1.Effects of air pressure, humidity, wind and sunshine on the incidence of cardiovascular and cerebrovascular diseases in Guiyang
Zhengjing DU ; Yuanyuan SHANG ; Chong QU ; Qiang WANG ; Jie ZHOU
Journal of Public Health and Preventive Medicine 2025;36(1):32-36
Objective To explore the effects of air pressure, humidity, wind, and sunshine on the incidence of cardiovascular and cerebrovascular diseases (CVD) in Guiyang, and to provide reference for the prevention of CVD. Methods Using CVD incidence data from September 2021 to August 2022 in Guiyang City and meteorological data including average air pressure, average humidity, wind, and sunshine during the same period, the effects of meteorological factors on CVD incidence were explored and the importance of each factor was analyzed. Results When air pressure was below 868 hPa, above 887 hPa, or between 877 and 883 hPa, and when air pressure dropped less than 5.3 hPa within 24 hours, there was a higher risk of CVD. When the humidity was above 81%, the wind speed was small (<1.2 m/s) or high (>4m/s), and there was less sunlight (less than 3 hours), the risk of CVD was higher. Low humidity (<60%) was not conducive to the onset of CVD. There were highest risks at lag 5~10 days and 4-25 days for high pressure and low sunlight, respectively. When the relative humidity was saturated, there was an immediate effect. When the wind speed was low and high, the immediate effect and hysteresis effects were significant. Among the above meteorological factors, the impact of 24-hour variation of pressure and high or low atmospheric pressure on the incidence of CVD was the most significant, while the impact of sunlight and humidity was the weakest. The impact of diurnal variations in wind and atmospheric pressure was not clear. Conclusion The impact of air pressure on the incidence of CVD does not exhibit a simple linear relationship. The risk of CVD is high in high humidity, low light, and moderate or strong winds. It is necessary to fully consider changes in meteorological factors for CVD prevention and control.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Diagnostic value of ultrasonography and CT in acute appendicitis
Kai LU ; Chong SUN ; Juan MIAO ; Kaibo ZHOU ; Wei WANG ; Hua YANG ; Yong CHENG
Journal of Practical Radiology 2024;40(4):586-589
Objective To compare the diagnostic value of ultrasonography and CT in acute appendicitis.Methods A retrospective analysis was conducted on 279 patients who were diagnosed with acute appendicitis and followed emergency surgery.Patients were divided into different subgroups based on postoperative pathological results and body mass index(BMI),and the pathological results were used as the gold standard to analyze whether there were differences in the diagnostic accuracy of ultrasonography and CT examination for acute appendicitis.Results A total of 279 patients with confirmed acute appendicitis,with 64 cases of simple appendicitis,127 cases of suppurative appendicitis,and 88 cases of gangrenous appendicitis according to pathological classification.The diagnostic accuracy of ultrasonography was 68.75%(44/64),73.22%(93/127),and 81.81%(72/88),respectively.The diagnostic accuracy of CT was 71.87%(46/64),82.67%(105/127),and 90.90%(80/88),respectively.There was no statistically significant difference in diagnostic accuracy between the two examinations(P>0.05).Subgroup analysis based on patient BMI showed that there was no difference in diagnostic accuracy of the two examinations for patients with normal BMI(P>0.05),while for overweight and obese patients,the diagnostic accuracy of CT was better than that of ultrasonography,with a statistical difference(P<0.05).Conclusion There is no difference in the diagnostic accuracy of ultrasonography and CT examinations for acute appendicitis of different pathological types.But for overweight and obese acute appendicitis patients,the diagnostic accuracy of CT examination is superior to ultrasonography.
