1.Mid-term effectiveness of hip preservation in the reconstruction of ultrashort bone segments in the proximal femur with three-dimensional printed customized cementless intercalary endoprosthesis with an intra-neck curved stem.
Hongtao SHENG ; Yuqi ZHANG ; Qi YOU ; Taojun GONG ; Zhuangzhuang LI ; Xuanhong HE ; Fan TANG ; Yong ZHOU ; Yitian WANG ; Minxun LU ; Yi LUO ; Li MIN ; Chongqi TU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(8):970-977
OBJECTIVE:
To explore the design points of a three-dimensional (3D) printed customized cementless intercalary endoprosthesis with an intra-neck curved stem and to evaluate the key points and mid-term effectiveness of its application in the reconstruction of ultrashort bone segments in the proximal femur.
METHODS:
Between October 2015 and January 2021, 17 patients underwent reconstruction with a 3D printed-customized cementless intercalary endoprosthesis with an intra-neck curved stem. There were 11 males and 6 females, the age ranged from 10 to 76 years, with an average of 30.1 years. There were 9 cases of osteosarcoma, 4 cases of Ewing sarcoma, 2 cases of chondrosarcoma, 1 case of liposarcoma, and 1 case of myofibroblastoma. The disease duration was 5-14 months, with an average of 9.5 months. Enneking staging included 16 cases of stage ⅡB and 1 case of stage ⅢB. The distances from the center of the femoral head to the body midline and the acetabular apex were measured preoperatively on X-ray images. Additionally, the distances from the tip of the intra-neck curved stem to the body midline and the acetabular apex were measured at immediate postoperatively and last follow-up. The neck-shaft angle was also measured preoperatively, at immediate postoperatively, and at last follow-up. The status of osseointegration at the bone-prosthesis interface and bone growth into the prosthesis surface were assessed by X-ray films, CT, and Tomosynthesis-Shimadzu metal artefact reduction technology (T-SMART). The survival status of the patients, presence of local recurrence or distant metastasis, and occurrence of postoperative complications were assessed. The recovery of lower limb function was evaluated pre- and post-operatively using the Musculoskeletal Tumor Society (MSTS) scoring system, and pain relief was evaluated using the visual analogue scale (VAS) scores.
RESULTS:
The patient's femoral resection length was (163.1±57.5) mm, the remaining proximal femoral length was (69.6±9.3) mm, and the percentage of femoral resection length/total femoral length was 38.7%±14.6%. All 17 patients were followed up 25-86 months with an average of 58.1 months. During the follow-up, 1 patient died of lung metastasis at 46 months postoperatively, and the remaining 16 patients survived tumor-free. There was no complication such as periprosthetic infection, delayed incision healing, aseptic loosening, prosthesis fracture, or periprosthetic fracture. No evidence of micromotion or wear around the implanted stem of the prosthesis was detected in X-ray and T-SMART evaluations. There was no significant radiolucent lines, and radiographic evidence of bone ingrowth into the bone-prosthesis interface was observed in all stems. There was no significant difference in the distance from the tip of the curved stem to the body midline and the apex of the acetabulum at immediate postoperatively and last follow-up compared with the distance from the center of the femoral head to the body midline and the apex of the acetabulum before operation, respectively (P>0.05), and there was no significant difference in the above indexes between immediate postoperatively and last follow-up (P>0.05). The differences in the neck-shaft angle at various time points before and after operation were also not significant (P>0.05). At last follow-up, the MSTS score was 26.1±1.2 and the VAS score was 0.1±0.5, which were significantly improved when compared with those before operation [19.4±2.1 and 5.7±1.0, respectively] (t=14.735, P<0.001; t=21.301, P<0.001). At last follow-up, none of the patients walked with the aid of crutches or other walkers.
CONCLUSION
The 3D printed customized cementless intercalary endoprosthesis with an intra-neck curved stem is an effective method for reconstructing ultrashort bone segments in the proximal femur following malignant tumor resection. The operation is reliable, the postoperative lower limb function is satisfactory, and the incidence of complications is low.
