1.Arthrodesis for Eaton-Littler stage III degenerative trapeziometacarpal arthritis: a retrospective comparative study of fixation methods
Jun-Ku LEE ; Chi-Hoon OH ; Woo Yeol AHN ; Sung Woo LEE ; Seungyeon KANG ; Soo-Hong HAN
Archives of hand and microsurgery 2024;29(2):96-104
Purpose:
This study compared clinical outcomes depending on the fixation modality in patients who underwent arthrodesis surgery for Eaton-Littler stage III trapeziometacarpal (TM) joint arthritis between 2009 and 2022.
Methods:
In total, 39 patients with 44 hands (five patients had surgery on both hands) were selected. Depending on the operative fixation instruments, patients were divided into two groups: group 1, surgery with 25-gauge interosseous wiring and Kirschner wire or headless screw fixation; group 2, surgery with only multiple headless screws for fixation. Bone union was achieved at 62 days after surgery in group 1 and 75 days in group 2 (p=0.165).
Results:
The preoperative mean visual analogue scores improved during the postoperative outpatient follow-up period in both groups (group 1, from 4.0 preoperatively to 1.0 at the final follow-up; group 2, from 5.0 preoperatively to 2.0 at the final follow-up). Mean grip strength and pinch strength increased after surgery. One patient (4.8%) experienced nonunion in group 1, whereas nonunion occurred in four patients (17.4%) in group 2. This difference was not statistically significant. Four patients in group 1 and no patients in group 2 underwent fixation instrument removal after sound union.
Conclusion
Adequate stability can be achieved during arthrodesis by combining interosseous wiring and other implants or multiple headless compression screws, resulting in successful outcomes for patients with Eaton-Littler stage III degenerative TM arthritis.
2.Comparison of Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance During Transcatheter Aortic Valve Replacement
Sang-Hyup LEE ; Seunguk OH ; Young-Guk KO ; Yong-Joon LEE ; Seung-Jun LEE ; Sung-Jin HONG ; Chul-Min AHN ; Jung-Sun KIM ; Byeong-Keuk KIM ; Kyu-Yong KO ; Iksung CHO ; Chi Young SHIM ; Geu-Ru HONG ; Donghoon CHOI ; Myeong-Ki HONG
Korean Circulation Journal 2024;54(2):63-75
Background and Objectives:
Evidence regarding the efficacy and safety of intracardiac echocardiography (ICE) for guidance during transcatheter aortic valve replacement (TAVR) is limited. This study aimed to compare the clinical efficacy and safety of ICE versus transesophageal echocardiography (TEE) for guiding TAVR.
Methods:
This prospective cohort study included patients who underwent TAVR from August 18, 2015, to June 31, 2021. Eligible patients were stratified by echocardiographic modality (ICE or TEE) and anesthesia mode (monitored anesthesia care [MAC] or general anesthesia [GA]). Primary outcome was the 1-year composite of all-cause mortality, rehospitalization for cardiovascular cause, or stroke, according to the Valve Academic Research Consortium-3 (VARC-3) definition. Propensity score matching was performed, and study outcomes were analyzed for the matched cohorts.
Results:
Of the 359 eligible patients, 120 patients were matched for the ICE-MAC and TEEGA groups, respectively. The incidence of primary outcome was similar between matched groups (18.3% vs. 20.0%; adjusted hazard ratio, 0.94; 95% confidence interval [CI], 0.53– 1.68; p=0.843). ICE-MAC and TEE-GA also had similar incidences of moderate-to-severe paravalvular regurgitation (PVR) (4.2% vs. 5.0%; adjusted odds ratio, 0.83; 95% CI, 0.23– 2.82; p=0.758), new permanent pacemaker implantation, and VARC-3 types 2–4 bleeding.
Conclusions
ICE was comparable to TEE for guidance during TAVR for the composite clinical efficacy outcome, with similar incidences of moderate-to-severe PVR, new permanent pacemaker implantation, and major bleeding. These results suggest that ICE could be a safe and effective alternative echocardiographic modality to TEE for guiding TAVR.