8.Associations of onset age, diabetes duration and glycated hemoglobin level with ischemic stroke risk in type 2 diabetes patients: a prospective cohort study
Xikang FAN ; Mengyao LI ; Yu QIN ; Chong SHEN ; Yan LU ; Zhongming SUN ; Jie YANG ; Ran TAO ; Jinyi ZHOU ; Dong HANG ; Jian SU
Chinese Journal of Epidemiology 2024;45(4):498-505
Objective:To investigate the associations of onset age, diabetes duration, and glycated hemoglobin (HbA1c) levels with ischemic stroke risk in type 2 diabetes patients.Methods:The participants were from Comprehensive Research on the Prevention and Control of the Diabetes in Jiangsu Province. The study used data from baseline survey from December 2013 to January 2014 and follow-up until December 31, 2021. After excluding the participants who had been diagnosed with stroke at baseline survey and those with incomplete information on onset age, diabetes duration, and HbA1c level, a total of 17 576 type 2 diabetes patients were included. Cox proportional hazard model was used to calculate the hazard ratio ( HR) and 95% CI of onset age, diabetes duration, and HbA1c level for ischemic stroke. Results:During the median follow-up time of 8.02 years, 2 622 ischemic stroke cases were registered. Multivariate Cox proportional risk regression model showed that a 5-year increase in type 2 diabetes onset age was significantly associated with a 5% decreased risk for ischemic stroke ( HR=0.95, 95% CI: 0.92-0.99). A 5-year increase in diabetes duration was associated with a 5% increased risk for ischemic stroke ( HR=1.05, 95% CI: 1.02-1.10). Higher HbA1c (per 1 standard deviation increase: HR=1.17, 95% CI: 1.13-1.21) was associated with an increased risk for ischemic stroke. Conclusion:The earlier onset age of diabetes, longer diabetes duration, and high levels of HbA1c are associated with an increased risk for ischemic stroke in type 2 diabetes patients.
9.Association of serum gamma-glutamyl transferase levels with cardiovascular disease risk in type 2 diabetes patients: a prospective cohort study
Mian WANG ; Xikang FAN ; Jian SU ; Yu QIN ; Chong SHEN ; Yan LU ; Zhongming SUN ; Jie YANG ; Ran TAO ; Jinyi ZHOU ; Ming WU
Chinese Journal of Epidemiology 2024;45(10):1339-1347
To investigate the associations of serum gamma-glutamyl transferase (GGT) levels with the risk of cardiovascular disease (CVD) and its subtypes in patients with type 2 diabetes mellitus (T2DM) in Jiangsu Province.Methods:The participants were enrolled in the Comprehensive Research project regarding 'Prevention and Control of Diabetes' in Jiangsu Province. The baseline survey was conducted from 2013 to 2014, and follow-up until December 31, 2021. After excluding the participants who self-reported with chronic liver disease/stroke/coronary heart disease at baseline survey and those with incomplete information on GGT, a total of 16 147 T2DM patients were included in the final analysis. Cox proportional hazard regression models were used to calculate the hazard ratio ( HR) and their 95% CI of GGT for CVD, myocardial infarction, and stroke. Restricted cubic spline models were applied to analyze the dose-response relationship between GGT and the risk of CVD and its subtypes. Results:During the median follow-up time of 8.02 years, 2 860 CVD cases were registered, including 196 cases of myocardial infarction and 2 730 cases of stroke. Multivariate Cox proportional risk regression model indicated that compared to the lowest serum GGT level group, the highest GGT level group had a 24% increased risk of CVD ( HR=1.24, 95% CI: 1.09-1.41) and a 23% increased risk of stroke ( HR=1.23, 95% CI: 1.08-1.40). The restricted cubic spline model showed a nonlinear dose-response relationship between GGT and the risk of CVD, myocardial infarction, and stroke in T2DM patients. Conclusions:High levels of GGT may be associated with an increased risk of cardiovascular disease in T2DM patients, which needs further exploration and validation in future clinical practice.
10.The 504th case: Multiple lymph node enlargement, renal insufficiency, blindness, and white matter lesions of the brain
Chong WEI ; Zhe ZHUANG ; Yunlong LI ; Xiaoxiao SHI ; Yubing WEN ; Wei CAO ; Siyuan FAN ; Xiao ZHANG ; Yan ZHANG ; Wei ZHANG ; Daobin ZHOU
Chinese Journal of Internal Medicine 2024;63(3):316-320
A 65-year-old male patient was admitted for recurrent lymph node enlargement for 5 years and elevated creatinine for 6 months. This patient was diagnosed with angioimmunoblastic T-cell lymphoma 5 years ago and underwent multiple lines of anti-tumor therapy, including cytotoxic chemotherapy; epigenetic modifying drugs such as chidamide and azacitidine; the immunomodulator lenalidomide; and targeted therapy such as rituximab, a CD20-targeting antibody, and brentuximab vedotin, which targets CD30. Although the tumor was considered stable, multiple virus activation (including BK virus, JC virus, and cytomegalovirus) accompanied by the corresponding organ damage (polyomavirus nephropathy, cytomegalovirus retinitis, and progressive multifocal leukoencephalopathy) occurred during anti-tumor treatment. Anti-tumor therapy was suspended and ganciclovir was used. The serum viral load decreased and organ functions were stabilized. The purpose of this report was to raise clinicians′ awareness of opportunistic virus reactivation during anti-tumor treatment.


Result Analysis
Print
Save
E-mail