Female
;
Male
;
Humans
;
Child
;
Adolescent
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Femur/surgery*
;
Lower Extremity
;
Bone-Implant Interface
;
Femur Head
;
Artificial Limbs
2.Three-dimensional-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
Xin LIU ; Yi LUO ; Xuanhong HE ; Jie WANG ; Zhuangzhuang LI ; Yuqi ZHANG ; Xin HU ; Minxun LU ; Fan TANG ; Yong ZHOU ; Li MIN ; Chongqi TU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1183-1189
OBJECTIVE:
To investigate the effectiveness of three-dimensional (3D)-printed hemi-pelvic prosthesis for revision of aseptic loosening or screw fracture of modular hemi-pelvic prosthesis.
METHODS:
Between February 2017 and January 2020, 11 patients with aseptic loosening or screw fracture of modular hemi-pelvic prosthesis were revised using 3D-printed hemi-pelvic prostheses. There were 7 males and 4 females with an average age of 44 years (range, 25-60 years). In the first operation, all patients underwent total tumor resection, modular hemi-pelvic prosthesis reconstruction, and autologous femoral head transplantation. According to the Enneking pelvic partition system, 8 cases were resected in zones Ⅰ+Ⅱ and 3 cases in zones Ⅰ+Ⅱ+Ⅲ. The interval from the initial operation to this revision ranged from 14.3-66.2 months, with an average of 35.8 months. The operation time, the amount of intraoperative bleeding, and the occurrence of complications were recorded. At 6 months after the first operation, before revision, and at last follow-up, the American Musculoskeletal Tumor Society (MSTS) score and Harris score were used to evaluate the recovery of lower limb function. The pain-free walking distance of patients without brace assistance was recorded at last follow-up. X-ray films were taken at 1 month after the first operation, before revision, and at 1 month after revision, the acetabulum position was assessed by the differences in weight arm and cup height between bilateral hip joints. At last follow-up, the digital X-ray tomography was taken to evaluate the prosthesis-bone integration and the occurrence of aseptic loosening.
RESULTS:
The operation time was 182.6-238.0 minutes (mean, 197.4 minutes). The amount of intraoperative bleeding was 400-860 mL (mean, 550.0 mL). All incisions healed by first intention with no infection, hip dislocation, nerve damage, or vascular-related adverse events. The MSTS score and Harris score at last follow-up were significantly higher than those at 6 months after the first operation and before revision ( P<0.05), while the score before revision was significantly lower than that at 6 months after the first operation ( P<0.05). At last follow-up, the patients were able to walk more than 1 000 meters painlessly without brace assistance. Imaging review showed that the difference of cup height at 1 month after revision was significantly lower than that at 1 month after the first operation and before revision, and at 1 month after the first operation than before revision operation, and the differences were significant ( P<0.05). There was no significant difference in the difference of weight arm among three time points ( P>0.05). All prostheses were well integrated, and no aseptic loosening of the prosthesis or screw fracture occurred.
CONCLUSION
Revision with 3D-printed hemi-pelvic prostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening or screw fracture of modular hemi-pelvic prosthesis. Early postoperative rehabilitation training can maximize the recovery of patient limb function, reduce pain during walking, and reduce the incidence of complications.
Male
;
Female
;
Humans
;
Adult
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Treatment Outcome
;
Prosthesis Failure
;
Fractures, Bone/surgery*
;
Retrospective Studies
;
Neoplasms
3.Long-term effectiveness of uncemented allograft-prosthesis composite for reconstruction of bone defects after proximal femur tumor resection.
Yang WANG ; Minxun LU ; Yuqi ZHANG ; Xuanhong HE ; Zhuangzhuang LI ; Taojun GONG ; Yitian WANG ; Yong ZHOU ; Yi LUO ; Fan TANG ; Wenli ZHANG ; Hong DUAN ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(10):1190-1197
OBJECTIVE:
To investigate the long-term effectiveness of uncemented allograft-prosthesis composite (APC) for reconstruction of bone defects after proximal femur tumor resection.
