1.Quality Indicators of Endoscopic Retrograde Cholangiopancreatography in Korea
Hyung Ku CHON ; Ki-Hyun KIM ; Tae Jun SONG ; Dong-Won AHN ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Tae Joo JEON ; Chang Hwan PARK ; Kwang Bum CHO ; Dong Wook LEE ; Jin-Seok PARK ; Seung Bae YOON ; Kwang Hyun CHUNG ; Jin LEE ; Miyoung CHOI
Gut and Liver 2024;18(4):564-577
		                        		
		                        			
		                        			 Endoscopic retrograde cholangiopancreatography (ERCP) is a procedure that requires significant experiences and skills and has various procedure-related complications, some of which can be severe and even result in the death of patients. Expanding ERCP availability has the advantage of increasing accessibility for patients. However, ERCP poses a substantial risk if performed without proper quality management. ERCP quality management is essential for both ensuring safe and successful procedures and meeting the social demands for enhanced healthcare competitiveness and quality assurance. To address these concerns, the Korean Pancreatobiliary Association established a task force to develop ERCP quality indicators (QIs) tailored to the Korean medical environment. Key questions for five pre-procedure, three intra-procedure, and four post-procedure measures were formulated based on a literature search related to ERCP QIs and a comprehensive clinical review conducted by experts. The statements and recommendations regarding each QI item were selected through peer review. The developed ERCP QIs were reviewed by external experts based on the latest available evidence at the time of development.These domestically tailored ERCP QIs are expected to contribute considerably to improving ERCP quality in Korea. 
		                        		
		                        		
		                        		
		                        	
2.Quality Indicators of Endoscopic Retrograde Cholangiopancreatography in Korea
Ki-Hyun KIM ; Hyung Ku CHON ; Tae Jun SONG ; Dong Won AHN ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Tae Joo JEON ; Chang Hwan PARK ; Kwang Bum CHO ; Dong Wook LEE ; Jin-Seok PARK ; Seung Bae YOON ; Kwang Hyung CHUNG ; Jin JIN ; Miyoung CHOI
Korean Journal of Pancreas and Biliary Tract 2024;29(4):144-156
		                        		
		                        			
		                        			 Endoscopic retrograde cholangiopancreatography (ERCP) is a procedure that requires abundant clinical experience and endoscopic skills, and can lead to various complications, some of which may progress to life-threatening conditions. With expanding indications and technological advancements, ERCP is widely utilized, enhancing procedural accessibility. However, without proper quality management, the procedure can pose significant risks. Quality management in ERCP is essential to ensure safe and successful procedures and meet societal demands for improved healthcare competitiveness. To address these concerns, the Korean Pancreatobiliary Association has developed a Korean-specific ERCP quality indicator reflecting domestic medical environments and realities. Initially, based on a review of foreign ERCP quality indicators and related literatures, key questions were formulated for five preprocedural items, three intra-procedural items, and four post-procedural items. Descriptions and recommendations for each item were selected through peer evaluation. The developed Korean-specific ERCP quality indicator was reviewed by external experts based on the latest evidence and consensus in this fields. This Korean-specific indicator is expected to significantly contribute to improving ERCP quality in Korea, as it is tailored to local needs. 
		                        		
		                        		
		                        		
		                        	
3.Quality Indicators of Endoscopic Retrograde Cholangiopancreatography in Korea
Ki-Hyun KIM ; Hyung Ku CHON ; Tae Jun SONG ; Dong Won AHN ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Tae Joo JEON ; Chang Hwan PARK ; Kwang Bum CHO ; Dong Wook LEE ; Jin-Seok PARK ; Seung Bae YOON ; Kwang Hyung CHUNG ; Jin LEE ; Miyoung CHOI
The Korean Journal of Gastroenterology 2024;84(3):111-122
		                        		
		                        			
		                        			 Endoscopic retrograde cholangiopancreatography (ERCP) is a procedure that requires abundant clinical experience and endoscopic skills, and can lead to various complications, some of which may progress to life-threatening conditions. With expanding indications and technological advancements, ERCP is widely utilized, enhancing procedural accessibility. However, without proper quality management, the procedure can pose significant risks. Quality management in ERCP is essential to ensure safe and successful procedures and meet societal demands for improved healthcare competitiveness. To address these concerns, the Korean Society of Pancreatobiliary Endoscopy has developed a Korean-specific ERCP quality indicator reflecting domestic medical environments and realities. Initially, based on a review of foreign ERCP quality indicators and related literatures, key questions were formulated for five pre-procedural items, three intra-procedural items, and four post-procedural items. Descriptions and recommendations for each item were selected through peer evaluation. The developed Korean-specific ERCP quality indicator was reviewed by external experts based on the latest evidence and consensus in this fields. This Korean-specific indicator is expected to significantly contribute to improving ERCP quality in Korea, as it is tailored to local needs. 
		                        		
