1.Corneal Collagen Cross-linking for Corneal Ulcer from Moraxella Group
Journal of the Korean Ophthalmological Society 2020;61(2):200-204
PURPOSE: To report a case of corneal collagen cross-linking for corneal ulcer caused by the Moraxella group.CASE SUMMARY: A 77-year-old male had decreased visual acuity for several days in his right eye. The patient showed severe stromal ring infiltrates with a corneal epithelial defect measuring (5.0 × 7.0 mm), a corneal endothelial plaque, and a hypopyon measuring less than 1.0 mm in height in the anterior chamber of the right eye. There was no abnormal finding in the right eye using B-scan ultrasonography. Before starting treatment, a corneal culture was conducted. The culture tests showed the presence of the Moraxella group. Because the patient was diagnosed with a corneal ulcer caused by the Moraxella group, corneal collagen cross-linking (CXL) was performed. The antimicrobial susceptibility test confirmed that this Moraxella group was sensitive to ceftazidime, so the patient was treated with 5% ceftazidime eye drops and 0.5% moxifloxacin eye drops every 2 hours for 9 months after corneal collagen CXL. The uncorrected visual acuity was 0.1 in the right eye, and there was almost no corneal stromal melting on anterior segment optical coherence tomography.CONCLUSIONS: This is the first known case of a corneal ulcer, in the Republic of Korea, caused by the Moraxella group and treated with corneal collagen CXL. Corneal collagen CXL should be considered as a surgical treatment for patients who have an impending corneal perforation due to a corneal ulcer because it is a simple procedure and causes fewer serious complications than other treatments.
Aged
;
Anterior Chamber
;
Ceftazidime
;
Collagen
;
Cornea
;
Corneal Perforation
;
Corneal Ulcer
;
Freezing
;
Humans
;
Male
;
Moraxella
;
Ophthalmic Solutions
;
Republic of Korea
;
Tomography, Optical Coherence
;
Ultrasonography
;
Visual Acuity
2.A Report of Two Case of Ocular Toxicity Resulting from Direct or Indirect Bee Venom
Chan Ho LEE ; Chang Hwan LEE ; Moo Hwan CHANG ; Young Seung SEO
Journal of the Korean Ophthalmological Society 2019;60(4):399-405
PURPOSE: To report a patient stung by a bee, who was diagnosed with sterile endopthalmitis and another patient diagnosed with optic neuritis, with decreasing visual acuity, after refined bee venom injection around the orbital tissue. CASE SUMMARY: A 82-year-old female visited our hospital for decreased visual acuity in the right eye and ocular pain due to a bee sting. The bee sting penetrated the sclera into the vitreous. In the anterior segment, severe cornea edema and anterior chamber cells were seen. Using ultrasonography, inflammation was seen around the intravitreal area. After 3 months, intravitreal inflammation regressed but the patient's visual acuity was light perception negative, and corneal opacity, neovascularization, and phthisis bulbi were detected. A 55-year-old male visited our hospital for ocular pain in the right eye and decreasing visual acuity after refined bee venom injection around the orbital tissue. The best-corrected visual acuity in the right eye was 15/100, there was moderate injection on the conjunctiva. A relative afferent pupillary defect, abnormal color vision test results, and a defect in the visual field test were observed. There was no pain during external ocular movement, and other general blood tests, and a brain MRI were normal. Based on these symptoms, methylprednisolone megatherapy was started for treatment of optic neuritis. After treatment, visual acuity of the right eye was 9/10 and all other clinical optic neuritis symptoms regressed. CONCLUSIONS: Based on these two cases, ocular toxicity from bee venom could result from both direct and indirect courses. Treatment using refined bee venom might be harmful, and caution is recommended in its use.
