1.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
2.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
3.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
4.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
5.Validation of Devices for the Five Times Sit To Stand Test:Comparing Plantar Pressure and Head Motion Analysis with Manual Measurement
Sanghyun JEE ; Chan Woong JANG ; Kyoungmin PARK ; Sanghoon SHIN ; Min-Chul PAEK ; Jung Hyun PARK
Yonsei Medical Journal 2025;66(1):51-57
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials and Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants’ mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
6.Evaluation of the Efficacy and Safety of DW1903 in Patients with Gastritis: A Randomized, Double-Blind, Noninferiority, Multicenter, Phase 3 study
Jie-Hyun KIM ; Hwoon-Yong JUNG ; In Kyung YOO ; Seon-Young PARK ; Jae Gyu KIM ; Jae Kyu SUNG ; Jin Seok JANG ; Gab Jin CHEON ; Kyoung Oh KIM ; Tae Oh KIM ; Soo Teik LEE ; Kwang Bum CHO ; Hoon Jai CHUN ; Jong-Jae PARK ; Moo In PARK ; Jae-Young JANG ; Seong Woo JEON ; Jin Woong CHO ; Dae Hwan KANG ; Gwang Ha KIM ; Jae J. KIM ; Sang Gyun KIM ; Nayoung KIM ; Yong Chan LEE ; Su Jin HONG ; Hyun-Soo KIM ; Sora LEE ; Sang Woo LEE
Gut and Liver 2024;18(1):70-76
Background/Aims:
H2 receptor antagonists (H2RA) have been used to treat gastritis by inhibiting gastric acid. Proton pump inhibitors (PPIs) are more potent acid suppressants than H2RA.However, the efficacy and safety of low-dose PPI for treating gastritis remain unclear. The aim was to investigate the efficacy and safety of low-dose PPI for treating gastritis.
Methods:
A double-blind, noninferiority, multicenter, phase 3 clinical trial randomly assigned 476 patients with endoscopic erosive gastritis to a group using esomeprazole 10 mg (DW1903) daily and a group using famotidine 20 mg (DW1903R1) daily for 2 weeks. The full-analysis set included 319 patients (DW1903, n=159; DW1903R1, n=160) and the per-protocol set included 298 patients (DW1903, n=147; DW1903R1, n=151). The primary endpoint (erosion improvement rate) and secondary endpoint (erosion and edema cure rates, improvement rates of hemorrhage, erythema, and symptoms) were assessed after the treatment. Adverse events were compared.
Results:
According to the full-analysis set, the erosion improvement rates in the DW1903 and DW1903R1 groups were 59.8% and 58.8%, respectively. According to the per-protocol analysis, the erosion improvement rates in the DW1903 and DW1903R1 groups were 61.9% and 59.6%, respectively. Secondary endpoints were not significantly different between two groups except that the hemorrhagic improvement rate was higher in DW1903 with statistical tendency. The number of adverse events were not statistically different.
Conclusions
DW1903 of a low-dose PPI was not inferior to DW1903R1 of H2RA. Thus, lowdose PPI can be a novel option for treating gastritis (ClinicalTrials.gov Identifier: NCT05163756).
7.Lower Atrial Fibrillation Risk With Sodium-Glucose Cotransporter 2Inhibitors Than With Dipeptidyl Peptidase-4 Inhibitors in Individuals With Type 2 Diabetes: A Nationwide Cohort Study
Min KIM ; Kyoung Hwa HA ; Junyoung LEE ; Sangshin PARK ; Kyeong Seok OH ; Dae-Hwan BAE ; Ju Hee LEE ; Sang Min KIM ; Woong Gil CHOI ; Kyung-Kuk HWANG ; Dong-Woon KIM ; Myeong-Chan CHO ; Dae Jung KIM ; Jang-Whan BAE
Korean Circulation Journal 2024;54(5):256-267
Background and Objectives:
Accumulating evidence shows that sodium-glucose cotransporter 2 inhibitors (SGLT2is) reduce adverse cardiovascular outcomes. However, whether SGLT2i, compared with other antidiabetic drugs, reduce the new development of atrial fibrillation (AF) is unclear. In this study, we compared SGLT2i with dipeptidyl peptidase-4 inhibitors (DPP-4is) in terms of reduction in the risk of AF in individuals with type 2 diabetes.
Methods:
We included 42,786 propensity score-matched pairs of SGLT2i and DPP-4i users without previous AF diagnosis using the Korean National Health Insurance Service database between May 1, 2016, and December 31, 2018.
Results:
During a median follow-up of 1.3 years, SGLT2i users had a lower incidence of AF than DPP-4i users (1.95 vs. 2.65 per 1,000 person-years; hazard ratio [HR], 0.73; 95% confidence interval [CI], 0.55–0.97; p=0.028]). In individuals without heart failure, SGLT2i users was associated with a decreased risk of AF incidence (HR, 0.70; 95% CI, 0.52–0.94; p=0.019) compared to DPP-4i users. However, individuals with heart failure, SGLT2i users was not significantly associated with a change in risk (HR, 1.04; 95% CI, 0.44–2.44; p=0.936).
