1.Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients.
Ting YANG ; Li WENG ; Wei JIANG ; Shan LI ; Bin DU
Chinese Medical Journal 2022;135(6):672-680
BACKGROUND:
It is still unclear what the minimal infusion volume is to effectively predict fluid responsiveness. This study was designed to explore the minimal infusion volume to effectively predict fluid responsiveness in septic shock patients. Hemodynamic effects of fluid administration on arterial load were observed and added values of effective arterial elastance (Ea) in fluid resuscitation were assessed.
METHODS:
Intensive care unit septic shock patients with indwelling pulmonary artery catheter (PAC) received five sequential intravenous boluses of 100 mL 4% gelatin. Cardiac output (CO) was measured with PAC before and after each bolus. Fluid responsiveness was defined as an increase in CO >10% after 500 mL fluid infusion.
RESULTS:
Forty-seven patients were included and 35 (74.5%) patients were fluid responders. CO increasing >5.2% after a 200 mL fluid challenge (FC) provided an improved detection of fluid responsiveness, with a specificity of 80.0% and a sensitivity of 91.7%. The area under the ROC curve (AUC) was 0.93 (95% CI: 0.84-1.00, P < 0.001). Fluid administration induced a decrease in Ea from 2.23 (1.46-2.78) mmHg/mL to 1.83 (1.34-2.44) mmHg/mL (P = 0.002), especially for fluid responders in whom arterial pressure did not increase. Notably, the baseline Ea was able to detect the fluid responsiveness with an AUC of 0.74 (95% CI: 0.59-0.86, P < 0.001), whereas Ea failed to predict the pressure response to FC with an AUC of 0.50 (95% CI: 0.33-0.67, P = 0.086).
CONCLUSION:
In septic shock patients, a minimal volume of 200 mL 4% gelatin could reliably detect fluid responders. Fluid administration reduced Ea even when CO increased. The loss of arterial load might be the reason for patients who increased their CO without pressure responsiveness. Moreover, a high level of Ea before FC was able to predict fluid responsiveness rather than to detect the pressure responsiveness.
TRIAL REGISTRATION
ClinicalTrials.gov, NCT04515511.
Cardiac Output/physiology*
;
Fluid Therapy
;
Gelatin/therapeutic use*
;
Hemodynamics
;
Humans
;
Shock, Septic/therapy*
2.Maternal hepatic venous hemodynamics and cardiac output in normal and fetal growth restricted pregnancies.
Haiqin LIAO ; Dan ZHOU ; Kui TANG ; Minzhi OUYANG ; Xiaofang WANG ; Ming ZHANG
Journal of Central South University(Medical Sciences) 2018;43(9):987-993
To evaluate relationship of maternal hepatic vein Doppler flow parameters and cardiac output (CO) with neonatal birth weight in uncomplicated pregnancies (UP) and pregnancies complicated by fetal growth restriction (FGR) .
Methods: Hepatic vein impedance index (HVI), venous pulse transit time (VPTT), and CO were measured in women with UP at the 14th-37th weeks and complicated by FGR at the 26th-37th weeks who underwent maternal hepatic hemodynamic and echocardiographic examination during the ultrasonography. After delivery, the birth weight and the birth weight percentile of each neonate in this study were recorded. Correlations among HVI, VPTT, and CO were analyzed.
Results: In the UP group, HVI, VPTT, and CO changed with the increase of gestation. In the FGR group, HVI was higher, VPTT was shorter, CO and neonatal birth weight were obviously lower than those in the UP at the 26th-37th weeks (P<0.05).
Conclusion: There is a series of adaptive changes in hepatic venous hemodynamics and CO in UP with the increase of gestation to meet the demand of fetal growth, while the maladaptive changes in hepatic venous hemodynamics and CO in pregnant woman may contribute to FGR.
Birth Weight
;
Cardiac Output
;
Female
;
Fetal Development
;
physiology
;
Fetal Growth Retardation
;
physiopathology
;
Hemodynamics
;
physiology
;
Hepatic Veins
;
physiopathology
;
Humans
;
Infant, Newborn
;
Pregnancy
;
Ultrasonography, Prenatal
3.Where Is the “Optimal” Fontan Hemodynamics?.