		                        		
		                        		
		                        	
4.National Survey Regarding the Management of Difficult Bile Duct Stones in South Korea
Yoon Suk LEE ; Tae Joo JEON ; Woo Hyun PAIK ; Dong-Won AHN ; Kwang Hyun CHUNG ; Byoung Kwan SON ; Tae Jun SONG ; Sung-Hoon MOON ; Eaum Seok LEE ; Jae Min LEE ; Seung Bae YOON ; Chang Nyol PAIK ; Yun Nah LEE ; Jin-Seok PARK ; Dong Wook LEE ; Sang Wook PARK ; Hyung Ku CHON ; Kwang Bum CHO ; Chang Hwan PARK ;
Gut and Liver 2023;17(3):475-481
		                        		
		                        			 Background/Aims:
		                        			This study aimed to investigate the patterns of preferred endoscopic procedure types and techniques for managing difficult common bile duct (CBD) stones in South Korea. 
		                        		
		                        			Methods:
		                        			The Committee of Policy and Quality Management of Korean Pancreatobiliary Association (KPBA) conducted a survey containing 19 questions. Both paper and online surveys were carried out; with the paper survey being conducted during the 2019 Annual Congress of KPBA and the online survey being conducted through Google Forms from April 2020 to February 2021. 
		                        		
		                        			Results:
		                        			The response rate was approximately 41.3% (86/208). Sixty-two (73.0%) worked at tertiary hospitals or academic medical centers, and 60 (69.7%) had more than 5 years of endoscopic retrograde cholangiopancreatography experience. The preferred size criteria for large CBD stones were 15 mm (40.6%), 20 mm (31.3%), and 30 mm (4.6%). For managing of large CBD stones, endoscopic papillary large balloon dilation after endoscopic sphincterotomy was the most preferred technique (74.4%). When performing procedures in those with bleeding diathesis, 64 (74.4%) respondents favored endoscopic papillary balloon dilation (EPBD) alone or EPBD with small endoscopic sphincterotomy. Fifty-five respondents (63.9%) preferred the doubleguidewire technique when faced with difficult bile duct cannulation in patients with periampullary diverticulum. In surgically altered anatomies, cap-fitted forward viewing endoscopy (76.7%) and percutaneous transhepatic cholangioscopy (48.8%) were the preferred techniques for Billroth-II anastomosis and total gastrectomy with Roux-en-Y anastomosis, respectively. 
		                        		
		                        			Conclusions
		                        			Most respondents showed unifying trends for the management of difficult CBD stones. The current practice patterns could be used as basic data for clinical quality improvements in the management of difficult CBD stones. 
		                        		
		                        		
		                        		
		                        	
5.Current Practice Patterns of Endoscopic Ultrasound-Guided Tissue Sampling for Pancreatic Solid Mass in Korea: Outcomes of a National Survey
Dong-Won AHN ; Hyung Ku CHON ; Sung-Hoon MOON ; Sang Wook PARK ; Woo Hyun PAIK ; Chang Nyol PAIK ; Byoung Kwan SON ; Tae Jun SONG ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Jae Min LEE ; Tae Joo JEON ; Chang Hwan PARK ; Kwang Bum CHO ; Dong Wook LEE ; Hong Ja KIM ; Seung Bae YOON ; Kwang Hyun CHUNG ; Jin-Seok PARK
Gut and Liver 2023;17(2):328-336
		                        		
		                        			 Background/Aims:
		                        			Although endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) and fine needle biopsy (FNB) are widely used for tissue acquisition of pancreatic solid mass, the optimal strategy of this procedure has not been established yet. The aim of this nationwide study was to investigate the current practice patterns of EUS-FNA/FNB for pancreatic solid mass in Korea. 
		                        		
		                        			Methods:
		                        			The Policy-Quality Management of the Korean Pancreatobiliary Association (KPBA) developed a questionnaire containing 22 questions. An electronic survey consisting of the questionnaire was distributed by e-mail to members registered to the KPBA. 
		                        		
		                        			Results:
		                        			A total of 101 respondents completed the survey. Eighty respondents (79.2%) performed preoperative EUS-FNA/FNB for operable pancreatic solid mass. Acquire needles (60.4%) were used the most, followed by ProCore needles (47.5%). In terms of need size, most respondents (>80%) preferred 22-gauge needles regardless of the location of the mass. Negative suction with a 10-mL syringe (71.3%) as sampling technique was followed by stylet slow-pull (41.6%). More than three needle passes for EUS-FNA/FNB was performed by most respondents (>80%). The frequency of requiring repeated procedure was significantly higher in respondents with a low individual volume (<5 per month, p=0.001). Prophylactic antibiotics were routinely used in 39 respondents (38.6%); rapid on-site pathologic evaluation was used in 6.1%. 
		                        		
