1.Regulation of Zygotic Genome Activation in Early Embryonic Development
Ji-Xiang XING ; Han-Shuang LI ; Hai-Cheng LI ; Yong-Chun ZUO
Progress in Biochemistry and Biophysics 2024;51(3):525-543
The development of animal early embryos commences with the reprogramming of terminally differentiated gametes into totipotent zygotes following fertilization. During the initial stages of embryonic development, the transcriptional levels of zygotic genome remain silent and maternal gene products dominate the regulation of development. As embryonic development progresses, the maternal gene products undergo phased degradation while the zygotic genome gradually activates transcription, marking the transition from the maternal regulation to the zygotic genome regulation in early embryonic development, which is also referred to as the maternal-zygotic transition (MZT). Zygotic genome activation (ZGA) is a critical turning process in this transition, and its accurate occurrence is crucial for early embryonic development and cell fate decisions. However, the regulatory factors and molecular mechanisms of ZGA remain poorly understood. Studies have shown that ZGA varies greatly among different species and may be affected by a variety of regulatory factors such as DNA methylation, histone modification, non-coding RNA, chromatin remodeling and ZGA related factors. Here, we review the research progress of the above regulatory factors affecting ZGA, which can provide valuable insights for further investigations into the ZGA related mechanisms of early embryos.
2.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
3.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
4.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
5.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
6.Biomechanical Evaluation of 2 Endoscopic Spine Surgery Methods for Treating Lumbar Disc Herniation: A Finite Element Study
Yang ZOU ; Shuo JI ; Hui Wen YANG ; Tao MA ; Yue Kun FANG ; Zhi Cheng WANG ; Miao Miao LIU ; Ping Hui ZHOU ; Zheng Qi BAO ; Chang Chun ZHANG ; Yu Chen YE
Neurospine 2024;21(1):273-285
Objective:
This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods:
Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results:
In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion
In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
7.Neuroglobin Facilitates Neuronal Oxygenation through Tropic Migration under Hypoxia or Anemia in Rat: How Does the Brain Breathe?
Chun-Yang LI ; Hai-Feng JIANG ; Li LI ; Xiao-Jing LAI ; Qian-Rong LIU ; Shang-Bin YU ; Cheng-La YI ; Xiao-Qian CHEN
Neuroscience Bulletin 2023;39(10):1481-1496
The discovery of neuroglobin (Ngb), a brain- or neuron-specific member of the hemoglobin family, has revolutionized our understanding of brain oxygen metabolism. Currently, how Ngb plays such a role remains far from clear. Here, we report a novel mechanism by which Ngb might facilitate neuronal oxygenation upon hypoxia or anemia. We found that Ngb was present in, co-localized to, and co-migrated with mitochondria in the cell body and neurites of neurons. Hypoxia induced a sudden and prominent migration of Ngb towards the cytoplasmic membrane (CM) or cell surface in living neurons, and this was accompanied by the mitochondria. In vivo, hypotonic and anemic hypoxia induced a reversible Ngb migration toward the CM in cerebral cortical neurons in rat brains but did not alter the expression level of Ngb or its cytoplasm/mitochondria ratio. Knock-down of Ngb by RNA interference significantly diminished respiratory succinate dehydrogenase (SDH) and ATPase activity in neuronal N2a cells. Over-expression of Ngb enhanced SDH activity in N2a cells upon hypoxia. Mutation of Ngb at its oxygen-binding site (His64) significantly increased SDH activity and reduced ATPase activity in N2a cells. Taken together, Ngb was physically and functionally linked to mitochondria. In response to an insufficient oxygen supply, Ngb migrated towards the source of oxygen to facilitate neuronal oxygenation. This novel mechanism of neuronal respiration provides new insights into the understanding and treatment of neurological diseases such as stroke and Alzheimer's disease and diseases that cause hypoxia in the brain such as anemia.