Korean Circulation Journal 2017;47(6):842-857
Fontan circulation is generally characterized by high central venous pressure, low cardiac output, and slightly low arterial oxygen saturation, and it is quite different from normal biventricular physiology. Therefore, when a patient with congenital heart disease is selected as a candidate for this type of circulation, the ultimate goals of therapy consist of 2 components. One is a smooth adjustment to the new circulation, and the other is long-term circulatory stabilization after adjustment. When either of these goals is not achieved, the patient is categorized as having “failed” Fontan circulation, and the prognosis is dismal. For the first goal of smooth adjustment, a lot of effort has been made to establish criteria for patient selection and intensive management immediately after the Fontan operation. For the second goal of long-term circulatory stabilization, there is limited evidence of successful strategies for long-term hemodynamic stabilization. Furthermore, there have been no data on optimal hemodynamics in Fontan circulation that could be used as a reference for patient management. Although small clinical trials and case reports are available, the results cannot be generalized to the majority of Fontan survivors. We recently reported the clinical and hemodynamic characteristics of early and late failing Fontan survivors and their association with all-cause mortality. This knowledge could provide insight into the complex Fontan pathophysiology and might help establish a management strategy for long-term hemodynamic stabilization.
Cardiac Output
;
Cardiac Output, Low
;
Central Venous Pressure
;
Fontan Procedure
;
Heart Defects, Congenital
;
Hemodynamics*
;
Humans
;
Mortality
;
Oxygen
;
Patient Selection
;
Physiology
;
Prognosis
;
Survivors
;
Vascular Resistance
4.Experience with Mechanical Circulatory Support for Medically Intractable Low Cardiac Output in a Pediatric Intensive Care Unit.
Jung Bin PARK ; Jae Gun KWAK ; Hong Gook LIM ; Woong Han KIM ; Jeong Ryul LEE ; Yong Jin KIM
Korean Circulation Journal 2017;47(4):490-500
BACKGROUND AND OBJECTIVES: Mechanical circulatory support with extracorporeal membrane oxygenation (ECMO) and ventricular assist device has always been the optimal choice for treating the majority of medically intractable low cardiac output case. We retrospectively investigated our institution's outcomes and variables associated with a high risk of mortality. SUBJECTS AND METHODS: From 1999 to 2014, 86 patients who were of pediatric age or had grown-up congenital heart disease underwent mechanical circulatory support for medically intractable low cardiac output in our pediatric intensive care unit. Of these, 9 grown-up congenital heart disease patients were over 18 years of age, and the median age of the subject group was 5.82 years (range: 1 day to 41.6 years). A review of all demographic, clinical, and surgical data and survival analysis were performed. RESULTS: A total of 45 (52.3%) patients were successfully weaned from the mechanical assist device, and 25 (29.1%) survivors were able to be discharged. There was no significant difference in results between patients over 18 years and under 18 years of age. Risk factors for mortality were younger age (<30 days), functional single ventricle anatomy, support after cardiac operations, longer support duration, and deteriorated pre-ECMO status (severe metabolic acidosis and increased levels of lactate, creatinine, bilirubin, or liver enzyme). The survival rate has improved since 2010 (from 25% before 2010 to 35% after 2010), when we introduced an upgraded oxygenator, activated heart transplantation, and also began to apply ECMO before the end-stage of cardiac dysfunction, even though we could not reveal significant correlations between survival rate and changed strategies associated with ECMO. CONCLUSION: Mechanical circulatory support has played a critical role and has had a dramatic effect on survival in patients with medically intractable heart failure, particularly in recent years. Meticulous monitoring of acid-base status, laboratory findings, and early and liberal applications are recommended to improve outcomes without critical complication rates, particularly in neonates with single ventricle physiology.
Acidosis
;
Bilirubin
;
Cardiac Output, Low*
;
Creatinine
;
Critical Care*
;
Extracorporeal Membrane Oxygenation
;
Heart Defects, Congenital
;
Heart Failure
;
Heart Transplantation
;
Heart-Assist Devices
;
Humans
;
Infant, Newborn
;
Intensive Care Units*
;
Lactic Acid
;
Liver
;
Mortality
;
Oxygen
;
Oxygenators
;
Physiology
;
Resuscitation
;
Retrospective Studies
;
Risk Factors
;
Survival Rate
;
Survivors
5.Monitoring Changes in Hepatic Venous Velocities Flow after a Fluid Challenge Can Identify Shock Patients Who Lack Fluid Responsiveness.