Conclusions
In this nationwide cohort study of individuals with type 2 diabetes, treatment with SGLT2i was associated with a lower risk of AF compared with treatment with DPP-4i.
8.Position Statement: Atypical Femoral Fracture from the Korean Society for Bone and Mineral Research in 2023
Jae-Hwi NHO ; Byung-Woong JANG ; Dong Woo LEE ; Jae-Hyun KIM ; Tae Kang LIM ; Soo Min CHA ; Dong-Kyo SEO ; Yong-Geun PARK ; Dong-Geun KANG ; Young-Kyun LEE ; Yong-Chan HA
Journal of Bone Metabolism 2023;30(3):209-217
As the aging population increases, the number of patients with osteoporosis is gradually rising. Osteoporosis is a metabolic bone disease characterized by low bone mass and the microarchitectural deterioration of bone tissue, resulting in reduced bone strength and an increased risk of low-energy or fragility fractures. Thus, the use of anti-resorptive agents, such as bisphosphonates (BPs), to prevent osteoporotic fractures is growing annually. BPs are effective in reducing hip and other fractures. However, the longer a patient takes BPs, the higher the risk of an atypical femoral fracture (AFF). The exact mechanism by which long-term BP use affects the development of AFFs has not yet been clarified. However, several theories have been suggested to explain the pathogenesis of AFFs, such as suppressed bone remodeling, impaired bone healing, altered bone quality, and femoral morphology. The management of AFFs requires both medical and surgical approaches. BPs therapy should be discontinued immediately, and calcium and vitamin D levels should be evaluated and supplemented if insufficient. Teriparatide can be used for AFFs. Intramedullary nailing is the primary treatment for complete AFFs, and prophylactic femoral nailing is recommended if signs of an impending fracture are detected.
9.Evaluation of the Surgical Margin Threshold for Avoiding Recurrence after Partial Nephrectomy in Patients with Renal Cell Carcinoma
Jongsoo LEE ; Jinu KIM ; Jong Chan KIM ; Won Sik HAM ; Woong Kyu HAN ; Koon Ho RHA ; Young Deuk CHOI ; Won Sik JANG
Yonsei Medical Journal 2022;63(2):173-178
Purpose:
An adequate minimal surgical margin for partial nephrectomy (PN) has not yet been conclusively established. Therefore, we aimed to compare PN recurrence rates according to surgical margin status and to establish an adequate minimal surgical margin.
Materials and Methods:
We retrospectively studied patients with clinically localized renal cell carcinoma who underwent PN between 2005 and 2014. Surgical margin width (SMW) was assessed for all surgical tissues and divided into three groups: SMW <1 mm, SMW ≥1 mm, and positive surgical margin (PSM). The data were analyzed using the Kaplan-Meier method with log-rank tests and multivariate Cox regression models.
Results:
Of 748 patients (median age, 55 years; interquartile range, 46–64 years; 220 female), 704 (94.2%) and 44 (5.8%) patients had negative and PSMs, respectively. Recurrence-free survival was significantly lower in patients with PSMs (p<0.001) and was not significantly different between SMW ≥1 mm and <1 mm groups (p=0.604). PSM was a significant predictor of recurrence (hazard ratio: 8.03, 95% confidence interval: 2.74–23.56, p<0.001), in contrast to SMW <1 mm (p=0.680).
Conclusion
A PSM after PN significantly increases the risk of recurrence. We discovered that even a submillimeter safety surgical margin may be enough to prevent recurrence. To maximize normal renal parenchyma preservation and to avoid cancer recurrence in renal parenchymal tumor patients, PN may be a safe treatment, except for those with a PSM in the final pathology.
10.External validation of risk prediction platforms for pancreatic fistula after pancreatoduodenectomy using nomograms and artificial intelligence
So Jeong YOON ; Wooil KWON ; Ok Joo LEE ; Ji Hye JUNG ; Yong Chan SHIN ; Chang-Sup LIM ; Hongbeom KIM ; Jin-Young JANG ; Sang Hyun SHIN ; Jin Seok HEO ; In Woong HAN
Annals of Surgical Treatment and Research 2022;102(3):147-152
Purpose:
Postoperative pancreatic fistula (POPF) is a life-threatening complication following pancreatoduodenectomy (PD).We previously developed nomogram- and artificial intelligence (AI)-based risk prediction platforms for POPF after PD. This study aims to externally validate these platforms.
Methods:
Between January 2007 and December 2016, a total of 1,576 patients who underwent PD in Seoul National University Hospital, Ilsan Paik Hospital, and Boramae Medical Center were retrospectively reviewed. The individual risk scores for POPF were calculated using each platform by Samsung Medical Center. The predictive ability was evaluated using a receiver operating characteristic curve and the area under the curve (AUC). The optimal predictive value was obtained via backward elimination in accordance with the results from the AI development process.
Results:
The AUC of the nomogram after external validation was 0.679 (P < 0.001). The values of AUC after backward elimination in the AI model varied from 0.585 to 0.672. A total of 13 risk factors represented the maximal AUC of 0.672 (P < 0.001).
Conclusion
We performed external validation of previously developed platforms for predicting POPF. Further research is needed to investigate other potential risk factors and thereby improve the predictability of the platform.

Result Analysis
Print
Save
E-mail