1.Feasibility study of arterial pressure measurement by snuff pot artery puncture.
Chinese Critical Care Medicine 2023;35(10):1070-1073
OBJECTIVE:
To explore the feasibility of snuff pot arterial pressure measurement for patients undergoing routine elective surgery during anesthesia.
METHODS:
A prospective randomized controlled trial was conducted. Patients undergoing elective surgery admitted to the Handan Hospital of Traditional Chinese Medicine from June 1, 2020 to June 1, 2022 were enrolled. Patients who needed arterial pressure measurement for hemodynamic monitoring were randomly divided into routine radial artery puncture group and snuff pot artery puncture group with their informed consent. The patients in the routine radial artery puncture group were placed a catheter at the styloid process of the patient's radius to measure pressure. In the snuff pot artery puncture group, the snuff pot artery, that was, the radial fossa on the back of the hand (snuff box), was selected to conduct the snuff pot artery puncture and tube placement for pressure measurement. The indwelling time of arterial puncture catheter, arterial blood pressure, and complications of puncture catheterization of patients in the two groups were observed. Multivariate Logistic regression analysis was used to screen the relevant factors that affect the outcome of arterial catheterization.
RESULTS:
Finally, a total of 252 patients were enrolled, of which 130 patients received routine radial artery puncture and 122 patients received snuff pot artery puncture. There was no statistically significant difference in general information such as gender, age, body mass index (BMI), and surgical type of patients between the two groups. There was no significant difference in the indwelling time of artery puncture catheter between the routine radial artery puncture group and the snuff pot artery puncture group (minutes: 3.4±0.3 vs. 3.6±0.3, P > 0.05). The systolic blood pressure (SBP) and the diastolic blood pressure (DBP) measured in the snuff pot artery puncture group were significantly higher than those in the conventional radial artery puncture group [SBP (mmHg, 1 mmHg ≈ 0.133 kPa): 162.3±14.3 vs. 156.6±12.5, DBP (mmHg): 85.3±12.6 vs. 82.9±11.3, both P < 0.05]. There was no statistically significant difference in the incidence of complications such as arterial spasm, arterial occlusion, and pseudoaneurysm formation between the two groups. However, the incidence of hematoma formation in the snuff pot artery puncture group was significantly lower than that in the conventional radial artery puncture group (2.5% vs. 4.6%, P < 0.05). Based on the difficulty of arterial puncture, multivariate Logistic regression analysis showed that gender [odds ratio (OR) = 0.643, 95% confidence interval (95%CI) was 0.525-0.967], age (OR = 2.481, 95%CI was 1.442-4.268) and BMI (OR = 0.786, 95%CI was 0.570-0.825) were related factors that affect the outcome of arterial catheterization during anesthesia in patients undergoing elective surgery (all P < 0.05).
CONCLUSIONS
Catheterization through the snuff pot artery can be a new and feasible alternative to conventional arterial pressure measurement.
Humans
;
Arterial Pressure/physiology*
;
Feasibility Studies
;
Radial Artery/physiology*
;
Prospective Studies
;
Tobacco, Smokeless
;
Catheterization, Peripheral
;
Punctures
2.Design and application of a B-ultrasound-guided deep vein puncture precise positioning device.
Qiaoqiao PENG ; Xiangying YANG ; Yuan LI ; Weiying DAI ; Jianrong WANG
Chinese Critical Care Medicine 2023;35(10):1099-1100
Deep venipuncture catheterization is a routine and basic operation in the treatment of critically ill patients, and it is the most effective way to quickly correct the shock. Clinical B-ultrasound guided deep vein catheters can improve the success rate of puncture, but in the process of operation, the short axis needs to be replaced by the long axis. In the replacement process, the stability of the novice is insufficient, the positioning is difficult, and the operation time is too long. If only short axis puncture is used, it is impossible to know whether the current position of the puncture needle, and the puncture may be too deep and stray into the artery. The accuracy of the 45 degree angle of the injection point requires a very experienced operator. In view of the above shortcomings, doctors in the department of critical care medicine of Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine designed a B-ultrasound puncture equipment, which has obtained the National Invention Patent of China (ZL 2016 1 0571557.X). The device is composed of B-ultrasound probe fixing frame, sliding scale plate, simulation slide rule, puncture needle, sliding device. By sliding device the angle of the pinhole channel, it is conducive to the accurate positioning of the puncture target, optimizing the operation procedure, improving the puncture speed and accuracy, effectively reducing the occurrence of puncture complications, ensuring patient safety, reducing unnecessary waste of human and material resources. It can reduce the workload of medical staff and is worthy of clinical practice.
Humans
;
Catheterization, Central Venous/methods*
;
Ultrasonography, Interventional/methods*
;
Ultrasonography
;
Punctures/methods*
;
Needles
5.Dwelling time and complications of umbilical venous catheterization with different tip positions in preterm infants: a multicenter prospective cohort study.
Zi Xin YANG ; Hong Yan WANG ; Xu ZHENG ; Lu CHEN ; Juan DU ; Bin YI ; Ming Yan HEI
Chinese Journal of Pediatrics 2023;61(1):43-48
Objective: To compare the dwelling time and complications of low lying umbilical venous catheterization (UVC) in preterm infants with that of central UVC. Methods: This was a prospective cohort study. A total of 3 020 preterm infants from 44 neonatal intensive care units (NICU) who had UVC inserted from October 2019 to August 2021 were enrolled. Demographic and general baseline data, dwelling time of UVC and reasons for removal, complications and their occurrence time were collected. According to the position of the catheter tip, the preterm infants were divided into low lying UVC group (insertion depth of 3-5 cm) and central UVC group (the catheter tip was close to the entrance of right atrium, or at the 8th-9th thoracic vertebra level). The Mann-Whitney U test was used to compare the dwelling time and incidence of complications (cases/1 000 catheter days), and the independent t test and Chi-square test were used to compare the characteristics between the 2 groups. The receiver operating characteristic (ROC) curve was used to analyze the optimal cut-off value of UVC dwelling time. Results: Among the included 3 020 preterm infants, 1 624 (53.8%) were males, the gestational age was 29.9 (28.4, 31.6) weeks, the birth weight was (1 264±301) g, and 2 172 (71.9%) premature babies had central UVC. There were no significant differences in the proportion of males, the gestational age and the birth weight of neonates between the 2 groups (all P>0.05). There were also no significant differences in the rate of maternal history, PPROM>18 hours, chorioamnionitis, antenatal antibacterial angents exposure and antibacterial angents usage through UVC (all P>0.05). The dwelling time of central UVC was longer than that of low lying UVC (7 (6, 10) vs. 4 (3, 7) days, U=23.42, P<0.001). The complication incidence of central and low lying UVC were 20.0 and 70.8 cases/1 000 catheter days, respectively. The top 3 complications of central UVC were occlusion, catheter tip migration, and CLABSI (9.3, 3.5, 3.0 cases/1 000 catheter days). The top 3 complications of low lying UVC were catheter occlusion, CLABSI, and catheter tip migration (45.8, 6.3, 5.4 cases/1 000 catheter days). The ROC curve of UVC dwelling time and complications showed that the cut-off values of central UVC and low lying UVC were 6.5 and 4.5 days, respectively. The 2 groups both showed a trend of increases in the 3 complications with the prolonged dwelling time. Cox regression analysis showed that the overall difference in the proportion of occlusion between the central UVC and low lying UVC groups was statistically significant (χ2=30.18, P=0.024). There were both no significant differences in catheter tip migration and CLABSI (both P>0.05). Conclusions: The most common UVC complication in preterm infants is occlusion. It is not recommended to keep a low lying UVC for longer than 4.5 days. During the whole dwelling period, a close monitoring for UVC complications is required.
Pregnancy
;
Male
;
Infant, Newborn
;
Humans
;
Female
;
Infant
;
Infant, Premature
;
Birth Weight
;
Prospective Studies
;
Catheterization, Central Venous/adverse effects*
;
Anti-Bacterial Agents
;
Catheterization, Peripheral/adverse effects*
;
Retrospective Studies
6.Clinical experience of REcanalisation and balloon-oriented puncture for Re-insertion of long- term dialysis catheter in nonpatent central veins.
Qiang LI ; Liang You ZHANG ; Gang Yi CHEN ; Shui Fu TANG
Chinese Journal of Hepatology 2023;39(1):39-41
It is difficult to insert long-term dialysis catheters after severe stenosis or occlusion of the internal jugular vein and innominate vein. We used REcanalisation and balloon-oriented puncture for Re-insertion of dialysis catheter in nonpatent central veins (REBORN) in seven patients with severe central venous lesions, and all patients were inserted with long-term dialysis catheters successfully. None had severe complications such as pneumothorax, hemothorax, or pulmonary embolism during operation. All catheters functioned well after postoperative follow-up of 2 months. REBORN provides a novel approach to establish difficult dialysis pathways.
Humans
;
Catheterization, Central Venous/adverse effects*
;
Catheters, Indwelling
;
Renal Dialysis
;
Jugular Veins
;
Punctures
7.Peripherally inserted central venous catheter-related thrombosis in a neonate.
Shu-Juan LI ; Ke ZHANG ; Huan-Huan WANG ; Li-Ling LI ; Yun CAO ; Wen-Hao ZHOU ; Rong ZHANG
Chinese Journal of Contemporary Pediatrics 2023;25(6):658-662
The female infant in this case study was admitted to the hospital 4 hours after birth due to preterm birth and respiratory distress. On the third day after birth, peripherally inserted central venous catheter (PICC) catheterization was performed. On day 42, thrombus was found at the entrance of the right atrium from the inferior vena cava during a cardiac ultrasound, and it was considered to be related to PICC placement. Low-molecular-weight heparin and urokinase were given. After two weeks of treatment, ultrasonic monitoring showed thrombus shrinkage. No bleeding or pulmonary embolism occurred during the treatment. The patient discharged after improvement. This article mainly introduces a multidisciplinary team approach to diagnosis and treatment of PICC-related thrombosis in neonates.
Infant, Newborn
;
Infant
;
Humans
;
Female
;
Central Venous Catheters/adverse effects*
;
Premature Birth
;
Dyspnea
;
Echocardiography
;
Catheterization, Peripheral
8.Safety and efficacy of transcatheter closure of Fontan fenestration with atrial septal occluder.
Ying GUO ; Ting Liang LIU ; Xin Yi XU ; Wei GAO
Chinese Journal of Cardiology 2023;51(5):476-480
Objective: To assess the safety and efficacy of transcatheter fenestration closure following Fontan procedure with an atrial septal occluder. Methods: This is a retrospective study. The study sample consists of all consecutive patients who underwent closure of a fenestrated Fontan baffle at Shanghai Children's Medical Center Affiliated to Shanghai Jiaotong University School of Medicine between June 2002 and December 2019. The indications of Fontan fenestration closure included that normal ventricular function, targeted drugs for pulmonary hypertension and positive inotropic drugs were not required prior the procedure; and the Fontan circuit pressure was less than 16 mmHg (1 mmHg=0.133 kPa) and no more than a 2 mmHg increase during test occlusion of the fenestration. Electrocardiogram and echocardiography were reviewed at 24 hours, 1, 3, 6 months and annually thereafter post procedure. Follow-up information including clinical events and complications related to Fontan procedure was recorded. Results: A total of 11 patients, including 6 males and 5 females, aged (8.9±3.7) years old were included. The types of Fontan were extracardiac conduits (7 cases) and intra-atrial duct (4 cases). The interval between percutaneous fenestration closure and the Fontan procedure was (5.1±2.9) years. One patient reported recurrent headache after Fontan procedure. Successful fenestration occlusion with atrial septal occluder was achieved in all patients. Compared with prior closure, Fontan circuit pressure ((12.72±1.90) mmHg vs. (12.36±1.63) mmHg, P<0.05), and aortic oxygen saturation ((95.11±3.11)% vs. (86.35±7.26)%, P<0.01) were increased. There were no procedural complications. At a median follow-up of (3.8±1.2) years, there was no residual leak and evidence of stenosis within the Fontan circuit in all patient. No complication was observed during follow-up. One patient with preoperative headache did not have recurrent headache after closure. Conclusions: If the Fontan pressure is acceptable by test occlusion during the catheterization procedure, Fontan fenestration could be occluded with the atrial septum defect device. It is a safe and effective procedure, and could be used for occlusion of Fontan fenestration with varying sizes and morphologies.
Child
;
Male
;
Female
;
Humans
;
Child, Preschool
;
Septal Occluder Device
;
Retrospective Studies
;
Atrial Fibrillation
;
Cardiac Catheterization/methods*
;
China
;
Fontan Procedure/methods*
;
Treatment Outcome
9.Long-term outcome of transcatheter repair of paravalvular leak post surgical mitral valve replacement.