METHODS:
Between June 2007 and March 2014, 21 patients who underwent uncemented APC reconstruction of proximal femur after tumor resection were retrospectively evaluated. There were 9 males and 12 females with an average age of 33.2 years (range, 19-54 years). There were 9 cases of giant cell tumor of bone, 5 cases of osteosarcoma, 4 cases of osteoblastic osteosarcoma, 2 cases of chondrosarcoma, and 1 case of undifferentiated pleomorphic sarcoma. Thirteen cases of benign bone tumors were all classified as stage 3 by Enneking staging; and 8 cases of malignant bone tumors were classified as grade ⅡB in 7 cases and grade ⅡA in 1 case according to the American Joint Committee on Cancer (AJCC) staging system. Among them, 7 patients underwent reoperation after recurrence, and the rest were primary operations; 8 patients presented with pathological fractures. The preoperative Harris hip score (HHS) and American Musculoskeletal Tumor Society (MSTS) score was 40 (30, 49) and 9.1±3.5, respectively. The length of osteotomy was 80-154 mm, with an average of 110 mm. At 1 year after operation and last follow-up, HHS and MSTS scores were utilized to evaluate the function of hip joint; the gluteus medius strength score was used to evaluation of the hip abduction function. Image examinations were taken at 1, 3, 6, 9, and 12 months after operation and every year thereafter to assess the union of allograft-host bone interfaces. Intra- and post-operative complications were also recorded.
RESULTS:
All patients were followed up 84-163 months (mean, 123.5 months). At 1 year after operation and last follow-up, the HHS and MSTS scores significantly improved when compared with the preoperative scores ( P<0.05). However, there was no significant difference in the HHS score, MSTS score, and gluteus medius strength score between the two time points after operation ( P>0.05). Image examination showed that all allograft-host bone interfaces achieved union after 5-10 months (mean, 7.6 months). At last follow-up, all patients had bone resorption, including 11 severe cases, 4 moderate cases, and 6 mild cases; the bone resorption sites included Gruen 1, 2, and 7 regions. Complications included 10 fractures and 1 prosthetic fracture. Local recurrence occurred in 3 patients and pulmonary metastasis in 3 patients.
CONCLUSION
Uncemented APC is a reliable method for the reconstruction of bone defects after proximal femur tumor resection. It has the good long-term effectiveness and possesses obvious advantages in the union at the bone-bone surface.
Adult
;
Female
;
Humans
;
Male
;
Allografts/pathology*
;
Bone Neoplasms/surgery*
;
Bone Resorption/pathology*
;
Bone Transplantation/methods*
;
Femur/surgery*
;
Osteosarcoma/pathology*
;
Prostheses and Implants
;
Retrospective Studies
;
Treatment Outcome
;
Young Adult
;
Middle Aged
4.Short-term outcomes of reconstruction of tumorous critical bone defects at femoral shaft with a 3D printed ultra-short stem with a porous structure
Guifeng DU ; Jie WANG ; Xin HU ; Yang WEN ; Linyun TAN ; Minxun LU ; Yuqi ZHANG ; Yong ZHOU ; Yi LUO ; Li MIN ; Chongqi TU
Chinese Journal of Orthopaedic Trauma 2022;24(9):805-811
Objective:To explore the short-term outcomes of reconstruction of tumorous critical bone defects at femoral shaft with a 3D printed ultra-short stem with a porous structure.Methods:From September 2016 to June 2018, 8 patients underwent reconstruction of critical bone defects with a 3D printed ultra-short stem with a porous structure after resection of femoral shaft malignant tumor at Department of Orthopaedics, West China Hospital. There were 4 males and 4 females, with an average age of 36.9 years (from 11 to 61 years). Their preoperative Enneking staging was stage Ⅱb in all. There were 3 osteosarcomas, 2 Ewing sarcomas, 2 chondrosarcomas and one periosteal osteosarcoma. Preoperative CT/MRI image fusion technology was used to define the surgical boundary, design the guide plate and prosthesis, and perform surgical simulation. Tomosynthesis-shimadzu Metal Artefact Reduction technology was used to evaluate osseointegration. Complications and bone oncology prognosis of the patients were documented. The lower limb function of the patients was evaluated using Musculoskeletal Tumor Society (MSTS) 1993 scoring and knee range of motion.Results:The overall follow-up time ranged from 36 to 50 months, averaging 42.8 months. During operation one patient sustained a periprosthesis fracture, the union of which was followed up after wire assisted fixation. There was no local tumor recurrence, lung metastasis or death. The last follow-up revealed good osseointegration and basically isometric lower extremities in all cases. There was no such a complication as aseptic loosening of the prosthesis, deep infection or prosthesis fracture during the follow-up period. At the last follow-up in the 8 patients, the flexion range of the knee joint was 116.2°±9.1°, significantly improved compared with that before operation (98.8°±10.9°), and the MSTS score was (26.2±2.1) points, also significantly improved compared with that before operation [(21.6±1.8) points] ( P<0.05). Conclusions:Reconstruction with a 3D printed ultra-short stem with a porous structure is an accurate operation for femoral shaft tumorous bone defects. With careful preoperative design, intraoperative manipulation and strict postoperative follow-up management, this operation can lead to fine early curative outcomes for long shaft critical bone defects.
