1.Impact of prolonged exposure to video display terminals on macular pigment optical density in young adult Filipinos.
Ronald Y. TIU ; Eleonore B. IGUBAN
Philippine Journal of Ophthalmology 2025;50(1):43-49
OBJECTIVE
This study assessed the correlation of macular pigment optical density (MPOD) and varying levels of exposure to video display terminals (VDT) among young adult Filipinos.
METHODSThis cross-sectional, analytical, single-center study compared the MPOD, measured using the Zeiss VISUCAM 500, between two groups of individuals aged 20 to 35 years old with differing VDT exposure. The more exposed group consisted of individuals who spent at least 8 hours per day on VDTs for the past 1 year, while the less exposed group spent less than 6 hours per day. Student’s t-test and chi-square test were used to compare the two groups, while Pearson's r coefficient was utilized to determine the relationship between MPOD and VDT exposure.
RESULTSA total of 80 individuals (40 in each group) were included in the study. Both groups had similar profiles, except for refractive errors, which were significantly higher in the prolonged VDT exposure group (p = 0.02). The prolonged exposure group averaged 10 hours of VDT use per day, compared to 3 hours in the low VDT exposure group. The MPOD level, particularly the maximum optical density (Max OD), was significantly lower in the prolonged VDT exposure group (0.2034 DU) compared to the low VDT exposure group (0.2467 DU) (p = 0.0051). A negative weak correlation was observed between the VDT exposure hours and MPOD levels (Max OD r = –0.387, p = 0.0005).
CONCLUSIONThis study found a weak but significant negative correlation between prolonged VDT exposure and lower MPOD levels, suggesting that extended screen time may contribute to reduced macular pigment density. While the correlation was weak (r = –0.387), these findings underscore the potential risk of diminished macular health with increased VDT use. The results highlight the importance of promoting protective strategies, such as reducing screen time and encouraging dietary or lifestyle changes that support eye health, especially among individuals with high VDT exposure.
Human ; Video Display Terminals (vdt) ; Computer Terminals
2.Combination of acupuncture and medication for dry eye complicated with computer vision syndrome: a randomized controlled trial.
Lei ZHAO ; Bao-Qiang DONG ; Tao ZUO ; Zhu-Qiang ZHANG ; Fang-Yuan WANG ; Hui-Min ZHOU
Chinese Acupuncture & Moxibustion 2023;43(10):1134-1138
OBJECTIVE:
To compare the clinical efficacy of acupuncture, Chinese medication and combination of acupuncture and medication in the treatment of dry eye complicated with computer vision syndrome (CVS).
METHODS:
A total of 152 patients with dry eye complicated with CVS were randomly divided into an acupuncture-medication group (38 cases, 1 case was removed), an acupuncture group (38 cases, 1 case dropped off), a Chinese medication group (38 cases, 1 case was removed), and a western medication group (38 cases, 1 case dropped off). In the western medication group, sodium hyaluronate eye drop combined with esculin and digitalis glycosides eye drop were used. In the acupuncture group, acupuncture was applied at bilateral Taiyang (EX-HN 5), Cuanzhu (BL 2), Fengchi (GB 20), Qimen (LR 14) , and Hegu (LI 4) etc., once a day. In the Chinese medication group, Yiqi Congming decoction formula ganule was given orally, one dose a day. In the acupuncture-medication group, acupuncture combined with Yiqi Congming decoction formula granule were used. All groups were treated for 14 d. The non-invasive first tear film break-up time (NIBUT f), non-invasive average tear film break-up time (NIBUT av), tear meniscus height (TMH), ocular surface disease index (OSDI) score, and CVS symptom score were compared between the patients of each group before and after treatment.
RESULTS:
After treatment, the NIBUT f, NIBUT av, and TMH were increased compared with those before treatment in the patients of the 4 groups (P<0.01); the NIBUT f and NIBUT av in the acupuncture-medication group and the acupuncture group were higher than those in the Chinese medication group and the western medication group (P<0.05), and the TMH in the acupuncture-medication group and the Chinese medication group were higher than those in the acupuncture group and the western medication group (P<0.05). After treatment, the OSDI scores, the various scores and total scores of CVS (except for head symptom score in the western medication group) were decreased compared with those before treatment in the patients of the 4 groups (P<0.01). The OSDI score, total score, eye symptom score, and body symptom score of CVS in the acupuncture-medication group were lower than those in the acupuncture group, the Chinese medication group, and the western medication group (P<0.01, P<0.05), the head symptom score of the acupuncture-medication group was lower than that in the western medication group (P<0.05), and the CVS physical symptom scores and mental cognitive symptom scores of the acupuncture-medication group and the acupuncture group were lower than those in the Chinese medication group and the western medication group (P<0.05).