Rats
;
Animals
;
Neuroglobin/metabolism*
;
Globins/metabolism*
;
Nerve Tissue Proteins/metabolism*
;
Neurons/metabolism*
;
Hypoxia/metabolism*
;
Brain/metabolism*
;
Oxygen
;
Anemia/metabolism*
;
Adenosine Triphosphatases/metabolism*
8.Analysis of prognostic factors of extranodal NK/T-cell lymphoma treated with pegaspargase/L-asparaginase: a multicenter retrospective study.
Zi Yuan SHEN ; Xi Cheng CHEN ; Hui Rong SHAN ; Tao JIA ; Wei Ying GU ; Fei WANG ; Qing Ling TENG ; Ling WANG ; Chun Ling WANG ; Yu Ye SHI ; Hao ZHANG ; Yu Qing MIAO ; Tai Gang ZHU ; Chun Yan JI ; Jing Jing YE ; Ming Zhi ZHANG ; Xu Dong ZHANG ; Liang WANG ; Kai Lin XU ; Wei SANG
Chinese Journal of Hematology 2023;44(8):642-648
Objective: To explore the prognostic factors of extracellular NK/T cell lymphoma (ENKTL) treated with pegaspargase/L-asparaginase. Methods: The clinical data of 656 ENKTL patients diagnosed at 11 medical centers in the Huaihai Lymphoma Working Group from March 2014 to April 2021 were retrospectively analyzed. The patients were randomly divided into two groups: a training set (460 cases) and a validation set (196 cases) at 7∶3, and the prognostic factors of the patients were analyzed. A prognostic scoring system was established, and the predictive performance of different models was compared. Results: Patients' median age was 46 (34, 57) years, with 456 males (69.5% ) and 561 nasal involvement (85.5% ). 203 patients (30.9% ) received a chemotherapy regimen based on L-asparaginase combined with anthracyclines, and the 5-year overall survival rate of patients treated with P-GEMOX regimen (pegaspargase+gemcitabine+oxaliplatin) was better than those treated with SMILE regimen (methotrexate+dexamethasone+cyclophosphamide+L-asparaginase+etoposide) (85.9% vs 63.8% ; P=0.004). The results of multivariate analysis showed that gender, CA stage, the Eastern Cooperative Oncology Group performance status (ECOG PS) score, HGB, and EB virus DNA were independent influencing factors for the prognosis of ENKTL patients (P<0.05). In this study, the predictive performance of the prognostic factors is superior to the international prognostic index, Korean prognostic index, and prognostic index of natural killer lymphoma. Conclusion: Gender, CA stage, ECOG PS score, HGB, and EB virus DNA are prognostic factors for ENKTL patients treated with pegaspargase/L-asparaginase.
Male
;
Humans
;
Middle Aged
;
Asparaginase/therapeutic use*
;
Prognosis
;
Retrospective Studies
;
Lymphoma, Extranodal NK-T-Cell/drug therapy*
;
Antineoplastic Combined Chemotherapy Protocols/therapeutic use*
;
Etoposide
;
Cyclophosphamide
;
Methotrexate/therapeutic use*
;
DNA/therapeutic use*
;
Treatment Outcome
9.A Family with Congenital Dysfibrinogenemia and Blood Transfusion.
Xiang-Cheng LIAO ; Shan-Shan ZHANG ; Zi-Ji YANG ; Chun-Li ZHU ; Hui-Ni HUANG ; Rui-Xian LUO ; Si-Na LI ; Hui-Qiong XIE ; Hai-Lan LI ; Zhu-Ning MO
Journal of Experimental Hematology 2023;31(5):1469-1474
OBJECTIVE:
To investigate a family with congenital dysfibrinogenemia, and analyze the risk of hemorrhage and thrombosis and blood transfusion strategies.
