1.Contrast-enhanced ultrasound and contrast-enhanced computed tomography for differentiating mass-forming pancreatitis from pancreatic ductal adenocarcinoma: a meta-analysis.
Jie YANG ; Jiayan HUANG ; Yonggang ZHANG ; Keyu ZENG ; Min LIAO ; Zhenpeng JIANG ; Wuyongga BAO ; Qiang LU
Chinese Medical Journal 2023;136(17):2028-2036
BACKGROUND:
Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC.
METHODS:
A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance.
RESULTS:
Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2 = 0.00%) and 95% (95% CI, 90%-97%; I2 = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2 = 66.37%) and 94% (95% CI, 90-96%; I2 = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P > 0.05).
CONCLUSIONS
CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.
Humans
;
Contrast Media
;
Bayes Theorem
;
Tomography, X-Ray Computed/methods*
;
Pancreatic Neoplasms/diagnostic imaging*
;
Carcinoma, Pancreatic Ductal/diagnostic imaging*
;
Sensitivity and Specificity
;
Pancreatitis/diagnostic imaging*
;
Ultrasonography/methods*
2.Long-term effect of a large dose of iodinated contrast in patients with mild thyroid dysfunction: a prospective cohort study.
Hailong SI ; Kangyin CHEN ; Qin QIN ; Yuanyuan LIU ; Bingrang ZHAO
Chinese Medical Journal 2023;136(17):2044-2049
BACKGROUND:
More than 75 million procedures with intravascular iodine-based contrast media (ICM) are performed worldwide every year, and some patients undergoing these procedures do not have normal thyroid function. The long-term effects of ICM in patients with mild thyroid dysfunction (TD) are unclear.
METHODS:
This prospective cohort study was conducted in China. Patients with stable angina pectoris with total triiodothyronine (TT3) reduction, normal thyroid-stimulating hormone, and reverse triiodothyronine (rT3) were enrolled and divided into high-dose (≥100 mL ICM) and low-dose groups (<100 mL ICM). We dynamically investigated the trends in thyroid function, rT3, and thyroid antibodies one year after ICM exposure.
RESULTS:
A total of 154 patients completed 6 months of follow-up and 149 completed 1 year of follow-up. Thyroglobulin antibody (TGAB) levels were elevated in 41 (26.6%) patients before ICM exposure, 11 (7.1%) of whom also had elevated thyroid peroxidase antibody levels. Transient subclinical TD occurred 6 months after ICM exposure; 75.5% (34/45) of post-operative TD occurred in the high-dose group. One patient developed severe hypothyroidism with myxedema, requiring drug intervention 1 year after ICM exposure. The level of rT3 showed no statistically significant changes during post-operative follow-up ( P = 0.848). The TGAB level decreased at 6th month ( P < 0.001), but increased at 1 year after ICM exposure ( P = 0.002).
CONCLUSIONS
Patients with T3 reduction are at a risk of transient subclinical TD and hypothyroidism after a single large dose of ICM. Follow-up of this population at 9-12 months after ICM exposure is warranted.
Humans
;
Contrast Media/adverse effects*
;
Prospective Studies
;
Hypothyroidism
;
Triiodothyronine
;
Iodine/adverse effects*
;
Thyrotropin
;
Thyroxine
3.Research on magneto-acoustic-electrical tomography method based on liquid metal contrast agent and M sequence coded excitation.
Yuheng WANG ; Junjie LIN ; Wenshu MAI ; Zhipeng LIU ; Tao YIN ; Shunqi ZHANG
Journal of Biomedical Engineering 2023;40(4):718-724
Magneto-acoustic-electric tomography (MAET) boasts high resolution in ultrasound imaging and high contrast in electrical impedance imaging, making it of significant research value in the fields of early tumor diagnosis and bioelectrical monitoring. In this study, a method was proposed that combined high conductivity liquid metal and maximum length sequence (M sequence) coded excitation to improve the signal-to-noise ratio. It was shown that, under rotational scanning, the liquid metal significantly improved the signal-to-noise ratio of the inter-tissue magneto-acoustic-electric signal and enhanced the quality of the reconstructed image. The signal-to-noise ratio of the signal was increased by 5.6, 11.1, 21.7, and 45.7 times under the excitation of 7-, 15-, 31-, and 63-bit M sequence code, respectively. The total usage time of 31-bit M sequence coded excitation imaging was shortened by 75.6% compared with single-pulse excitation when the same signal-to-noise ratio was improved. In conclusion, the imaging method combining liquid metal and M-sequence coding excitation has positive significance for improving MAET image quality.
Contrast Media
;
Electricity
;
Electric Conductivity
;
Acoustics
;
Tomography
4.Experimental study on high-frequency subharmonic scattering characteristics of ultrasound contrast agent microbubbles under low ambient pressure.
Huimin LU ; Yun WANG ; Laixin HUANG ; Gang XU ; Juan ZHOU ; Wenkui YU ; Fei LI
Journal of Biomedical Engineering 2023;40(6):1209-1216
Correlation between nonlinear subharmonic scattering of ultrasound contrast agent microbubbles and ambient pressure is expected to be used for local brain tissue pressure monitoring. Although high-frequency ultrasound has achieved high-resolution imaging of intracranial microvessels, the research on high-frequency subharmonic scattering characteristics of microbubbles is insufficient at present, which restricts the research progress of estimating local brain tissue pressure based on high-frequency subharmonic scattering of microbubbles. Therefore, under the excitation of 10 MHz high-frequency ultrasound, the effects of different acoustic pressures and ambient pressures on the high-frequency subharmonic scattering characteristics of three different ultrasound contrast agents including SonoVue, Sonazoid and Huashengxian were investigated in this in vitro study. Results showed that the subharmonic scattering amplitudes of the three microbubbles increased with the increase of ambient pressure at the peak negative acoustic pressures of 696, 766 and 817 kPa, and there was a favorable linear correlation between subharmonic amplitude and ambient pressure. Under the above three acoustic pressures, the highest correlation coefficient of SonoVue was 0.948 ( P = 0.03), the highest sensitivity of pressure measurement was 0.248 dB/mm Hg and the minimum root mean square error (RMSE) was 2.64 mm Hg. Sonazoid's highest correlation coefficient was 0.982 ( P < 0.01), the highest sensitivity of pressure measurement was 0.052 dB/mm Hg and the minimum RMSE was 1.51 mm Hg. The highest correlation coefficient of Huashengxian was 0.969 ( P = 0.02), the highest sensitivity of pressure measurement was 0.098 dB/mm Hg and the minimum RMSE was 2.00 mm Hg. The above in vitro experimental results indicate that by selecting ultrasound contrast agent microbubbles and optimizing acoustic pressure, the correlation between high-frequency subharmonic scattering of microbubbles and ambient pressure can be improved, the sensitivity of pressure measurement can be upgraded, and the measurement error can be reduced to meet the clinical demand for local brain tissue pressure measurement, which provided an important experimental basis for subsequent research in vivo.
Contrast Media
;
Microbubbles
;
Ultrasonography/methods*
5.Research progress on desensitization of hypersensitivity reaction to iodinated contrast media.
Miao FAN ; Xiaomeng ZHENG ; Suyan ZHU
Journal of Zhejiang University. Medical sciences 2023;52(4):526-530
Desensitization therapy for iodinated contrast media (ICM) aims to induce drug tolerance in patients with a history of severe allergic reactions to ICM in a short time. Currently, there is no widely accepted consensus on inducing desensitization to avoid severe allergic responses to ICM. The clinically successful cases have shown that prophylactic use of antihistamines and glucocorticoids can increase the desensitization effect; repeatedly desensitizing and gradually increasing the dose can be conducive to establishing better tolerance to ICM. Most desensitization effects, including stress resistance, can endure 24-48 h. The mechanisms of desensitization therapy remain unclear, the initial dose, administration interval and dose gradient are largely based on clinical experiences and the reaction of patients. This article reviews the current research progress on ICM-related allergies, desensitization methods and related mechanisms, as well as the benefits and hazards of desensitization, to provide a reference for desensitization treatment of hypersensitivity to ICM .
Humans
;
Contrast Media/adverse effects*
;
Consensus
;
Glucocorticoids
;
Hypersensitivity
6.Association between acute adverse reactions to iodinated contrast media and anxiety in patients undergoing contrast-enhanced CT examination.
Journal of Central South University(Medical Sciences) 2023;48(8):1225-1233
OBJECTIVES:
As the use of iodinated contrast media has become more widely with advances in imaging, several guidelines have suggested that anxiety increases the risk of acute adverse reactions associated with iodinated contrast media. This study aims to evaluate the impact of anxiety on the occurrence of acute adverse reactions (AAR) to iodinated contrast media in patients undergoing contrast-enhanced CT examinations.
METHODS:
Inpatients who underwent contrast-enhanced CT examinations at the Third Xiangya Hospital between February and October 2021 were prospectively recruited. Prior to the imaging examinations, all patients completed the Generalized Anxiety Disorder Scale-7 (GAD-7) assessment before the imaging examinations to determine the severity of anxiety, which was categorized as mild, moderate, or severe. Based on the occurrence of AAR, patients were classified into an AAR group and a non-AAR group. The difference in anxiety was compared between the 2 groups. Multivariate logistic regression analysis was used to identify independent risk factors associated with AAR. To ensure comparability between the 2 groups, propensity score matching (PSM) was utilized to align the clinical characteristics. Subsequently, the difference in anxiety within the matched groups was analyzed.
RESULTS:
The study comprised 880 patients, with 80 patients in the AAR group and 800 patients in the non-AAR group. There was a significant difference in proportion of patients with mild-severe anxiety between the 2 groups (75% in the AAR group and 36% in the non-AAR group, P<0.001). Additionally, differences were also observed in occupation, income, underlying diseases, and allergy history (all P<0.001). The results of multivariate logistic regression analysis revealed that patients' income, allergy history, and anxiety were independent risk factors for AAR to iodinated contrast media (all P<0.05). Following PSM, each matched group included 66 cases, and no significant differences in clinical characteristics were observed between the 2 groups (all P>0.05). However, the proportion of patients with mild-severe anxiety remained significantly higher in the AAR group compared to the non-AAR group (75% in the AAR group and 31% in the non-AAR group, P<0.001).
CONCLUSIONS
Anxiety is associated with an increased risk of AAR to iodinated contrast media in patients undergoing contrast-enhanced CT examinations, suggesting the clinical importance of screening for anxiety before imaging examinations.
Humans
;
Contrast Media/adverse effects*
;
Tomography, X-Ray Computed/methods*
;
Risk Factors
;
Anxiety
;
Hypersensitivity/etiology*
;
Retrospective Studies
7.Prognostic significance of T2 mapping in evaluating myocardium alterations in patients with ST segment elevation myocardial infarction.
Qian CUI ; Qiang HE ; Xihong GE ; Guangfeng GAO ; Yang LIU ; Jing YU ; Hongle WANG ; Wen SHEN
Chinese Critical Care Medicine 2023;35(12):1304-1308
OBJECTIVE:
To investigate the value of T2 mapping in the assessment of myocardial changes and prognosis in patients with acute ST segment elevation myocardial infarction (STEMI).
METHODS:
A retrospective study was conducted. A total of 30 patients with acute STEMI admitted to Tianjin First Central Hospital from January 2021 to March 2022 were enrolled as the experimental group. At the same time, 30 age- and sex-matched healthy volunteers and outpatients with non-specific chest pain with no abnormalities in cardiac magnetic resonance (CMR) examination were selected as the control group. CMR was performed within 2 weeks after the diagnosis of STEMI, as the initial reference. A plain CMR review was performed 6 months later (chronic myocardial infarction, CMI). Plain scanning includes film sequence (CINE), T2 weighted short tau inversion recovery (T2-STIR), native-T1 mapping, and T2 mapping. Enhanced scanning includes first-pass perfusion, late gadolinium enhancement (LGE), and post-contrast T1 mapping. Quantitative myocardial parameters were compared between the two groups, before and after STEMI myocardial infarction. The receiver operator characteristic curve (ROC curve) was used to evaluate the diagnostic efficacy of native-T1 before myocardial contrast enhancement and T2 values in differentiating STEMI and CMI after 6 months.
RESULTS:
There were no statistically significant differences in age, gender, heart rate and body mass index (BMI) between the two groups, which were comparable. The native-T1 value, T2 value and extracellular volume (ECV) were significantly higher than those in the control group [native-T1 value (ms): 1 434.5±165.3 vs. 1 237.0±102.5, T2 value (ms): 48.3±15.6 vs. 21.8±13.1, ECV: (39.6±13.8)% vs. (22.8±5.0)%, all P < 0.05]. In the experimental group, 12 patients were re-examined by plain CMR scan 6 months later. After 6 months, the high signal intensity on T2-STIR was still visible, but the range was smaller than that in the acute phase, and the native-T1 and T2 values were significantly lower than those in the acute phase [native-T1 value (ms): 1 271.0±26.9 vs. 1 434.5±165.3, T2 value (ms): 34.2±11.2 vs. 48.3±15.6, both P < 0.05]. ROC curve analysis showed that the area under the ROC curve (AUC) of native-T1 and T2 values in differentiating acute STEMI from CMI was 0.71 and 0.80, respectively. When native-T1 cut-off value was 1 316.0 ms, the specificity was 100% and the sensitivity was 53.3%; when T2 cut-off value was 46.7 ms, the specificity was 100% and the sensitivity was 73.8%.
CONCLUSIONS
The T2 mapping is a non-invasive method for the diagnosis of myocardial changes in patients with acute STEMI myocardial infarction, and can be used to to evaluate the clinical prognosis of patients.
Humans
;
ST Elevation Myocardial Infarction/diagnosis*
;
Contrast Media
;
Prognosis
;
Retrospective Studies
;
Magnetic Resonance Imaging, Cine/methods*
;
Gadolinium
;
Myocardium/pathology*
;
Myocardial Infarction
;
Predictive Value of Tests
8.Multiparametric ultrasound for the assessment of testicular lesions with negative tumoral markers.
Hui LIU ; Lin DONG ; Li-Hua XIANG ; Guang XU ; Jing WAN ; Yan FANG ; Shi-Si DING ; Ye JIN ; Li-Ping SUN ; Hui-Xiong XU
Asian Journal of Andrology 2023;25(1):50-57
The purpose of this study was to evaluate the diagnostic performance of multiparametric ultrasound (mpUS; grayscale US, color Doppler US, strain elastography, and contrast-enhanced US) in the assessment of testicular lesions with negative tumoral markers. MpUS imaging data, patient age, serum tumor markers, scrotal pain, cryptorchidism, and related clinical information were retrospectively collected for patients who underwent mpUS examination between January 2013 and December 2019. Histologic results or follow-up examinations were used as the reference standard. In total, 83 lesions from 79 patients were included in the analysis. Fifty-six patients were finally diagnosed with benign tumors, and 23 patients were ultimately diagnosed with malignant tumors. Chi-square tests or Fisher's exact tests were used to assess the difference between the two groups. Stepwise multivariate logistic regression analysis showed that lesion diameter (odds ratio [OR] = 1.072, P = 0.005), vascularization on color Doppler US (OR = 4.066, P = 0.001), and hyperenhancement during the early phase (OR = 6.465, P = 0.047) were significant independent risk factors for malignancy; however, when compared with neoplastic lesions, pain (OR = 0.136, P < 0.001), absence of vascularization on color Doppler US (OR = 1.680, P = 0.042), and nonenhancement during the late phase (OR = 3.461, P = 0.031) were strongly associated with nonneoplastic lesions. MpUS features are useful for differentiating testicular lesions with negative tumoral markers and improving the preoperative diagnosis, which may avoid inappropriate radical orchiectomy.
Male
;
Humans
;
Testicular Neoplasms/pathology*
;
Biomarkers, Tumor
;
Retrospective Studies
;
Contrast Media
;
Ultrasonography/methods*
9.Advances in Molecular Targeted Ultrasound Contrast Agents.