3.The Profile of Early Sedation Depth and Clinical Outcomes of Mechanically Ventilated Patients in Korea
Dong-gon HYUN ; Jee Hwan AHN ; Ha-Yeong GIL ; Chung Mo NAM ; Choa YUN ; Jae-Myeong LEE ; Jae Hun KIM ; Dong-Hyun LEE ; Ki Hoon KIM ; Dong Jung KIM ; Sang-Min LEE ; Ho-Geol RYU ; Suk-Kyung HONG ; Jae-Bum KIM ; Eun Young CHOI ; JongHyun BAEK ; Jeoungmin KIM ; Eun Jin KIM ; Tae Yun PARK ; Je Hyeong KIM ; Sunghoon PARK ; Chi-Min PARK ; Won Jai JUNG ; Nak-Jun CHOI ; Hang-Jea JANG ; Su Hwan LEE ; Young Seok LEE ; Gee Young SUH ; Woo-Sung CHOI ; Keu Sung LEE ; Hyung Won KIM ; Young-Gi MIN ; Seok Jeong LEE ; Chae-Man LIM
Journal of Korean Medical Science 2023;38(19):e141-
Background:
Current international guidelines recommend against deep sedation as it is associated with worse outcomes in the intensive care unit (ICU). However, in Korea the prevalence of deep sedation and its impact on patients in the ICU are not well known.
Methods:
From April 2020 to July 2021, a multicenter, prospective, longitudinal, noninterventional cohort study was performed in 20 Korean ICUs. Sedation depth extent was divided into light and deep using a mean Richmond Agitation–Sedation Scale value within the first 48 hours. Propensity score matching was used to balance covariables; the outcomes were compared between the two groups.
Results:
Overall, 631 patients (418 [66.2%] and 213 [33.8%] in the deep and light sedation groups, respectively) were included. Mortality rates were 14.1% and 8.4% in the deep and light sedation groups (P = 0.039), respectively. Kaplan-Meier estimates showed that time to extubation (P < 0.001), ICU length of stay (P = 0.005), and death P = 0.041) differed between the groups. After adjusting for confounders, early deep sedation was only associated with delayed time to extubation (hazard ratio [HR], 0.66; 95% confidence inter val [CI], 0.55– 0.80; P < 0.001). In the matched cohort, deep sedation remained significantly associated with delayed time to extubation (HR, 0.68; 95% 0.56–0.83; P < 0.001) but was not associated with ICU length of stay (HR, 0.94; 95% CI, 0.79–1.13; P = 0.500) and in-hospital mortality (HR, 1.19; 95% CI, 0.65–2.17; P = 0.582).
Conclusion
In many Korean ICUs, early deep sedation was highly prevalent in mechanically ventilated patients and was associated with delayed extubation, but not prolonged ICU stay or in-hospital death.
4.A Multicenter, Prospective, Observational Study to Evaluate Ethanol-Induced Symptoms in Patients Receiving Docetaxel Chemotherapy
Young-Woong WON ; Jin-Hyoung KANG ; Jung Hye KWON ; Dong-Hoe KOO ; Jung Hun KANG ; Chi Hoon MAENG ; Hee Kyung AHN ; Sung Yong OH ; Dae-Won LEE ; Joohyuk SOHN ; So Yeon OH ; Kyung Hee LEE ; Su-Jin KOH ; Keun Seok LEE ; Chan-Kyu KIM ; Ji-Yeon KIM ; Jun Ho JI ; Sung-Bae KIM ; Joo Young HA ; Ho Young KIM
Cancer Research and Treatment 2023;55(4):1096-1103
Purpose:
Several previous studies and case reports have reported ethanol-induced symptoms in patients receiving anticancer drugs containing ethanol. Most docetaxel formulations contain ethanol as a solvent. However, there are insufficient data on ethanol-induced symptoms when docetaxel-containing ethanol is administered. The primary purpose of this study was to investigate the frequency and pattern of ethanol-induced symptoms during and after docetaxel administration. The secondary purpose was to explore the risk factors for ethanol-induced symptoms.
Materials and Methods:
This was a prospective, multicenter, observational study. The participants filled out ethanol-induced symptom questionnaire on the day of chemotherapy and the following day.
Results:
Data from 451 patients were analyzed. The overall occurrence rate of ethanol-induced symptoms was 44.3% (200/451 patients). The occurrence rate of facial flushing was highest at 19.7% (89/451 patients), followed by nausea in 18.2% (82/451 patients), and dizziness in 17.5% (79/451 patients). Although infrequent, unsteady walking and impaired balance occurred in 4.2% and 3.3% of patients, respectively. Female sex, presence of underlying disease, younger age, docetaxel dose, and docetaxel-containing ethanol amount were significantly associated with the occurrence of ethanol-induced symptoms.
