1.Biocompatibility of poly(vinylidene fluoride)piezoelectric bionic periosteum prepared by electrospinning
Shuai ZHAO ; Dongyao LI ; Suiyan WEI ; Yijing CAO ; Yan XU ; Guoqiang XU
Chinese Journal of Tissue Engineering Research 2025;29(4):730-737
		                        		
		                        			
		                        			BACKGROUND:Our previous studies have found that poly(vinylidene fluoride)bionic periosteum prepared by electrospinning has good cytocompatibility,but its biocompatibility is unknown. OBJECTIVE:To evaluate the biocompatibility of poly(vinylidene fluoride)bionic periosteum doped with Zn2+and Mg2+. METHODS:Poly(vinylidene fluoride),poly(vinylidene fluoride)bionic periosteum doped with 1%Zn2+,doped with 1%Mg2+,and doped with 1%(Zn2++Mg2+)were prepared by electrospinning to make bionic periosteum extract.SD rats were selected as the experimental subjects for hemolysis test,short-term systemic toxicity test,and heat source test.Guinea pigs were selected as the experimental subjects for skin sensitization test.The biocompatibility of bionic periosteum of four groups was tested. RESULTS AND CONCLUSION:(1)The hemolysis test results showed that the hemolysis rates of 1%Zn2+poly(vinylidene fluoride),1%Mg2+poly(vinylidene fluoride),1%Zn2++1%Mg2+poly(vinylidene fluoride)bionic periosteum and poly(vinylidene fluoride)extract were(0.130±0.013)%,(0.149±0.020)%,(0.466±0.018)%,and(0.037±0.018)%,respectively,which met the hemocompatibility standard of biomaterials.(2)The results of short-term systemic toxicity test showed that the four groups of bionic periosteal extract had no toxic signs such as body mass reduction,food intake changes,and dyspnea in SD rats,and had no toxic effects on major organs of rats.(3)Heat source test results showed that after intervention with poly(vinylidene fluoride)bionic periosteum doped with 1%Zn2+,doped with 1%Mg2+,and doped with 1%(Zn2++Mg2+),and poly(vinylidene fluoride)bionic periosteum extract,the elevated body temperature values of SD rats were(0.133±0.058),(0.100±0.010),(0.300±0.010),and(0.300±0.017)℃respectively.All were less than 0.6 ℃and the total temperature increase was less than 1.4 ℃.(4)The results of skin sensitization test showed that no erythema or edema was observed under the skin of guinea pigs after the intervention of bionic periosteum extract of four groups.(5)The results showed that poly(vinylidene fluoride)and poly(vinylidene fluoride)bionic periosteum doped with Zn2+and Mg2+had good biocompatibility.
		                        		
		                        		
		                        		
		                        	
2.Analysis on Quality Standard of Sennae Folium(Cassia angustifolia) Dispensing Granules Based on Standard Decoctions
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):192-200
		                        		
		                        			
		                        			ObjectiveTo establish the quality standards for Sennae Folium(Cassia angustifolia) dispensing granules based on standard decoctions. MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established for 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 of Sennae Folium(C. angustifolia) dispensing granules from different manufacturers, and the similarity evaluation, hierarchical cluster analysis(HCA) and principal component analysis(PCA) were performed. Linear calibration with two reference substances(LCTRS) and quantitative analysis of multi-components by single-marker(QAMS) were established for the common peaks in the specific chromatograms to determine the contents of main components in the decoction pieces, standard decoctions and dispensing granules, and to calculate their transfer rates from decoction pieces to standard decoctions and dispensing granules. ResultsThe similarities of specific chromatograms of 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 batches of Sennae Folium(C. angustifolia) dispensing granules were all greater than 0.95, and a total of 8 characteristic peaks were calibrated, and five of them were identified, including kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A. HCA and PCA results showed that there were certain differences in the composition of different batches of standard decoctions, but no clustering was observed in the production area. As the standard decoctions, the extract rate of 15 batches of samples was 26.54%-45.38%, the contents of kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A were 12.16-19.26, 2.57-4.94, 3.27-5.11, 6.75-11.39, 4.69-7.79 mg·g-1, and their transfer rates from decoction pieces to standard decoctions were 45.41%-79.02%, 29.12%-55.07%, 40.52%-67.90%, 24.72%-49.12%, 27.54%-49.34%, respectively. The extract rates of Sennae Folium(C. angustifolia) dispensing granules(C8-C10) were 38.10%-39.50%, the transfer rates of the above five components from decoction pieces to dispensing granules were 72.85%-73.58%, 53.43%-53.94%, 40.19%-40.74%, 24.62%-25.00%, 28.65%-29.11%, respectively, which were generally consistent with the transfer rates from decoction pieces to standard decoctions. ConclusionCompared with the relative retention time method, LCTRS has higher prediction accuracy and is more suitable for chromatographic columns. The established quality control standard of Sennae Folium(C. angustifolia) dispensing granules based on standard decoction is reasonable and reliable, and all indicators of samples from different manufacturers are within the range specified based on the standard decoction, which can provide reference for the quality control and process research of this dispensing granules. 
		                        		