CONCLUSION
Acupuncture has advantages in improving NIBUT f, NIBUT av, and CVS physical symptoms and cognitive symptoms, and the Chinese medication has advantage in improving TMH. The combination of acupuncture and Chinese medication has better effects compared with monotherapy.
Humans
;
Dry Eye Syndromes/etiology*
;
Acupuncture Therapy
;
Computers
;
Treatment Outcome
;
Acupuncture Points
;
Ophthalmic Solutions
3.Computer-simulated osteotomy based on health-side combined with guide plate technique in treatment of cubitus varus deformity in adolescents.
Jiaqiang WU ; Wenqiang XU ; Chaoyu LIU ; Yongfei FAN ; Xiulin MA ; Qixin LIU ; Jianqiang ZHANG ; Wei WANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1214-1219
OBJECTIVE:
To explore the feasibility and early effectiveness of computer-simulated osteotomy based on the health-side combined with guide plate technique in the treatment of cubitus varus deformity in adolescents.
METHODS:
The clinical data of 23 patients with cubitus varus deformity who met the selection criteria between June 2019 and February 2023 were retrospectively analyzed. There were 17 males and 6 females, ranging in age from 4 to 16 years with an average of 8.5 years. The time from injury to operation was 1-4 years. The angle of distal humerus rotation was defined by humeral head posterior inclination angle using low radiation dose CT to scan the patient's upper extremity data at one time, and the preoperative rotation of the distal humerus on the affected side was (33.82±4.39)°. The CT plain scan data were imported into 9yuan3D digital orthopaedic system (V3.34 software) to reconstruct three-dimensional images of both upper extremities. The simulated operation was performed with the healthy upper extremity as the reference, the best osteotomy scheme was planned, overlapped and compared, and the osteotomy guide plate was prepared. The patients were followed up regularly after operation, and the formation of callus in the osteotomy area was observed by X-ray examination. Before and after operation, the carrying angle of both upper extremities (the angle of cubitus valgus was positive, and the angle of cubitus varus was negative) and anteversion angle were measured on X-ray and CT images. At the same time, the flexion and extension range of motion of elbow joint and the external rotation range of motion of upper extremity were measured, and Mayo score was used to evaluate the function of elbow joint.
RESULTS:
The operation time ranged from 34 to 46 minutes, with an average of 39 minutes. All patients were followed up 5-26 months, with a mean of 14.9 months. All the incisions healed by first intention after the operation; 2 patients had nail path irritation symptoms after Kirschner wire fixation, which improved after dressing change; no complication such as breakage and loosening of internal fixators occurred after regular X-ray review. Continuous callus formed at the osteotomy end at 4 weeks after operation, and the osteotomy end healed at 8-12 weeks after operation. At last follow-up, the carrying angle, anteversion angle, external rotation range of motion, and extension and flexion range of motion of the elbow joint of the affected side significantly improved when compared with preoperative ones ( P<0.05). Except for the extension range of motion of the healthy elbow joint ( P<0.05), there was no significant difference in other indicators between the two sides ( P>0.05). At last follow-up, the Mayo elbow score was 85-100, with an average of 99.3; 22 cases were excellent, 1 case was good, and the excellent and good rate was 100%.
CONCLUSION
Computer-simulated osteotomy based on health-side combined with guide plate technique for treating cubitus varus deformity in adolescents can achieve precise osteotomy, which has the advantages of short operation time and easy operation, and the short-term effectiveness is satisfactory.
Male
;
Female
;
Humans
;
Adolescent
;
Child, Preschool
;
Child
;
Elbow
;
Humeral Fractures/surgery*
;
Retrospective Studies
;
Joint Deformities, Acquired/surgery*
;
Elbow Joint/surgery*
;
Limb Deformities, Congenital
;
Osteotomy/methods*
;
Humeral Head
;
Range of Motion, Articular
;
Computers
;
Treatment Outcome
4.Design and Experimental Research of Synchronous Acquisition System of EMG and Blood Oxygen Signal.
Mengjie ZANG ; Lidong XING ; Zhiyu QIAN ; Liuye YAO
Chinese Journal of Medical Instrumentation 2023;47(1):54-60
In this study, a surface electromyography (sEMG) and blood oxygen signal real-time monitoring system is designed to explore the changes of physiological signals during muscle fatigue, so as to detect muscle fatigue. The analysis method of sEMG and the principle of blood oxygen detection are respectively introduced, and the system scheme is expounded. The hardware part of the system takes STM32 as the core. Conditioning module composition; blood oxygen signal acquisition is based on near infrared spectroscopy (NIRS), specifically including light source, light source driving, photoelectric conversion, signal conditioning and other modules. The system software part is based on the real-time uC/OS-III software system. The characteristic parameters of sEMG were extracted by isometric contraction local muscle fatigue experiment; the relative changes of oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) were calculated in the forearm blocking experiment, thereby verifying that the system collects two signals effectiveness.
