1.Risk Factor and Risk Prediction Modeling of Rectal Neuroendocrine Tumors
Liang XIE ; Chang LIU ; Jianhua LI ; Jianhui LI ; Xin HAO ; Haiyang HUA
Cancer Research on Prevention and Treatment 2025;52(7):598-604
Objective To analyze the risk factors associated with the occurrence of rectal neuroendocrine tumors (RNETs) and construct a risk prediction model. Methods Clinical data of patients who underwent electronic colonoscopy were collected. The clinical information on patients with and without RNETs were compared, and potential risk factors for RNETs were identified. Binary logistic regression was performed to analyze the relevant risk factors and construct a risk prediction model. Results Among 164 patients, 66 were diagnosed with RNETs, and 98 who did not have such a condition were randomly selected. Univariate logistic regression analysis revealed that age, fatty liver, anxiety and depression, total cholesterol, triglyceride levels, and carcinoembryonic antigen (CEA) were significant factors influencing the occurrence of RNETs (P<0.05). Multivariate logistic regression analysis identified age (P=0.015), anxiety and depression (P=0.031), cholesterol level (P=0.009), fatty liver (P=0.001), and CEA (P<0.001) as independent risk factors for RNETs. The participants were randomly divided into training and test sets at a 7:3 ratio. The training set was used to construct a nomogram-based risk prediction model, and the testing set was used for internal validation. The area under the curve values for the training and testing sets were 0.843 and 0.772, respectively (P>0.05). These findings indicate a good discriminative performance. The calibration curves for the training and testing sets were in good agreement with the 45° standard line, which suggests that the predicted probabilities were consistent with the actual outcomes. Decision curve analysis showed that the model provided a high net benefit within a threshold range of 0.2 to 0.7 for clinical decision making. Conclusion Young age, fatty liver, high CEA levels, high cholesterol levels, and anxiety and depression are independent risk factors for RNETs. The nomogram model constructed based on these risk factors exhibits a strong capability to predict the occurrence of RNETs, and clinical intervention can be considered based on the predicted probability values.
2.Machine learning-based quantitative prediction of drug drug interaction using drug label information
Lu-Hua LIANG ; Yu-Xi XU ; Bei QI ; Lu-Yao WANG ; Chang LI ; Rong-Wu XIANG
The Chinese Journal of Clinical Pharmacology 2024;40(16):2396-2400
Objective To construct machine learning models that can be used to predict AUC fold change(FC)using a database of existing pharmacokinetic(PK)and drug-drug interaction(DDI)information,which can be used to explore the possibility of predicting existing drug interactions and to provide certain rational recommendations for clinical drug use.Methods PK data of DDIs and AUC fold change data were extracted from FDA-approved drug labels.Peptide and pharmacodynamic(PD)information related to drug interactions were retrieved through DrugBank,and PPDT identification of relevant peptide IDs was performed using Protein Resource(UniProt),and a matrix normalization code was used to generate multidimensional vector data that were easy to analysis.The effect of PPDT on the AUC,and the resulting multiplicity change was used as the dependent variable for machine learning model construction.The model with the smallest root mean square error(RMES)value was used for model construction to train a bagged decision tree(Bagged)prediction model.The models were tested using the trained models for some of the drug tests.The models were evaluated by reviewing the available literature findings on detection of drug interaction pairs and analyzing and comparing the predicted values.Results A total of 16 pairs of model drug pairs were tested for the effects of 16 drugs on tacrolimus,and it was found that the accuracy of the prediction of the presence or absence of drug interactions was 81.25%;the prediction results were classified according to the FDA standard classification of the strong and weak for the strength of drug interactions,and the results showed that the prediction of the strength of drug interactions,with a large deviation from the larger prediction was less.Conclusion The evaluation of the model to predict the presence or absence of drug interactions was general;however,after classifying the strengths and weaknesses of drug interactions,the prediction of drug interactions was better,and the prediction results indicated that the model prediction performance has a certain reference value for potential DDI assessment before clinical trials.
3.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
4.Epidemiological Survey of Hemoglobinopathies Based on Next-Generation Sequencing Platform in Hunan Province, China.
Hui XI ; Qin LIU ; Dong Hua XIE ; Xu ZHOU ; Wang Lan TANG ; De Guo TANG ; Chun Yan ZENG ; Qiong WANG ; Xing Hui NIE ; Jin Ping PENG ; Xiao Ya GAO ; Hong Liang WU ; Hao Qing ZHANG ; Li QIU ; Zong Hui FENG ; Shu Yuan WANG ; Shu Xiang ZHOU ; Jun HE ; Shi Hao ZHOU ; Fa Qun ZHOU ; Jun Qing ZHENG ; Shun Yao WANG ; Shi Ping CHEN ; Zhi Fen ZHENG ; Xiao Yuan MA ; Jun Qun FANG ; Chang Biao LIANG ; Hua WANG
Biomedical and Environmental Sciences 2023;36(2):127-134
OBJECTIVE:
This study was aimed at investigating the carrier rate of, and molecular variation in, α- and β-globin gene mutations in Hunan Province.
METHODS:
We recruited 25,946 individuals attending premarital screening from 42 districts and counties in all 14 cities of Hunan Province. Hematological screening was performed, and molecular parameters were assessed.
RESULTS:
The overall carrier rate of thalassemia was 7.1%, including 4.83% for α-thalassemia, 2.15% for β-thalassemia, and 0.12% for both α- and β-thalassemia. The highest carrier rate of thalassemia was in Yongzhou (14.57%). The most abundant genotype of α-thalassemia and β-thalassemia was -α 3.7/αα (50.23%) and β IVS-II-654/β N (28.23%), respectively. Four α-globin mutations [CD108 (ACC>AAC), CAP +29 (G>C), Hb Agrinio and Hb Cervantes] and six β-globin mutations [CAP +8 (C>T), IVS-II-848 (C>T), -56 (G>C), beta nt-77 (G>C), codon 20/21 (-TGGA) and Hb Knossos] had not previously been identified in China. Furthermore, this study provides the first report of the carrier rates of abnormal hemoglobin variants and α-globin triplication in Hunan Province, which were 0.49% and 1.99%, respectively.
CONCLUSION
Our study demonstrates the high complexity and diversity of thalassemia gene mutations in the Hunan population. The results should facilitate genetic counselling and the prevention of severe thalassemia in this region.
Humans
;
beta-Thalassemia/genetics*
;
alpha-Thalassemia/genetics*
;
Hemoglobinopathies/genetics*
;
China/epidemiology*
;
High-Throughput Nucleotide Sequencing
5.Reinforced radiculoplasty for the treatment of symptomatic sacral Tarlov cysts: A clinical analysis of 71 cases.
Chao WU ; Bin LIU ; Jing Cheng XIE ; Zhen Yu WANG ; Chang Cheng MA ; Jun YANG ; Jian Jun SUN ; Xiao Dong CHEN ; Tao YU ; Guo Zhong LIN ; Yu SI ; Yun Feng HAN ; Su Hua CHEN ; Xiao Liang YIN ; Qian Quan MA ; Mu Tian ZHENG ; Lin ZENG
Journal of Peking University(Health Sciences) 2023;55(1):133-138
OBJECTIVE:
To investigate the safety and efficacy of reinforced radiculoplasty in the treatment of symptomatic sacral Tarlov cysts (TCs).
METHODS:
A retrospective analysis was performed on the clinical data and follow-up data of 71 patients with symptomatic sacral TCs who underwent reinforced radiculoplasty in the Neurosurgery Department of Peking University Third Hospital from June 2018 to March 2021. All the operations were performed under neuroelectrophysiological monitoring. Intraoperative cyst exploration, partial resection of the cyst wall, narrowing of the leak, nerve root sleeve radiculoplasty and artificial dural reinforcement were performed. The incidence of postoperative complications and new neurological dysfunction was analyzed. Visual analogue scale (VAS) was used to assess the changes of pain before and after surgery. The Japanese Orthopedics Association (JOA) low back pain score was used to evaluate the changes in nerve function before and after surgery.
RESULTS:
In the study, 71 patients had 101 TCs, 19 (18.8%) TCs originated from the left S1 nerve, 26 (25.7%) originated from the left S2 nerve, 3 (3.0%) originated from the left S3 nerve, 14 (13.9%) originated from the right S1 nerve, 33 (32.7%) originated from the right S2 nerve, 6 (5.9%) originated from the right S3 nerve, all the TCs underwent reinforced radiculoplasty. Deep infection (1 case), subcutaneous effusion (1 case), fat li-quefaction (1 case) and urinary tract infection (4 cases) were recorded postoperatively. The patients were followed up for 12-43 months (median, 26 months). Two cases had new urinary retention after operation, and the catheter was removed at the end of the first and second months respectively. One case had new fecal weakness, which improved after 3 months. Compared with preoperation, VAS decreased significantly at the last follow-up [median, 6 (4-9) vs. 1 (0-5), Z=-7.272, P < 0.001], JOA score increased significantly [median, 20 (16-25) vs. 27 (18-29), Z=-7.265, P < 0.001]. There were 18 cured cases (25.4%), 41 excellent cases (57.7%), 8 effective cases (11.3%), and 4 invalid cases (5.6%). The total efficiency was 94.4% (67/71). Two (1.98%) cysts recurred.
CONCLUSION
For patients with symptomatic sacral TCs, reinforced radiculoplasty can significantly improve the pain and nerve function, which is safe and reliable.
Humans
;
Tarlov Cysts/epidemiology*
;
Retrospective Studies
;
Neoplasm Recurrence, Local/complications*
;
Cysts/surgery*
;
Pain
6.Auditory response of the reticular nucleus of thalamus in awake mice.
Yu-Hua LI ; Chang-Bao SONG ; Fei-Xue LIANG
Acta Physiologica Sinica 2023;75(3):360-368
This study aims to explore the auditory response characteristics of the thalamic reticular nucleus (TRN) in awake mice during auditory information processing, so as to deepen the understanding of TRN and explore its role in the auditory system. By in vivo electrophysiological single cell attached recording of TRN neurons in 18 SPF C57BL/6J mice, we observed the responses of 314 recorded neurons to two kinds of auditory stimuli, noise and tone, applied to mice. The results showed that TRN received projections from layer six of the primary auditory cortex (A1). Among 314 TRN neurons, 56.05% responded silently, 21.02% responded only to noise and 22.93% responded to both noise and tone. The neurons with noise response can be divided into three patterns according to their response time: onset, sustain and long-lasting, accounting for 73.19%, 14.49% and 12.32%, respectively. The response threshold of the sustain pattern neurons was lower than those of the other two types. Under noise stimulation, compared with A1 layer six, TRN neurons showed unstable auditory response (P < 0.001), higher spontaneous firing rate (P < 0.001), and longer response latency (P < 0.001). Under tone stimulation, TRN's response continuity was poor, and the frequency tuning was greatly different from that of A1 layer six (P < 0.001), but their sensitivity to tone was similar (P > 0.05), and TRN's tone response threshold was much higher than that of A1 layer six (P < 0.001). The above results demonstrate that TRN mainly undertakes the task of information transmission in the auditory system. The noise response of TRN is more extensive than the tone response. Generally, TRN prefers high-intensity acoustic stimulation.
Rats
;
Mice
;
Animals
;
Wakefulness
;
Auditory Pathways/physiology*
;
Rats, Wistar
;
Mice, Inbred C57BL
;
Thalamus/physiology*
7.Clinical implications of the concentration of alveolar nitric oxide in non-small cell lung cancer.
Xiaodan CHANG ; Hua LIAO ; Lingyan XIE ; Yuehua CHEN ; Liying ZHENG ; Jianpeng LIANG ; Weiwei YU ; Yuexian WU ; Yanmei YE ; Shuyu HUANG ; Haijin ZHAO ; Shaoxi CAI ; Hangming DONG
Chinese Medical Journal 2023;136(18):2246-2248
8.Study on the application of model transfer technology in the extraction process of Xiao'er Xiaoji Zhike oral liquid
Xiu-hua XU ; Lei NIE ; Xiao-bo MA ; Xiao-qi ZHUANG ; Jin ZHANG ; Hai-ling DONG ; Wen-yan LIANG ; Hao-chen DU ; Xiao-mei YUAN ; Yong-xia GUAN ; Lian LI ; Hui ZHANG ; Xue-ping GUO ; Heng-chang ZANG
Acta Pharmaceutica Sinica 2023;58(10):2900-2908
The modernization and development of traditional Chinese medicine has led to higher standards for the quality of traditional Chinese medicine products. The extraction process is a crucial component of traditional Chinese medicine production, and it directly impacts the final quality of the product. However, the currently relied upon methods for quality assurance of the extraction process, such as simple wet chemical analysis, have several limitations, including time consumption and labor intensity, and do not offer precise control of the extraction process. As a result, there is significant value in incorporating near-infrared spectroscopy (NIRS) in the production process of traditional Chinese medicine to improve the quality control of the final products. In this study, we focused on the extraction process of Xiao'er Xiaoji Zhike oral liquid (XXZOL), using near-infrared spectra collected by both a Fourier transform near-infrared spectrometer and a portable near-infrared spectrometer. We used the concentration of synephrine, a quality control index component specified by the pharmacopoeia, to achieve rapid and accurate detection in the extraction process. Moreover, we developed a model transfer method to facilitate the transfer of models between the two types of near-infrared spectrometers (analytical grade and portable), thus resolving the low resolution, poor performance, and insufficient prediction accuracy issues of portable instruments. Our findings enable the rapid screening and quality analysis of XXZOL onsite, which is significant for quality monitoring during the traditional Chinese medicine production process.
9.Efficacy comparison of robot-assisted and free-hand long segment screw fixation combined with wedge osteotomy in the treatment of type IV chronic symptomatic osteoporotic thoracolumbar fractures
Xinhua YIN ; Dingjun HAO ; Zhongkai LIU ; Hua HUI ; Liang YAN ; Xiaobin YANG ; Lingbo KONG ; Zhen CHANG ; Baorong HE
Chinese Journal of Trauma 2023;39(7):619-626
Objective:To compare the clinical efficacies of robot-assisted and free-hand long segment screw fixation combined with wedge osteotomy in the treatment of type IV chronic symptomatic osteoporotic thoracolumbar fractures (CSOVCFs).Methods:A retrospective cohort study was conducted to analyze the clinical data of 72 patients with type IV CSOVCFs who were admitted to Honghui Hospital of Xi′an Jiaotong University from May 2019 to December 2021, including 22 males and 46 females; aged 61-82 years [(71.2±12.3)years]. Fracture segments were located at T 11-T 12 in 37 patients and at L 1-L 2 in 31. A total of 32 patients were treated with robot-assisted long segment screw fixation combined with wedge osteotomy (robot group) and 36 with free-hand long segment screw fixation combined with wedge osteotomy (free-hand group). The operation time, intraoperative bleeding volume, dosage of radiation exposure, intraoperative needle adjustment, time of single pedicle screw placement and accuracy of pedicle screw placement were compared between the two groups. The kyphotic Cobb angle, sagittal vertical axis (SVA), thoracic kyphosis (TK), lumbar kyphosis (LL), visual analogue scale (VAS) and Oswestry disability index (ODI) were measured preoperatively, at 3 days postoperatively and at the last follow-up. The incidences of facet joint violation, deviation in guide needle placement, cerebrospinal leak and proximal junctional kyphosis (PJK) were observed. Results:All patients were followed up for 12-26 months [(18.2±5.1)months]. The operation time and time of single pedicle screw placement showed no significant differences between the two groups (all P>0.05). The intraoperative bleeding volume was (502.5±58.3)ml in the robot group, less than that in the free-hand group [(690.2±45.9)ml]. The dosage of radiation exposure was (32.6±10.8)μSv in the robot group, lower than that in the free-hand group [(48.6±15.2)μSv]. The intraoperative needle adjustment was (2.1±0.3)times in the robot group, higher than that in the free-hand group [(20.7±5.8)times], and the accuracy of pedicle screw placement was 99.7% in the robot group, less than that in the free-hand group (91.8%) (all P<0.01). Compared with pre-operation, the kyphotic Cobb angle, SVA, TK and LL were significantly improved in both groups at postoperative 3 days and at the last follow-up (all P<0.05). Compared with postoperative 3 days, the kyphotic Cobb angle, SVA and TK were increased at the last follow-up within the two groups, but with no significant differences (all P>0.05). Compared with postoperative 3 days, the LL was decreased within the two groups at the last follow-up, but with no significant differences (all P>0.05). The VAS and ODI in the two groups were significantly lower at postoperative 3 days and at the last follow-up when compared with those before operation (all P<0.05), and both values were significantly lower at the last follow-up than those at postoperative 3 days (all P<0.05). There were no significant differences in the VAS or ODI at all time points between the two groups (all P>0.05). The incidence of facet joint violation in the robot group was 1.6%, markedly lower than that in the free-hand group (9.6%) ( P<0.01). The incidences of deviation in guide needle placement, cerebrospinal leak and PJK showed no differences between the two groups (all P>0.05). Conclusion:For type IV CSOVCFs, the robot-assisted long segment screw fixation combined with wedge osteotomy can better reduce intraoperative blood loss, decrease radiation exposure, improve accuracy of pedicle screw placement, and reduce facet joint violation when compared with free-hand long segment screw fixation combined with wedge osteotomy.
10.Efficacy of O-arm combined with CT three-dimensional navigation system assisted versus manual screw placement in the treatment of lower cervical fracture and dislocation
Shuai LI ; Jinpeng DU ; Jiang WANG ; Yunfei HUANG ; Zhigang ZHAO ; Zhen CHANG ; Xuefang ZHANG ; Liang YAN ; Hua HUI ; Xiaobin YANG ; Zhongkai LIU ; Lingbo KONG ; Bolong ZHENG ; Baorong HE
Chinese Journal of Trauma 2023;39(8):712-720
Objective:To compare the clinical efficacies of O-arm combined with CT three-dimensional navigation system assisted screw placement versus manual screw placement in treating lower cervical fracture and dislocation.Methods:A retrospective cohort study was used to analyze the clinical data of 41 patients with lower cervical fracture and dislocation, who were treated in Honghui Hospital, Xi′an Jiaotong University from May 2021 to February 2022. The patients included 26 males and 15 females, aged 31.5-48.6 years [(41.5±15.0)years]. The injured segments were C 3 in 3 patients, C 4 in 12, C 5 in 13, C 6 in 10 and C 7 in 3. Nineteen patients were treated with cervical pedicle screws by O-shaped arm combined with CT three-dimensional navigation system (navigation group, 76 screws) and 22 by bare hands (traditional group, 88 screws). The total operation time, effective operation time, single nail placement time, single screw correction times, screw distance from anterior cortex, intraoperative blood loss, intraoperative fluoroscopic radiation dose, incision length and length of hospital stay were compared between the two groups, and the height of intervertebral space, Cobb angle, interbody slip distance and American Spinal injury Association (ASIA) grade were compared before operation and at 3 days after operation. Visual analogue score (VAS), Japanese Orthopedic Association (JOA) score, and neck dysfunction index (NDI) were evaluated before operation, at 3 days, 3 months after operation and at the last follow-up. Accuracy of screw placement and incidence of complications (adjacent facet joint invasion, infection, screw loosening) were detected as well. Results:All the patients were followed up for 11.1-13.9 months [(12.5±1.4)months]. The total operation time, intraoperative blood loss, intraoperative fluoroscopic radiation dose and incision length in the navigation group were more or longer than those in the traditional group (all P<0.05). The effective operation time, single nail placement time, single nail correction times and screw distance from anterior cortex in the navigation group were markedly less or smaller than those in the traditional group (all P<0.05). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). There were significant improvements in the height of intervertebral space, Cobb angle and interbody slip distance between the two groups at 3 days after operation (all P<0.05). There was no significant difference in the height of intervertebral space, Cobb angle, interbody slip distance or ASIA grade between the two groups before operation or at 3 days after operation (all P>0.05). Compared with pre-operation, the VAS, JOA score and NDI were significantly improved in both groups at 3 days, 3 months after operation and at the last follow-up (all P<0.05), with further improvement with time. There was no significant difference in VAS between the two groups before operation or at 3 months after operation (all P>0.05), but it was markedly lower in the navigation group compared with the traditional group at 3 days after operation and at the last follow-up (all P<0.05). There were no significant differences in JOA score or NDI between the two groups before operation or at 3 days and 3 months after operation (all P>0.05), but both were lower in the navigation group compared with the traditional group at the last follow-up (all P<0.05). The accuracies of placement of grade 0 and grade 0+1 screws were 92.0% (70/76) and 96.6% (73/76) in the navigation group, respectively, which were markedly higher than 88.7% (78/88) and 93.5% (82/88) in the traditional group (all P<0.05). The rates of adjacent facet joint invasion of A, B, and C degrees were 71.2% (54/76), 28.8% (22/76) and 0% (0/76) in the navigation group, respectively, while the invasion rates were 60.5% (53/88), 32.3% (28/88) and 7.3% (7/88) in the traditional group ( P<0.05). No screw loosening was noted in the navigation group, but the screw loosening rate was 9.1% (8/88) in the traditional group ( P<0.01). Conclusion:Compared with manual screw placement, O-arm combined with CT three-dimensional navigation system assisted screw placement for lower cervical fracture and dislocation has the advantages of shorter effective operation time, quicker screw placement, stronger screw holding force, better cervical stability, slighter postoperative pain, higher screw placement accuracy, and lower facet joint invasion and screw loosening rates.

Result Analysis
Print
Save
E-mail