1.Effects of air pressure, humidity, wind and sunshine on the incidence of cardiovascular and cerebrovascular diseases in Guiyang
Zhengjing DU ; Yuanyuan SHANG ; Chong QU ; Qiang WANG ; Jie ZHOU
Journal of Public Health and Preventive Medicine 2025;36(1):32-36
Objective To explore the effects of air pressure, humidity, wind, and sunshine on the incidence of cardiovascular and cerebrovascular diseases (CVD) in Guiyang, and to provide reference for the prevention of CVD. Methods Using CVD incidence data from September 2021 to August 2022 in Guiyang City and meteorological data including average air pressure, average humidity, wind, and sunshine during the same period, the effects of meteorological factors on CVD incidence were explored and the importance of each factor was analyzed. Results When air pressure was below 868 hPa, above 887 hPa, or between 877 and 883 hPa, and when air pressure dropped less than 5.3 hPa within 24 hours, there was a higher risk of CVD. When the humidity was above 81%, the wind speed was small (<1.2 m/s) or high (>4m/s), and there was less sunlight (less than 3 hours), the risk of CVD was higher. Low humidity (<60%) was not conducive to the onset of CVD. There were highest risks at lag 5~10 days and 4-25 days for high pressure and low sunlight, respectively. When the relative humidity was saturated, there was an immediate effect. When the wind speed was low and high, the immediate effect and hysteresis effects were significant. Among the above meteorological factors, the impact of 24-hour variation of pressure and high or low atmospheric pressure on the incidence of CVD was the most significant, while the impact of sunlight and humidity was the weakest. The impact of diurnal variations in wind and atmospheric pressure was not clear. Conclusion The impact of air pressure on the incidence of CVD does not exhibit a simple linear relationship. The risk of CVD is high in high humidity, low light, and moderate or strong winds. It is necessary to fully consider changes in meteorological factors for CVD prevention and control.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Diagnostic value of ultrasonography and CT in acute appendicitis
Kai LU ; Chong SUN ; Juan MIAO ; Kaibo ZHOU ; Wei WANG ; Hua YANG ; Yong CHENG
Journal of Practical Radiology 2024;40(4):586-589
Objective To compare the diagnostic value of ultrasonography and CT in acute appendicitis.Methods A retrospective analysis was conducted on 279 patients who were diagnosed with acute appendicitis and followed emergency surgery.Patients were divided into different subgroups based on postoperative pathological results and body mass index(BMI),and the pathological results were used as the gold standard to analyze whether there were differences in the diagnostic accuracy of ultrasonography and CT examination for acute appendicitis.Results A total of 279 patients with confirmed acute appendicitis,with 64 cases of simple appendicitis,127 cases of suppurative appendicitis,and 88 cases of gangrenous appendicitis according to pathological classification.The diagnostic accuracy of ultrasonography was 68.75%(44/64),73.22%(93/127),and 81.81%(72/88),respectively.The diagnostic accuracy of CT was 71.87%(46/64),82.67%(105/127),and 90.90%(80/88),respectively.There was no statistically significant difference in diagnostic accuracy between the two examinations(P>0.05).Subgroup analysis based on patient BMI showed that there was no difference in diagnostic accuracy of the two examinations for patients with normal BMI(P>0.05),while for overweight and obese patients,the diagnostic accuracy of CT was better than that of ultrasonography,with a statistical difference(P<0.05).Conclusion There is no difference in the diagnostic accuracy of ultrasonography and CT examinations for acute appendicitis of different pathological types.But for overweight and obese acute appendicitis patients,the diagnostic accuracy of CT examination is superior to ultrasonography.
