1.Treatment Outcomes and Prognostic Factors of Intracranial Germ Cell Tumors: A Single Institution Retrospective Study
Eunjong LEE ; Kihwan HWANG ; Kyeong-O GO ; Jung Ho HAN ; Hyoung Soo CHOI ; Yu Jung KIM ; Byung Se CHOI ; In Ah KIM ; Gheeyoung CHOE ; Chae-Yong KIM
Brain Tumor Research and Treatment 2025;13(2):45-52
Background:
This study analyzed the epidemiology and treatment outcomes of germ cell tumorpatients at a single institution.
Methods:
A retrospective analysis was conducted on intracranial germ cell tumor (iGCT) pa-tients treated at a single tertiary hospital from 2004 to 2019. Patients were categorized based on treatment modality: Korean Society for Pediatric Neuro-Oncology (KSPNO) protocol or bleomycin, etoposide, and cisplatin with radiation therapy.
Results:
Forty-nine iGCT patients treated with combined chemotherapy and radiotherapywere analyzed. The median age was 19 years (range: 6–40), with a median follow-up duration of 148.0 months (range: 10.5–265.5). Tumors were most common in the pineal gland (51.0%). Although no significant differences in outcomes were observed between treatment modalities, outcomes varied significantly by pathological type. The 10-year progression-free survival rates for germinoma and non-germinomatous germ cell tumors (NGGCTs) were 88.1% and 32.7%, respectively (p=0.003), while the 10-year overall survival rates were 92.9% and 67.5%, respectively (p<0.001). Fourteen patients experienced CTCAE (Common Terminology Criteria for Adverse Events) grade ≥3 adverse events, with one eventrelated death.
Conclusion
Pure germinoma demonstrated higher survival and lower recurrence rates comparedto NGGCT. The KSPNO protocol appears to be an acceptable and safe treatment option for iGCT patients. Further multi-institutional studies with larger cohorts are warranted.
2.Treatment Outcomes and Prognostic Factors of Intracranial Germ Cell Tumors: A Single Institution Retrospective Study
Eunjong LEE ; Kihwan HWANG ; Kyeong-O GO ; Jung Ho HAN ; Hyoung Soo CHOI ; Yu Jung KIM ; Byung Se CHOI ; In Ah KIM ; Gheeyoung CHOE ; Chae-Yong KIM
Brain Tumor Research and Treatment 2025;13(2):45-52
Background:
This study analyzed the epidemiology and treatment outcomes of germ cell tumorpatients at a single institution.
Methods:
A retrospective analysis was conducted on intracranial germ cell tumor (iGCT) pa-tients treated at a single tertiary hospital from 2004 to 2019. Patients were categorized based on treatment modality: Korean Society for Pediatric Neuro-Oncology (KSPNO) protocol or bleomycin, etoposide, and cisplatin with radiation therapy.
Results:
Forty-nine iGCT patients treated with combined chemotherapy and radiotherapywere analyzed. The median age was 19 years (range: 6–40), with a median follow-up duration of 148.0 months (range: 10.5–265.5). Tumors were most common in the pineal gland (51.0%). Although no significant differences in outcomes were observed between treatment modalities, outcomes varied significantly by pathological type. The 10-year progression-free survival rates for germinoma and non-germinomatous germ cell tumors (NGGCTs) were 88.1% and 32.7%, respectively (p=0.003), while the 10-year overall survival rates were 92.9% and 67.5%, respectively (p<0.001). Fourteen patients experienced CTCAE (Common Terminology Criteria for Adverse Events) grade ≥3 adverse events, with one eventrelated death.
Conclusion
Pure germinoma demonstrated higher survival and lower recurrence rates comparedto NGGCT. The KSPNO protocol appears to be an acceptable and safe treatment option for iGCT patients. Further multi-institutional studies with larger cohorts are warranted.
3.Treatment Outcomes and Prognostic Factors of Intracranial Germ Cell Tumors: A Single Institution Retrospective Study
Eunjong LEE ; Kihwan HWANG ; Kyeong-O GO ; Jung Ho HAN ; Hyoung Soo CHOI ; Yu Jung KIM ; Byung Se CHOI ; In Ah KIM ; Gheeyoung CHOE ; Chae-Yong KIM
Brain Tumor Research and Treatment 2025;13(2):45-52
Background:
This study analyzed the epidemiology and treatment outcomes of germ cell tumorpatients at a single institution.
Methods:
A retrospective analysis was conducted on intracranial germ cell tumor (iGCT) pa-tients treated at a single tertiary hospital from 2004 to 2019. Patients were categorized based on treatment modality: Korean Society for Pediatric Neuro-Oncology (KSPNO) protocol or bleomycin, etoposide, and cisplatin with radiation therapy.