5.Replacement with 3D-printed custom-made hemipelvic prosthesis for primary malignancy involving the pubis
Xin HU ; Pengcheng LI ; Yuqi ZHANG ; Li MIN ; Minxun LU ; Jie WANG ; Yitian WANG ; Yong ZHOU ; Yi LUO ; Hong DUAN ; Chongqi TU
Chinese Journal of Orthopaedic Trauma 2020;22(10):848-854
Objective:To observe the short-term efficacy of 3D-printed custom-made hemipelvic prosthesis in the treatment of primary malignant bone tumors of the pubis.Methods:From June 2017 to May 2019, a total of 5 patients with pubic primary malignant tumor received type Ⅲ hemipelvectomy and reconstruction with a 3D-printed custom-made hemipelvic prosthesis at Department of Orthopedics, West China Hospital. They were 3 males and 2 females with an average age of 36.3 years (range, from 26 to 46 years). Of them, 3 underwent resection of the upper pubic ramus and 2 resection of both pubic rami. All their tumors were chondrosarcomas, with one case of Enneking stage Ⅱa and 4 cases of Enneking stage Ⅱb. Preoperative CT/MRI image fusion was used to determine the tumor-free resection margin, design guide templates for osteotomy and prosthesis, and simulate surgical procedures. A total of 5 3D-printed custom-made hemipelvic prostheses were designed, including 3 ones with an intramedullary stem to preserve partial pubis and 2 ones with a non-intramedullary stem not to preserve the pubis. The functional recovery was assessed by Musculoskeletal Tumor Society (MSTS) scores. The prosthetic position and osseointegration were evaluated by imaging examination. Oncological outcomes and complications were recorded.Results:R0 resection and precise reconstruction were accomplished in all patients. Their intraoperative blood loss ranged from 300 to 3, 700 mL (mean, 1, 680 mL), operation time from 180 to 430 min (mean, 294 min), and follow-up time from 13 to 29 months (mean, 20.6 months). All the 5 patients were alive with no evidence of disease or tumor recurrence. The functional MSTS scores at the final follow-up ranged from 29 to 31 (mean, 29.8). One male patient complained of erectile dysfunction. Fretting wear around the prosthetic stem was found in 3 patients while bone wear on the normal pubic side in 2. Osseointegration was observed in all patients with no complications like deep infection, prosthesis dislocation, prosthetic or screw breakage.Conclusion:Since 3D-printed custom-made hemipelvic prostheses can result in fine short-term efficacy for pubic primary malignant bone tumors, they may be a reliable method to reconstruct pelvic malignant tumors.