Muscle, Skeletal
;
Oxygen
;
Electromyography
;
Muscle Fatigue/physiology*
;
Computers
5.Research on Logic Design of Proton Treatment Control System.
Zhuofan CAI ; Rong XIE ; Jianchun DENG ; Zhiyong YANG
Chinese Journal of Medical Instrumentation 2023;47(4):370-376
The proton treatment control system is the supporting software of the proton therapy device, which specifically coordinates and controls the status and work of each subsystem. In this study, the software architecture and hardware implementation of the proton treatment control system was developed and built a foundation for the overall debugging. Using C# programming language and WPF programming techniques, TCP network communication protocol specified by the proton treatment technical document and MVVM pattern in Windows system, the logic design and implementation of each level were studied. Meanwhile, the communication interface between the subsystems under TCP communication protocol was agreed. The logic design and research of the setup field and treatment field were carried out. And the User Interface was designed and developed using the above technology. The program realizes the communication and interaction between the proton treatment control system and each subsystem, so as to control and monitor the whole treatment process. The proton treatment control system provides a software basis for the remote overall debugging and on-line monitor and control of proton treatment device.
Protons
;
User-Computer Interface
;
Software
;
Computers
;
Logic
6.Key technology of brain-computer interaction based on speech imagery.
Yanpeng LIU ; Anmin GONG ; Peng DING ; Lei ZHAO ; Qian QIAN ; Jianhua ZHOU ; Lei SU ; Yunfa FU
Journal of Biomedical Engineering 2022;39(3):596-611
Speech expression is an important high-level cognitive behavior of human beings. The realization of this behavior is closely related to human brain activity. Both true speech expression and speech imagination can activate part of the same brain area. Therefore, speech imagery becomes a new paradigm of brain-computer interaction. Brain-computer interface (BCI) based on speech imagery has the advantages of spontaneous generation, no training, and friendliness to subjects, so it has attracted the attention of many scholars. However, this interactive technology is not mature in the design of experimental paradigms and the choice of imagination materials, and there are many issues that need to be discussed urgently. Therefore, in response to these problems, this article first expounds the neural mechanism of speech imagery. Then, by reviewing the previous BCI research of speech imagery, the mainstream methods and core technologies of experimental paradigm, imagination materials, data processing and so on are systematically analyzed. Finally, the key problems and main challenges that restrict the development of this type of BCI are discussed. And the future development and application perspective of the speech imaginary BCI system are prospected.
Brain
;
Computers
;
Humans
;
Imagery, Psychotherapy
;
Speech
;
Technology
7.Effect of computer navigation gap balance technology on lower limb recovery after total knee arthroplasty.
Chen WANG ; Li-Jun FENG ; Jin-Ting ZHAO
China Journal of Orthopaedics and Traumatology 2022;35(1):43-48
OBJECTIVE:
To investigate the effect of computer navigation gap balance technology on the recovery of lower limb function after total knee arthroplasty.
METHODS:
The clinical data of 106 patients with knee osteoarthritis (OA) who underwent total knee arthroplasty from July 2018 to June 2019 were analyzed retrospectively. They were divided into measurement osteotomy group and space balance group according to different osteotomy techniques during total knee arthroplasty. There were 61 cases in osteotomy group, 24 males and 37 females;The age ranged from 45 to 77(63.35±4.26) years;According to K-L classification, 41 cases were grade Ⅲ and 20 cases were grade Ⅳ. intraoperative measurement osteotomy was performed. There were 45 cases in the gap balance group, 17 males and 28 females;Age 45 to 78(64.03±4.31) years;According to K-L classification, 29 cases were classified as grade Ⅲ and 16 cases as grade Ⅳ. computer navigation gap balance technology was implemented. The amount of intraoperative bleeding, operation time, incision length, hospital stay and postoperative complications were compared between two groups. The clinical efficacy was evaluated by Knee Society score(KSS) before operation and 12 months after operation.
RESULTS:
Total of 106 patients were followed up for 12 to 18(20.38±3.25) months. There were significant differences in intraoperative bleeding and operation time between two groups(P<0.05). There was no significant difference in incision length and hospital stay between the two groups(P>0.05). At 12 months after operation, the total score of KSS in the gap balance group (173.59±14.50) was better than that in the osteotomy group (164.95±12.10)(P<0.05). There were no serious complications of poor prosthesis loosening between two groups during follow-up, and there was no significant difference in the incidence of other complications between two groups(P>0.05).