		                        		
		                        		
		                        	
3.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
		                        		
		                        			
		                        			ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules. 
		                        		
		                        		
		                        		
		                        	
4.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
		                        		
		                        			
		                        			ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules. 
		                        		
		                        		
		                        		
		                        	
5.Mitofusin 2: an emerging drug target
Yubing SHUAI ; Qiudan WANG ; Tianyu HE ; LIjuan CAO
Journal of China Pharmaceutical University 2025;56(1):1-9
		                        		
		                        			
		                        			Mitofusin 2 (MFN2) residing on the outer mitochondrial membrane is a pivotal factor participating in mitochondrial fusion and maintaining mitochondrial morphology. Due to its multifaceted cellular functions, MFN2 is implicated in the pathogenesis of diverse maladies, notably type 2 Charcot-Marie-Tooth disease, which has catalyzed a surge in pharmaceutical endeavors directed towards MFN2. This article reviews the function of MFN2 and its role in a variety of diseases, outlines the current status of drug discovery against MFN2, and summarizes potential drug molecules currently in preclinical research, aiming to provide some reference for the research and development of drugs and therapies targeting MFN2.
		                        		
		                        		
		                        		
		                        	
6.“Textbook Outcome” and Influencing Factors in Patients with Pancreatic Ductal Adenocarcinoma Following Laparoscopic Pancreaticoduodenectomy: A Retrospective Cohort Study
Yakai YANG ; Shuai XU ; Chunhong ZHAO ; Yukun CAO ; Guangsheng YU ; Jun LIU
Cancer Research on Prevention and Treatment 2025;52(10):827-833
		                        		
		                        			
		                        			Objective To investigate the short- and long-term prognoses and the risk factors affecting “textbook outcome” (TO) after laparoscopic pancreaticoduodenectomy (LPD) for pancreatic ductal adenocarcinoma (PDAC). Methods The clinical and follow-up data of patients diagnosed with PDAC and treated with LPD from January 2019 to December 2022 were retrospectively analyzed. The prognosis was compared between TO and non-TO groups, and univariate and multivariate logistic regression analyses were used to identify independent prognostic factors for TO. Results A total of 284 patients were enrolled in this study, including 185 cases in the TO group and 99 cases in the non-TO group. The 1-, 3- and 5-year overall survival (OS) rates of the TO and non-TO groups with PDAC were 87.3% vs. 85.9%, 52.5% vs. 38.4%, and 18.0% vs. 4.5%, respectively (P=0.020); the recurrence-free survival (RFS) rates were 74.1% vs. 65.7%, 27.1% vs. 21.0%, and 10.0% vs. 0%, respectively (P=0.042). Multivariate logistic regression analysis showed that operation time >360 min (OR=0.561, 95%CI: 0.321-0.979, P=0.042), intraoperative blood loss >400 ml (OR=0.392, 95%CI: 0.175-0.879, P=0.023), hard or tough texture of pancreas (OR=2.240, 95%CI: 1.247-4.022, P=0.007), and main pancreatic duct diameter >3 mm (OR=1.931, 95%CI: 1.126-3.312, P=0.017) were independent prognostic factors for TO. Conclusion After the learning curve, more than 60% of patients with PDAC can achieve TO after LPD. The chances of achieving TO are significantly reduced when the operation time >360 min, the intraoperative blood loss >400 ml, the texture of pancreas was soft, and the diameter of the main pancreatic duct >3 mm.
		                        		
