1.Syndrome Differentiation and Treatment of Atrial Fibrillation based on the Holistic View of "Spleen-Vessels-Heart-Spirit"
Yihang DU ; Chenglin DUAN ; Xueping ZHU ; Meng LYU ; Jiafan CHEN ; Yi WEI ; Yuanhui HU
Journal of Traditional Chinese Medicine 2025;66(1):89-92
Based on the holistic view of "spleen-vessels-heart-spirit" system, this article explores the pathogenesis and progression of atrial fibrillation. It is proposed that the onset of atrial fibrillation is due to failure of the spleen to transport and disharmony of blood vessels; phlegm and blood stasis obstructing the collaterals and damage to the heart structure are the basis of its pathogenesis; the unclear mind and disorder of body and spirit are the causes of its progression. Based on the characteristics of pathological changes in different stages of the disease, it is proposed that early treatment should focus on restoring the middle jiao, clearing and promoting blood vessels, using modified Yigong Powder (异功散); during the progression of the disease, treatment should remove blood stasis and phlegm, nourish heart and protect the pulse, using self-prescribed modified Mengshi Tongmai Decoction (礞石通脉汤); meanwhile, calming mind and stabilizing palpitations, and regulating spirit should be sequentially incorporated, with self-prescribed Jiazao Ningmai Decoction (甲枣宁脉汤) or Shenying Dingji Decoction (参英定悸汤) and modified as appropriate. Clinical treatment should focus on the whole disease course of atrial fibrillation, implementing stage-based treatments to enable early intervention and holistic regulation.
2.Treatment of Paroxysmal Atrial Fibrillation by Deficiency-Excess Pattern Identification Based on “Palpitations Caused by Wind Pathogen”
Yihang DU ; Yi WEI ; Ruoning CHAI ; Chenglin DUAN ; Xueping ZHU ; Meng LYU ; Zizhen CHEN ; Yuanhui HU
Journal of Traditional Chinese Medicine 2024;65(7):750-754
Paroxysmal atrial fibrillation can be attributed to the category of xinji (palpitations) and zhangchong (severe palpitations) in traditional Chinese medicine, and its onset has the characteristics of urgency, change, and movement, which is similar to the characteristics of diseases induced by wind pathogen. It is believed that the internal movement of wind pathogen runs through the whole course of this disease, and palpitations due to wind as the direct pathogenesis. Palpitations caused by wind pathogen showed different characteristics of deficiency and excess pattern. In the acute exacerbation period, excess wind is the main cause of disease. For excessive heat generating wind, the treatment is to clear the liver and extinguish wind by self-modified Lingxia Qinggan Decoction (羚夏清肝汤); for blood stasis generating wind, the treatment is to remove blood stasis and stop wind by self-modified Yandan Limai Decoction (延丹理脉汤); for phlegm-heat accumulation with wind, the treatment is to dissolve phlegm and eliminate wind by self-modified Lianlou Danxing Decoction (连蒌胆星汤). In the prolonged recovery period, deficiency wind is more common. For stirring of wind due to yin deficiency, the treatment is to nourish yin and extinguish wind by self-modified Zaoshao Zhenzhu Deoction (枣芍珍珠汤); for spleen deficiency generating wind, the treatment is to strengthen spleen and nourish wind by self-modified Shenying Dingji Deoction (参英定悸汤). Clinical prescriptions closely follow the characteristics of wind, weigh the changes of deficiency and excess, tailor with the patterns, and regulate qi and blood of the zang-fu organs, in order to extinguish wind and arrest convulsion.
3.Clinical application evaluation of the fluorescence quantitative PCR melting curve method for detecting fungal nucleic acid
Ping NI ; Juan XU ; Haitao HU ; Hailin PENG ; Wang LI ; Chenglin ZHOU ; Surong DONG
Chinese Journal of Clinical Laboratory Science 2024;42(9):641-647
Objective To evaluate the accuracy and clinical application value of the fluorescence quantitative PCR melting curve meth-od for detecting fungal nucleic acid.Methods 460 suspected or confirmed patients with respiratory fungal infections were enrolled in the study.The fluorescence quantitative PCR melting curve method was used as the test method,and the fungal 26S rRNA gene nucleic acid detection kit combined with Sanger sequencing was used as the reference method.Sputum samples from each study subject were collected and detected by the test method and reference method,respectively.The Kappa value of the two methods was calculated to evaluate the consistency of the results.Results Compared with the reference method,the overall conformity rate of the test method was 92.83%(427/460).Compared with the reference method,the positive conformity rates,negative conformity rates,and overall conformity rates of the test method for detecting 8 fungi,including Candida albicans,Candida glabrata,Candida krusei,Candida trop-icalis,Candida parapsilosis,Cryptococcus neoformans,Candida guilliermondii,and Aspergillus,were 97.34%(183/188),97.06%(264/272),and 97.17%(447/460),100.00%(33/33),99.77%(426/427),and 99.78%(459/460),100.00%(16/16),99.55%(442/444),and 99.57%(458/460),98.11%(52/53),99.75%(442/444),and 99.57%(458/460),95.08%(58/61),99.50%(397/399),and 98.91%(455/460),100.00%(9/9),99.56%(449/451),and 99.57%(458/460),85.00%(17/20),99.32%(437/440),and 98.70%(454/460),and 97.59%(81/83),97.88%(369/377),and 97.83%(450/460),respectively.The Kappa values for the consistency evaluation of the two methods'detection results were both greater than 0.8.Upon retesting the inconsistent re-sults of the two methods,it was found that 53.7%(22/41)of the detection results were consistent with the test method,and the others were consistent with the reference method.Conclusion The fluorescence quantitative PCR melting curve method can simultaneously detect 8 kinds of fungi,and the detection results are highly consistent with the reference method.It has unique advantages in fungal de-tection and important clinical application value.
4.Application value of the "liftoff" modular method in robot-assisted laparoscopic surgery for complex adrenal tumors
Shengtao ZENG ; Chenglin YANG ; Wei WANG ; Jiatao YE ; Zhengfei HU ; Xiaoming ZHANG ; Huifen ZHANG ; Tianpei LIU
Chinese Journal of Urology 2024;45(4):282-286
Objective:This study aims to explore the application value of the "liftoff" modular method in robot-assisted laparoscopic surgery for complex adrenal tumors.Methods:We retrospectively analyzed the clinical data of 15 patients with complex adrenal tumors treated at the General Hospital of Southern Theater Command from May 2022 to June 2023. The cohort comprised 5 males and 10 females with an average age of (47.6±7.8) years and a body mass index (BMI) of 26.5 (23.8-27.9) kg/m 2. Among the patients, 3 had a BMI ≥28 kg/m 2, 2 had diabetes, 6 had hypertension, and 1 had coronary heart disease. Preoperative endocrine hormone examination revealed abnormal blood catecholamines in 5 cases and abnormal blood cortisol in 2 cases. Ultrasound and CT scans indicated that 9 tumors were located on the left side and 6 on the right, with 4 cases showing tumor compression on adjacent large blood vessels or organs. The average tumor diameter was (7.61±2.79) cm, with 10 cases having a diameter ≥ 6 cm. All patients underwent laparoscopic adrenalectomy assisted by robots through the transperitoneal approach. The surgeries were performed in a lateral position under general anesthesia. The "liftoff" modular method was utilized to separate the treatment of adrenal tumors into lateral, medial, dorsal, cephalic, and adrenal renal plane sides. Tumors were appropriately manipulated during the operations to achieve a "liftoff" shape. Different modular dissociation steps were adopted based on the size and location of the left and right adrenal tumors. The left adrenal gland was dissected in the order of medial and dorsal, adrenal renal plane side, and lateral and cephalic sides, while the right adrenal gland was dissected in the order of lateral and dorsal, adrenal renal plane side, and medial and cephalic sides. Postoperative related indicators and follow-up status of patients were recorded and analyzed. Results:All 15 surgeries were successfully completed without any conversions to open adrenalectomy, with an average operation time of 118 (102-130) minutes and an average intraoperative blood loss of 102 (69-163) ml. The postoperative drainage time was 4 (3-5) days, and the postoperative hospital stay was 6 (4-7) days. The postoperative pathological diagnoses included 5 cases of pheochromocytoma, 3 cases of macronodular adrenal hyperplasia, 6 cases of adrenocortical adenoma, and 1 case of myelolipoma. Follow-up for 6-12 months after surgery showed good recovery and no recurrence.Conclusions:The application of the "liftoff" modular method in robot-assisted laparoscopic surgery for complex adrenal tumors is safe and feasible. It efficiently aids in tumor removal and holds significant clinical application value.
5.Application of Augmented Reality for Accurate Punctures During Stage 1 Sacral Neuromodulation
Haoyu YUAN ; Yuansong XIAO ; Xiaoyu LIN ; Lei ZHANG ; Chenglin YANG ; Zhengfei HU ; Yue YANG ; Peixian WU
International Neurourology Journal 2024;28(4):302-311
Purpose:
Precise electrode placement is crucial for the success of sacral neuromodulation (SNM). The aim of this study was to explore a more accurate and convenient method for positioning punctures during the first stage of SNM.
Methods:
This retrospective study compared preoperative baseline values, intraoperative indicators, postoperative scores, and other clinical data from 130 patients who underwent SNM electrode implantation at our department between 2018 and 2023. The patients were divided into an experimental group and a control group to assess the advantages and feasibility of augmented reality (AR)-guided sacral nerve electrode implantation.
Results:
The experimental group experienced fewer intraoperative puncture attempts and achieved more accurate AR-guided localization punctures. Additionally, there were more responsive electrode contact points (2.74±0.51 vs. 2.46±0.74) and a lower initial voltage postimplantation (1.09±0.39 V vs. 1.69±0.43 V). The number of intraoperative x-ray fluoroscopies was significantly lower in the experimental group than in the control group (5.94±1.46 vs. 9.22±1.93), leading to a shorter overall operation time (61.32±11.27 minutes vs. 83.49±15.84 minutes). Furthermore, there was no need for additional local anesthetic drugs during the surgery in the experimental group. Comparative observations revealed no significant differences in intraoperative blood loss or the sacral hole location for electrode implantation between the 2 groups. Although the incidence of wound infection and the rate of permanent implantation in stage 2 were similar in both groups, the pain score on the first day postoperation was significantly lower in the experimental group than in the control group (2.62±0.697 vs. 2.83±0.816).
Conclusions
AR-guided sacral nerve modulation implantation can reduce both the number of punctures and the duration of the operation while ensuring safety and effectiveness. This technique can enhance the contact points of the response electrode, effectively lower the initial response voltage, and stabilize the electrode.
6.Application of Augmented Reality for Accurate Punctures During Stage 1 Sacral Neuromodulation
Haoyu YUAN ; Yuansong XIAO ; Xiaoyu LIN ; Lei ZHANG ; Chenglin YANG ; Zhengfei HU ; Yue YANG ; Peixian WU
International Neurourology Journal 2024;28(4):302-311
Purpose:
Precise electrode placement is crucial for the success of sacral neuromodulation (SNM). The aim of this study was to explore a more accurate and convenient method for positioning punctures during the first stage of SNM.
Methods:
This retrospective study compared preoperative baseline values, intraoperative indicators, postoperative scores, and other clinical data from 130 patients who underwent SNM electrode implantation at our department between 2018 and 2023. The patients were divided into an experimental group and a control group to assess the advantages and feasibility of augmented reality (AR)-guided sacral nerve electrode implantation.
Results:
The experimental group experienced fewer intraoperative puncture attempts and achieved more accurate AR-guided localization punctures. Additionally, there were more responsive electrode contact points (2.74±0.51 vs. 2.46±0.74) and a lower initial voltage postimplantation (1.09±0.39 V vs. 1.69±0.43 V). The number of intraoperative x-ray fluoroscopies was significantly lower in the experimental group than in the control group (5.94±1.46 vs. 9.22±1.93), leading to a shorter overall operation time (61.32±11.27 minutes vs. 83.49±15.84 minutes). Furthermore, there was no need for additional local anesthetic drugs during the surgery in the experimental group. Comparative observations revealed no significant differences in intraoperative blood loss or the sacral hole location for electrode implantation between the 2 groups. Although the incidence of wound infection and the rate of permanent implantation in stage 2 were similar in both groups, the pain score on the first day postoperation was significantly lower in the experimental group than in the control group (2.62±0.697 vs. 2.83±0.816).
Conclusions
AR-guided sacral nerve modulation implantation can reduce both the number of punctures and the duration of the operation while ensuring safety and effectiveness. This technique can enhance the contact points of the response electrode, effectively lower the initial response voltage, and stabilize the electrode.
7.Application of Augmented Reality for Accurate Punctures During Stage 1 Sacral Neuromodulation
Haoyu YUAN ; Yuansong XIAO ; Xiaoyu LIN ; Lei ZHANG ; Chenglin YANG ; Zhengfei HU ; Yue YANG ; Peixian WU
International Neurourology Journal 2024;28(4):302-311
Purpose:
Precise electrode placement is crucial for the success of sacral neuromodulation (SNM). The aim of this study was to explore a more accurate and convenient method for positioning punctures during the first stage of SNM.
Methods:
This retrospective study compared preoperative baseline values, intraoperative indicators, postoperative scores, and other clinical data from 130 patients who underwent SNM electrode implantation at our department between 2018 and 2023. The patients were divided into an experimental group and a control group to assess the advantages and feasibility of augmented reality (AR)-guided sacral nerve electrode implantation.
Results:
The experimental group experienced fewer intraoperative puncture attempts and achieved more accurate AR-guided localization punctures. Additionally, there were more responsive electrode contact points (2.74±0.51 vs. 2.46±0.74) and a lower initial voltage postimplantation (1.09±0.39 V vs. 1.69±0.43 V). The number of intraoperative x-ray fluoroscopies was significantly lower in the experimental group than in the control group (5.94±1.46 vs. 9.22±1.93), leading to a shorter overall operation time (61.32±11.27 minutes vs. 83.49±15.84 minutes). Furthermore, there was no need for additional local anesthetic drugs during the surgery in the experimental group. Comparative observations revealed no significant differences in intraoperative blood loss or the sacral hole location for electrode implantation between the 2 groups. Although the incidence of wound infection and the rate of permanent implantation in stage 2 were similar in both groups, the pain score on the first day postoperation was significantly lower in the experimental group than in the control group (2.62±0.697 vs. 2.83±0.816).
Conclusions
AR-guided sacral nerve modulation implantation can reduce both the number of punctures and the duration of the operation while ensuring safety and effectiveness. This technique can enhance the contact points of the response electrode, effectively lower the initial response voltage, and stabilize the electrode.
8.Robotic-assisted laparoscopic modified ventral onlay lingual mucosal graft in complex ureteral stricture construction: experience of eight cases
Haoxiang XU ; Chenglin YANG ; Wei WANG ; Zhi CAO ; Zhengfei HU ; Xiaoming ZHANG ; Yuansong XIAO
Chinese Journal of Surgery 2023;61(11):1012-1017
Objective:To examine the efficacy of robot-assisted laparoscopic modified ventral onlay lingual mucosal graft for complex ureteral stricture.Methods:The clinical data of 8 patients with ureteral stricture admitted to the Department of Urology, General Hospital of Southern Theater Command from May to October 2022 were retrospectively analyzed. There were 6 males and 2 females, aged (45.1±10.2) years (range: 34 to 64 years), body mass index (24.6±2.0) kg/m 2 (range: 20.7 to 26.6 kg/m 2). Five cases on the left side, 3 cases on the right side, the length of the ureteral structure was (3.1±0.7) cm (range: 2.2 to 4.5 cm). The value of preoperative serum creatinine was (113.8±22.3) μmol/L (range: 96 to 15 μmol/L). Before excising the structure segment, the titched anastomosed part of the dorsal wall of the ureter, and then the posteriorly augmented anastomotic, the remaining ventral side was augmented with a onlay lingual mucosa graft, then the omentum flap was used to wrap the reconstructed ureteral segment. The lingual mucosa graft with a length of 2.5 to 5.0 cm and a width of 1.0 to 1.5 cm was cut according to the actual structure. The surgery information of the patient, complications, and recent follow-up were recorded. Results:The operation under robot-assisted laparoscopy was performed successfully in the 8 patients without conversion to open surgery. The duration of the operation was (226.9±22.8) minutes (range: 210 to 255 minutes), estimated blood loss was (93.8±25.9) ml (range: 75 to 150 ml), the retention time of the postoperative drainage tube was (4.8±1.3) days (range: 3 to 7 days), and the duration of postoperative hospitalization was (11.1±3.6) days (range: 9 to 14 days). One week after the operation, the patient could pronounce correctly, enunciate clearly, and eat normally. Double J tubes were removed 4 to 8 weeks after the operation. The follow-up time in this group was 3 to 9 months, the follow-up patients underwent imaging and other examinations, which showed a significant improvement in hydronephrosis on the affected side, and the value of renal pelvic separation on the affected side was (1.4±0.8) cm (range: 0 to 2.3 cm). The serum creatinine value was (100.1±24.9) μmol/L (range: 76 to 155 μmol/L). Three months after the operation, the ureteroscopy showed that the ureter was smooth and the mucosa was normal.Conclusions:Robot-assisted laparoscopic ureteroplasty with a lingual mucosal graft is a safe and feasible operation for complex ureteral stricture without serious complications, which provides a surgical option for repairing ureteral stricture.
9.Robotic-assisted laparoscopic modified ventral onlay lingual mucosal graft in complex ureteral stricture construction: experience of eight cases
Haoxiang XU ; Chenglin YANG ; Wei WANG ; Zhi CAO ; Zhengfei HU ; Xiaoming ZHANG ; Yuansong XIAO
Chinese Journal of Surgery 2023;61(11):1012-1017
Objective:To examine the efficacy of robot-assisted laparoscopic modified ventral onlay lingual mucosal graft for complex ureteral stricture.Methods:The clinical data of 8 patients with ureteral stricture admitted to the Department of Urology, General Hospital of Southern Theater Command from May to October 2022 were retrospectively analyzed. There were 6 males and 2 females, aged (45.1±10.2) years (range: 34 to 64 years), body mass index (24.6±2.0) kg/m 2 (range: 20.7 to 26.6 kg/m 2). Five cases on the left side, 3 cases on the right side, the length of the ureteral structure was (3.1±0.7) cm (range: 2.2 to 4.5 cm). The value of preoperative serum creatinine was (113.8±22.3) μmol/L (range: 96 to 15 μmol/L). Before excising the structure segment, the titched anastomosed part of the dorsal wall of the ureter, and then the posteriorly augmented anastomotic, the remaining ventral side was augmented with a onlay lingual mucosa graft, then the omentum flap was used to wrap the reconstructed ureteral segment. The lingual mucosa graft with a length of 2.5 to 5.0 cm and a width of 1.0 to 1.5 cm was cut according to the actual structure. The surgery information of the patient, complications, and recent follow-up were recorded. Results:The operation under robot-assisted laparoscopy was performed successfully in the 8 patients without conversion to open surgery. The duration of the operation was (226.9±22.8) minutes (range: 210 to 255 minutes), estimated blood loss was (93.8±25.9) ml (range: 75 to 150 ml), the retention time of the postoperative drainage tube was (4.8±1.3) days (range: 3 to 7 days), and the duration of postoperative hospitalization was (11.1±3.6) days (range: 9 to 14 days). One week after the operation, the patient could pronounce correctly, enunciate clearly, and eat normally. Double J tubes were removed 4 to 8 weeks after the operation. The follow-up time in this group was 3 to 9 months, the follow-up patients underwent imaging and other examinations, which showed a significant improvement in hydronephrosis on the affected side, and the value of renal pelvic separation on the affected side was (1.4±0.8) cm (range: 0 to 2.3 cm). The serum creatinine value was (100.1±24.9) μmol/L (range: 76 to 155 μmol/L). Three months after the operation, the ureteroscopy showed that the ureter was smooth and the mucosa was normal.Conclusions:Robot-assisted laparoscopic ureteroplasty with a lingual mucosal graft is a safe and feasible operation for complex ureteral stricture without serious complications, which provides a surgical option for repairing ureteral stricture.
10. An Automatic HFO Detection Method Combining Visual Inspection Features with Multi-Domain Features
Xiaochen LIU ; Jizhong SHEN ; Lingli HU ; Shuai XU ; Shuang WANG ; Chenglin XU ; Zhong CHEN ; Zhong CHEN
Neuroscience Bulletin 2021;37(6):777-788
As an important promising biomarker, high frequency oscillations (HFOs) can be used to track epileptic activity and localize epileptogenic zones. However, visual marking of HFOs from a large amount of intracranial electroencephalogram (iEEG) data requires a great deal of time and effort from researchers, and is also very dependent on visual features and easily influenced by subjective factors. Therefore, we proposed an automatic epileptic HFO detection method based on visual features and non-intuitive multi-domain features. To eliminate the interference of continuous oscillatory activity in detected sporadic short HFO events, the iEEG signals adjacent to the detected events were set as the neighboring environmental range while the number of oscillations and the peak–valley differences were calculated as the environmental reference features. The proposed method was developed as a MatLab-based HFO detector to automatically detect HFOs in multi-channel, long-distance iEEG signals. The performance of our detector was evaluated on iEEG recordings from epileptic mice and patients with intractable epilepsy. More than 90% of the HFO events detected by this method were confirmed by experts, while the average missed-detection rate was < 10%. Compared with recent related research, the proposed method achieved a synchronous improvement of sensitivity and specificity, and a balance between low false-alarm rate and high detection rate. Detection results demonstrated that the proposed method performs well in sensitivity, specificity, and precision. As an auxiliary tool, our detector can greatly improve the efficiency of clinical experts in inspecting HFO events during the diagnosis and treatment of epilepsy.

Result Analysis
Print
Save
E-mail