Wei DU ; Xiao-Ting WANG ; Yun LONG ; Da-Wei LIU
Chinese Medical Journal 2017;130(10):1202-1210
BACKGROUNDEvaluating the hemodynamic status and predicting fluid responsiveness are important in critical ultrasound assessment of shock patients. Transthoracic echocardiography with noninvasive diagnostic parameters allows the assessment of volume responsiveness. This study aimed to assess the hemodynamic changes in the liver and systemic hemodynamic changes during fluid challenge and during passive leg raising (PLR) by measuring hepatic venous flow (HVF) velocity.
METHODSThis is an open-label study in a tertiary teaching hospital. Shock patients with hypoperfusion who required fluid challenge were selected for the study. Patients <18 years old and those with contraindications to PLR were excluded from the study. Baseline values were measured, PLR tests were performed, and 500 ml of saline was infused over 30 min. Parameters associated with cardiac output (CO) in the left ventricular outflow tract were measured using the Doppler method. In addition, HVF velocity and right ventricular function parameters were determined.
RESULTSMiddle hepatic venous (MHV) S-wave velocity was positively correlated in all patients with CO at baseline (r = 0.706, P< 0.01) and after volume expansion (r = 0.524, P= 0.003). CO was also significantly correlated with MHV S-wave velocity in responders (r = 0.608, P< 0.01). During PLR, however, hepatic venous S-wave velocity did not correlate with CO. For the parameter ΔMHV D (increase in change in MHV D-wave velocity after volume expansion), defined as (MHV DafterVE - MHV DBaseline)/MHV DBaseline× 100%, >21% indicated no fluid responsiveness, with a sensitivity of 100%, a specificity of 71.2%, and an area under the receiver operating characteristic curve of 0.918.
CONCLUSIONSDuring fluid expansion, hepatic venous S-wave velocity can be used to monitor CO, whether or not it is increasing. ΔMHV D ≥21% indicated a lack of fluid responsiveness, thus helping to decide when to stop infusions.
Aged ; Blood Pressure ; physiology ; Cardiac Output ; physiology ; Echocardiography ; Female ; Fluid Therapy ; Hemodynamics ; physiology ; Hepatic Veins ; physiology ; Humans ; Male ; Middle Aged ; Monitoring, Physiologic ; methods ; Portal Vein ; physiology ; ROC Curve ; Shock ; physiopathology ; Stroke Volume ; physiology
6.Application of ultrasonic cardiac output monitor in evaluation of cardiac function in children with severe pneumonia.
Juan FAN ; Zhi-Ying CHEN ; Peng-Yuan CHEN ; Chang-Hui CHEN
Chinese Journal of Contemporary Pediatrics 2016;18(9):817-820
OBJECTIVETo study the clinical application of ultrasonic cardiac output monitor (USCOM) in evaluation of cardiac function in children with severe pneumonia.
METHODSTwenty-nine children with severe pneumonia were enrolled in the observation group and forty-three children with common pneumonia were enrolled in the control group. The USCOM was used to measure the cardiac function indices in the two groups. The results were compared between the two groups. The changes in cardiac function indices after treatment were evaluated in the observation group.
ESULTSThe observation group had a significantly higher heart rate and significantly lower cardiac output, systolic volume, and aortic peak velocity than the control group (P<0.05). There were no significant differences in cardiac index or systemic vascular resistance between the two groups (P>0.05). In the observation group, the heart rate, cardiac output, systolic volume, aortic peak velocity, cardiac index, and systemic vascular resistance were significantly improved after treatment (P<0.05).
CONCLUSIONSThe USCOM is a fast, convenient, and accurate approach for dynamic measurement of cardiac function and overall circulation state in children with severe pneumonia. The USCOM can provide a basis for diagnosis, treatment, and evaluation of the disease, which is quite useful in clinical practice.
Cardiac Output ; physiology ; Child ; Female ; Humans ; Infant ; Male ; Monitoring, Physiologic ; instrumentation ; Pneumonia ; physiopathology ; Ultrasonics
7.Hepatic Perfusion Alterations in Septic Shock Patients: Impact of Early Goal-directed Therapy.
Xi-Wen ZHANG ; Jian-Feng XIE ; Ai-Ran LIU ; Ying-Zi HUANG ; Feng-Mei GUO ; Cong-Shan YANG ; Yi YANG ; Hai-Bo QIU
Chinese Medical Journal 2016;129(14):1666-1673
BACKGROUNDEarly goal-directed therapy (EGDT) has become an important therapeutic management in early salvage stage of septic shock. However, splenic organs possibly remained hypoperfused and hypoxic despite fluid resuscitation. This study aimed to evaluate the effect of EGDT on hepatic perfusion in septic shock patients.