		                        		
		                        		
		                        	
7.pH-Responsive polymer boosts cytosolic siRNA release for retinal neovascularization therapy.
Shuai GUO ; Chunhui LI ; Changrong WANG ; Xiaowen CAO ; Xinyue LIU ; Xing-Jie LIANG ; Yuanyu HUANG ; Yuhua WENG
Acta Pharmaceutica Sinica B 2024;14(2):781-794
		                        		
		                        			
		                        			Small interfering RNA (siRNA) has a promising future in the treatment of ocular diseases due to its high efficiency, specificity, and low toxicity in inhibiting the expression of target genes and proteins. However, due to the unique anatomical structure of the eye and various barriers, delivering nucleic acids to the retina remains a significant challenge. In this study, we rationally design PACD, an A-B-C type non-viral vector copolymer composed of a hydrophilic PEG block (A), a siRNA binding block (B) and a pH-responsive block (C). PACDs can self-assemble into nanosized polymeric micelles that compact siRNAs into polyplexes through simple mixing. By evaluating its pH-responsive activity, gene silencing efficiency in retinal cells, intraocular distribution, and anti-angiogenesis therapy in a mouse model of hypoxia-induced angiogenesis, we demonstrate the efficiency and safety of PACD in delivering siRNA in the retina. We are surprised to discover that, the PACD/siRNA polyplexes exhibit remarkable intracellular endosomal escape efficiency, excellent gene silencing, and inhibit retinal angiogenesis. Our study provides design guidance for developing efficient nonviral ocular nucleic acid delivery systems.
		                        		
		                        		
		                        		
		                        	
8.Association of Polymorphisms in the 3'UTR of Genes in the ERK1/2 Signaling Pathway with Non-small Cell Lung Cancer
Chao HONG ; Xudong XIANG ; Yingfu LI ; Yang CAO ; Xueya CHEN ; Shuai LI ; Anhao XING ; Mu LIN ; Qianli MA
Journal of Kunming Medical University 2024;45(3):7-17
		                        		
		                        			
		                        			Objective To investigate the association between four single nucleotide polymorphisms(SNP)(rs9340 in MAPK1,rs14804 in NRAS,rs712 and rs7973450 in KRAS)in the 3'UTR of ERK1/2 signaling pathway-related genes and non-small cell lung cancer(NSCLC).Methods A total of 478 NSCLC patients and 480 healthy controls were enrolled in this study.Four SNPs were genotyped by using TaqMan assays.The association between the four SNPs and NSCLC was analyzed.Results The distribution frequency difference of the allele of rs9340 was statistically significant between the control group and the non-small cell squamous cell carcinoma(SCC)group(P = 0.009),suggesting that the G allele of rs9340 may be a protective factor for non-small cell lung squamous cell carcinoma(OR = 0.67,95%CI:0.50~0.91).In addition,in the<50 years age group,the distribution frequency difference of the allele of rs9340 was statistically significant between the control group and the NSCLC group(P = 5.07×10-4),indicating that the G allele of rs9340 may be a protective factor for NSCLC(OR = 0.46,95%CI:0.29~0.72).Conclusion The SNP rs9340 in MAPK1 may be associated with the risk of NSCLC.
		                        		
		                        		
		                        		
		                        	
9.Evaluation of antibacterial properties of uniaxial and coaxial minocycline hydrochloride-loaded bone scaffolds
Yijing CAO ; Suiyan WEI ; Shuai ZHAO ; Dongyao LI ; Qin WEI ; Xujing ZHANG ; Yan XU ; Guoqiang XU
Chinese Journal of Tissue Engineering Research 2024;28(10):1547-1553
		                        		