Aged, 80 and over
;
Anterior Chamber
;
Bee Venoms
;
Bees
;
Bites and Stings
;
Brain
;
Color Vision
;
Conjunctiva
;
Cornea
;
Corneal Opacity
;
Edema
;
Female
;
Hematologic Tests
;
Humans
;
Inflammation
;
Magnetic Resonance Imaging
;
Male
;
Methylprednisolone
;
Middle Aged
;
Optic Neuritis
;
Orbit
;
Pupil Disorders
;
Sclera
;
Ultrasonography
;
Visual Acuity
;
Visual Field Tests
3.Electromagnetic tracking-based ultrasound/computed tomography fusion imaging in dogs: preliminary application to ocular and periocular regions
Jihye CHOI ; Sang Kwon LEE ; Seungjo PARK
Journal of Veterinary Science 2019;20(5):e51-
In ultrasound/computed tomography (CT) fusion images, ultrasound allows visualization of the target in real time. CT provides a navigation for ultrasound scanning and improves the overview in areas of limited visualization with ultrasound. This study was performed to investigate the feasibility of ultrasound/CT fusion based on an electromagnetic tracking technique using external fiducial markers for canine ocular and periocular regions. In 7 Beagle dogs, contrast-enhanced CT images of the head were obtained with placing external fiducial markers over the frontal region and both sides of the forepaws of the dog. Ultrasonography was performed under a magnetic field by installing a position sensor in the linear probe, without changing the dog's position. The positions of the external fiducial markers were adjusted and matched, based on the CT images. The execution time of co-registration and the distance between the regions of interest and the co-registration points, the frontal bone, cornea, retina, and optic nerve, were estimated. Approximately 60% of external fiducial markers were properly recognized in all dogs. After adjustment, all external fiducial markers were precisely matched. The co-registration execution time was less than 1 min. The distances between the regions of interest and co-registration points were less than 3 mm in all dogs. The electromagnetic tracking technique using external fiducial markers was a simple and applicable method for fusion imaging of a canine head using real-time ultrasonography and CT. This technique can be useful for interventional procedures of retrobulbar and periorbital lesions.
Animals
;
Cornea
;
Dogs
;
Fiducial Markers
;
Frontal Bone
;
Head
;
Magnetic Fields
;
Magnets
;
Methods
;
Optic Nerve
;
Retina
;
Tomography, X-Ray Computed
;
Ultrasonography
4.Comparison of Central Corneal Thickness Measurements between Noncontact Specular Microscopy and Ultrasound Pachymetry
Kyoung OHN ; Mee Yon LEE ; Young Chun LEE ; Hye Young SHIN
Journal of the Korean Ophthalmological Society 2019;60(7):635-642
PURPOSE: We compared and analyzed central corneal thickness (CCT) measurements according to the corneal thickness obtained with noncontact specular microscopy (NCSM) and ultrasound pachymetry (USP). METHODS: CCT was measured in the order of NCSM and USP by a single optometrist in 120 eyes of 120 healthy subjects. The measurements were compared between the devices and the measurement agreements and correlations between the devices were analyzed. To determine if the measurements differed depending on the thickness of the cornea, the patients were divided into three tertile groups from the thinnest patient by CCT measurement using USP, and then the differences in CCT measured by the two devices were analyzed. RESULTS: The CCT measurements using NCSM and USP were 548.25 ± 4.64 µm and 533.09 ± 35.96 µm, respectively. NCSM measurements were found to be thicker, showing statistically significant differences between the measurements (p < 0.001). The two examinations showed a high degree of correlation (r = 0.878; p < 0.01). In the three groups, the differences in CCT measurements between NCSM and USP were 12.93 ± 21.88 µm, 16.85 ± 15.89 µm, and 15.70 ± 20.46 µm, respectively, but the differences between the three groups were not statistically significant (p = 0.655). CONCLUSIONS: Our results show that although the differences in CCT measurements using NCSM and USP were consistent regardless of the corneal thickness, the CCT measurements by NCSM and USP were highly correlated.
Cornea
;
Corneal Pachymetry
;
Healthy Volunteers
;
Humans
;
Microscopy
;
Ultrasonography
5.Comparison of Central Corneal Thickness Measured by Swept-source Optical Coherence Tomography and Ultrasound Pachymetry.
