2.Risk factors for the prognosis of rheumatoid arthritis-associated interstitial lung disease: a multicenter retrospective clinical study
Ning CHEN ; Longxin MA ; Chaoyue DIAO ; Jie GAO ; Dongbao ZHAO
Chinese Journal of Rheumatology 2023;27(3):171-177,c3-1
Objective:To explore the impact of clinical features, serological indicators, and pulmonary function test (PFT) on the prognosis of rheumatoid arthritis-associated interstitial lung disease (RA-ILD).Methods:Clinical data of RA-ILD patients who were diagnosed by HRCT and were followed up in Changhai Hospital or Yancheng First People's Hospital from 2011 to 2021 were collected Respiratory functional impairment of the patients was evaluated according to the changes of HRCT score and PFT, and the patients were divided into progressive group and stable group. COX survival analysis and ROC curve were used to determine the factors related to the progression of RA-ILD.Results:Finally 98 RA-ILD patients were included. The mean age of ILD onset was (62.9±12.1) years old, the median course of RA was 7.0 (1.0, 15.3)years, and the median follow-up time was 36.5 months (14.0, 79.5). There were 49 cases in the progressive group, and the clinical characteristics and laboratory tests of the two groups were compared. The results showed that: progressive time [(23(8.5,43.0)months vs 63(32.5,90.9) months, Z=-4.55, P=0.001)], HRCT score [(115(109,135) vs 111(105,116), Z=-2.70, P=0.007)], forced vital capacity(FVC) predicted [(70.1±15.7)% vs (80.8±19.7)%, t=2.12, P=0.039)], diffusing capacity of the lungs for CO(DLCO) predicted [(57.5±16.3)% vs (83.4±18.8)%, t=4.87, P=0.001)], male [(44.9% vs 18.4%, χ2=7.97, P=0.005)], UIP pattern [(36(73.5%) vs 9(18.4%), χ2=29.96, P<0.001)], RF>200 U/ml[(21(65.6%) vs 18(41.9%), χ2=4.15, P=0.042)], anti-CCP>75 U/ml [(42(91.3%) vs 35(71.4%), χ2=6.10, P=0.013], all had significantly different between the two groups. In multivariate analyses, UIP[ HR(95% CI)=3.25(1.62,6.50), P<0.001], anti-CCP antibody >75 U/ ml[ HR(95% CI)=3.85 (1.20,12.33), P=0.023] and smoking [ HR (95% CI): 5.74(1.10, 30.13), P=0.039] were significantly correlated with the progression of pulmonary fibrosis in RA-ILD patients. PFT was performed in only 44 patients with RA-ILD. The univariate analyses and ROC curve suggested that DLCO predicted [ HR (95% CI)=1.04 (1.02,1.06), P<0.001] was a significant risk factor for the progression of RA-ILD, and the area under curve (AUC) of DLCO was 0.845 [95% CI=(0.729,0.961)]. Conclusion:UIP pattern, high titer of anti-CCP antibody, smoking, and reduced DLCO predicted % may be potential predictors for poor prognosis of RA-ILD patients.
3.A new classification of atlas fracture based on CT reconstruction and its clinical significance
Weiyu JIANG ; Wenjie LU ; Yunlin CHEN ; Xudong HU ; Yang WANG ; Chaoyue RUAN ; Nanjian XU ; Rongming XU ; Weihu MA
Chinese Journal of Orthopaedics 2023;43(11):712-719
Objective:To investigate the clinical significance of a new classification system for atlas fractures based on pre- and post-treatment CT features, with a focus on diagnosis and treatment.Methods:A retrospective analysis was conducted on 75 cases of cervical vertebra fractures treated at the Sixth Hospital of Ningbo City between January 2015 and December 2020. The study included 44 males and 31 females, with an average age of 53.3±13.0 years (range: 27-81 years). The fractures were classified according to the Landells classification, resulting in 12 cases of type I, 13 cases of type II, 33 cases of type III, 9 cases that were difficult to classify due to fracture lines located at anatomical junctions, and 8 cases that could not be classified using the Landells classification due to diverse injury mechanisms. To establish a new preliminary classification for cervical vertebra fractures, the researchers considered whether the fracture line in the CT images involved the facet joint surface of the atlas, the impact on bilateral half-rings, and the displacement distance of the fracture ends. Five spinal surgeons were randomly selected to classify the CT images of the 75 patients using the new classification method. After one