		                        			Conclusions
		                        			According to this survey, practices of EUS-FNA/FNB for pancreatic solid mass varied substantially, some of which differed considerably from the recommendations present in existing guidelines. These results suggest that the development of evidence-based quality guidelines fitting Korean clinical practice is needed to establish the optimal strategy for this procedure. 
		                        		
		                        		
		                        		
		                        	
6.Endoscopist-Driven Sedation Practices in South Korea:Re-evaluation Considering the Nationwide Survey in 2019
Seon-Young PARK ; Jun Kyu LEE ; Chang-Hwan PARK ; Byung-Wook KIM ; Chang Kyun LEE ; Hong Jun PARK ; Byung Ik JANG ; Dong Uk KIM ; Jin Myung PARK ; Jae Min LEE ; Young Sin CHO ; Hyung Ku CHON ; Seung Young SEO ; Woo Hyun PAIK ; The Committees of Quality Management and Conscious Sedation of Korean Society of Gastrointestinal En
Gut and Liver 2022;16(6):899-906
		                        		
		                        			 Background/Aims:
		                        			This study aimed to determine changes in endoscopist-driven sedation practices 5 years after the first nationwide survey in 2014 by the Korean Society of Gastrointestinal Endoscopy (KSGE). 
		                        		
		                        			Methods:
		                        			A 59-item survey covering current practices was electronically mailed to all members of the KSGE in 2019. 
		                        		
		                        			Results:
		                        			In total, 955 (12.8%) out of 7,486 questionnaires were returned. A total of 738 (77.7%) out of 955 respondents attended dedicated sedation education programs. The American Society of Anesthesiologists class was recorded by 464 (51.2%) out of 907 respondents. The recording rate was higher in respondents who completed sedation education (p=0.014) and worked in general or tertiary hospitals (p<0.001). Compared to that reported in the previous survey, the reported use of propofol was higher in 2019. The respondents had higher satisfaction scores for propofol-based sedation compared with midazolam monotherapy (p<0.001). The rates of oxygen supplementation (p<0.001) and oxygen saturation level monitoring (p<0.001) during sedative endoscopy were higher in 2019 than in the previous survey. A total of 876 (98.4%) out of 890 respondents reported a separate recovery bay, and 615 (70.5%) out of 872 respondents reported that personnel were assigned solely to the recovery bay. 
		                        		
		                        			Conclusions
		                        			Endoscopist-driven sedation and monitoring practices in 2019 were significantly different than those in 2014. The respondents favored propofol-based sedation and utilized oxygen supplementation and monitoring of O2 saturation more frequently in 2019 than in 2014. 
		                        		
		                        		
		                        		
		                        	
8.Current trends in the management of pancreatic cystic neoplasms in Korea: a national survey
Hyung Ku CHON ; Sung Hoon MOON ; Sang Wook PARK ; Woo Hyun PAIK ; Chang Nyol PAIK ; Byoung Kwan SON ; Tae Jun SONG ; Dong Won AHN ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Jae Min LEE ; Tae Joo JEON ; Chang-Hwan PARK ; Kwang Bum CHO ; Dong Wook LEE
The Korean Journal of Internal Medicine 2022;37(1):63-72
		                        		
		                        			 Background/Aims:
		                        			The study aimed to investigate the current practice patterns in the management of pancreatic cystic neoplasms in Korea. 
		                        		
		                        			Methods:
		                        			An electronic survey was systematically distributed by email to members of the Korean Pancreatobiliary Association from December 2019 to February 2020. 
		                        		
		                        			Results:
		                        			In total, 115 (110 gastroenterologists, five surgeons) completed the survey, 72.2% of whom worked in a tertiary/academic medical center. Most (65.2%) followed the 2012/2017 International Association of Pancreatology guidelines for the management of pancreatic cystic neoplasms. A gadolinium-enhanced magnetic resonance imaging/magnetic resonance cholangiopancreatography was the most common first-line diagnostic modality (42.1%), but a contrast-enhanced computed tomography scan was preferred as a subsequent surveillance tool (58.3%). Seventy- four percent of respondents routinely performed endoscopic ultrasound-guided fine needle aspiration for pancreatic cystic neoplasms with suspicious mural nodules. Endoscopic ultrasound-guided fine needle aspiration cytology (94.8%) and cystic fluid carcinoembryonic antigen (95.7%) were used for cystic fluid analysis. Most (94%) typically recommended surgery in patients with high-risk stigmata, but 18.3% also considered proceeding with surgery in patients with worrisome features. Most (96.5%) would continue surveillance of pancreatic cystic neoplasms for more than 5 years. 
		                        		