Woo Beom SHIN ; Hyun Kyo JEONG ; Min Kyo KIM ; Hong Seok KIM ; Jun Mo LEE ; Chan Yun KIM ; Ji Hyun KIM
Journal of the Korean Ophthalmological Society 2017;58(3):276-282
PURPOSE: To analyze and compare ultrasound pachymetry (USP) with a more recently adopted device, the intra ocular lens (IOL) master 700, which are both used to measure central corneal thickness. METHODS: The central corneal thickness was measured in 24 eyes of 12 glaucoma patients and in 83 eyes of 42 normal patients. First, the IOL master 700 was used to measure the central corneal thickness, followed by measurements taken using USP later. The results were analyzed using a paired t-test. We analyzed the agreement and the correlations between the two test devices by using Bland-Altman plots and the Pearson correlation test. To evaluate the reproducibility, measurements with the IOL master 700 were taken twice for a few normal patients within a small time interval. RESULTS: Via the IOL master 700, the thickness of the central cornea showed a high reproducibility and repeatability, demonstrating 2.7 ± 1.7 µm for the test-retest variability, 6.78% for the coefficient of variation, and 0.997 for the intraclass correlation value. The mean measurements using USP and the IOL master 700 are 554.4 ± 37.4 µm and 551.1 ± 37.1 µm, respectively, showing that the IOL master 700 measured significantly smaller values than USP with a p-value < 0.001. The deviations between the two methods are scattered throughout the 95% confidence interval. According to the Pearson correlation test, the measured values of the two test devices were found to have a highly positive correlation (r = 0.977, p < 0.0001). CONCLUSIONS: This study demonstrated that the central corneal thickness (CCT) measured via the IOL master was significantly thinner than that of USP, and the two test devices had a high correlation and good agreement. The CCT value measured via the IOL master 700 also exhibited high reproducibility.
Cornea
;
Glaucoma
;
Humans
;
Tomography, Optical Coherence*
;
Ultrasonography*
6.Ocular Findings in Mucolipidosis Type II.
Su Youn SUH ; Chong Kun CHEON ; Jae Ho JUNG
Journal of the Korean Ophthalmological Society 2017;58(5):616-619
PURPOSE: To report ocular findings of a mucolipidosis type II patient with novel mutation. CASE SUMMARY: A 10-year-old boy visited our pediatric genetic metabolic clinic for evaluation of his overall developmental delay and short stature. The boy was diagnosed with mucolipidosis type II (I-cell disease) using plasma enzyme assay and DNA sequencing of the GNPTAB gene mutation. An ophthalmologic investigation was then performed, and a depressed nasal bridge, broad nose, and swelling in the upper lid of both eyes were noted. The best corrected visual acuity was 0.32 and 0.1 and the intraocular pressure was 35 mmHg and 24 mmHg in the right and left eyes, respectively. The anterior chamber angles of both eyes were normal and mild cornea opacity in both eyes was observed. Fundus examination revealed retinal atrophy with folds in both eyes, as well as optic disc edema and optic atrophy in the right and left eyes, respectively. Atherosclerotic changes in the retinal vessels and cystoid macular edema in the left eye were observed, and ocular ultrasound revealed increased posterior sclera thickness in both eyes. CONCLUSIONS: Ocular manifestations of mucolipidosis type II are not currently well-known, and differentiation from other metabolic disorders may be difficult. An ophthalmic work-up can assist in diagnosis, and regular ophthalmic examinations should be used to maintain visual function in mucolipidosis patients.
Anterior Chamber
;
Atrophy
;
Child
;
Cornea
;
Diagnosis
;
Edema
;
Enzyme Assays
;
Humans
;
Intraocular Pressure
;
Lysosomal Storage Diseases
;
Macular Edema
;
Male
;
Mucolipidoses*
;
Nose
;
Optic Atrophy
;
Plasma
;
Retinal Vessels
;
Retinaldehyde
;
Sclera
;
Sequence Analysis, DNA
;
Ultrasonography
;
Visual Acuity
7.Intraocular Lens Power Calculations Using Dual Scheimpflug Analyzer.