Results:
Forty-nine iGCT patients treated with combined chemotherapy and radiotherapywere analyzed. The median age was 19 years (range: 6–40), with a median follow-up duration of 148.0 months (range: 10.5–265.5). Tumors were most common in the pineal gland (51.0%). Although no significant differences in outcomes were observed between treatment modalities, outcomes varied significantly by pathological type. The 10-year progression-free survival rates for germinoma and non-germinomatous germ cell tumors (NGGCTs) were 88.1% and 32.7%, respectively (p=0.003), while the 10-year overall survival rates were 92.9% and 67.5%, respectively (p<0.001). Fourteen patients experienced CTCAE (Common Terminology Criteria for Adverse Events) grade ≥3 adverse events, with one eventrelated death.
Conclusion
Pure germinoma demonstrated higher survival and lower recurrence rates comparedto NGGCT. The KSPNO protocol appears to be an acceptable and safe treatment option for iGCT patients. Further multi-institutional studies with larger cohorts are warranted.
4.Catheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Yong Chae JUNG ; Man-shik SHIM ; Hee Sun PARK ; Min-Woong KANG
Acute and Critical Care 2024;39(2):266-274
Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement. Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications. Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI; 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively. Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
5.Catheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Yong Chae JUNG ; Man-shik SHIM ; Hee Sun PARK ; Min-Woong KANG
Acute and Critical Care 2024;39(2):266-274
Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement. Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications. Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI; 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively. Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
6.Catheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Yong Chae JUNG ; Man-shik SHIM ; Hee Sun PARK ; Min-Woong KANG
Acute and Critical Care 2024;39(2):266-274
Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement. Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications. Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI; 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively. Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
7.Catheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Yong Chae JUNG ; Man-shik SHIM ; Hee Sun PARK ; Min-Woong KANG
Acute and Critical Care 2024;39(2):266-274
Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement. Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications. Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI; 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively. Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
9.Pharmacological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Jisu SUN ; Hye Kyung CHUNG ; Yong Jin LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):185-199
Thyroid scanning using technetium-99m ( 99mTc) is the gold standard for diagnosing feline hyperthyroidism. In cats with an overactive thyroid, a thyroid scan is the most appropriate imaging technique to detect and localize any hyperfunctional adenomatous thyroid tissue. In this study, the pharmacological properties of the Technekitty injection (Tc-99m), developed as a diagnostic agent for feline hyperthyroidism using 99mTc as an active ingredient, were tested in FRTL-5 thyroid follicular cell line and ICR mice. The percentage of cell uptake of the Tc-99m in FRTL-5 thyroid cells was 0.182 ± 0.018%, which was about 6 times higher compared to Clone 9 hepatocytes. This uptake decreased by 38.2% due to competitive inhibition by iodine (sodium iodide). In tissue distribution tests by using ICR mice, the highest distribution was observed in the liver, kidneys, spleen, lungs, and femur at 0.083 hours after administration, and this distribution decreased as the compound was excreted through the kidneys, the pri-mary excretory organ. Maximum distribution was confirmed at 1 hour in the small intestine, 6hours in the large intestine, and 2 hours in the thyroid gland. Additionally, the total amount excreted through urine and feces over 48 hours (2 days) was 78.80% of the injected dose, with 37.70% (47.84% of the total excretion) excreted through urine and 41.10% (52.16% of the total excretion) through feces. In conclusion, the Tc-99m has the same mechanism of action, potency, absorption, distribution, metabolism, and excretion characteristics as 99mTc used for feline hyperthyroidism in the United States, Europe, and other countries, because the Technekitty injection (Tc-99m) contains 99mTc as its sole active ingredient. Based on these results, the Technekitty injection (Tc-99m) is expected to be safely used in the clinical diagnosis of feline hyperthyroidism.
10.Evaluating the Accuracy of Artificial Intelligence-Based Chatbots on Pediatric Dentistry Questions in the Korean National Dental Board Exam
Yun Sun JUNG ; Yong Kwon CHAE ; Mi Sun KIM ; Hyo-Seol LEE ; Sung Chul CHOI ; Ok Hyung NAM
Journal of Korean Academy of Pediatric Dentistry 2024;51(3):299-309
This study aimed to assess the competency of artificial intelligence (AI) in pediatric dentistry and compare it with that of dentists. We used open-source data obtained from the Korea Health Personnel Licensing Examination Institute. A total of 32 item multiple-choice pediatric dentistry exam questions were included. Two AI-based chatbots (ChatGPT 3.5 and Gemini) were evaluated. Each chatbot received the same questions seven times in separate chat sessions initiated on April 25, 2024. The accuracy was assessed by measuring the percentage of correct answers, and consistency was evaluated using Cronbach’s alpha coefficient. Both ChatGPT 3.5 and Gemini demonstrated similar accuracy, with no significant differences observed between them. However, neither chatbot achieved the minimum passing score set by the Pediatric Dentistry National Examination. However, both chatbots exhibited acceptable consistency in their responses. Within the limits of this study, both AI-based chatbots did not sufficiently answer the pediatric dentistry exam questions. This finding suggests that pediatric dentists should be aware of the advantages and limitations of this new tool and effectively utilize it to promote patient health.

Result Analysis
Print
Save
E-mail