Chao Fan XING ; Xin PAN ; Cheng WANG ; Lan MA ; Xiao Lei WANG ; Yan Jie LI ; Ben HE
Chinese Journal of Cardiology 2023;51(7):742-749
Objective: To explore the long-term clinical efficacy of transcatheter repair of mitral paravalvular leak (PVL) post surgical mitral valve replacement. Methods: This study is a retrospective study. Patients who completed transcatheter repair of paravalvular leak after surgical mitral valve replacement at Shanghai Chest Hospital, Shanghai Jiaotong University School of Medicine from March 2010 to December 2018 were included. Technical success was defined as the occluder being stably implanted in the paravalvular leak site without affecting the function of the mitral valve and surrounding tissues; and there were no intervention-related complications, such as new hemolysis or aggravated hemolysis, and echocardiography confirmed mitral paravalvular regurgitation reduced by more than 1 grade. Patients were followed up at 30 days, 1, and 3 years after the intervention. The main endpoints were all-cause death and re-surgery due to interventional failure or serious complications. The occurrence of occluder-mediated hemolysis and chronic renal insufficiency was recorded, and patients were monitored with echocardiography during follow up. Results: A total of 75 patients were included, aged (54.3±22.9) years old, and 38 patients were males. All patients had decreased cardiac function and/or hemolysis before intervention. Procedural success was achieved in 54 patients (72.0%). Incidence of device-mediated hemolysis was 18.7% (14/75). During the follow-up period, all-cause death occurred in 7 patients (9.3%), and 3 were cardiac deaths.The 3-year event-free survival rate was 81.3% (61/75). The need for cardiac surgery was 9.3% (7/75): 3 cases due to severe device-mediated hemolysis, 2 cases due to prosthetic valve failure and 2 cases due to moderate to severe residual regurgitation. The echocardiography follow-up results showed that the position of the occluder was stable, there was no impact on the artificial valve function and surrounding structures, and the residual regurgitation was stable without progressive increase in event-free patients. Compared with pre-intervention, the left ventricular end systolic diameter ((33.9±7.4)mm vs. (38.3±8.9) mm, P=0.036), end diastolic diameter ((53.7±8.3) mm vs. (58.4±9.1) mm, P=0.045) and left atrial diameter (59.3 (44.5, 90.7) mm vs. 64.3 (44.8, 96.6) mm, P=0.049) were significantly reduced, pulmonary artery systolic pressure was also significantly decreased ((36.5±15.8) mmHg vs. (46.3±14.9) mmHg, P=0.022, 1 mmHg=0.133 kPa). There was no significant difference between 3 years and 1 year after transcatheter repair of mitral paravalvular leak post surgical mitral valve replacement (all P>0.05). Conclusion: Transcatheter repair of mitral paravalvular leak post surgical mitral valve replacement is an effective treatment option in selective patients.
Male
;
Humans
;
Adult
;
Middle Aged
;
Aged
;
Female
;
Mitral Valve/surgery*
;
Heart Valve Prosthesis Implantation
;
Heart Valve Prosthesis
;
Retrospective Studies
;
Hemolysis
;
China
;
Mitral Valve Insufficiency/surgery*
;
Treatment Outcome
;
Cardiac Catheterization
;
Prosthesis Failure
10.Preliminary experience of transcatheter pulmonary valve replacement using domestic balloon-expandable valve.
Zhen Gang ZHAO ; Rui Tao LI ; Xin WEI ; Yong PENG ; Jia Fu WEI ; Sen HE ; Qiao LI ; Xiao LI ; Yi Jian LI ; Xiang LI ; Xuan ZHOU ; Ming Xia ZHENG ; Guo CHEN ; Qi AN ; Mao CHEN ; Yuan FENG
Chinese Journal of Cardiology 2023;51(8):825-831
Objectives: To evaluate the feasibility and preliminary clinical results of transcatheter pulmonary valve replacement (TPVR) with the domestically-produced balloon-expandable Prizvalve system. Methods: This is a prospective single-center observational study. Patients with postoperative right ventricular outflow tract (RVOT) dysfunction, who were admitted to West China Hospital of Sichuan University from September 2021 to March 2023 and deemed anatomically suitable for TPVR with balloon-expandable valve, were included. Clinical, imaging, procedural and follow-up data were analyzed. The immediate procedural results were evaluated by clinical implant success rate, which is defined as successful valve implantation with echocardiography-assessed pulmonary regurgitation
Male
;
Humans
;
Pulmonary Valve/surgery*
;
Heart Valve Prosthesis/adverse effects*
;
Heart Valve Prosthesis Implantation
;
Constriction, Pathologic/surgery*
;
Prospective Studies
;
Ventricular Outflow Obstruction/surgery*
;
Treatment Outcome
;
Cardiac Catheterization/methods*
;
Transcatheter Aortic Valve Replacement

Result Analysis
Print
Save