		                        			
		                        			BACKGROUND:Due to the unstable drug release rate of uniaxial bone scaffolds,multi-structure composite printing methods have been sought in and outside China in recent years.Currently,coaxial drug-loaded bone scaffolds,which combine drug-loaded sustained release system with bone transplantation and repair technology,not only replace the defective bone after implantation,but also release drugs slowly,providing a microenvironment conducive to bone formation at the implant site. OBJECTIVE:To explore and assess the in vitro antibacterial properties of uniaxial and coaxial minocycline hydrochloride bone scaffolds. METHODS:Rapid prototyping technology was used to prepare uniaxial hydroxyapatite/silk fibroin-polyvinyl alcohol scaffold,uniaxial hydroxyapatite/silk fibroin-polyvinyl alcohol scaffold,coaxial hydroxyapatite/silk fibroin-polyvinyl alcohol scaffold,and coaxial hydroxyapatite/silk fibroin-polyvinyl alcohol scaffold,respectively,which were named S1,S2,T1 and T2.The morphology,porosity,degradation performance,in vitro sustained-release performance and cytotoxicity of scaffolds were characterized.Four kinds of bone scaffolds were immersed in PBS to prepare the extracts at different time points(1,3,5,7,14,21,and 28 days).The qualitative filter paper was placed into the extract for 24 hours.The filter paper was co-cultured with Porphyromonas gingivalis and Fusobacterium nucleatum for 72 hours.The bacteriostatic effect of four groups of scaffolds was detected by the agar diffusion method. RESULTS AND CONCLUSION:(1)Scaffold characterization:Four groups of scaffolds were well formed.The surface of micro-wires in the S1 and S2 groups was dense and smooth,and the surface of micro-wires in the T1 and T2 groups was rough.Porosity was between 40%-47%and met the requirements of bone scaffolds.Compared with the S2 group,sustained release time was longer in the T2 group.The sustained release concentration of the drug was between 1-10 μg/mL for a long time,which was more conducive to bacteriostasis and osteogenesis.After 10 weeks of immersion in PBS in vitro,the degradation rate of the coaxial printed bone scaffold was faster than that of the corresponding uniaxial printed bone scaffold,and the degradation rate of the coaxial loaded bone scaffold was lower than that of the coaxial non-loaded bone scaffold.The four groups of scaffold extracts were co-cultured with osteoblasts respectively.CCK-8 assay displayed that the cell proliferation rate was greater than 75%,which met the requirements of biocompatibility.(2)In vitro antibacterial effect:S1 and T1 did not have antibacterial activity.S2 and T2 had an obvious antibacterial effect.Under the extraction solution on day 28,the diameter of Porphyromonas gingivalis and Fusobacterium nucleatum inhibition zone in the S2 group was smaller than that in the T2 group(P<0.05).(3)These findings exhibit that hydroxyapatite/silk fibroin-polyvinyl alcohol scaffolds with coaxial minocycline have good physical properties and bacteriostatic properties.
		                        		
		                        		
		                        		
		                        	
10.Finite element analysis of biomechanical effect of lumbar range of motion on the implants after lumbar fusion
Ke LI ; Shuai CAO ; Qiongchi ZHANG ; Xijing HE ; Haopeng LI ; Jie LI
Chinese Journal of Tissue Engineering Research 2024;28(36):5747-5752
		                        		
		                        			
		                        			BACKGROUND:At present,lumbar interbody fusion is widely used in the treatment of a variety of lumbar diseases.However,how to reduce postoperative complications such as pseudarthrosis formation,screw loosening and fracture,and cage failure remains a serious challenge. OBJECTIVE:To analyze the effect of total lumbar range of motion on the stress or strain of bone grafts,cage,and screw-rod system,so as to better guide patients to carry out lumbar activities to reduce the risks of pseudarthrosis formation and instrumentation failure. METHODS:An intact human L1-S1 finite element model was constructed using Mimics,3-Matic,HyperMesh,and Abaqus software and the transforaminal lumbar interbody fusion was simulated.The average strain of the interbody bone grafts and the peak stresses of the cage and screw-rod system were compared before and after applying the bending moment,and the changing trend with the total range of motion was analyzed.The stress nephogram was drawn to observe the stress distribution. RESULTS AND CONCLUSION:(1)Compared with applying the vertical compression load alone,the average strain of the interbody bone grafts,peak stresses of the cage and screw-rod system after applying bending moment increased by 2.6%-55.3%,65.6%-166.8%,and 36.0%-353.4%,respectively.(2)With the increase of total range of motion,the average strain of the interbody bone grafts increased nonlinearly and produced the maximum value under left and right axial rotation,while the peak stresses of the cage and screw-rod system increased linearly and produced the maximum value under left and right lateral bending.(3)The stress distribution of the interbody bone grafts and cage was related to the loading condition.The stress of the screw-rod system was mainly concentrated in the interfaces of the screw-bone and screw-rod.(4)Therefore,increasing axial rotation activity after operation may reduce the risk of pseudarthrosis formation,while reducing lateral bending activity may reduce the failure of the cage and screw-rod system.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail