1.Advances in low-frequency ultrasound combined with microbubbles in targeted tumor therapy.
Journal of Zhejiang University. Science. B 2019;20(4):291-299
The development of low-frequency ultrasound imaging technology and the improvement of ultrasound contrast agent production technology mean that they play an increasingly important role in tumor therapy. The interaction between ultrasound and microbubbles and their biological effects can transfer and release microbubbles carrying genes and drugs to target tissues, mediate the apoptosis of tumor cells, and block the embolization of tumor microvasculature. With the optimization of ultrasound parameters, the development of targeted microbubbles, and the emergence of various composite probes with both diagnostic and therapeutic functions, low-frequency ultrasound combined with microbubble contrast agents will bring new hope for clinical tumor treatment.
Antineoplastic Agents/therapeutic use*
;
Apoptosis
;
Autophagy
;
Cell Membrane Permeability
;
Cell Proliferation
;
Contrast Media/administration & dosage*
;
Drug Delivery Systems
;
Humans
;
Microbubbles
;
Microcirculation
;
Neoplasm Invasiveness
;
Neoplasm Metastasis
;
Neoplasms/therapy*
;
Patient Safety
;
Transfection
;
Ultrasonic Therapy/methods*
2.Development of Biliary Contrast Agents Remote Pushing Device.
Haoyang ZHU ; Dinghui DONG ; Yu LUO ; Fenggang REN ; Jing ZHANG ; Wenjun TAN ; Aihua SHI ; Liangshuo HU ; Rongqian WU ; Yi LYU
Chinese Journal of Medical Instrumentation 2018;42(1):11-13
A biliary contrast agents pushing device, including a syringe pushing system and a remote controller is introduced. The syringe pushing system comprises an injector card slot, a support platform and an injection bolus fader. A 20 mL syringe can be fitted on the syringe pushing system and kept with the ground about 30 degree. This system can perform air bubble pumping back and contrast agents bolus injection as well as speed adjustment. Remote controller is an infrared remote control which can start and stop the syringe pushing system. With this device, the remote controlled cholangiography technology can be achieved, which can not only protect doctors from X-ray radiation but also improve the traditional T-tube cholangiography and the contrast effect, reduce postoperative complications in patients as well. The application of this device will improve the current diagnosis and treatment system, the device will benefit the majority of doctors and patients.
Contrast Media
;
administration & dosage
;
Humans
;
Injections
;
Postoperative Complications
;
Syringes
3.Clinical application of the disposable vasographic interventional therapy kit in vasoseminal vesiculography.
Jia-Dong XIA ; Yang LI ; You-Feng HAN ; Jie YANG ; Rui-Peng JIA ; Yu-Tian DAI ; Xue-Jun SHANG ; Zeng-Jun WANG
National Journal of Andrology 2018;24(2):122-127
Objective:
To investigate the success rate and safety of percutaneous vasoseminal vesiculography with the disposable vasographic interventional therapy kit (VITK).
METHODS:
This study included ninety-six 19-65 (mean 43) years old male patients with infertility, hematospermia, seminal vesicle cyst, ejaculatory duct cyst, ejaculatory dysfunction, or vas deferens injury, with disease courses varying from 1 month to 7 years. With an open, multi-centered, single-group, self-controlled design and using the disposable VITK, we treated the patients by percutaneous vasoseminal vesiculography via injection of contrast medium into the vas deferens cavity under local anesthesia.
RESULTS:
Percutaneous vasoseminal vesiculography was successfully performed in 92 (97.87%) of the patients, which revealed abnormal seminal ducts in 51 cases (54.3%). Among the 28 infertile patients, 3 were found with bilateral and 5 with unilateral vas deferens obstruction. Vesiculitis was detected in 36 (81.8%) of the 44 hematospermia patients and bilateral vas deferens abnormality in 5 (38.5%) of the 13 patients with ejaculatory dysfunction. Transectional damage was observed in 2 patients with vas deferens injury induced by bilateral inguinal hernia repair. Three cases of seminal vesicle cyst and 4 cases of ejaculatory cyst were definitely diagnosed by vasoseminal vesiculography.
CONCLUSIONS
The disposable vasographic interventional therapy kit, with the advantages of simple operation and high safety, deserves a wide clinical application in vasoseminal vesiculography.
Adult
;
Aged
;
Contrast Media
;
administration & dosage
;
Cysts
;
diagnostic imaging
;
Ejaculatory Ducts
;
diagnostic imaging
;
Genital Diseases, Male
;
diagnostic imaging
;
Hemospermia
;
diagnostic imaging
;
etiology
;
Hernia, Inguinal
;
surgery
;
Humans
;
Infertility, Male
;
diagnostic imaging
;
Injections
;
Male
;
Middle Aged
;
Postoperative Complications
;
diagnostic imaging
;
etiology
;
Radiography
;
methods
;
Seminal Vesicles
;
diagnostic imaging
;
Vas Deferens
;
diagnostic imaging
;
injuries
;
Young Adult
4.Life-Threatening Thrombocytopenia Following Intravenous Contrast Media Infusion
Mihwa PARK ; Minjeong KIM ; Jisun PARK ; Jinhyun CHO
Yonsei Medical Journal 2018;59(1):158-161
Radiocontrast media-induced acute severe thrombocytopenia is a very rare complication and potentially life-threatening. Here, we report the case of a 63-year-old male patient with severe acute thrombocytopenia following first exposure to intravenous non-ionic contrast media without immediate allergic reactions. His platelet count dropped from 107000/µL to 2000/µL after six hours of radiocontrast infusion. After administration of corticosteroid and transfusion of platelet concentrates, the platelet count returned gradually to normal within 5 days. To the best of our knowledge, non-ionic contrast media-induced isolated acute severe thrombocytopenia following no signs or symptoms of immediate allergic reaction has never been described.
Acute Disease
;
Administration, Intravenous
;
Contrast Media/administration & dosage
;
Contrast Media/adverse effects
;
Humans
;
Infusions, Intravenous
;
Male
;
Middle Aged
;
Platelet Count
;
Thrombocytopenia/etiology
5.Rat Cerebrospinal Fluid Treatment Method through Cisterna Cerebellomedullaris Injection.
Thainá Garbino DOS SANTOS ; Mery Stéfani Leivas PEREIRA ; Diogo Losch OLIVEIRA
Neuroscience Bulletin 2018;34(5):827-832
Drugs that lack the ability to cross the blood-brain barrier (BBB) need to be placed directly into the central nervous system. Our laboratory studies the involvement of the glutamatergic system in the aggressiveness of glioma, and some ligands of glutamate receptors cannot permeate the BBB. Here, glioma-implanted rats were treated by a technique that delivers ligands directly into the cerebrospinal fluid by puncture into the cisterna cerebellomedullaris. Rats were anesthetized and fixed in a rodent stereotactic device. The head was gently tilted downwards at an angle that allowed exposure of the cisterna. Injection into the cisterna was done freehand using a gingival needle coupled to a microsyringe. The efficiency of intracisternal injection was demonstrated using a methylene blue solution. This type of injection is adaptable for any rodent model using small volumes of a variety of other drugs, and is an interesting method for neuroscience studies.
Anesthesia
;
Animals
;
Central Nervous System Agents
;
administration & dosage
;
Cerebrospinal Fluid
;
Cisterna Magna
;
Contrast Media
;
Excitatory Amino Acid Agents
;
administration & dosage
;
Glioma
;
drug therapy
;
Methylene Blue
;
Models, Animal
;
Rats, Wistar
6.Can Fundus Fluorescein Angiography be Performed for Diabetic Patients on Oral Metformin?.
Chinese Medical Sciences Journal 2017;32(2):119-112
Metformin is a kind of biguanide hypoglycemic agent that has been widely used in patients with diabetes mellitus. In clinical practice, whether metformin should be stopped before Fundus fluorescein angiography (FFA) remains largely unclear. Some endocrinologists suggest stop metformin before FFA. However, ophthalmologists do not always adopt this opinion in their practice. This situation may lead to disputes between physicians and patients. This article analyzed contrast-induced nephropathy(CIN) and the related contrast agent, as well as the adverse reactions of fluorescein angiography. It pointed out that the discrepancy may be caused by misunderstanding of contrast agents used in FFA. For angiography using iodine contrast agent, metformin must be stopped because of the increased possibility of CIN, while for FFA using fluorescein sodium, no CIN has been reported yet. Therefore, the authors believe FFA is safe for diabetic patients with oral metformin and it is unnecessary to stop metformin before the examination.
Administration, Oral
;
Contrast Media
;
adverse effects
;
Diabetes Mellitus, Type 2
;
diagnostic imaging
;
drug therapy
;
Diabetic Retinopathy
;
diagnostic imaging
;
Fluorescein Angiography
;
adverse effects
;
methods
;
Humans
;
Hypoglycemic Agents
;
therapeutic use
;
Kidney Diseases
;
chemically induced
;
Metformin
;
therapeutic use
7.The Effectiveness of Ferritin as a Contrast Agent for Cell Tracking MRI in Mouse Cancer Models.