CONCLUSION
The application of computer navigation gap balance technology in total knee arthroplasty is conducive to the recovery of lower limb function in patients with OA, and there are no serious adverse complications and high safety.
Aged
;
Arthroplasty, Replacement, Knee
;
Computers
;
Female
;
Humans
;
Knee Joint/surgery*
;
Knee Prosthesis
;
Lower Extremity
;
Male
;
Middle Aged
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Technology
;
Treatment Outcome
8.Effect of computer virtual technique combined with pelvic reduction frame in the treatment of type C pelvic fracture.
Chen HUANG ; Wei ZHENG ; Ya-Ming REN ; Shao-Lin DENG ; Dong-Fa LIAO
China Journal of Orthopaedics and Traumatology 2022;35(4):323-328
OBJECTIVE:
To investigate the short-term clinical effect of the computer virtual technique combined with pelvic reduction frame in the treatment of complex pelvic fractures.
METHODS:
Thirty patients with Tile C pelvic fractures treated by percutaneous minimally invasive pelvic reduction frame from April 2018 to April 2020 were retrospectively analyzed, including 21 males and 9 females, aged from 19 to 57 (39.40±9.85) years old. The patient's pelvic CT DICOM data were imported into Mimics software to reconstruct the virtual fracture model. Virtual reduction and nail placement were carried out on the fracture model, and then simulated fluoroscopy was carried out to record the ideal fluoroscopy orientation and angle to guide the correct fluoroscopy during operation. The operation time, fluoroscopy times and intraoperative blood loss were recorded. The quality of fracture reduction was evaluated by Matta image score standard, and the postoperative function was evaluated by Majeed function score standard.
RESULTS:
All 30 patients achieved closed reduction and percutaneous screw fixation. According to Matta score, the excellent and good rate of fracture reduction was 93.3%(28/30). A total of 67 channel screws were inserted, and the excellent and good rate was 98.5%(66/67). The operation time was (173.54±79.31) min, fluoroscopy time was (90.81±41.11) times, intraoperative blood loss was (81.21±43.97) ml. All incisions healed at one stage without broken nails or re-displacement of fractures. All patients were followed up for 12 months. At the final follow-up, Majeed function score was 73 to 94(85.66±5.33) scores.
CONCLUSION
Computer virtual technology combined with pelvic reduction frame could rapidly, accurately and safely reduce and fix unstable pelvic fractures. Computer virtualization could help surgeons to recognition and understanding pelvic fractures, pelvic reduction frame could improve the surgeon's ability to manage complex and unstable pelvic injuries.
Adult
;
Blood Loss, Surgical
;
Computers
;
Female
;
Fracture Fixation, Internal/methods*
;
Fractures, Bone/surgery*
;
Humans
;
Male
;
Middle Aged
;
Pelvic Bones/injuries*
;
Retrospective Studies
9.Design and Experimental Research of Portable Extracorporeal Circulation Pipeline Performance Testing System.
Song LIU ; Ganying WANG ; Yihan WANG ; Ling PENG ; Jinlu ZHENG
Chinese Journal of Medical Instrumentation 2022;46(2):164-167
Aiming at the current situation of performance testing of hemodialysis extracorporeal circulation tubing, which has slow efficiency, inaccurate measurement, and inconvenient testing, a portable detection system for testing the performance of hemodialysis extracorporeal circulation tubing is designed. The system mainly includes a hardware system and a software system. The hardware system uses STM32F407 single-chip microcomputer as the core to design the driving control of the roller pump; the software system uses the C++ real-time operating system, and the flow detection data is transmitted to the upper computer through RS485 communication and displayed. Experimental showed that the system detects the accuracy and the stability of the flow rate. It has the characteristics of stability and high precision. The relative error of the experimental measurement is within the range of ±10%. The weight of the whole machine is 2 kg, which improves the efficiency by 50% compared with the traditional detection method.
Computers
;
Equipment Design
;
Extracorporeal Circulation
;
Microcomputers
;
Renal Dialysis
;
Software
10.Computer-aided aptamers screening technologies: a review.
Bowen DENG ; Siyi GAO ; Boyi XIAO ; Yulong WU ; Hao SUN ; Lianghua WANG ; Mingjuan SUN
Chinese Journal of Biotechnology 2022;38(2):678-690
The computer information technology that has penetrated into every aspect of our lives, can not only assist the screening of drugs, but also simulate the effect of drugs. At present, computer-aided technologies have been used to screen aptamers, which play an important role in improving the screening efficiency and screening high affinity binding aptamers. This review summarized the screening methods of aptamers through computer-aided sequence evaluation, structural analysis and molecular docking.
Aptamers, Nucleotide
;
Computers
;
Molecular Docking Simulation
;
SELEX Aptamer Technique/methods*


Result Analysis
Print
Save
E-mail