Zhen YANG ; Ming-Bo ZHANG ; Yu-Kun LUO
Acta Academiae Medicinae Sinicae 2023;45(2):298-302
In real-time ultrasound,molecular targeted contrast agent is introduced into the blood circulation through peripheral intravenous injection to enhance the imaging signal of target lesions after binding to the corresponding intravascular receptors,which can realize early diagnosis,staging of diseases,assessment of treatment response,and targeted treatment.In addition,molecular targeted ultrasound contrast agents provide a platform for the delivery of drugs and genes via microbubbles,and nanoscale contrast agents can be infiltrated through vascular endothelium into the interstitial space of the lesion for imaging or treatment.The available studies of molecular targeted ultrasound contrast agents mainly focus on the preclinical trials.Some clinical trials have been conducted in humans and preliminarily confirm the safety and feasibility of targeted ultrasound contrast agents.The molecular targeted ultrasound contrast agents enjoy a broad prospect in clinical application.
Humans
;
Contrast Media/chemistry*
;
Molecular Targeted Therapy
;
Ultrasonography/methods*
;
Diagnostic Imaging
10.Relationship of Microvascular Obstruction with Global and Regional Myocardial Function Determined by Cardiac Magnetic Resonance after ST-Segment Elevation Myocardial Infarction.
Ya-Nan ZHAO ; Jia-Ning CUI ; Xing-Hua ZHANG ; Jin-Feng LI ; Shi-Min CHEN ; Xiu-Zheng YUE ; Tao LI
Chinese Medical Sciences Journal 2023;38(1):11-19
Objective To investigate the impact of microvascular obstruction (MVO) on the global and regional myocardial function by cardiac magnetic resonance feature-tracking (CMR-FT) in ST-segment-elevation myocardial infarction (STEMI) patients after percutaneous coronary intervention.Methods Consecutive acute STEMI patients who underwent cardiac magnetic resonance imaging 1 - 7 days after successful reperfusion by percutaneous coronary intervention treatment were included in this retrospective study. Based on the presence or absence of MVO on late gadolinium enhancement images, patients were divided into groups with MVO and without MVO. The infarct zone, adjacent zone, and remote zone were determined based on a myocardial 16-segment model. The radial strain (RS), circumferential strain (CS), and longitudinal strain (LS) of the global left ventricle (LV) and the infarct, adjacent, and remote zones were measured by CMR-FT from cine images and compared between patients with and without MVO using independent-samples t-test. Logistic regression analysis was used to assess the association of MVO with the impaired LV function.Results A total of 157 STEMI patients (mean age 56.66 ± 11.38 years) were enrolled. MVO was detected in 37.58% (59/157) of STEMI patients, and the mean size of MVO was 3.00 ±3.76 mL. Compared with patients without MVO (n =98 ), the MVO group had significantly reduced LV global RS (t= -4.30, P < 0.001), global CS (t= 4.99, P < 0.001), and global LS ( t= 3.51, P = 0.001). The RS and CS of the infarct zone in patients with MVO were significantly reduced (t= -3.38, P = 0.001; t= 2.64, P = 0.01; respectively) and the infarct size was significantly larger (t= 8.37, P < 0.001) than that of patients without MVO. The presence of LV MVO [OR= 4.10, 95%CI: 2.05 - 8.19, P<0.001) and its size [OR=1.38, 95%CI: 1.10-1.72, P=0.01], along with the heart rate and LV infarct size were significantly associated with impaired LV global CS in univariable Logistic regression analysis, while only heart rate (OR=1.08, 95%CI: 1.03 - 1.13, P=0.001) and LV infarct size (OR=1.10, 95%CI: 1.03 - 1.16, P=0.003) were independent influencing factors for the impaired LV global CS in multivariable Logistic regression analysis.Conclusion The infarct size was larger in STEMI patients with MVO, and MVO deteriorates the global and regional LV myocardial function.
Humans
;
Middle Aged
;
Aged
;
ST Elevation Myocardial Infarction/complications*
;
Contrast Media
;
Retrospective Studies
;
Gadolinium
;
Magnetic Resonance Imaging
;
Magnetic Resonance Spectroscopy
;
Percutaneous Coronary Intervention

Result Analysis
Print
Save
E-mail