Conclusion
The occurrence of ethanol-induced symptoms was not low in patients receiving docetaxel-containing ethanol. Physicians need to pay more attention to the occurrence of ethanol-induced symptoms and prescribe ethanol-free or low-ethanol-containing formulations to high-risk patients.
5.Clinical Outcomes of Transcatheter Aortic Valve Implantation for Native Aortic Valves in Patients with Low Coronary Heights
Hyeongsoo KIM ; Seung-Jun LEE ; Sung-Jin HONG ; Chi-Young SHIM ; Chul-Min AHN ; Jung-Sun KIM ; Byeong-Keuk KIM ; Geu-Ru HONG ; Young-Guk KO ; Donghoon CHOI ; Yangsoo JANG ; Myeong-Ki HONG
Yonsei Medical Journal 2021;62(3):209-214
Purpose:
Acute coronary occlusion is a rare but fatal complication that may occur during trans-catheter aortic valve implantation (TAVI) and appears more frequently in patients with low coronary heights. We evaluated the feasibility of self-expanding valves in patients with low coronary heights undergoing TAVI.
Materials and Methods:
TAVI for native aortic valve stenosis was conducted in 276 consecutive patients between 2015 and 2019 at our institute. Using multi-detector computed tomography (MDCT), information on the aortic valve, coronary arteries, and vascular anatomy in 269 patients was analyzed. Patients with low coronary heights were defined as those with coronary heights of 10 mm or less during MDCT analysis.
Results:
Among the 269 patients, 29 (10.8%) patients had coronary arteries with low heights. The mean coronary height was 8.9±1.2 mm in the left coronary artery. These patients with low coronary heights were treated with self-expandable (n=28) or balloon-expandable (n=1) valves. Prophylactic coronary protection with a guidewire, balloon, or stent prepositioned down at-risk coronary arteries was not pursued in all patients. No acute coronary occlusion occurred in any of these patients during TAVI. Five patients (17.9%) died during follow-up (average of 553.8 days), including four from non-cardiogenic causes and one from a cardiogenic (aggravation of heart failure) cause.
Conclusion
A considerable number of patients with low coronary heights were observed among TAVI candidates in this study. Use of a self-expandable valve may be feasible for successful TAVI without acute coronary occlusion in patients with low coronary heights.
6.Comparison of Transcatheter Aortic Valve Replacement between SelfExpanding versus Balloon-Expandable Valves in Patients with Small Aortic Annulus
Yong-Joon LEE ; Seung-Jun LEE ; Sung-Jin HONG ; Chi-Young SHIM ; Chul-Min AHN ; Jung-Sun KIM ; Byeong-Keuk KIM ; Geu-Ru HONG ; Young-Guk KO ; Donghoon CHOI ; Yangsoo JANG ; Myeong-Ki HONG
Korean Circulation Journal 2021;51(3):222-231
Background and Objectives:
Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus.
Methods:
A total of 70 patients with severe aortic stenosis and small annulus (mean diameter ≤23 mm or minimal diameter ≤21 mm on computed tomography) underwent TAVR with either a self-expanding valve with supra-annular location (n=45) or a balloon-expandable valve with intra-annular location (n=25). The echocardiographic hemodynamic parameters after TAVR and 1-year follow-up were compared.
Results:
Between the self-expanding and balloon-expandable valve-treated patients, the clinical outcomes including permanent pacemaker implantation (11.1% vs. 8.0%), acute kidney injury stage 2 or 3 (4.4% vs. 4.0%), and major vascular complication (4.4% vs. 0.0%) were similar without all-cause mortality, stroke, and life-threatening bleeding during 30-day follow-up. Compared with the balloon-expandable valve-treated patients, the self-expanding valve-treated patients presented larger effective orifice area (EOA) (1.46±0.28 vs. 1.75±0.42 cm2 , p=0.002) and indexed EOA (0.95±0.21 vs. 1.18±0.28 cm2 /m2 , p=0.001), whereas mean aortic valve gradient (11.7±2.9 vs. 8.9±5.2 mmHg, P=0.005) and incidence of ≥moderate prosthesis-patient mismatch (36.0% vs. 8.9%, p=0.009) were lower. These hemodynamic differences were maintained at 1-year follow-up.