METHODS:
Prothrombin time (PT), activated partial thromboplastin time (APTT) and thrombin time (TT) of the proband and her family members were detected by automatic coagulometer, fibrinogen (Fg) activity and antigen were detected by Clauss method and PT algorithm respectively. Meanwhile, thromboelastometry was analyzed for proband and her family members. Then, peripheral blood samples of the proband and her family members were collected, and all exons of FGA, FGB and FGG and their flanks were amplified by PCR and sequenced to search for gene mutations.
RESULTS:
The proband had normal APTT and PT, slightly prolonged TT, reduced level of Fg activity (Clauss method). The Fg of the proband's aunt, son and daughter all decreased to varying degrees. The results of thromboelastogram indicated that Fg function of the proband and her family members (except her son) was basically normal. Gene analysis showed that there were 6233 G/A (p.AαArg35His) heterozygous mutations in exon 2 of FGA gene in the proband, her children and aunt. In addition, 2 polymorphic loci were found in the family, they were FGA gene g.9308A/G (p.AαThr331Ala) and FGB gene g.12628G/A (p.BβArg478Iys) polymorphism, respectively. The proband was injected with 10 units of cryoprecipitate 2 hours before delivery to prevent bleeding, and no obvious bleeding occurred during and after delivery.
CONCLUSION
Heterozygous mutation of 6233G/A (p.AαArg35His) of FGA gene is the biogenetic basis of the disease in this family with congenital dysfibrinogenemia.
Humans
;
Child
;
Female
;
Fibrinogen/genetics*
;
Pedigree
;
Afibrinogenemia/genetics*
;
Mutation
;
Blood Transfusion
10.Lifestyle improvement and the reduced risk of cardiovascular disease: the China-PAR project.
Ying-Ying JIANG ; Fang-Chao LIU ; Chong SHEN ; Jian-Xin LI ; Ke-Yong HUANG ; Xue-Li YANG ; Ji-Chun CHEN ; Xiao-Qing LIU ; Jie CAO ; Shu-Feng CHEN ; Ling YU ; Ying-Xin ZHAO ; Xian-Ping WU ; Lian-Cheng ZHAO ; Ying LI ; Dong-Sheng HU ; Jian-Feng HUANG ; Xiang-Feng LU ; Dong-Feng GU
Journal of Geriatric Cardiology 2023;20(11):779-787
BACKGROUND:
The benefits of healthy lifestyles are well recognized. However, the extent to which improving unhealthy lifestyles reduces cardiovascular disease (CVD) risk needs to be discussed. We evaluated the impact of lifestyle improvement on CVD incidence using data from the China-PAR project (Prediction for Atherosclerotic Cardiovascular Disease Risk in China).
METHODS:
A total of 12,588 participants free of CVD were followed up for three visits after the baseline examination. Changes in four lifestyle factors (LFs) (smoking, diet, physical activity, and alcohol consumption) were assessed through questionnaires from the baseline to the first follow-up visit. Cox proportional hazard models were used to estimate hazard ratios (HRs) and corresponding 95% confidence intervals (CIs). The risk advancement periods (RAPs: the age difference between exposed and unexposed participants reaching the same incident CVD risk) and population-attributable risk percentage (PAR%) were also calculated.
RESULTS:
A total of 909 incident CVD cases occurred over a median follow-up of 11.14 years. Compared with maintaining 0-1 healthy LFs, maintaining 3-4 healthy LFs was associated with a 40% risk reduction of incident CVD (HR = 0.60, 95% CI: 0.45-0.79) and delayed CVD risk by 6.31 years (RAP: -6.31 [-9.92, -2.70] years). The PAR% of maintaining 3-4 unhealthy LFs was 22.0% compared to maintaining 0-1 unhealthy LFs. Besides, compared with maintaining two healthy LFs, improving healthy LFs from 2 to 3-4 was associated with a 23% lower risk of CVD (HR = 0.77, 95% CI: 0.60-0.98).
CONCLUSIONS
Long-term sustenance of healthy lifestyles or improving unhealthy lifestyles can reduce and delay CVD risk.

Result Analysis
Print
Save
E-mail