		                        			Conclusions
		                        			According to this survey, there was variability in the management of pancreatic cystic neoplasms among the respondents. These results suggest that the development of evidence-based guidelines for pancreatic cystic neoplasms that fit the Korean practice is needed to create an optimal approach to the management of pancreatic cystic neoplasms. 
		                        		
		                        		
		                        		
		                        	
9.A National Survey on the Environment and Basic Techniques of Endoscopic Retrograde Cholangiopancreatography in Korea
Jae Min LEE ; Sung Hoon MOON ; Sang Wook PARK ; Woo Hyun PAIK ; Chang Nyol PAIK ; Byoung Kwan SON ; Tae Jun SONG ; Dong Won AHN ; Eaum Seok LEE ; Yun Nah LEE ; Yoon Suk LEE ; Tae Joo JEON ; Hyung Ku CHON ; Dong Wook LEE ; Chang Hwan PARK ; Kwang Bum CHO ; Committee of Policy-Quality Management ; Korean Pancreatobiliary Association
Gut and Liver 2021;15(6):904-911
		                        		
		                        			 Background/Aims:
		                        			The work environment in which endoscopic retrograde cholangiopancreatography (ERCP) is conducted has influence on its efficacy and safety. We aimed to assess the current status of ERCP work environments and to investigate the trends associated with the basic techniques of ERCP in Korea. 
		                        		
		                        			Methods:
		                        			The work environment and information on the basic techniques of ERCP were acquired by the Korean Pancreatobiliary Association (KPBA) through a national survey in 2019. The survey was performed at the KPBA conference in 2019. The contents of survey comprised of the current environment of ERCP, preparation before ERCP, and the preferred basic techniques used in ERCP. 
		                        		
		                        			Results:
		                        			Completed questionnaires were returned from 84 KPBA members. The mean ERCP volume per year was approximately 500. About 60% (50/84) reported that they worked with a dedicated ERCP team with experienced nurses. Two-thirds (57/84, 68%) answered that they had a fluoroscopy room used solely for ERCP procedures. All respondents intravenously hydrated the patient to prevent post-ERCP pancreatitis (84/84, 100%). The preferred procedural sedations were balanced propofol sedation (50%) and midazolam-only sedation (47%). Wire-guided cannulation was most commonly used for selective cannulation (81%). Endoscopic retrograde biliary drainage was preferred over endoscopic nasobiliary drainage (60% vs 22%). The initial method of ampullary intervention was endoscopic sphincterotomy in 60%. 
		                        		
		                        			Conclusions
		                        			Data from the survey involving a large number of Korean ERCP doctors revealed considerable variabilities with regard to the work environment and basic techniques of ERCP in Korea. The study provides information regarding the current trends of ERCP that can be used to establish ERCP standards in Korea. 
		                        		
		                        		
		                        		
		                        	
10.ERCP Room Setting: What Doctors Starting ERCP Need to Know
Eaum Seok LEE ; Hyung Ku CHON ; Ju Sang PARK ; Sun Young YI ; Dong Wook LEE ; Chang-Hwan PARK ; Kwang Bum CHO ;
Korean Journal of Pancreas and Biliary Tract 2021;26(2):67-76
		                        		
		                        			
		                        			To date, there is no standardization of the endoscopi c retrograde cholangiopancreatography (ERCP) room setting regarding with the size, equipment or space arrangement. Therefore, the authors visited 11 tertiary hospitals that recently remodeled or newly designed the ERCP room to analyze and identify their advantages and disadvantages. The ERCP room should have enough space for equipments including fluoroscopy, endoscopy, electrosurgical unit, preparation table and for patient movement. The EUS room does not require an independent space unless it is a very large scale hospital, and the ERCP room can be shared. Considering the pros and cons of each equipment, adequate fluoroscopic device should be selected depending on the hospital circumstance. Expensive equipment for X-ray fluoroscopy system is not necessarily good, and it is necessary to install equipment suitable for each hospital situation by understanding the advantages and disadvantages of fluoroscopy. For prevention of ERCP-related radiation hazard, both endoscopist and assistants should wear radiation-blocking apron, thyroid protectors, and lead glasses. Furthermore, a shield that can block radiation between the endoscopist and the patient should be installed to protect high-energy scattered waves. One-way direction should be designed to prevent cross infection when moving the endoscopic equipment from the ERCP to the cleaning room. If possible, it is recommended to keep a cardiopulmonary resuscitation cart in the ERCP room.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail