1.Three-dimensional finite element stress analysis of surface-mounted inlays in repairing pulp-penetrating non-carious cervical lesion of maxillary first premolar.
West China Journal of Stomatology 2023;41(5):541-553
OBJECTIVES:
This study aimed to explore the stress distribution of surface-mounted inlays with two ceramic materials and different strategies for fiber post-restoration on pulp-penetrating non-carious cervical lesion in a maxillary first premolar to provide minimally invasive and reasonable restorative methods.
METHODS:
The cone beam computed tomography data of the standard right upper first premolar were selected. Healthy control (HC) and defective control (DC) finite element models were established. Then, eight experimental models were established according to two different ceramic materials (IPS e.max CAD [LD] and Lava Ultimate [LU]) and different locations of fiber post (without fiber post [NP], fiber post in buccal root canal [B], fiber post in palatal root canal [P], fiber post in both root canals [BP]), namely, LDNP, LDB, LDP, LDBP, LUNP, LUB, LUP, and LUBP. Axial load F1 and lateral load F2 were applied. Maximum principal stress and displacement of the buccal tip were investigated using finite element analysis software. Then, the percentage change of the following indicators in each experimental group was analyzed: stress of defective tip with group DC, stress of enamel and dentine, and displacement of buccal tips with group HC. It was considered similar when the percentage change was less than 5%.
RESULTS:
LD and LU groups could effectively reduce the stress of the defective tip, but the decreasing amplitude in the former was greater than that of the latter. For the stress of surface-mounted inlays and resin adhesive layer, LD groups were higher than LU groups, and no significant difference in stress peak was found among different experimental groups in the same material. In addition, fiber posts in double root canals could significantly reduce buccal tip displacement.
CONCLUSIONS
For pulp-penetrating non-carious cervical lesions, the restorative strategy of surface-mounted inlays could be applied. Compared with Lava Ultimate, IPS e.max CAD could better protect the defective tip tooth. Furthermore, fiber posts in double root canals could decrease overall deformation and increase the retention of surface-mounted inlays.
Inlays
;
Finite Element Analysis
;
Composite Resins
;
Bicuspid
;
Ceramics
;
Dental Stress Analysis
2.The removal of three kinds of occlusal veneers by Er: Yag laser.
Jianyu ZHU ; Feifei HONG ; Lianghang HE ; Wei WEN ; Xianlin LEI ; Zhisheng ZHANG ; Lu YIN
West China Journal of Stomatology 2023;41(5):568-572
OBJECTIVES:
This study aimed to remove occlusal veneers of varied thicknesses and compositions by Er:Yag laser in vitro and analyze the interfacial microstructure between veneers and tooth that irradiated by laser, by which experimental evidence could be provided to support the non-invasive removal of occlusal veneerby laser.
METHODS:
Fresh mandibular premolars extracted for orthodontic requirements were collected for tooth preparation. Three kinds of ceramic materials (Vita Suprinity, Vita Mark Ⅱ, and Upcera Hyramic) were selected to fabricate occlusal veneer with different thicknesses (1.0, 1.5, and 2.0 mm). One week later, Er:Yag laser (2.5 W and 3.5 W) was used to irradiate and remove the occlusal veneer and recorded the timespan. After the removal operation, the micro-morphologies of samples were examined by scanning electron microscope.
RESULTS:
Upcera Hyramic veneer failed to be removed (>20 min); the operation span at 2.5 W, Vita Suprinity (96.0 s±16.0 s) was longer than Vita MarkⅡ(84.5 s±19.5 s) in the 1.0 mm group (P<0.05), and Vita Suprinity (246.5 s±13.5 s) was longer than Vita MarkⅡ(170.0 s±14.0 s) in the 1.5 mm group (P<0.05). At 3.5 W, Vita Suprinity (381.0 s±24.0 s) was longer than Vita MarkⅡ(341.5 s±26.5 s) in the 2.0 mm group.
CONCLUSIONS
Increasing laser power could shorten the operation span and facilitate the removal of occlusal veneers with the same thickness and composition. The occlusal veneer was sustained when insufficient laser power was applied. With the same laser power and ceramic thickness, laser penetration could interfere with the integral of the ceramic structure when the laser interacted with the bonding layer. With the same ceramic composition and laser power, the operation span and laser power increased with the thickness of the occlusal veneer. However, the laser was incapable of removing occlusal resin veneer directly.
Lasers, Solid-State
;
Materials Testing
;
Dental Porcelain/chemistry*
;
Ceramics/chemistry*
;
Bicuspid
;
Dental Veneers
3.Preparation and properties of silica/hydroxyapatite whiskers porous ceramics scaffold.