Conclusions
TAVR with self-expanding valves was associated with superior hemodynamic outcomes compared with balloon-expandable valves in patients with small aortic annulus.
7.Transcatheter Aortic Valve Replacement with Minimal Contrast Dye in Patients with Renal Insufficiency
Jah Yeon CHOI ; Geu-Ru HONG ; Sung-Jin HONG ; Chi Young SHIM ; Chul-Min AHN ; Jung-Sun KIM ; Byeong-Keuk KIM ; Young-Guk KO ; Donghoon CHOI ; Yangsoo JANG ; Myeong-Ki HONG
Yonsei Medical Journal 2021;62(11):990-996
Purpose:
Concerns have been consistently raised in regards to the considerable amount of contrast dye used during transcatheter aortic valve replacement (TAVR) in patients with renal insufficiency. In the present study, we introduced minimal contrast TAVR and compared its 30-day clinical outcomes with conventional TAVR.
Materials and Methods:
We retrospectively investigated 369 patients who underwent TAVR between July 2011 and April 2020 in our institute. Among them, 93 patients with severe aortic stenosis and renal insufficiency (estimated glomerular filtration rate ≤50 mL/min/1.73 m2 ) were included and divided into a conventional TAVR group (n=56) and a minimal contrast TAVR group (n=37). In the minimal contrast TAVR group, the total amount of contrast was <10 mL during the entire TAVR procedure. Thirty-day major adverse clinical events (MACE), including death, stroke, implantation of permanent pacemaker, and initiation of hemodialysis, were investigated.
Results:
The incidence of MACE was significantly lower in the minimal contrast TAVR group than the conventional TAVR group (16.2% vs. 42.9%, p=0.010). Death occurred in 9 patients (16.1%) in the conventional TAVR group and in 0 patients in the minimal contrast group (p=0.011). Hemodialysis was initiated in 2 patients (5.4%) in the minimal contrast TAVR group and in 7 patients (12.5%) in the conventional TAVR group (p=0.256). Multivariate regression analysis showed that the minimal contrast TAVR procedure was an independent predictor for reducing MACE (hazard ratio 0.208, 95% confidence interval: 0.080–0.541, p=0.001).
Conclusion
Minimal contrast TAVR is feasible and shows more favorable short-term clinical outcomes than conventional TAVR in patients with renal insufficiency.
8.Awareness of Doctors’ Shared Decision-Making in Life-Sustaining Care Decisions
Dalyong KIM ; Hyun Jung LEE ; Soo-Young YU ; Jung Hye KWON ; Hee Kyung AHN ; Jee Hyun KIM ; Seyoung SEO ; Chi Hoon MAENG ; Seungtaek LIM ; Do Yeun KIM ; Sung Joon SHIN
Korean Journal of Hospice and Palliative Care 2021;24(4):204-213
Purpose:
At the end of life, communication is a key factor for good care. However, in clinical practice, it is difficult to adequately discuss end-of-life care. In order to understand and analyze how decision-making related to life-sustaining treatment (LST) is performed, the shared decision-making (SDM) behaviors of physicians were investigated.
Methods:
A questionnaire was designed after reviewing the literature on attitudes toward SDM or decision-making related to LST. A final item was added after consulting experts. The survey was completed by internal medicine residents and hematologists/medical oncologists who treat terminal cancer patients.
Results:
In total, 202 respondents completed the questionnaire, and 88.6% said that the decision to continue or end LST is usually a result of SDM since they believed that sufficient explanation is provided to patients and caregivers, patients and caregivers make their own decisions according to their values, and there is sufficient time for patients and caregivers to make a decision. Expected satisfaction with the decisionmaking process was the highest for caregivers (57.4%), followed by physicians (49.5%) and patients (41.1%). In total, 38.1% of respondents said that SDM was adequately practiced when making decisions related to LST. The most common reason for inadequate SDM was time pressure (89.6%).
Conclusion
Although most physicians answered that they practiced SDM when making decisions regarding LST, satisfactory SDM is rarely practiced in the clinical field. A model for the proper implementation of SDM is needed, and additional studies must be conducted to develop an SDM model in collaboration with other academic organizations.
