischemia recurrence to endovascular therapy was 3 days to 2 years, and the median time was 62 days. Rotarex mechanical debulking catheter and percutaneous transluminal angioplasty (PTA) were used in all the cases, and the stent was used only when it was necessary. Anticoagulation was used for 24 hours after procedures and then antiplatelet agents were used as usual. Doppler ultrasonography was taken during the followed-up.
RESULTS:
All the 7 cases were successful in technology, 3 of which were implanted with new stents for the fracture of the old ones. while for the other four cases, no new stent was implanted. The ankle-brachial index (ABI) increased from 0.31±0.08 to 0.86±0.08 after treatment (t=-12.84, P < 0.001). Thrombectomy was applied urgently in one case because of acute thrombosis in the stent, and the result was good. There was no other complications in hospital. All the patients were followed up for 5.0-22.0 months, and the median time was 14.0 months. No death and amputation occurred during the follow-up. One patient stopped antiplatelet agents because of gastrointestinal bleeding, which resulted in acute thrombosis. in-stent restenosis reappeared in 3 cases.
CONCLUSION
Debulking using Rotarex catheter is safe and effective in treating in-stent restenosis of PAD, especially in reducing stents implantation, but is not good at dealing with old thrombus and proliferating intima, and can do nothing about fractured stents and hyperplasia of intima, so it needs to be combined with stents and drug coated balloons.
Aged
;
Arteriosclerosis Obliterans/surgery*
;
Coronary Restenosis
;
Female
;
Femoral Artery
;
Humans
;
Lower Extremity
;
Male
;
Middle Aged
;
Recurrence
;
Retrospective Studies
;
Stents
;
Thrombectomy
;
Treatment Outcome
7.Clinical characteristics of early and late drug-eluting stent in-stent restenosis and mid-term prognosis after repeated percutaneous coronary intervention.
Jian-Feng ZHENG ; Ting-Ting GUO ; Yuan TIAN ; Yong WANG ; Xiao-Ying HU ; Yue CHANG ; Hong QIU ; Ke-Fei DOU ; Yi-Da TANG ; Jin-Qing YUAN ; Yong-Jian WU ; Hong-Bing YAN ; Shu-Bin QIAO ; Bo XU ; Yue-Jin YANG ; Run-Lin GAO
Chinese Medical Journal 2020;133(22):2674-2681
BACKGROUND:
The mechanism and characteristics of early and late drug-eluting stent in-stent restenosis (DES-ISR) have not been fully clarified. Whether there are different outcomes among those patients being irrespective of their repeated treatments remain a knowledge gap.
METHODS:
A total of 250 patients who underwent initial stent implantation in our hospital, and then were readmitted to receive treatment for the reason of recurrent significant DES-ISR in 2016 were involved. The patients were categorized as early ISR (<12 months; E-ISR; n = 32) and late ISR (≥12 months; L-ISR; n = 218). Associations between patient characteristics and clinical performance, as well as clinical outcomes after a repeated percutaneous coronary intervention (PCI) were evaluated. Primary composite endpoint of major adverse cardiac events (MACEs) included cardiac death, non-fatal myocardial infarction (MI), or target lesion revascularization (TLR).
RESULTS:
Most baseline characteristics are similar in both groups, except for the period of ISR, initial pre-procedure thrombolysis in myocardial infarction, and some serum biochemical indicators. The incidence of MACE (37.5% vs. 5.5%; P < 0.001) and TLR (37.5% vs. 5.0%; P < 0.001) is higher in the E-ISR group. After multivariate analysis, E-ISR (odds ratio [OR], 13.267; [95% CI 4.984-35.311]; P < 0.001) and left ventricular systolic dysfunction (odds ratio [OR], 6.317; [95% CI 1.145-34.843]; P = 0.034) are the independent predictors for MACE among DES-ISR patients in the mid-term follow-up of 12 months.
CONCLUSIONS
Early ISR and left ventricular systolic dysfunction are associated with MACE during the mid-term follow-up period for DES-ISR patients. The results may benefit the risk stratification and secondary prevention for DES-ISR patients in clinical practice.
Coronary Angiography
;
Coronary Restenosis
;
Drug-Eluting Stents/adverse effects*
;
Humans
;
Percutaneous Coronary Intervention/adverse effects*
;
Prognosis
;
Treatment Outcome
8.Association of CMTM5 gene expression with the risk of in-stent restenosis in patients with coronary artery disease after drug-eluting stent implantation and the effects and mechanisms of CMTM5 on human vascular endothelial cells.