Young Bok LEE ; Ka Young YI ; So Hyun BAE ; Ha Kyoung KIM ; Joon Young HYON ; Won Ryang WEE ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2016;57(3):369-379
PURPOSE: To investigate the accuracy of intraocular lens power calculations using simulated keratometry (simK) of dual Scheimpflug analyzer and 5 types of formulas in cataract patients. METHODS: The keratometry (K), axial length (AXL) and anterior chamber depth (ACD) were measured using ultrasound biometry (USB) combined with auto-keratometry (Auto-K), parital coherence interferometry (PCI; IOL master®) and dual Scheimpflug analyzer (DSA; Galilei®) in 39 eyes of 39 patients. Predicted refraction was calculated using Auto-K, mean K of PCI, and simK and total corneal power (TCP) of DSA in the Sanders-Retzlaff-Kraff (SRK-T) formula. The SRK-II, SRK-T, Holladay II, Haigis, and Hoffer-Q formula were used to calculate predicted refraction with the simK of DSA and AXL of USB. Manifest refraction, mean numerical error (MNE) and mean absolute error were evaluated 1, 3 and 6 months after cataract surgery. RESULTS: TCP of DSA was lower compared with other keratometric values (p < 0.05). The MNE was not different among Auto-K, mean K and simK. The MNE using TCP was larger compared with Auto-K, mean K and simK at 1 month after surgery (p < 0.05). There was a difference in MNE between simK and TCP of DSA at 6 months after surgery (p < 0.05). The MNE of SRK-T formula was the smallest in the intraocular lens (IOL) power calculation using the simK of DSA. CONCLUSIONS: We suggest using IOL power calculations with simK of DSA and SRK-T formula rather than TCP of DSA in cataract patients with normal corneas.
Anterior Chamber
;
Biometry
;
Cataract
;
Cornea
;
Humans
;
Interferometry
;
Lenses, Intraocular*
;
Ultrasonography
8.Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Relation to Central Corneal Thickness.
Min Kyo KIM ; Si Yoon PARK ; Chan Yun KIM ; Ji Hyun KIM
Journal of the Korean Ophthalmological Society 2015;56(9):1392-1399
PURPOSE: In this study we compared the intraocular pressures (IOPs) measured using dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) and investigated the correlation between central corneal thickness (CCT) and IOP. METHODS: In a prospective study, 178 eyes of 91 subjects with glaucoma and glaucoma suspect were enrolled. IOP was measured using DCT and GAT and CCT was measured using ultrasound pachymetry. Each eye was classified into 1 of 3 groups according to their CCT: low CCT (Group A; CCT < 525 microm), normal CCT (Group B; 525 < or = CCT < 561 microm), and high CCT (Group C; CCT > or = 561 microm). In each group, we investigated the correlation between CCT and IOP measurement using GAT and DCT. RESULTS: A significant correlation was found between CCT and IOP measured using GAT (p < 0.001), but not between CCT and IOP measured using DCT (p = 0.108) in all patients. Subgroup analysis showed that CCT affected IOP measured with GAT only in Group A (p = 0.027) and IOP measured with DCT was not affected by CCT in all 3 groups. CONCLUSIONS: IOP measured using GAT and DCT were significantly affected by CCT, especially when the CCT was low. CCT may have no effect on DCT thus, IOP measured using DCT is more reliable than GAT in patients with thin corneas.
Cornea
;
Glaucoma
;
Humans
;
Intraocular Pressure
;
Manometry*
;
Prospective Studies
;
Ultrasonography
9.Changes in Central Corneal Thickness and Corneal Endothelial Morphology in Contact Lens-Wearing Diabetic Patients.
Journal of the Korean Ophthalmological Society 2014;55(10):1426-1431
PURPOSE: To evaluate the changes in central corneal thickness and corneal endothelium in contact lens-wearing diabetic patients. METHODS: This study included 113 patients who visited the Department of Ophthalmology, Konkuk University Medical Center from August 2006 to August 2007. Ultrasound pachymetry and noncontact specular microscopy were performed on the right eyes of 26 diabetic patients who regularly wore soft contact lenses (group 1), 27 diabetic patients who did not wear soft contact lenses (group 2), 30 soft contact lens-wearers without diabetes mellitus (DM) (group 3), and 30 normal subjects who did not wear soft contact lenses (group 4). Central corneal thickness, corneal endothelial cell density, endothelial cell coefficient of variation, and percentage of hexagonal endothelial cells were compared between the groups. RESULTS: Average duration of diabetes in groups 1 and 2 was 4.38 and 4.41 years, respectively, and average duration of soft contact lens wear in groups 1 and 3 was 5.27 and 3.65 years, respectively. The central cornea was significantly thicker and the endothelial cell density was significantly lower in group 1 than in groups 3 and 4. The cell size coefficient of variation was higher in group 1 than in groups 2 and 4 and higher in group 3 than in group 4. The percentage of hexagonal cells was significantly lower in group 3 than in group 4. CONCLUSIONS: Central corneal thickness and endothelial cell density are more affected by DM than contact lens use, and corneal endothelial cell morphology is influenced more by contact lens use than DM. Contact lens use in diabetic patients significantly influences all characteristics of the corneal endothelium compared with those in normal subjects. Patients with DM should be advised not to wear contact lenses.
Academic Medical Centers
;
Cell Size
;
Contact Lenses
;
Contact Lenses, Hydrophilic
;
Cornea
;
Diabetes Mellitus
;
Endothelial Cells
;
Endothelium, Corneal
;
Humans
;
Microscopy
;
Ophthalmology
;
Ultrasonography
10.Reliability of RTVue, Visante, and Slit-Lamp Adapted Ultrasonic Pachymetry for Central Corneal Thickness Measurement.
Jin Pyo HONG ; Sang Min NAM ; Tae Im KIM ; Kyoung Yul SEO ; Sang Yeop LEE ; Alessandro MEDURI ; Eung Kweon KIM
Yonsei Medical Journal 2012;53(3):634-641
PURPOSE: To evaluate reliability of Fourier-domain optical coherence tomography (OCT) (RTVue), time-domain OCT (Visante), and slit-lamp adapted ultrasonic pachymetry (SL-US) in the measurement of central corneal thickness (CCT). MATERIALS AND METHODS: Thirty healthy volunteers visited our clinic 3 times and fifty eyes were measured by one physician. RTVue and Visante were randomly performed, and then SL-US, in which the ultrasound probe was inserted into the Goldmann tonometry mount, was done. During the second visit, each measurement was repeated 3 times. Measurements on the second visit were averaged, and agreement among the instruments was investigated with Bland-Altman plots. RESULTS: RTVue showed smaller repeatability coefficient than Visante and SL-US (4.7, 8.3, and 7.7 microm, respectively). Intersession reproducibility of RTVue and Visante was worse than their repeatability. CCT of RTVue was estimated to be maximally different by 11.8 microm from CCT of Visante and 8.8 microm from CCT of SL-US. The repeatability coefficient of SL-US was 7.7 microm and its reproducibility was similar to the repeatability. CONCLUSION: CCT measured by RTVue showed good reliability and generally agreed with Visante and SL-US. SL-US was as reliable as triple touching conventional US even with a single touch on the cornea.
Adult
;
Cornea/*anatomy & histology/pathology/ultrasonography
;
Corneal Topography
;
Female
;
Humans
;
Male
;
Reproducibility of Results
;
Tomography, Optical Coherence/*methods

Result Analysis
Print
Save
E-mail