METHODSA prospective observational study was carried out in early septic shock patients who were admitted to Intensive Care Unit within 24 h after onset and who met all four elements of the EGDT criteria after treatment with the standard EGDT procedure within 6 h between December 1, 2012 and November 30, 2013. The hemodynamic data were recorded, and oxygen metabolism and hepatic functions were monitored. An indocyanine green clearance test was applied to detect the hepatic perfusion. The patients' characteristics were compared before treatment (T0), immediately after EGDT (T1), and 24 h after EGDT (T2). This study is registered at ClinicalTrials.org, NCT02060773.
RESULTSTwenty-one patients were included in the study; however, the hepatic perfusion data were not included in the analysis for two patients; therefore, 19 patients were eligible for the study. Hemodynamics data, as monitored by pulse-indicator continuous cardiac output, were obtained from 16 patients. There were no significant differences in indocyanine green plasma disappearance rate (ICG-PDR) and 15-min retention rate (R15) at T0 (11.9 ± 5.0%/min and 20.0 ± 13.2%), T1 (11.4 ± 5.1%/min and 23.6 ± 14.9%), and T2 (11.0 ± 4.5%/min and 23.7 ± 15.3%) (all P > 0.05). Both of the alterations of ICG-PDR and R15 showed no differences at T0, T1, and T2 in the patients of different subgroups that achieved different resuscitation goal numbers when elected (P > 0.05).
CONCLUSIONThere were no hepatic perfusion improvements after EGDT in the early phase of patients with septic shock.
TRIAL REGISTRATIONClinicaltrials.gov NCT02060773 (https://clinicaltrials.gov/ct2/show/NCT02060773).
Aged ; Aged, 80 and over ; Cardiac Output ; physiology ; Disease Management ; Female ; Fluid Therapy ; Hemodynamics ; physiology ; Humans ; Intensive Care Units ; statistics & numerical data ; Male ; Middle Aged ; Prospective Studies ; Shock, Septic ; therapy
8.Comparison of cardiac output and hemodynamic responses of intubation among different videolaryngoscopies in normotensive and hypertensive patients.
Amro Faez ABDELGAWAD ; Qin-Fang SHI ; Mohamed Abo HALAWA ; Zhi-Lin WU ; Zhou-Yang WU ; Xiang-Dong CHEN ; Shang-Long YAO
Journal of Huazhong University of Science and Technology (Medical Sciences) 2015;35(3):432-438
Tracheal intubation with Macintosh laryngoscope (MAC) might result in severe cardiovascular complications. The results of conducted studies investigating the effects of videolaryngoscopies on hemodynamic response of tracheal intubation are conflicting. We know little about the effects of videolaryngoscopies on cardiac output changes during tracheal intubation. We compared cardiac output (COP) and hemodynamic responses in normal blood pressure (n=60) and hypertensive patients (n=60) among 3 intubation devices: the MAC, the UE videolaryngoscopy ® (UE), and the UE video intubation stylet ® (VS). Cardiac index (CI), stroke volume index (SVI), heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP) were recorded using LidcoRapid (V2)® preinduction, preintubation, and every minute for the first 5 min after intubation. We assessed oropharyngeal and laryngeal structures injury as well. Intubation time was significantly shorter than MAC groups (P<0.001) only in UE group of normotensive and hypertensive patients. In normotensive patients, there were no significant differences in any of COP variables or hemodynamic variables among the three devices. In hypertensive patients, SBP and DBP in the MAC group were significantly higher (P<0.05 or <0.01) than the UE and VS groups at 1, 2 and 3 min after intubation, but there were no significant differences in CI, SVI and HR among the three devices. There was no significant difference in oropharyngeal and laryngeal structures injury among all groups. It was concluded that both the UE and VS attenuate only the hemodynamic response to intubation as compared with the MAC in hypertensive patients, but not in normotensive patients.
Adult
;
Aged
;
Blood Pressure
;
physiology
;
Cardiac Output
;
physiology
;
Female
;
Hemodynamics
;
Humans
;
Hypertension
;
physiopathology
;
surgery
;
Intubation, Intratracheal
;
instrumentation
;
methods
;
Laryngoscopy
;
instrumentation
;
methods
;
Larynx
;
anatomy & histology
;
injuries
;
Male
;
Middle Aged
;
Oropharynx
;
anatomy & histology
;
injuries
;
Video-Assisted Surgery
;
methods
;
Young Adult
9.Efficacy of Goal-Directed Therapy Using Bioreactance Cardiac Output Monitoring after Valvular Heart Surgery.