Yuxi WAN ; Qiangguo CHEN ; Tingting YAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1142-1148
OBJECTIVE:
To investigate the preparation and properties of the novel silica (SiO 2)/hydroxyapatite (HAP) whiskers porous ceramics scaffold.
METHODS:
The HAP whiskers were modified by the SiO 2 microspheres using the Stöber method. Three types of SiO 2/HAP whiskers were fabricated under different factors (for the No.1 samples, the content of tetraethoxysilane, stirring time, calcination temperature, and soaking time were 10 mL, 12 hours, 560℃, and 0.5 hours, respectively; and in the No.2 samples, those were 15 mL, 24 hours, 650℃, and 2 hours, respectively; while those in the No.3 samples were 20 mL, 48 hours, 750℃, and 4 hours, respectively). The phase and morphology of the self-made HAP whisker and 3 types of SiO 2/HAP whiskers were detected by the X-ray diffraction analysis and scanning electron microscopy. Taken the self-made HAP whisker and 3 types of SiO 2/HAP whiskers as raw materials, various porous ceramic materials were prepared using the mechanical foaming method combined with extrusion molding method, and the low-temperature heat treatment. The pore structure of porous ceramics was observed by scanning electron microscopy. Its porosity and pore size distribution were measured. And further the axial compressive strength was measured, and the biodegradability was detected by simulated body fluid. Cell counting kit 8 method was used to conduct cytotoxicity experiments on the extract of porous ceramics.
RESULTS:
The SiO 2 microspheres modified HAP whiskers and its porous ceramic materials were prepared successfully, respectively. In the SiO 2/HAP whiskers, the amorphous SiO 2 microspheres with a diameter of 200 nm, uniform distribution and good adhesion were attached to the surface of the whiskers, and the number of microspheres was controllable. The apparent porosity of the porous ceramic scaffold was about 78%, and its pore structure was composed of neatly arranged longitudinal through-holes and a large number of micro/nano through-holes. Compared with HAP whisker porous ceramic, the axial compressive strength of the SiO 2/HAP whisker porous ceramics could reach 1.0 MPa, which increased the strength by nearly 4 times. Among them, the axial compressive strength of the No.2 SiO 2/HAP whisker porous ceramic was the highest. The SiO 2 microspheres attached to the surface of the whiskers could provide sites for the deposition of apatite. With the content of SiO 2 microspheres increased, the deposition rate of apatite accelerated. The cytotoxicity level of the prepared porous ceramics ranged from 0 to 1, without cytotoxicity.
CONCLUSION
SiO 2/HAP whisker porous ceramics have good biological activity, high porosity, three-dimensional complex pore structure, good axial compressive strength, and no cytotoxicity, which make it a promising scaffold material for bone tissue engineering.
Animals
;
Durapatite
;
Porosity
;
Vibrissae
;
Apatites
;
Ceramics
;
Silicon Dioxide
4.Status of 3D Printing Technology for Preparing Bioceramic Materials.
Jun ZHANG ; Mingli LI ; Bincai TANG ; Han DONG ; Qiong YU
Chinese Journal of Medical Instrumentation 2023;47(6):651-658
3D printing technology has great advantages in small batch and personalized customization, so it has attracted much attention in the biomedical field. The consumables available for 3D printing include polymer, metal, ceramic and derived materials. Biomedical ceramics, with high melting point and poor toughness, are the most difficult materials to be used in 3D printing. The progress of 3D printing ceramic preparation process using ceramic powder, ceramic slurry, ceramic wire, ceramic film and other different raw materials as consumables are reviewed, and the surface roughness, size, density and other parameters of ceramics prepared by SLS, 3DP, DIW, IJP, SL, DLP, FDM, LOM and other different processes are compared. The study also summarizes the clinical application status of 3D printed bioceramics in the field of hard tissue repair such as bone tissue engineering scaffolds and dental prostheses. The SL ceramic additive manufacturing technology based on the principle of UV polymerization has better manufacturing precision, forming quality and the ability to prepare large-size parts, and can also endow bioceramics with better biological properties, mechanical properties, antibacterial, tumor treatment and other functions by doping trace nutrients and surface functional modification. Compared with the traditional subtractive manufacturing process, the bioceramics prepared by 3D printing not only have good mechanical properties, but also often have better biocompatibility and osteoconductivity.
Bone and Bones
;
Ceramics
;
Printing, Three-Dimensional
;
Tissue Engineering
;
Tissue Scaffolds
5.Design of a New Type of Electrochemical Ceramic Membrane Oxygen Production System.
Qiaosheng YU ; Sen YANG ; Guoqi CHEN ; Xiao LI
Chinese Journal of Medical Instrumentation 2023;47(3):284-287
OBJECTIVE:
In order to solve the problem that the existing oxygen production technology cannot simultaneously produce pure oxygen, high-purity oxygen, ultra-pure oxygen, and the modular expansion of oxygen production capacity, a new type of electrochemical ceramic membrane oxygen production system was discussed and developed.
METHODS:
Through the design of the ceramic membrane stack, airflow distributor, heater, double spiral exchanger, thermal insulation sleeve, control panel, control box and auxiliary system in the electrochemical ceramic membrane oxygen generator, a modular oxygen production system is formed.
RESULTS:
The modular design can produce pure oxygen, high-purity oxygen and ultra-pure oxygen to meet various oxygen consumption needs.
CONCLUSIONS
The electrochemical ceramic membrane oxygen production system is a new type of oxygen production technology. The main components have no moving parts, no noise, and no pollution. It can produce pure oxygen, high-purity oxygen and ultra-pure oxygen on site, with small size, light weight, and module combination which is suitable for convenient expansion and installation of oxygen consumption.
Oxygen
;
Ceramics
;
Technology
6.Study on the correlation between ceramic and chronic obstructive pulmonary disease in Foshan City.
Li Xian ZHENG ; Wen Guang YOU ; Yu Huan ZHAO ; Ai Hua ZHU ; Li Hua LIANG ; Ge Ting CHEN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2023;41(2):126-129
Objective: To study the correlation between ceramic and chronic obstructive pulmonary disease (COPD), and explore its related risk factors. Methods: In January 2021, five representative ceramic enterprises were selected from Chancheng District, Nanhai District, Gaoming District and Sanshui District of Foshan City. The ceramic workers who came to Chancheng Hospital of Foshan First People's Hospital for physical examination from January to October 2021 were selected as the research objects, and 525 people were included. Conduct questionnaire survey and pulmonary function test. Logistic regresion was performed to analyze the influencing facters of COPD among ceramic workers. Results: The subjects were (38.51±1.25) years old, 328 males and 197 females, and the detection rate of COPD was 9.52% (50/525). The incidence of respiratory symptoms such as dyspnea, chronic cough, wheezing and chest tightness, the detection rates of abnormal lung age, abnormal lung function and COPD in males were higher than those in females (P<0.05). The logistic regression analysis showed that male, age, working years, smoking status and family history of COPD were the risk factors for COPD among ceramic workers (P<0.05) . Conclusion: The ceramic workers are the high risk population of COPD. We should do a good job in health education, and do a regular physical examination to find the changes of lung function in time, and prevent the occurrence of COPD as soon as possible.
Female
;
Humans
;
Male
;
Adult
;
Pulmonary Disease, Chronic Obstructive/epidemiology*
;
Ceramics
;
Health Education
;
Hospitals
;
Physical Examination
7.Meta-analysis of different joint interfaces in total hip arthroplasty under long-term follow-up.
Gai-Ge WU ; Ling-An HUANG ; Li GUO ; Peng-Cui LI ; Xiao-Chun WEI
China Journal of Orthopaedics and Traumatology 2023;36(2):165-171
OBJECTIVE:
To compare the long-term follow-up effect and complications of ceramic on ceramic (CoC) interface and ceramic on polyethyleneon ceramic (CoP) interface in primary total hip arthroplasty, and provide clinical evidence.
METHODS:
Search PubMed, EMBase, the CoChrane Library databases, Web of science, Wanfang database, and CNKI from January 2000 to September 2021, screening and inclusion of randomized controlled trials (RCTs) comparing the long-term efficacy and complications of CoC interface and CoP interface in total hip arthroplasty. Literature screening, quality evaluation and data extraction were carried out according to the inclusion and exclusion criteria, using Review Manager 5.3 statistical software. The software was used to perform statistical analysis on joint function, revision, prosthesis fracture, abnormal joint noise, and prosthesis wear rate after CoC or CoP.
RESULTS:
Seven RCTs studies were included, including 390 cases of hips with CoC artificial joints and 384 cases of hips with CoP artificial joints. The long-term joint function improvement of CoC and CoP artificial joints was similar and there was no significant differences, with an average difference was MD=0.63, 95%CI=(-1.81, 3.07), P=0.61. About the postoperative complications, CoC artificial joints have higher incidence rate of abnormal joint noise, with odds ratio (OR)=11.05, 95%CI=(2.04, 59.84), P=0.005. CoP artificial joints wear faster, with an average MD=-87.11, 95%CI=(-114.40, -59.82), P<0.000 1. There was no significant difference between the two groups in the replacement-related complications such as joint dislocation, prosthesis loosening, osteolysis, and the rate of prosthesis revision caused by various reasons.
CONCLUSION
The clinical function results and complications of CoC artificial joints are comparable to those of CoP artificial joints. Although CoP artificial joint prosthesis has a faster wear rate, it does not affect joint function and increase complications, and there is no abnormal joint noise. CoC is expensive and the long-term efficacy is equivalent to CoP. Clinicians should consider cost performance when choosing CoC.
Humans
;
Arthroplasty, Replacement, Hip/methods*
;
Hip Prosthesis
;
Follow-Up Studies
;
Prosthesis Design
;
Polyethylene
;
Prosthesis Failure
;
Reoperation
;
Ceramics
;
Treatment Outcome
8.Research on friction and wear behaviors of silicon-lithium spray coating on zirconia ceramics.
Wei Wei LI ; Hu CHEN ; Yong WANG ; Yu Chun SUN
Journal of Peking University(Health Sciences) 2023;55(1):94-100
OBJECTIVE:
To study microstructure, friction and wear behaviors of silicon-lithium spray coating on the surface of zirconia ceramics and to preliminarily evaluate its esthetic so as to provide support and guidance for the clinical application.
METHODS:
Zirconia ceramic specimens were randomly divided into three groups: coating group (two subgroups), polishing group (two subgroups), and glazing group (four subgroups), with 10 samples in each subgroup. The two subgroups of coating group were the zirconia ceramics with the untreated and preliminary polishing surfaces sprayed with silicon-lithium coating, respectively. The two subgroups of polishing group were preliminary polishing and fine polishing of zirconia ceramics, respectively. The four subgroups of glazing group were preliminarily polished zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively; and untreated zirconia ceramics glazed with Biomic and Stain/Glaze products, respectively. The above 8 subgroups of zirconia ceramic specimens were used as friction pairs with 80 steatite ceramics for 50 000 chewing cycles under 50 N vertical load and artificial saliva lubrication using chewing simulation. Scanning electron microscope was used to observe the microstructure of the surface and section of the coating group, and the thickness of the coating and glazing were measured. The linear roughness of the coating and polishing groups was mea-sured using a laser confocal scanning microscope. Vickers hardness was measured using a microhardness tester and the esthetic of zirconia ceramic full crown sprayed with silicon-lithium coating was preliminarily evaluated. White light interferometer was used to measure the width, the maximum depth and the volume of the wear scars of each group, and the wear depth of steatite ceramics and wear rate of zirconia ceramic specimens were calculated. Kruskal-Wallis nonparametric test and Dunn's multiple comparisons test were used to analyze the wear depth of each group (α=0.05).
RESULTS:
The microstructures of the silica-lithium spray coatings on the untreated and preliminarily polished zirconia ceramic surfaces showed the protruding defects, and the line roughness of coating group was larger than that of the polishing group. The median thickness of the silica-lithium spray coating on the preliminarily polished zirconia ceramic was 13.0 μm (interquartile range, IQR: 11.6, 17.9), while that of the silica-lithium spray coating on the untreated zirconia ceramic was 4.4 μm (IQR: 4.1, 4.7). The Vickers hardness and wear rate of the coating group were between the polishing group and the glazing group. The wear depths of the wear scars of steatite ceramics were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference between glazing and polishing groups (P < 0.05). With the increase of polishing procedure, the wear depth of steatite ceramics decreased in each subgroups. The orders of maximum depth and volume of wear scars of zirconia ceramic were the glazing group, coating group, and polishing group in descending order, and there was statistically significant difference in the maximum depth of wear scars between glazing and polishing groups (P < 0.05).
CONCLUSION
The silica-lithium spray coating on the zirconia ceramic, can be used as a new method for zirconia ceramic surface treatment, because it can increase the esthetic of zirconia ceramics compared with polishing and reduce the wear of steatite ceramics compared with glazing.
Humans
;
Silicon
;
Materials Testing
;
Friction
;
Lithium
;
Cicatrix
;
Surface Properties
;
Silicon Dioxide
;
Zirconium/chemistry*
;
Ceramics
;
Dental Porcelain
9.Prediction, analysis and application of learning curve of tooth preparation for all ceramic crowns of maxillary central incisors.
Si Yu WU ; Ya Ning LI ; Xiao ZHANG ; Long Wei LV ; Yun Song LIU ; Hong Qiang YE ; Yong Sheng ZHOU
Journal of Peking University(Health Sciences) 2023;55(1):108-113
OBJECTIVE:
To predict the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training based on the modified Wright learning curve model, then to analyze and applicate the learning curve.
METHODS:
Twelve graduate students participating in standardized dental resident training were selected to prepare the resin maxillary central incisors on phantom head simulators for all ceramic crowns 4 times. The results of preparation were evaluated by 3 prosthetic experts with at least 10 years' experience focusing on the reduction, contour, taper, shoulder, finish line, margin placement, adjacent tooth injury, and preparation time for tooth preparation. The learning rate of tooth preparation was calculated by scores of tooth preparation of 4 times. The learning curve of tooth preparation was predicted based on the modified Wright learning curve model. According to the criteria of standardized training skill examinations for dental residents in Beijing, 80 was taken as the qualified standard score. The minimum training times for tooth preparation to satisfy the qualified standard score (80) was calculated, to analyze the characteristics of learning curve and evaluate the effectiveness of tooth preparation.
RESULTS:
The scores of 4 tooth preparation were 64.03±7.80, 71.40±6.13, 74.33±5.96, and 75.98±4.52, respectively. The learning rate was (106±4)%, which showed the learning curve an upward trend. There were no significant differences between the qualified standard score and the predicted scores of tooth preparation from the 5th preparation to the 13th preparation (P > 0.05). The predicted score of the 14th preparation was higher than the qualified standard score (P < 0.05).
CONCLUSION
The trend of the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training is upward, which predicts the minimum training times higher than the qualified standard score is 14 times.
Humans
;
Tooth Preparation, Prosthodontic/methods*
;
Incisor
;
Learning Curve
;
Crowns
;
Tooth Preparation
;
Ceramics
;
Dental Porcelain
;
Dental Prosthesis Design
10.Influence of cavity design on quality of margin and marginal adaptation and microleakage of all-ceramic CAD/CAM inlays.
Journal of Peking University(Health Sciences) 2023;55(6):1105-1110
OBJECTIVE:
To investigate the influence of 135° and 90° cavity design on quality of margin and marginal adaptation and microleakage of all-ceramic computer aided design/computer aided manufacturing (CAD/CAM) inlays.
METHODS:
One hundred extracted human molars were prepared by criteria of buccal occlusal (BO) inlay. On the buccal, the mesial margin was prepared as 135° bevel while the distal margin was prepared as butt-joint. All-ceramic restorations were made in the Sirona CEREC AC CAD/CAM system with VitaBlocs Mark Ⅱ, Upcera UP.CAD, IPS e.max CAD, Upcera Hyramic and Lava Ultimate. The gaps between each inlay's mesial margin-abutment and distal margin-abutment were recorded under an optical microscope. Each inlay was adhered to the abutment and aged by thermal cycling for 10 000 times. Each specimen was cut into 3 slices after staining. Dye penetration was evaluated under an optical microscope for mesial and distal margins.
RESULTS:
Mean marginal integrity rate, mean marginal gap value and mean depth of microleakage of 135° margin of Group Upcera Hyramic and Lava Ultimate were significantly better than those of Group VitaBlocs Mark Ⅱ, Upcera UP.CAD and IPS e.max CAD(P < 0.05). Mean marginal gap value, mean depth of microleakage and scale of mean depth of microleakage of 90° margin of Group Upcera Hyramic and Lava Ultimate were significantly better than those of Group Upcera UP.CAD and IPS e.max CAD (P < 0.05) while mean marginal integrity rate was not significantly different (P>0.05). Mean marginal integrity rate of 90° margin was significantly better than that of 135° margin in each group (P < 0.05) while mean depth of microleakage between different margins was not significantly different in each group (P>0.05). Mean marginal gap value of 90° margin of Group VitaBlocs Mark Ⅱ and IPS e.max CAD was significantly better than that of 135° margin (P < 0.05) while there was not significant difference in other 3 groups between 90° and 135° margin (P>0.05). Scale of mean depth of microleakage of 135° margin of Group Upcera Hyramic and Lava Ultimate was significant better than that of 90° margin (P < 0.05) while there was not significantly different in other 3 groups between 90° and 135° margin (P>0.05).
CONCLUSION
The mesial and distal margins of abutement of all-ceramic inlay should be prepared as butt-joint.
Humans
;
Aged
;
Molar
;
Ceramics
;
Computer-Aided Design
;
Dental Porcelain
;
Materials Testing

Result Analysis
Print
Save
E-mail