Teng Fei LIU ; Tao LIN ; Li Hui REN ; Guang Ping LI ; Jian Jun PENG
Journal of Peking University(Health Sciences) 2020;52(5):856-862
OBJECTIVE:
To elucidate the correlation between CKLF-like marvel transmembrane domain containing member (CMTM5) gene and the risk of in-stent restenosis (ISR) with coronary artery disease (CAD) patients and to detect the effects and mechanisms of CMTM5-stimulated genes on human vascular endothelial cells (ECs) proliferation and migration.
METHODS:
A total of 124 hospitalized patients in Shijitan Hospital were enrolled in this study. All the CAD patients were detected with platelet reactivity and grouped into two groups according to platelet reactivity; ISR was conformed by coronary angiography; RT-PCR method was used to detect CMTM5 gene expression; The CMTM5 over expression, reduction and control EC lines were established; Cell count, MTT, Brdu and flow cytometry methods were used to detect the proliferation of ECs, scratch and transwell experiments to test the migration of ECs, Western blot was used to detect signal path expressions.
RESULTS:
CMTM5 gene expression in HAPR (High on aspirin platelet reactivity) group was 1.72 times compared with No-HAPR group, which was significantly higher than No-HAPR group. HAPR group ISR rate was 25.8% (8 cases), the incidence of No-HAPR ISR group was 9.7% (9 cases), and the results showed that in HAPR group, the incidence of ISR was significantly higher than that in No-HAPR group (P=0.04, OR=0.04, 95%CI=1.16-7.52), which showed that CMTM5 gene was significantly correlated with the risk of ISR. In HAPR group ISR rate was 25.8% (8 cases), the incidence of ISR in No-HAPR group was 9.7% (9 cases), and the results showed that the risk of ISR in HAPR group was significantly higher than that in No-HAPR group. All the results showed that CMTM5 was significantly correlated with the risk of ISR in CAD patients (P < 0.05). CMTM5 overexpression inhibited the proliferation and migration ability of ECs (P < 0.05), PI3K/Akt signaling pathways were involved in the role of regulation on ECs.
CONCLUSION
Our results revealed that CMTM5 gene was closely related with ISR, CMTM5 overexpression may repress ECs proliferation and migration through regulating PI3K-Akt signaling.
Chemokines
;
Coronary Artery Disease/surgery*
;
Coronary Restenosis
;
Drug-Eluting Stents/adverse effects*
;
Endothelial Cells
;
Humans
;
MARVEL Domain-Containing Proteins
;
Phosphatidylinositol 3-Kinases
;
Tumor Suppressor Proteins
9.Impact factors of in-stent restenosis following successful stent implantation for acquired severe pulmonary vein stenosis post atrial fibrillation ablation.
Yan Jie LI ; Xin PAN ; Cheng WANG ; Lan MA ; Ben HE
Chinese Journal of Cardiology 2020;48(5):373-377
Objective: To investigate the influencing factors of in-stent restenosis (ISR) following successful stent implantation in patients with ablation-associated severe pulmonary vein stenosis (PVS) who undergo atrial fibrillation ablation. Methods: Data of patients who underwent pulmonary vein angiography to confirm PVS after radiofrequency ablation for atrial fibrillation (AF) and received pulmonary vein stenting at Shanghai Chest Hospital from March 2010 to December 2017 were retrospectively analysed. All patients were followed up for a long period of time (pulmonary vein contract-enhanced CT within 6 to 12 months after operation was performed, and pulmonary angiography was performed if CT indicated stenosis>50%). The incidence of ISR was recorded. According to angiography, the patients were divided into ISR group and non-ISR group. The clinical and intraoperative imaging characteristics and interventional data were compared between the two groups. Logistic regression was used to analyse the influencing factors of ISR. Results: A total of 47 patients ((47.1±12.2) years old) were enrolled in this study, including 28 males(59.6%). There were 19 cases in ISR group and 28 cases in non-ISR group. Compared with the non-ISR group, the ISR group received more pulmonary vein isolation ((2.8±0.9) vs. (1.8±1.3), P=0.02), and the interval between last ablation and stenting was longer ((19.4±9.6) vs. (13.0±12.4), P=0.03). The incidence of ISR in patients with stent diameter≤8 mm was significantly higher than those with stent diameter>8 mm (33.3%(20/60) vs. 8.1%(3/37), P<0.01). Logistic regression analysis found that the number of radiofrequency ablation>1 (OR=2.1, 95%CI 1.3-3.9, P=0.02), and the time from the last ablation to stent placement>12 months (OR=1.5, 95%CI 1.1-2.5, P=0.03), reference diameter of stenosed distal vessel (OR=0.7, 95%CI 0.5-0.9, P=0.04), post procedural minimal luminal diameter (OR=0.4, 95%CI 0.2-0.8, P=0.02) and stent diameter (OR=0.6, 95%CI 0.3-0.9, P=0.03) were independent factors of ISR. Conclusions: The greater number of radiofrequency ablations and the longer time from the last ablation to stent placement increase the risk of ISR. The larger reference diameter of the stenosed distal vessel, stent diameter and post procedural minimal luminal diameter are the protective factors of ISR.
Adult
;
Atrial Fibrillation
;
Catheter Ablation
;
China
;
Constriction, Pathologic
;
Coronary Restenosis
;
Female
;
Humans
;
Male
;
Middle Aged
;
Pulmonary Veins
;
Retrospective Studies
;
Stenosis, Pulmonary Vein
;
Stents
;
Treatment Outcome
10.In-stent restenosis assessed with frequency domain optical coherence tomography shows smooth coronary arterial healing process in second-generation drug-eluting stents.
Takashi KAJIYA ; Hiroshi YAMAGUCHI ; Junichiro TAKAOKA ; Kengo FUKUNAGA ; Ryoichi ARIMA ; Akihiro MIYAMURA ; Toshiko NINOMIYA ; Nobuhiko ATSUCHI ; Yoshihiko ATSUCHI ; Mitsuyasu TERASHIMA ; Hideaki KANEDA ; Mitsuru OHISHI
Singapore medical journal 2019;60(1):48-51
INTRODUCTION:
The pathophysiology and mechanism of in-stent restenosis (ISR) after implantation of second-generation drug-eluting stents (DESs) are not fully clear. We compared the morphological characteristics of ISR between first- and second-generation DESs using frequency domain optical coherence tomography (OCT).
METHODS:
Patients who underwent follow-up coronary angiography (CAG) after first-generation (CYPHER™ and TAXUS™) and second-generation (Nobori®, PROMUS Element™, Resolute Integrity and XIENCE) DES implantations were examined. ISR was defined as lesions of over 50% diameter stenosis at follow-up CAG. Frequency domain OCT was performed at the time of revascularisation of ISR. Tissue morphology was assessed at minimum lumen area. OCT images of DESs at both early (≤ 1 year) and late (> 1 year) phase follow-up were compared.
RESULTS:
On qualitative OCT assessment, the ratios of homogeneous, layered, heterogeneous without-attenuation and heterogeneous with-attenuation morphologies were 57.1%, 17.1%, 20.0% and 5.7%, respectively, for second-generation DES ISR (n = 35), and 16.7%, 25.0%, 25.0% and 33.3%, respectively, for first-generation DES ISR (n = 36). At late phase follow-up, homogeneous morphology was significantly more common for second-generation DES ISR compared to first-generation DES ISR (first-generation: 8.0% vs. second-generation: 50.0%; p < 0.01) while heterogeneous with-attenuation morphology was significantly more common for first-generation DES ISR (first-generation: 44.0% vs. second-generation: 5.6%; p < 0.01).
CONCLUSION
Homogeneous tissue morphology was more frequently found for second-generation than first-generation DES ISR, especially in the late phase. This suggested that neointimal hyperplasia was the main mechanism in second-generation DES ISR, and that the neointima was stabilised, much like in bare metal stent implantation.
Aged
;
Constriction, Pathologic
;
pathology
;
Coronary Angiography
;
Coronary Restenosis
;
diagnostic imaging
;
pathology
;
Coronary Vessels
;
diagnostic imaging
;
pathology
;
surgery
;
Drug-Eluting Stents
;
adverse effects
;
Female
;
Humans
;
Incidence
;
Male
;
Metals
;
Middle Aged
;
Neointima
;
Retrospective Studies
;
Tomography, Optical Coherence

Result Analysis
Print
Save
E-mail