9.Transcatheter Aortic Valve Replacement with Minimal Contrast Dye in Patients with Renal Insufficiency
Jah Yeon CHOI ; Geu-Ru HONG ; Sung-Jin HONG ; Chi Young SHIM ; Chul-Min AHN ; Jung-Sun KIM ; Byeong-Keuk KIM ; Young-Guk KO ; Donghoon CHOI ; Yangsoo JANG ; Myeong-Ki HONG
Yonsei Medical Journal 2021;62(11):990-996
Purpose:
Concerns have been consistently raised in regards to the considerable amount of contrast dye used during transcatheter aortic valve replacement (TAVR) in patients with renal insufficiency. In the present study, we introduced minimal contrast TAVR and compared its 30-day clinical outcomes with conventional TAVR.
Materials and Methods:
We retrospectively investigated 369 patients who underwent TAVR between July 2011 and April 2020 in our institute. Among them, 93 patients with severe aortic stenosis and renal insufficiency (estimated glomerular filtration rate ≤50 mL/min/1.73 m2 ) were included and divided into a conventional TAVR group (n=56) and a minimal contrast TAVR group (n=37). In the minimal contrast TAVR group, the total amount of contrast was <10 mL during the entire TAVR procedure. Thirty-day major adverse clinical events (MACE), including death, stroke, implantation of permanent pacemaker, and initiation of hemodialysis, were investigated.
Results:
The incidence of MACE was significantly lower in the minimal contrast TAVR group than the conventional TAVR group (16.2% vs. 42.9%, p=0.010). Death occurred in 9 patients (16.1%) in the conventional TAVR group and in 0 patients in the minimal contrast group (p=0.011). Hemodialysis was initiated in 2 patients (5.4%) in the minimal contrast TAVR group and in 7 patients (12.5%) in the conventional TAVR group (p=0.256). Multivariate regression analysis showed that the minimal contrast TAVR procedure was an independent predictor for reducing MACE (hazard ratio 0.208, 95% confidence interval: 0.080–0.541, p=0.001).
Conclusion
Minimal contrast TAVR is feasible and shows more favorable short-term clinical outcomes than conventional TAVR in patients with renal insufficiency.
10.Comparison of Transcatheter Aortic Valve Replacement between SelfExpanding versus Balloon-Expandable Valves in Patients with Small Aortic Annulus
Yong-Joon LEE ; Seung-Jun LEE ; Sung-Jin HONG ; Chi-Young SHIM ; Chul-Min AHN ; Jung-Sun KIM ; Byeong-Keuk KIM ; Geu-Ru HONG ; Young-Guk KO ; Donghoon CHOI ; Yangsoo JANG ; Myeong-Ki HONG
Korean Circulation Journal 2021;51(3):222-231
Background and Objectives:
Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus.
Methods:
A total of 70 patients with severe aortic stenosis and small annulus (mean diameter ≤23 mm or minimal diameter ≤21 mm on computed tomography) underwent TAVR with either a self-expanding valve with supra-annular location (n=45) or a balloon-expandable valve with intra-annular location (n=25). The echocardiographic hemodynamic parameters after TAVR and 1-year follow-up were compared.
Results:
Between the self-expanding and balloon-expandable valve-treated patients, the clinical outcomes including permanent pacemaker implantation (11.1% vs. 8.0%), acute kidney injury stage 2 or 3 (4.4% vs. 4.0%), and major vascular complication (4.4% vs. 0.0%) were similar without all-cause mortality, stroke, and life-threatening bleeding during 30-day follow-up. Compared with the balloon-expandable valve-treated patients, the self-expanding valve-treated patients presented larger effective orifice area (EOA) (1.46±0.28 vs. 1.75±0.42 cm2 , p=0.002) and indexed EOA (0.95±0.21 vs. 1.18±0.28 cm2 /m2 , p=0.001), whereas mean aortic valve gradient (11.7±2.9 vs. 8.9±5.2 mmHg, P=0.005) and incidence of ≥moderate prosthesis-patient mismatch (36.0% vs. 8.9%, p=0.009) were lower. These hemodynamic differences were maintained at 1-year follow-up.
Conclusions
TAVR with self-expanding valves was associated with superior hemodynamic outcomes compared with balloon-expandable valves in patients with small aortic annulus.

Result Analysis
Print
Save
E-mail