month, the imaging data of the 75 cases of cervical vertebra fractures were randomized and reclassified to assess the reliability and repeatability of the classification.Results:The new cervical vertebra fracture classification method comprised three types based on whether the fracture line involved the facet joint surface of the atlas: type A (no involvement of the facet joint surface of the atlas), type B (involvement of one side of the facet joint surface with intact contralateral half-ring), and type C (involvement of one side of the facet joint surface with fractured contralateral half-ring). Additionally, based on the maximum displacement distance between the fracture ends (>4 mm), six subtypes were identified: subtype 1 (≤4 mm displacement) and subtype 2 (>4 mm displacement). Consequently, the subtypes were classified as A1, A2, B1, B2, C1, and C2. According to the new classification method, the 75 patients included 17 cases of A1, 12 cases of A2, 7 cases of B1, 13 cases of B2, 12 cases of C1, and 14 cases of C2. The classification demonstrated excellent consistency, as assessed by the five doctors, with Kappa values of 0.85 and 0.91 for reliability and repeatability, respectively. At the final follow-up, all conservatively treated patients achieved bone healing, while four surgically treated patients experienced non-union of the fracture ends but exhibited good fusion between the atlas and axis. The remaining surgically treated patients achieved bony union without complications such as loosening or fracture of internal fixation.Conclusion:The new cervical vertebra fracture classification method, based on CT imaging features, comprehensively covers common clinical cases of cervical vertebra fractures and demonstrates excellent consistency. It provides valuable clinical guidance for the diagnosis and treatment of cervical vertebra fractures.
4.Engineered Bacillus subtilis alleviates intestinal oxidative injury through Nrf2-Keap1 pathway in enterotoxigenic Escherichia coli (ETEC) K88-infected piglet.
Chaoyue WEN ; Hong ZHANG ; Qiuping GUO ; Yehui DUAN ; Sisi CHEN ; Mengmeng HAN ; Fengna LI ; Mingliang JIN ; Yizhen WANG
Journal of Zhejiang University. Science. B 2023;24(6):496-509
Engineered probiotics can serve as therapeutics based on their ability of produce recombinant immune-stimulating properties. In this study, we built the recombinant Bacillus subtilis WB800 expressing antimicrobial peptide KR32 (WB800-KR32) using genetic engineering methods and investigated its protective effects of nuclear factor-E2-related factor 2 (Nrf2)-Kelch-like ECH-associated protein 1 (Keap1) pathway activation in intestinal oxidative disturbance induced by enterotoxigenic Escherichia coli (ETEC) K88 in weaned piglets. Twenty-eight weaned piglets were randomly distributed into four treatment groups with seven replicates fed with a basal diet. The feed of the control group (CON) was infused with normal sterilized saline; meanwhile, the ETEC, ETEC+WB800, and ETEC+WB800-KR32 groups were orally administered normal sterilized saline, 5×1010 CFU (CFU: colony forming units) WB800, and 5×1010 CFU WB800-KR32, respectively, on Days 1‒14 and all infused with ETEC K88 1×1010 CFU on Days 15‒17. The results showed that pretreatment with WB800-KR32 attenuated ETEC-induced intestinal disturbance, improved the mucosal activity of antioxidant enzyme (catalase (CAT), superoxide dismutase (SOD), and glutathione peroxidase (GPx)) and decreased the content of malondialdehyde (MDA). More importantly, WB800-KR32 downregulated genes involved in antioxidant defense (GPx and SOD1). Interestingly, WB800-KR32 upregulated the protein expression of Nrf2 and downregulated the protein expression of Keap1 in the ileum. WB800-KR32 markedly changed the richness estimators (Ace and Chao) of gut microbiota and increased the abundance of Eubacterium_rectale_ATCC_33656 in the feces. The results suggested that WB800-KR32 may alleviate ETEC-induced intestinal oxidative injury through the Nrf2-Keap1 pathway, providing a new perspective for WB800-KR32 as potential therapeutics to regulate intestinal oxidative disturbance in ETEC K88 infection.
Animals
;
Swine
;
Enterotoxigenic Escherichia coli
;
Kelch-Like ECH-Associated Protein 1
;
Bacillus subtilis
;
NF-E2-Related Factor 2
;
Antioxidants
;
Oxidative Stress
5.Safety of atlantoaxial transarticular screw combined with C 1 pedicle screw fixation
Dingli XU ; Weiyu JIANG ; Xudong HU ; Yunlin CHEN ; Nanjian XU ; Chaoyue RUAN ; Yang WANG ; Haojie LI ; Shuyi ZHOU ; Weihu MA
Chinese Journal of Trauma 2020;36(5):408-413
Objective:To investigate the safety of posterior atlantoaxial transarticular screw combined with atlas pedicle screw fixation in Chinese.Methods:CT data of upper cervical spine in 48 patients were collected from Ningbo No.6 Hospital, including 26 males and 22 females aged 26-58 years [(37.3±13.5)years]. All CT data was transformed into 3D dimensional model and inserted with virtual screws by Mimics 19.0. Firstly, the vertical plane P 1 and the horizontal plane P 2 of the atlas were built in those atlantoaxial models, secondly the atlantoaxial transarticular screw S 0 was inserted by Margel method, and it's insertion point was located at 3 mm lateral and 2 mm cephalad in the C 2 inferior articular process. Finally, four atlas pedicle screws were inserted at the midline of atlas lateral mass. The four screws are inserted as follows. S 1: the screw was tangent to the lateral side of the S 0 or the medial of the atlas pedicle. S 2: the screw was tangent to the lateral wall of the atlas pedicle. S 3: the screw was tangent to the upper wall of the atlas pedicle. S 4: the screw was tangent to the inferior wall of the atlas pedicle. The angles between S 1, S 2 and P 1 as the camber angle, and the angle between S 3, S 4 and P 2 as the gantry angle were measured. Then the safety range of camber angle and gantry angle were calculated, and the screw length of S 1, S 2, S 3 and S 4 was measured. In all models, the camber angle and gantry angle of the screws were adjusted an interval of 2°, the number of successful cases was calculated and the success rate of insertion was calculated. Results:All 3D models were inserted successfully. The minimum value, maximum value and safety range of the camber angle of atlas pedicle screws were (-6.7±5.2)°, (10.4± 4.3)°, (17.1±3.7)°, respectively; and of the gantry angle were (-0.5±3.5)°, (11.0±5.8)°, (11.5±4.9)°, respectively. The length of screw placement was S 1: (31.1±2.4)mm, S 2: (28.3±2.5)mm, S 3: (29.2±3.8)mm, S 4: (29.6±3.0)mm, respectively ( P<0.05). When the camber angle was from -1°to 5°, the success rate of screw placement was 87.5%; when inserting with 2° camber angle, the success rate was 100%; when the gantry angle was 5°, the success rate was 93.8%. Conclusion:The posterior atlantoaxial transarticular screw combined with atlas pedicle screw can achieve satisfy insertion length and success rate.
6. The safety and efficacy of ultrasound guided combined needle-perc and standard percutaneous nephrolithotomy in the treatment of staghorn stone
Boxing SU ; Bo XIAO ; Weiguo HU ; Chaoyue JI ; Yuzhe TANG ; Meng FU ; Song CHEN ; Jianxing LI
Chinese Journal of Urology 2020;41(1):37-40
Objective:
To summarize our preliminary clinical experience of ultrasound-guided needle-perc combined with standard percutaneous nephrolithotomy (PCNL) in the treatment of staghorn stones, and to analyze its safety and efficacy.
Methods:
The clinical data of 65 patients with staghorn stones treated by ultrasound-guided needle-perc combined with standard PCNL under general anesthesia with the patient in prone position from December 2017 to June 2019 were retrospectively reviewed. A total of 41 males and 24 females were included. The mean age was (53.5+ 8.9) years. The mean body mass index (BMI) was (25.1±2.9) kg/m2, and the mean stone diameter was (10.9±3.1) cm. Among them, there were 3 cases with bilateral staghorn stones, 38 cases with complete staghorn calculi, 36 cases with non- or mild preoperative hydronephrosis, 12 cases with previous ipsilateral renal surgery, and 9 cases with solitary kidneys. Ultrasound-guided renal access and tract dilation were used to establish F24 standard channel. Pneumatic combined with ultrasonic lithotripsy with suction system was used to treat staghorn stones under nephroscope. Needle-perc consists of F4.2 needle-like metal sheath connected with a three-way tube. A 0.6 mm diameter video fiber, 200 um holmium laser fiber and liquid perfusion device can be connected through the three-way tube respectively. The residual stone in the parallel calyx after standard PCNL were punctured by needle-perc under ultrasound guidance, and then the holmium laser fiber was used for lithotripsy.
Results:
In this study, a total of 68 renal units were included. The median operative time was 79.8 minutes, ranging 45-129 minutes. The median decrease of hemoglobin on postoperative day 1 was 10.6 g/L, ranging 0-25.9 g/L. The median length of postoperative hospital stay was 5.5 days, ranging 4-7 days and the median time of tract establishment was 4.8 minutes, ranging 2.5-9.6 minutes. The median number of standard tract established was 1.5, ranging 1-3 and the median number of needle-perc punctured was 1.0, ranging 1-3. The total complication rate was 10.3% (7 cases), including 5 cases of Clavien grade Ⅰ, 2 cases of postoperative fever, 3 cases of analgesic use. There were 2 cases of Clavien grade Ⅱ. All of them were blood transfusion. The initial stone free rate was 79.4%(54/68). Of the 14 patients with residual stones, 9 patients underwent second-stage operation, 7 patients were stone free, and the final stone free rate was 89.7%(61/68).
Conclusions
Ultrasound-guided needle-perc combined with standard PCNL is safe and effective in the treatment of staghorn stone.
7.The initial clinical application of needle-perc in upper urinary tract stones
Bo XIAO ; Jianxing LI ; Weiguo HU ; Yuzhe TANG ; Boxing SU ; Song CHEN ; Yubao LIU ; Meng FU ; Chaoyue JI
Chinese Journal of Urology 2019;40(2):96-99
Objective To describe and introduce the initial clinical application of a novel instrument needle-perc for percutaneous nephrolithotomy (PCNL) in upper urinary tract stones.Methods 24 patients with upper urinary stone treated by PCNL were collected retrospectively between August 2017 and January 2018.Sixteen patients were male and 8 were female.Average age was 41.2 years,ranging 26-65 years.Eight cases had upper pole stones,6 cases had pelvic stones,8 cases had lower pole stones and 4 cases had the stone in UPJ.The mean calculus size was 1.2 cm,ranging 0.5-1.4 cm.All patients were punctured under total ultrasound with needle-perc.Six cases had upper calyceal puncture,10 cases had middle calyceal puncture and 8 cases had lower calyceal puncture.The needle-shaped nephroscope consists of a puncture sheath and a needle handle.The puncture sheath is a hollow metal sheath with an outer diameter of F4.2,an inner diameter of F3.6,and a length of 15 cm.The tip of the sheath is beveled to facilitate puncture.The outer end of sheath is connected to the needle handle through a screw interface.And the three interfaces of the three-way tube can be respectively connected with a liquid irrigation device,a video optical fiber and a 200 μm holmium laser fiber.The needle-perc integrated image system,the irrigation system,and the nephroscope channel are integrated.The tissue passing through the needle can be simultaneously observed through video optical fiber during puncturing.After the tip of the sheath is inserted into the target calyx,the holmium laser fiber is connected for fragmenting or dusting.Results Needle-perc was successful in 22 cases,2 patients were converted to larger tract(F16).The mean opeartive time was 49.2 min,ranging 22-75 min and the mean hemoglobin loss was 5.2 g/L,ranging 0-13.8 g/L.Mean postoperative hospital stay was 3 days,ranging 1 to 6 days.No Double-J stents or nephrostomy tube was placed in the 22 patients.Complications (Clavien Ⅱ) occurred in 4 cases,including fever in 2 cases and renal colic in 2 cases.Plain film of KUB or CT scan was done and stone free rate at 1 month was 90.9% (20/22),2 patients needed ESWL to remove the residual stones.Conclusions Needle-perc is efficient and safe for small renal stones (size < 1.5 cm) from our initial experience,with high stone-free rate and low complication rate in early follow-up.
8. Efficacy comparison of posterior atlantoaxial screw-rod fixation combined with spinous process muscle-vessel complex bone graft or iliac bone graft for atlantoaxial instability
Dingli XU ; Weiyu JIANG ; Chaoyue RUAN ; Yang WANG ; Xudong HU ; Yunlin CHEN ; Nanjian XU ; Haojie LI ; Shuyi ZHOU ; Weihu MA
Chinese Journal of Trauma 2019;35(10):871-879
Objective:
To compare the clinical efficacy of posterior atlantoaxial screw-rod fixation combined with spinous process muscle-vessel complex bone graft or iliac bone graft for atlantoaxial instability.
Methods:
A retrospective case-control study was conducted to analyze the clinical data of 56 patients with atlantoaxial instability admitted to the Sixth Hospital of Ningbo from September 2014 to October 2016. There were 35 males and 21 females, with the age range from 9 to 59 years [(50.3±3.2)years]. A total of 26 patients were treated with posterior atlantoaxial screw-rod fixation combined with spinous process muscle-vessel complex bone graft (complex group), while 30 patients were treated with iliac bone graft (ilium group). Patients showed different degrees of neck pain and limited neck activity preoperatively. X-ray films and three-dimensional CT examination of the cervical spine were taken before and after operation for evaluating the atlantoaxial reduction, bone graft fusion and internal fixation. The operation time, intraoperative bleeding, bone fusion time, visual analogue scale (VAS), Japanese Orthopaedic Association (JOA) score, atlantodental interval (ADI) and axial symptoms were compared between the two groups, and the complications were recorded.
Results:
Both groups were followed up for 24-30 months, with an average of 27.4 months. In the complex group and the ilium group, the operation time was (2.21±0.25)hours and (2.72±0.26)hours (
9. Clinical application and effect of individual 3D printing model on pedicle screw placement for upper cervical spine fracture
Yunlin CHEN ; Xudong HU ; Yang WANG ; Nanjian XU ; Chaoyue RUAN ; Weiyu JIANG ; Weihu MA
Chinese Journal of Trauma 2019;35(11):970-976
Objective:
To investigate the accuracy and feasibility of individual 3D printing model for pedicle screw placement in treating patients with upper cervical spine fracture.
Methods:
A retrospective case control study was conducted to analyze the clinical data of 30 patients with upper cervical spine fracture admitted to Ningbo No.6 Hospital from August 2013 to December 2018. There were 19 males and 11 females, aged 45-67 years with an average age of 53.5 years. The 15 patients in the study group were treated with pedicle screw fixation and another 15 patients in the control group were treated with traditional freehand screw fixation. A total of 120 pedicle screws were implanted, with 60 screws in each group. The operation time, intraoperative blood loss, preoperative and postoperative visual analogue score (VAS), Japan Orthopedic Association (JOA) score were recorded. The position and grade of screws were evaluated according to Kawaguchi's evaluation method of screw grade after operation. The patients took monthly reexamination for the first three months after discharge. In the first two months after discharge, the patients took X-ray examination for observation of screw loosening or rupture of internal fixation. At the third month after operation, the patients took CT of cervical spine for observation of bone healing and fusion.
Results:
The mean follow-up duration was 17.8 months (range, 13-21 months). The study group had shorter operation time (99.13±3.04)minutes compared with the control group (107.00±6.92) minutes (
10. Efficacy comparison between microscope-assisted atlantal pedicle screw placement by hand and drill for unstable atlas burst fracture
Weiyu JIANG ; Danguo CHEN ; Xudong HU ; Yunlin CHEN ; Nanjian XU ; Chaoyue RUAN ; Yang WANG ; Dingli XU ; Weihu MA
Chinese Journal of Trauma 2019;35(11):991-997
Objective:
To investigate the efficacy of microscope-assisted free-hand atlantal pedicle screw technique for unstable atlas burst fracture.
Methods:
A retrospective case control study was conducted to analyze the clinical data of 48 patients with unstable atlas burst fracture admitted to Ningbo No.6 hospital from January 2016 to June 2018. There were 32 males and 16 females, aged 24-72 years [(49.5±15.2 years)]. A total of 22 patients were treated with the technique of atlas screw placement by drill under microscope (Group A), including 14 males and eight females, aged 24-68 years. Twenty six patients (Group B) were treated with atlantal pedicle screw placement by hand, including 18 males and 8 females, aged 26-72 years [(50.7±15.4 years)]. The operation time, intraoperative blood loss and the times of intraoperative fluoroscopy were compared between the two groups. X-ray and CT were reexamined to evaluate the accuracy of screw placement within one week after operation. The visual analogue score (VAS) and cervical dysfunction index (NDI) were compared before operation and 1 year after operation. The intraoperative complications were recorded. One year after operation, X-ray and CT were reexamined to observe fracture healing, atlantoaxial fusion and failure of internal fixation.
Results:
Group A was followed up for 12-24 months [(18.4±6.8)months], and Group B for 12-24 months [(17.4±7.2)months]. The amount of intraoperative bleeding [(180.5±60.8) ml] and the times of intraoperative fluoroscopy [(1.3±0.8) times] in Group A were significantly lower than those in Group B [(280.1±80.2) ml, (2.2±0.8) times] (

Result Analysis
Print
Save
E-mail