6.Effect of occupational factors on pre-diabetes mellitus among iron and steel workers
Yajing LIAO ; Chuxuan XU ; Chongqi MA ; Zhenwei QIN ; Yajiao SU ; Hongru ZHU ; Xiaotong ZHANG ; Chan LI ; Xiaoming LI ; Zhaoyang WANG ; Juxiang YUAN ; Hongmin FAN
Chinese Journal of Epidemiology 2020;41(6):929-933
Objective:To investigate the prevalence of pre-diabetes mellitus (PDM) and the impact of occupation-related factors on PDM, among workers from a steel company in Tangshan city, Hebei province.Methods:Clustering sampling method was used to select a steel company and to carry out occupational health-related physical checkup programs for eligible workers who had working in this company for longer than one year. The study began in February and ended up in June, 2017. Workers who were with FPG level as ≤6.9 mmol/L, and free from diabetes, were selected as the subjects for this study. Questionnaires were used and physical examinations and FPG testing conducted.Results:The total number of subjects in this study was 4 173, of which 2 648 appeared as pre-diabetic, with the prevalence rate as 63.4 %. Increase of the PDM prevalence was in parallel with the length of service, among the workers. The risk for the pre-diabetes in those who worked more than 8 hours per day was 1.696 times higher than those who worked less than or equal to 8 h/d (95 %CI:1.517-1.937). Compared with those workers without exposures to heat, noise or carbon monoxides, the proportion of pre-diabetes appeared higher in workers exposed to heat, noise or CO with OR=1.782 (95 %CI: 1.205-2.636), 1.815 (95 %CI: 1.209-2.794) and 1.653 (95 %CI: 1.158-2.361), respectively. Risks for those who were exposed to heat or noise were higher than those who were free from exposure to any occupational hazards ( OR=2.098, 95 %CI: 1.296-3.397). Prevalence rates of pre-diabetes in those who were exposed to heat, noise or CO, were higher than that those who were not. Conclusion:Working hours and exposures to heat, noise or CO appeared as influential factors on PDM.
7. Effect of cumulated noise exposure on the intima-media thickness of carotid artery in steel workers
Chongqi MA ; Yajing LIAO ; Shengkui ZHANG ; Yajiao SU ; Haitao WANG ; Hongmin FAN
China Occupational Medicine 2019;46(01):50-60
OBJECTIVE: To explore the effects of cumulative noise exposure(CNE) on the intima-media thickness(IMT) of carotid artery in steel workers. METHODS: A cluster random sampling method was used to select 1 437 noise exposed workers in a steel company as study subjects. The CNE was calculated according to the noise intensity of the workplace, and the occupational health check was carried out to construct the structural equation model of noise to IMT. RESULTS: The detection rate of carotid atherosclerosis(CAS) in these 1 437 subjects was 38.3%. The CAS detection rates of steel workers increased with the increasing CNE(P<0.01). The structural equation model had good fitting effect. Path analysis showed CNE can indirectly affect IMT through blood pressure, triglycerides, fasting blood glucose, homocysteine, high-density lipoprotein & apolipoprotein A, low-density lipoprotein & apolipoprotein B. The total effects were-0.375, 0.337, 0.248, 0.117, 0.056, 0.056 and 0.018 respectively. CONCLUSION: CNE can indirectly increase the IMT of steel workers by acting on the proximal cause.
8. Effect of occupational high temperature exposure on type 2 diabetes in male steel workers
Yajing LIAO ; Chongqi MA ; Zhenwei QIN ; Yajiao SU ; Chaoyang WANG ; Xiaoming LI ; Bo HU ; Yinping CHEN ; Juxiang YUAN ; Hongmin FAN
China Occupational Medicine 2019;46(03):307-311
OBJECTIVE: To explore the effect of occupational high temperature exposure on type 2 diabetes( T2 DM) in male steel workers. METHODS: A cluster random sampling method was used to select 684 male steel workers,who exposed to occupational high temperature in a steel enterprise in Tangshan City,as the high temperature group,and 1 153 male steel workers without occupational high temperature exposure as the control group. The high temperature level of workers in these two groups was measured. The cumulative exposure( CE) of high temperature was calculated,and occupational health exam was performed. The multivariate logistic regression analysis and restricted cubic splines were used to analyze the relationship between high temperature CE and T2 DM. RESULTS: The prevalence of T2 DM in high-temperature group was higher than that in the control group( 13. 0% vs 7. 9%,P < 0. 05). The multivariate logistic regression analysis results showed that the risk of T2 DM in the high temperature group was higher than that in the control group after adjusting for age,body mass index,smoking,drinking,physical exercise and parents with diabetes( P < 0. 05). The 95% confidence interval was 1. 65( 1. 17-2. 33). Restricted cubic spline analysis showed that the high temperature CE was correlated with the prevalence of T2 DM in workers( P < 0. 01) and showed a linear correlation( nonlinearity test,P > 0. 05). CONCLUSION: Occupational high temperature exposure is associated with the occurrence of T2 DM in male steel workers. The male steel workers with high temperature CE show high prevalence of T2 DM risk.