Chan Wha LEE ; Sun Il CHOI ; Sang Jin LEE ; Young Taek OH ; Gunwoo PARK ; Na Yeon PARK ; Kyoung Ah YOON ; Sunshin KIM ; Daehong KIM ; Yun Hee KIM ; Jin Suck SUH
Yonsei Medical Journal 2017;58(1):51-58
PURPOSE: We aimed to investigate the effectiveness of ferritin as a contrast agent and a potential reporter gene for tracking tumor cells or macrophages in mouse cancer models. MATERIALS AND METHODS: Adenoviral human ferritin heavy chain (Ad-hFTH) was administrated to orthotopic glioma models and subcutaneous colon cancer mouse models using U87MG and HCT116 cells, respectively. Brain MR images were acquired before and daily for up to 6 days after the intracranial injection of Ad-hFTH. In the HCT116 tumor model, MR examinations were performed before and at 6, 24, and 48 h after intratumoral injection of Ad-hFTH, as well as before and every two days after intravenous injection of ferritin-labeled macrophages. The contrast effect of ferritin in vitro was measured by MR imaging of cell pellets. MRI examinations using a 7T MR scanner comprised a T1-weighted (T1w) spin-echo sequence, T2-weighted (T2w) relaxation enhancement sequence, and T2*-weighted (T2*w) fast low angle shot sequence. RESULTS: Cell pellet imaging of Ad-hFTH in vitro showed a strong negatively enhanced contrast in T2w and T2*w images, presenting with darker signal intensity in high concentrations of Fe. T2w images of glioma and subcutaneous HCT116 tumor models showed a dark signal intensity around or within the Ad-hFTH tumor, which was distinct with time and apparent in T2*w images. After injection of ferritin-labeled macrophages, negative contrast enhancement was identified within the tumor. CONCLUSION: Ferritin could be a good candidate as an endogenous MR contrast agent and a potential reporter gene that is capable of maintaining cell labeling stability and cellular safety.
Animals
;
Brain Neoplasms/*diagnostic imaging/pathology
;
Cell Line, Tumor
;
Cell Tracking/*methods
;
Colonic Neoplasms/*diagnostic imaging/pathology
;
*Contrast Media/administration & dosage
;
Disease Models, Animal
;
Female
;
*Ferritins/administration & dosage
;
Genes, Reporter
;
Glioma/*diagnostic imaging/pathology
;
Humans
;
Injections, Intravenous
;
Macrophages
;
Magnetic Resonance Imaging/*methods
;
Male
;
Mice
;
Neoplasm Transplantation
;
Skin Neoplasms/*diagnostic imaging/pathology
;
Time Factors
8.Application value of Toshiba 320-row dynamic volumetric CT angiography in the diagnosis of venous erectile dysfunction.
Guo-Yao WANG ; Cheng-Cheng XU ; Ke-Rong WU ; Guan-Lin LIU ; Jie ZHANG ; Yu-Ning PAN ; Yi-Fan TANG
National Journal of Andrology 2016;22(7):635-640
ObjectiveTo investigate the application value of Toshiba 320-row dynamic volumetric CT angiography in the diagnosis of venous erectile dysfunction (VED).
METHODSWe enrolled in this study 33 patients diagnosed with ED by audiovisual sexual stimulation screening in the outpatient department. Penile erection was induced in the patients by injection of 2 mg phentolamine plus 30 mg papaverine into the corpus cavernosum, followed by that of contrast agent of iobitridol through the vein and corpus cavernosum successively. Then 320-row dynamic volumetric CT angiography was performed and the images of the corpus cavernosum in the arterial and venous phases were collected and processed.
RESULTSDifferent degrees of abnormal venous drainage were observed in 29 of the patients, including 7 cases (24.1%) of back deep venous leakage, 6 cases (20.7%) of foot venous leakage, 3 cases (10.3%) of dorsal superficial venous leakage, 1 case (3.5%) of intervertebral venous leakage, 2 cases (6.9%) of cavernous venous leakage, and 10 cases (34.5%) of mixed venous leakage. Ten of the patients underwent surgery, dorsal deep penile vein ligation in 2 cases, dorsal deep vein embedding plus foot vein ligation in 4, and foot vein ligation in the other 4. Eight of the patients were followed up for 3-12 months post-operatively, during which 2 achieved obvious erectile improvement, while the other 6 gained normal penile erection.
CONCLUSIONSToshiba 320-row dynamic volumetric CT angiography is a reliable method for the diagnosis of VED, which displays the precise location of venous leakage for clinical treatment, with the advantages of clearer images, lower doses of contrast agent and radiation, and faster examination than X-ray penile angiography.
Adult ; Arteries ; diagnostic imaging ; Computed Tomography Angiography ; Contrast Media ; Drug Combinations ; Erectile Dysfunction ; diagnostic imaging ; Humans ; Injections ; Iohexol ; analogs & derivatives ; Ligation ; Male ; Middle Aged ; Papaverine ; administration & dosage ; Penile Erection ; Penis ; diagnostic imaging ; physiopathology ; Phentolamine ; administration & dosage ; Veins ; diagnostic imaging ; surgery
9.Immediate-type hypersensitivity response to systemic hydrocortisone sodium succinate.
Ji Hyang LEE ; Hye Seon OH ; Byoung Soo KWON ; Hyngjun PARK ; Soyoung PARK ; Jung Hyun KIM ; Hyo Jung KIM ; Hyouk Soo KWON ; You Sook CHO ; Hee Bom MOON ; Tae Bum KIM
Allergy, Asthma & Respiratory Disease 2016;4(5):378-381
Immediate-type hypersensitivity responses to systemic corticosteroids are rare despite their widespread use. It is still controversial whether the responses rarely occur or are underdiagnosed in clinical settings. Many cases probably remain underdiagnosed because the symptoms often mimic symptoms of underlying diseases. This case report describes a 73-year-old man who had immediate hypersensitivity reactions after intravenous administration of hydrocortisone, which was primarily intended to prevent hypersensitivity reactions to contrast media. Whole body rash with pruritus developed shortly after the steroid injection. Since the patient already experienced rash and itching sense after contrast media and antihistamine injection, we conducted skin testing to figure out which drug triggered the hypersensitivity reactions. Intradermal skin tests revealed a positive response to hydrocortisone sodium succinate, which suggested his hypersensitivity reactions were developed by hydrocortisone. Being a common therapy for allergic reaction, corticosteroids themselves are rarely suspected of causing hypersensitivity reactions. Considering there is no typical symptom or standard diagnostic test, awareness of corticosteroid hypersensitivity reactions is of importance to make the diagnosis.
Administration, Intravenous
;
Adrenal Cortex Hormones
;
Aged
;
Contrast Media
;
Diagnosis
;
Diagnostic Tests, Routine
;
Drug Hypersensitivity
;
Exanthema
;
Humans
;
Hydrocortisone*
;
Hypersensitivity*
;
Hypersensitivity, Immediate
;
Intradermal Tests
;
Pruritus
;
Skin Tests
;
Sodium*
;
Succinic Acid*
10.Changes in endolymphatic hydrops visualized by magnetic resonance imaging after sac surgery.
Yuan ZHANG ; Yong-Hua CUI ; Ying HU ; Zhong-Yao MAO ; Qiu-Xia WANG ; Chu PAN ; Ai-Guo LIU
Journal of Huazhong University of Science and Technology (Medical Sciences) 2016;36(5):736-740
The purpose of the study was to observe changes in endolymphatic hydrops by using intratympanic injection of gadolinium and magnetic resonance imaging (MRI) before and after endolymphatic sac surgery in patients with unilateral Meniere's disease. Thirteen patients with unilateral Meniere's disease undergoing endolymphatic sac surgery were retrospectively and prospectively analyzed. Three-dimensional fluid-attenuated inversion recovery or three-dimensional real inversion recovery MRI was performed 24 h after an intratympanic injection of gadolinium to grade the presence of endolymphatic hydrops. Among the 13 patients with hydrops confirmed by preoperative MRI, vestibular hydrops had no significant change in all patients; cochlear hydrops became negative in 2 patients, and remained unchanged in the other 11 patients after surgery. Definite vertigo attacks were substantially controlled in one patient and completely controlled in 12 patients during a follow-up period of 8-34 months after surgery. The hearing levels were improved in 3 patients, remained unchanged in 7 patients, and decreased in 3 patients. In conclusion, endolymphatic sac surgery does not always alleviate endolymphatic hydrops in patients with Meniere's disease. Relief from vertigo cannot always be attributed to the remission of hydrops. A change in hearing levels cannot be explained by hydrops status alone.
Adult
;
Aged
;
Contrast Media
;
administration & dosage
;
Endolymphatic Hydrops
;
diagnostic imaging
;
pathology
;
surgery
;
Endolymphatic Sac
;
diagnostic imaging
;
pathology
;
surgery
;
Female
;
Gadolinium
;
administration & dosage
;
Humans
;
Imaging, Three-Dimensional
;
Magnetic Resonance Imaging
;
Male
;
Meniere Disease
;
diagnostic imaging
;
pathology
;
surgery
;
Middle Aged

Result Analysis
Print
Save
E-mail