8.Construction and gene identification of myeloid-specific Spi1 knockout mice
Xuming WU ; Huihui WANG ; Xiangling ZHU ; Yuanyuan ZHOU ; Anqi WANG ; Huiru ZHANG ; Chong LIU ; Jiajie TU
Acta Universitatis Medicinalis Anhui 2024;59(3):413-417
Objective To construct myeloid-specific Spi1 gene knockout mice and analyze their genotypes,so as to provide animal model basis for the study of pathological mechanism of diseases and drug targets.Methods Ac-cording to the principle of CRISPR/Cas9 technology and Cre/LoxP system,sgRNA and Donor vectors were de-signed and constructed.The transcript of Exon 2(Exon 2)was used as the knockout region,and Loxp elements were placed on both sides of Exon 2.Cas9 protein,sgRNA and Donor vector were mixed and microinjected into the fertilized eggs of C57BL/6J mice,the fertilized eggs were transplanted into the uterus of C57BL/6J pregnant female mice,and F0 generation was obtained after 19~20 days.Positive F0 mice were mated with C57BL/6J mice to ob-tain stable F1 Spi1flox/+mice.Spi1flox/+mice of F1 generation were selfed to obtain Spi1flox/flox mice.Spi1flox/flox mated with Lyz2-Cre+mice to obtain Spi1flox/+/Lyz2-Cre+mice,and then mated with Spi1flox/flox,the Spi1flox/flox/Lyz2-Cre+mice were myeloid-specific Spi1 gene knockout(KO)mice.Spi1flox/flox/Lyz2-cre-mice were used as wild-type(WT)mice.DNA of WT and KO mice was extracted,and the genotypes were identified by agarose gel electro-phoresis after PCR amplification.Western blot was used to detect the expression of spleen focus forming virus provi-ral integration oncogene,Spi-1/purine rich box-1(PU.1)in immune cells of WT and KO mice.Results The results of PCR identification showed that the genotype of mice with only 220 bp amplified by flox primer was Spi1flox/flox homozygote,and the genotype of mice with 700 bp amplified by Lyz2-Cre primer was Lyz2-Cre+.Western blot showed that compared with WT group,the protein PU.1 was not expressed in bone marrow-derived macropha-ges(BMDMs)and peritoneal macrophages(PM)in KO group(P<0.01).There was no significant difference of statistics in the expression level of PU.1 in T cells between KO mice and WT mice.The results of PCR and West-ern blot showed that myeloid-specific Spi1 KO mice were successfully constructed.Conclusion The myeloid-spe-cific Spi1 gene KO mice are successfully constructed and identified,which provides animal model basis for further revealing the potential mechanism of PU.1 inimmune regulation.
9.Breeding and genotyping of T lymphocyte-conditional Spi1 knockout mice
Huihui WANG ; Xiangling ZHU ; Xuming WU ; Huiru ZHANG ; Yuanyuan ZHOU ; Anqi WANG ; Chong LIU ; Jiajie TU
Acta Universitatis Medicinalis Anhui 2024;59(4):595-599
Objective To breed and identify the T lymphocyte-conditional Spi1 knockout mice for the further in-vestgation of the specific role of Spi1-encoded protein PU.1.Methods The Lck-Cre mice were mated with Spi1flox/flox mice to obtain Lck-Cre×Spi1flox/flox mice(T lymphocyte-specific Spi1 knockout mice),and the genotype was determined by polymerase chain reaction(PCR)and agarose gel electrophoresis.Magnetic beads were used to sort out the splenic T lymphocytes,and the knockdown efficiency of PU.1 in T cells was detected by Western blot,quantitative real-time PCR(qPCR)and flow cytometry.Results The Lck-Cre×Spi1flox/flox mouse genotype was stably inherited.Compared with Spi1flox/flox mice,the expression level of PU.1 was significantly reduced in splenic T cells of Lck-Cre×Spi1flox/flox mice.Conclusion In this study,the T lymphocyte-specific Spi1 knockout mice was successfully constructed by applying Cre/LoxP system and CRISPR/Cas9 technology,which provided a reliable an-imal model for the subsequent experiments of the specific role of PU.1 in T cell-related diseases.
10.Construction and efficiency detection of Csf1r-CreERT2 R26REYFP reporter gene mouse based on Cre/Loxp system
Xiangling ZHU ; Xuming WU ; Huihui WANG ; Yuanyuan ZHOU ; Anqi WANG ; Huiru ZHANG ; Chong LIU ; Jiajie TU
Acta Universitatis Medicinalis Anhui 2024;59(7):1175-1180
Objective To construct Csf1r-CreERT2 R26REYFP reporter gene mice and assess the efficacy of Csf1r-CreERT2-mediated enhancement of CSF1R in CD45+cells labeled with yellow fluorescein protein EYFP.Methods Csf1r-CreERT2 mice were crossbred with R26REYFP homozygous mice,and Csf1r-CreERT2R26REYFP mice were identified through PCR and Western Blot analyses.Flow cytometry was employed to evaluate CSF1R tag-efficiency in CD45+cells across different mouse tissues following tamoxifen induction.Results Csf1r-CreERT2 R26REYFP reporter gene mice were acquired.In addition,it was found that Csf1r-CreERT2-mediated EYFP could effectively mark CSF1R in various tissues of mice and CD45+cells in different locations.Compared to the R26REYF P group,the highest labeling efficiency was observed in the brain tissue(P<0.001),the lowest in the thymus tissue(P<0.05),and no sig-nificant difference was observed in the spleen tissue.Conclusion Adult Csf1r-CreERT2 mice and R26REYFP mice are effective ways to obtain Csf1r-CreERT2 R26REYFP induced conditional fluorescence mice.Csf1r-CreERT2 can mediate EYFP to effectively trace CSF1R in CD45+cells in different parts of mice.


Result Analysis
Print
Save
E-mail