Sak LEE ; Seung Hyun LEE ; Byung Chul CHANG ; Jae Kwang SHIM
Yonsei Medical Journal 2015;56(4):913-920
PURPOSE: We compared the efficacy of postoperative hemodynamic goal-directed therapy (GDT) using a pulmonary artery catheter (PAC) and bioreactance-based noninvasive cardiac output monitoring (NICOM) in patients with atrial fibrillation undergoing valvular heart surgery. MATERIALS AND METHODS: Fifty eight patients were randomized into two groups of GDT with common goals to maintain a mean arterial pressure of 60-80 mm Hg and cardiac index > or =2 L/min/m2: the PAC group (n=29), based on pulmonary capillary wedge pressure, and the NICOM group (n=29), based on changes in stroke volume index after passive leg raising. The primary efficacy variable was length of hospital stay. Secondary efficacy variables included resource utilization including vasopressor and inotropic requirement, fluid balance, and major morbidity endpoints. RESULTS: Patient characteristics and operative data were similar between the groups, except that significantly more patients underwent double valve replacement in the NICOM group. The lengths of hospital stay were not different between the two groups (12.2+/-4.8 days vs. 10.8+/-4.0 days, p=0.239). Numbers of patients requiring epinephrine (5 vs. 0, p=0.019) and ventilator care >24 h (6 vs. 1, p=0.044) were significantly higher in the PAC group. The PAC group also required significantly larger amounts of colloid (1652+/-519 mL vs. 11430+/-463 mL, p=0.004). CONCLUSION: NICOM-based postoperative hemodynamic GDT showed promising results in patients with atrial fibrillation undergoing valvular heart surgery in terms of resource utilization.
Aged
;
Aged, 80 and over
;
Cardiac Output/*physiology
;
Cardiac Surgical Procedures/*methods
;
Catheterization, Swan-Ganz
;
Female
;
Goals
;
Heart Valves/*surgery
;
Hemodynamics
;
Humans
;
Length of Stay/*statistics & numerical data
;
Male
;
Middle Aged
;
Monitoring, Intraoperative/methods
;
Monitoring, Physiologic/methods
;
Postoperative Complications/epidemiology/prevention & control
;
Postoperative Period
10.Normal reference values and predict equations of heart function.
Zhi-nan LU ; Sun XING-GUO ; Song-shou MAO ; M J BUDOFF ; W W STRINGER ; Wan-gang GE ; Hao LI ; Jie HUANG ; Fang LIU ; Sheng-shou HU
Chinese Journal of Applied Physiology 2015;31(4):332-336
OBJECTIVEFor heart functional parameters, we commonly used normal range. The reference values and predict formulas of heart functional parameters and their relationships with individual characteristics are still lack.
METHODSLeft ventricular (LV) volumes (end-diastolic volume and end-systolic volume), stroke volume (SV), ejection fraction (EF) and cardiac output (CO) were measured by cardiac CT angiography (CAT) in 1 200 healthy Caucasian volunteers, men 807 and women 393, and age 20-90yr. The results are analyzed by high-accuracy three-dimensional imaging technology, and then measured the dynamic changes of the volumes of each atriam and ventricule during their contractions and relaxations. The gender, age, height and weight were analyzed by multiple linear regression to predict LV functional parameters.
RESULTSExcept the LVEF was lower in man than in women (P < 0.001), all other LV functional parameters of EDV, ESV, SV, FE and CO were higher in man (P < 0.001). Multiple linear regression indicated that age, gender, height and weight are all independent factors of EDV, ESV and SV (P < 0.001). CO could be significantly predicted by age, gender and weight (P < 0.001), but not height (P > 0.05). The predict equation for CO (L x min(-1)) = 6.963+0.446 (Male) -0.037 x age (yr) +0.013 x weight (kg).
CONCLUSIONAge, gender, height and weight are predictors of heart functions. The reference values and predict equations are important for noninvasive and accurate evaluation of cardiovascular disease and individualized treatment.
Adult ; Age Factors ; Aged ; Aged, 80 and over ; Body Height ; Body Weight ; Cardiac Output ; Female ; Heart ; physiology ; Humans ; Male ; Middle Aged ; Reference Values ; Sex Factors ; Stroke Volume ; Ventricular Function, Left ; Young Adult

Result Analysis
Print
Save
E-mail