1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Diagnostic value of ultrasonography and CT in acute appendicitis
Kai LU ; Chong SUN ; Juan MIAO ; Kaibo ZHOU ; Wei WANG ; Hua YANG ; Yong CHENG
Journal of Practical Radiology 2024;40(4):586-589
Objective To compare the diagnostic value of ultrasonography and CT in acute appendicitis.Methods A retrospective analysis was conducted on 279 patients who were diagnosed with acute appendicitis and followed emergency surgery.Patients were divided into different subgroups based on postoperative pathological results and body mass index(BMI),and the pathological results were used as the gold standard to analyze whether there were differences in the diagnostic accuracy of ultrasonography and CT examination for acute appendicitis.Results A total of 279 patients with confirmed acute appendicitis,with 64 cases of simple appendicitis,127 cases of suppurative appendicitis,and 88 cases of gangrenous appendicitis according to pathological classification.The diagnostic accuracy of ultrasonography was 68.75%(44/64),73.22%(93/127),and 81.81%(72/88),respectively.The diagnostic accuracy of CT was 71.87%(46/64),82.67%(105/127),and 90.90%(80/88),respectively.There was no statistically significant difference in diagnostic accuracy between the two examinations(P>0.05).Subgroup analysis based on patient BMI showed that there was no difference in diagnostic accuracy of the two examinations for patients with normal BMI(P>0.05),while for overweight and obese patients,the diagnostic accuracy of CT was better than that of ultrasonography,with a statistical difference(P<0.05).Conclusion There is no difference in the diagnostic accuracy of ultrasonography and CT examinations for acute appendicitis of different pathological types.But for overweight and obese acute appendicitis patients,the diagnostic accuracy of CT examination is superior to ultrasonography.
7.Expression of miR-205 and miR-367 in cutaneous malignant melanoma tissue and their clinical significances
Li-Jun ZHANG ; Wei-Heng YAN ; Guo-Qing HUANG ; Chong-Zhou SUN
Journal of Regional Anatomy and Operative Surgery 2024;33(1):84-88
Objective To study the expression of miR-205 and miR-367 in cutaneous malignant melanoma(CMM)tissue and their relationships with clinicopathological characteristics and prognosis.Methods The tumor tissues from 85 patients with CMM who were admitted to our hospital from May 2013 to December 2019 were selected as the CMM group,and the nevus tissue samples from 80 patients with benign pigmented nevi who were treated in our hospital during the same period were selected as the control group.The expression level of miR-205 and miR-367 of two groups were detected by qRT-PCR.The clinical and pathological data of patients with CMM were collected,and the relationships between the expression of miR-205 and miR-367 and clinicopathological characteristics were analyzed.Kaplan-Meier was used to draw the survival curves of patients 3 years after surgery,and the survival rate of patients was analyzed by Log-rank test.The influencing factors of prognosis was analyzed by COX proportional risk regression model.Results The expression level of miR-205 of patients in the CMM group was lower than that in the control group,and the expression level of miR-367 was higher than that in the control group(P<0.05).The proportions of patients with ulceration,high clinical stage,tumor invasion,low KPS score,thick primary lesion,high Clark grade,lymph node metastasis in the miR-205 low-expression group were higher than those in the miR-205 high-expression group(P<0.05),the proportions of patients with the above indexes in the miR-367 high-expression group were higher than those in the miR-367 low-expression group(P<0.05).Patietns were followed up for 3 years,with a median time of 28.3 months,and 1 case was lost to followed-up.The Kaplan-Meier survival curve showed that the 3-year survival rate of patients in the miR-205 high-expression group was higher than that in the miR-205 low-expression group(P<0.05),and the 3-year survival rate of patients in the miR-367 low-expression group was higher than that in the miR-367 high-expression group(P<0.05).COX multivariate regression analysis showed that the high clinical stage,low KPS score,high Clark grade,lymph node metastasis,and high expression of miR-367 were the risk factors for prognosis of patients,while high expression of miR-205 was a protective factor(P<0.05).Conclusion Low expression of miR-205 and high expression of miR-367 in CMM tissue are associated with ulceration,high clinical stage,tumor invasion,low KPS score,thick primary lesion,high Clark grade,lymph node metastasis,and poor prognosis.These two indicators may serve as potential biomarkers for prognostic evaluation in CMM patients.