9. Impact and mechanism of low intensity ultrasound on bone marrow suppression induced by docetaxel in rats
Chinese Journal of Interventional Imaging and Therapy 2019;16(8):485-490
Objective: To analyze the effect and mechanism of low intensity ultrasound on bone marrow suppression induced by docetaxel in rat models. Methods: Forty female rats were randomly divided into ultrasound group and control group (each n=20). Daily intraperitoneal injection of docetaxel (25 mg/kg) was given all rats for consecutive 4 days. Rats in ultrasound group were daily irradiated with low intensity ultrasound for consecutive 7 days after the first injection of docetaxel, while rats in control group received false irradiation at the same time. Routine blood examination and immunoglobulin tests were performed before docetaxel injection on the 4th, 7th and 14th day of irradiation. On the 4th day of irradiation, 4 rats in each group were randomly selected and killed for detection of stem cell factor (SCF), intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1). Histological methods were used to detect the number of nucleated cells in the right femoral bone marrow tissue of rats before injection of docetaxel on the 4th, 7th and 14th day after the first time of irradiation. HE staining and pathological examinations of skin and muscle tissues of rats were performed on the 7th day after the first time of irradiation. Results: In ultrasound group, leukocyte, neutrophil and lymphocyte counts in peripheral blood on the 4th day after the first time of irradiatio, titer of immunoglobulin A (IgA) on the 7th and 14th day after the first time of irradiation, titers of immunoglobulin G (IgG) and immunoglobulin M (IgM) on the 4th and 14th day after the first time of irradiation increased obviously compared with those of control group (all P<0.05). The relative mRNA expression levels of SCF and ICAM-1 in bone marrow of rats in ultrasound group were significantly higher than those in control group, while the relative mRNA expression level of VCAM-1 in bone marrow of rats in ultrasound group was significantly lower than that in control group (all P<0.05). On the 4th and 7th day after the first time of irradiation, the numbers of bone marrow nucleated cells in ultrasound group were significantly higher than those in control group (both P<0.05). There was no obvious damage to the skin and muscle of the irradiated rats in both the two groups. Conclusion: Low intensity ultrasound is feasible in treatment of bone marrow suppression induced by docetaxel in rats, and its mechanism may be improvement of bone marrow hematopoietic microenvironment.
10. Effects of occupational stress on total cholesterol and triglyceride among male steel workers
Longxue CONG ; Xuejuan GAO ; Yao LU ; Hongmin FAN ; Chongqi MA ; Yajing LIAO ; Chaoyang WANG ; Mengying XIAO ; Chongliang CHE ; Juxiang YUAN ; Bo HU ; Xiaoming LI
China Occupational Medicine 2018;45(02):183-187
OBJECTIVE: To analyze the effect of occupational stress on abnormity of serum total cholesterol and triglyceride in male steel workers. METHODS: A total of 3 957 male steel workers from an iron and steel group company were selected as study objects by judgment sampling method. Occupational stress was measured by the Chinese version of Job Content Questionnaire. The serum total cholesterol and triglyceride levels were measured using fasting venous blood. RESULTS: Among the 3 957 workers,the detection rate of occupational stress was 56. 8%,and 55. 0% of them showed high social support. The abnormal rates of total cholesterol and triglyceride were 21. 8% and 40. 9%,respectively. The multivariate logistic regression analysis showed that workers with high social support had high risk of abnormal total cholesterol and abnormal triglyceride than workers with low social support( P < 0. 05) after adjusting for confounding factors such as age,education level,marital status,body mass index,smoking and drinking alcohol,tea. The odds ratio of abnormal total cholesterol in occupational stress workers was 1. 17 times of that of non-occupational stress workers. No association was found between occupational stress and abnormal triglyceride( P > 0. 05). CONCLUSION: Occupational stress may be associated with abnormity of total cholesterol in male steel workers. Social support is an important influences factor to the abnormity of total cholesterol and triglyceride in male steel workers.

Result Analysis
Print
Save
E-mail