8.Associations of onset age, diabetes duration and glycated hemoglobin level with ischemic stroke risk in type 2 diabetes patients: a prospective cohort study
Xikang FAN ; Mengyao LI ; Yu QIN ; Chong SHEN ; Yan LU ; Zhongming SUN ; Jie YANG ; Ran TAO ; Jinyi ZHOU ; Dong HANG ; Jian SU
Chinese Journal of Epidemiology 2024;45(4):498-505
Objective:To investigate the associations of onset age, diabetes duration, and glycated hemoglobin (HbA1c) levels with ischemic stroke risk in type 2 diabetes patients.Methods:The participants were from Comprehensive Research on the Prevention and Control of the Diabetes in Jiangsu Province. The study used data from baseline survey from December 2013 to January 2014 and follow-up until December 31, 2021. After excluding the participants who had been diagnosed with stroke at baseline survey and those with incomplete information on onset age, diabetes duration, and HbA1c level, a total of 17 576 type 2 diabetes patients were included. Cox proportional hazard model was used to calculate the hazard ratio ( HR) and 95% CI of onset age, diabetes duration, and HbA1c level for ischemic stroke. Results:During the median follow-up time of 8.02 years, 2 622 ischemic stroke cases were registered. Multivariate Cox proportional risk regression model showed that a 5-year increase in type 2 diabetes onset age was significantly associated with a 5% decreased risk for ischemic stroke ( HR=0.95, 95% CI: 0.92-0.99). A 5-year increase in diabetes duration was associated with a 5% increased risk for ischemic stroke ( HR=1.05, 95% CI: 1.02-1.10). Higher HbA1c (per 1 standard deviation increase: HR=1.17, 95% CI: 1.13-1.21) was associated with an increased risk for ischemic stroke. Conclusion:The earlier onset age of diabetes, longer diabetes duration, and high levels of HbA1c are associated with an increased risk for ischemic stroke in type 2 diabetes patients.
9.Association of serum gamma-glutamyl transferase levels with cardiovascular disease risk in type 2 diabetes patients: a prospective cohort study
Mian WANG ; Xikang FAN ; Jian SU ; Yu QIN ; Chong SHEN ; Yan LU ; Zhongming SUN ; Jie YANG ; Ran TAO ; Jinyi ZHOU ; Ming WU
Chinese Journal of Epidemiology 2024;45(10):1339-1347
To investigate the associations of serum gamma-glutamyl transferase (GGT) levels with the risk of cardiovascular disease (CVD) and its subtypes in patients with type 2 diabetes mellitus (T2DM) in Jiangsu Province.Methods:The participants were enrolled in the Comprehensive Research project regarding 'Prevention and Control of Diabetes' in Jiangsu Province. The baseline survey was conducted from 2013 to 2014, and follow-up until December 31, 2021. After excluding the participants who self-reported with chronic liver disease/stroke/coronary heart disease at baseline survey and those with incomplete information on GGT, a total of 16 147 T2DM patients were included in the final analysis. Cox proportional hazard regression models were used to calculate the hazard ratio ( HR) and their 95% CI of GGT for CVD, myocardial infarction, and stroke. Restricted cubic spline models were applied to analyze the dose-response relationship between GGT and the risk of CVD and its subtypes. Results:During the median follow-up time of 8.02 years, 2 860 CVD cases were registered, including 196 cases of myocardial infarction and 2 730 cases of stroke. Multivariate Cox proportional risk regression model indicated that compared to the lowest serum GGT level group, the highest GGT level group had a 24% increased risk of CVD ( HR=1.24, 95% CI: 1.09-1.41) and a 23% increased risk of stroke ( HR=1.23, 95% CI: 1.08-1.40). The restricted cubic spline model showed a nonlinear dose-response relationship between GGT and the risk of CVD, myocardial infarction, and stroke in T2DM patients. Conclusions:High levels of GGT may be associated with an increased risk of cardiovascular disease in T2DM patients, which needs further exploration and validation in future clinical practice.
10.Ferroptosis: new opportunities for radiosensitization
Ziqiang SHEN ; Yichu SUN ; Fei LIANG ; Jing YANG ; Chong ZHOU ; Youyou XIA
Chinese Journal of Radiation Oncology 2024;33(9):864-869
Ferroptosis is a novel form of cell death discovered in recent years, characterized by iron-dependent cell death featuring the peroxidation of polyunsaturated fatty acid phospholipids. Recent studies have found that radiotherapy can induce ferroptosis in tumor cells through ionizing radiation, and the combination of radiotherapy with small molecule or nano-scale ferroptosis inducers can inhibit tumor growth and enhance radiosensitization. This review summarizes the mechanisms of ferroptosis and the pathways through which radiotherapy induces ferroptosis, and also explores the potential application prospects of small molecule drugs and nanomaterials in mediating ferroptosis for the radiosensitization of tumor treatment.

Result Analysis
Print
Save
E-mail