1.Differences in sputum microbiota based on cure status of patients with nontuberculous mycobacterial pulmonary disease
Noeul KANG ; Su-Young KIM ; Dae Hun KIM ; Byung Woo JHUN
The Korean Journal of Internal Medicine 2025;40(3):449-457
Background/Aims:
To analyze the characteristics of the sputum microbiota of patients with nontuberculous mycobacteria pulmonary disease (NTM-PD) based on treatment status.
Methods:
Twenty-eight sputum samples from 14 patients with NTM-PD, including 14 samples from the microbiologically cured group (7 at baseline and 7 during follow-up) and 14 from the treatment-refractory group (7 at baseline and 7 during follow-up) were included in this study. Bacterial microbiota was analyzed by sequencing the V3–V4 region of the 16S rRNA gene.
Results:
Among the 14 patients, most had infections with Mycobacterium avium complex (n = 6), followed by Mycobacterium abscessus (n = 5); three patients exhibited mixed infection with both organisms. Alpha-diversity was higher in the cured group than in the treatment refractory group in both the baseline sputum (ACE, p = 0.005; Chao1, p = 0.010; Jackknife, p = 0.022, 0.043; Shannon, p = 0.048) and follow-up sputum (ACE, p = 0.018). Linear discriminant analysis effect size revealed that several taxa showed differential distributions based on treatment status. At the species level, Streptococcus pneumoniae, Prevotella melaninogenica, Haemophilus parahaemolyticus, Haemophilus haemolyticus, Fusobacterium nucleatum, Neisseria elongata, and Prevotella denticola were more abundant in sputum from the microbiologically cured group than in that from the refractory group (all p < 0.05).
Conclusions
In contrast to patients with treatment-refractory NTM-PD, those with stable disease without recurrence had higher microbial diversity in their sputum, including several predominant taxa.
2.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
3.Humerus Shaft Fracture Caused by Arm Wrestling Injury in South Korean Military:Surgical Outcome and Radiologic Analysis
Yoo-Sun WON ; Tae-Hong MIN ; Woo Kyoung KWAK ; Jong Seop KIM ; Byung Hyun AHN ; Cheungsoo HA
The Korean Journal of Sports Medicine 2025;43(1):23-29
Purpose:
Arm wrestling is a common strength competition, particularly among young men, including military personnel.While previous studies have examined humeral shaft fractures from arm wrestling or in soldiers, no research has focused on both. This study evaluates the outcomes of dual plating fixation via the anterolateral approach for arm wrestling-induced fractures in soldiers.
Methods:
This retrospective study included 18 male patients (mean age, 21.7 years) treated at the Armed Forces Daejeon Hospital (May 2022–December 2023). Data on rank, radial nerve injury, fracture type (AO-OTA classification), and clinical outcomes (union time, radial nerve recovery, DASH score) were analyzed.
Results:
The cohort included 12 soldiers, two non-commissioned officers, and four officers. Common fracture types were A1 and B1, with four cases of radial nerve palsy. Union occurred at 12.5 weeks, and nerve recovery averaged 15 weeks. No cases of non-union or persistent nerve damage were observed.
Conclusion
Arm wrestling carries a high risk of humeral fractures in soldiers. Awareness and preventive measures should be emphasized. The dual plating fixation technique via the anterolateral approach is highly effective, demonstrating excellent union and recovery outcomes.
4.F‑18 FDG PET/CT Clinical Service Trends in Korea from 2018 to 2022:A National Surveillance Study
Jaesun YOON ; Heejin KIM ; Do Hyun WOO ; Seung Yeop CHAE ; Ji Heui LEE ; Inki LEE ; Ilhan LIM ; Byung Il KIM ; Chang Woon CHOI ; Byung Hyung BYUN
Nuclear Medicine and Molecular Imaging 2025;59(2):117-124
Objectives:
To assess the trends and disparities in the utilization of F-18 fluorodeoxyglucose positron emission tomography/ computed tomography (FDG PET/CT) in Korea between 2018 and 2022, with a focus on disease classification, patient demographics, and regional distribution.
Methods:
This national surveillance retrospective study uses data from the Health Insurance Review and Assessment Service (HIRA) database, which includes all FDG PET/CT examinations conducted in Korea from 2018 to 2022. Disease classifications, cancer types, age groups, gender, and geographic regions were analyzed using descriptive statistics. Utilization rates per 100,000 population were calculated for regional comparisons.
Results:
FDG PET/CT utilization increased by 25.4%, from 174,885 examinations in 2018 to 219,377 in 2022. Older age groups (60 years and above) accounted for the majority of examinations, with males undergoing more examinations than females. Oncology remained the primary indication, with lung, colorectal, and non-Hodgkin lymphoma leading in examination numbers. The number of examinations performed on patients aged 60 and above increased at a higher rate compared to those under 60. Significant geographic disparities were found, with Seoul reporting the highest utilization rate (1,114.3 examinations per 100,000 population), while Gyeongbuk exhibited much lower rate (26.2 examinations per 100,000 population).
Conclusions
This study highlights the growing utilization of FDG PET/CT in Korea, particularly among older adults, with significant gender differences in cancer types. The findings also reveal disparities in FDG PET/CT utilization across regions, indicating varying access to advanced imaging technology.
5.F‑18 FDG PET/CT Clinical Service Trends in Korea from 2018 to 2022:A National Surveillance Study
Jaesun YOON ; Heejin KIM ; Do Hyun WOO ; Seung Yeop CHAE ; Ji Heui LEE ; Inki LEE ; Ilhan LIM ; Byung Il KIM ; Chang Woon CHOI ; Byung Hyung BYUN
Nuclear Medicine and Molecular Imaging 2025;59(2):117-124
Objectives:
To assess the trends and disparities in the utilization of F-18 fluorodeoxyglucose positron emission tomography/ computed tomography (FDG PET/CT) in Korea between 2018 and 2022, with a focus on disease classification, patient demographics, and regional distribution.
Methods:
This national surveillance retrospective study uses data from the Health Insurance Review and Assessment Service (HIRA) database, which includes all FDG PET/CT examinations conducted in Korea from 2018 to 2022. Disease classifications, cancer types, age groups, gender, and geographic regions were analyzed using descriptive statistics. Utilization rates per 100,000 population were calculated for regional comparisons.
Results:
FDG PET/CT utilization increased by 25.4%, from 174,885 examinations in 2018 to 219,377 in 2022. Older age groups (60 years and above) accounted for the majority of examinations, with males undergoing more examinations than females. Oncology remained the primary indication, with lung, colorectal, and non-Hodgkin lymphoma leading in examination numbers. The number of examinations performed on patients aged 60 and above increased at a higher rate compared to those under 60. Significant geographic disparities were found, with Seoul reporting the highest utilization rate (1,114.3 examinations per 100,000 population), while Gyeongbuk exhibited much lower rate (26.2 examinations per 100,000 population).
Conclusions
This study highlights the growing utilization of FDG PET/CT in Korea, particularly among older adults, with significant gender differences in cancer types. The findings also reveal disparities in FDG PET/CT utilization across regions, indicating varying access to advanced imaging technology.
6.Differences in sputum microbiota based on cure status of patients with nontuberculous mycobacterial pulmonary disease
Noeul KANG ; Su-Young KIM ; Dae Hun KIM ; Byung Woo JHUN
The Korean Journal of Internal Medicine 2025;40(3):449-457
Background/Aims:
To analyze the characteristics of the sputum microbiota of patients with nontuberculous mycobacteria pulmonary disease (NTM-PD) based on treatment status.
Methods:
Twenty-eight sputum samples from 14 patients with NTM-PD, including 14 samples from the microbiologically cured group (7 at baseline and 7 during follow-up) and 14 from the treatment-refractory group (7 at baseline and 7 during follow-up) were included in this study. Bacterial microbiota was analyzed by sequencing the V3–V4 region of the 16S rRNA gene.
Results:
Among the 14 patients, most had infections with Mycobacterium avium complex (n = 6), followed by Mycobacterium abscessus (n = 5); three patients exhibited mixed infection with both organisms. Alpha-diversity was higher in the cured group than in the treatment refractory group in both the baseline sputum (ACE, p = 0.005; Chao1, p = 0.010; Jackknife, p = 0.022, 0.043; Shannon, p = 0.048) and follow-up sputum (ACE, p = 0.018). Linear discriminant analysis effect size revealed that several taxa showed differential distributions based on treatment status. At the species level, Streptococcus pneumoniae, Prevotella melaninogenica, Haemophilus parahaemolyticus, Haemophilus haemolyticus, Fusobacterium nucleatum, Neisseria elongata, and Prevotella denticola were more abundant in sputum from the microbiologically cured group than in that from the refractory group (all p < 0.05).
Conclusions
In contrast to patients with treatment-refractory NTM-PD, those with stable disease without recurrence had higher microbial diversity in their sputum, including several predominant taxa.
7.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
8.Humerus Shaft Fracture Caused by Arm Wrestling Injury in South Korean Military:Surgical Outcome and Radiologic Analysis
Yoo-Sun WON ; Tae-Hong MIN ; Woo Kyoung KWAK ; Jong Seop KIM ; Byung Hyun AHN ; Cheungsoo HA
The Korean Journal of Sports Medicine 2025;43(1):23-29
Purpose:
Arm wrestling is a common strength competition, particularly among young men, including military personnel.While previous studies have examined humeral shaft fractures from arm wrestling or in soldiers, no research has focused on both. This study evaluates the outcomes of dual plating fixation via the anterolateral approach for arm wrestling-induced fractures in soldiers.
Methods:
This retrospective study included 18 male patients (mean age, 21.7 years) treated at the Armed Forces Daejeon Hospital (May 2022–December 2023). Data on rank, radial nerve injury, fracture type (AO-OTA classification), and clinical outcomes (union time, radial nerve recovery, DASH score) were analyzed.
Results:
The cohort included 12 soldiers, two non-commissioned officers, and four officers. Common fracture types were A1 and B1, with four cases of radial nerve palsy. Union occurred at 12.5 weeks, and nerve recovery averaged 15 weeks. No cases of non-union or persistent nerve damage were observed.
Conclusion
Arm wrestling carries a high risk of humeral fractures in soldiers. Awareness and preventive measures should be emphasized. The dual plating fixation technique via the anterolateral approach is highly effective, demonstrating excellent union and recovery outcomes.
9.A randomized controlled trial comparing liquid skin adhesives and staplers for surgical wound management
Hyeon Woo BAE ; Seung Yoon YANG ; Ga Yoon KU ; Sohye LEE ; Eun-Joo JUNG ; Seulkee PARK ; Yoon Bin JUNG ; Jihong KIM ; Byung Soh MIN
Annals of Surgical Treatment and Research 2025;108(3):143-149
Purpose:
Despite the widespread use of liquid skin adhesives (LSA), concerns persist regarding the increase in wound care costs. This study aimed to investigate the cost-effectiveness of LSA for surgical wound management.
Methods:
In this prospective, open-label, single-center randomized controlled trial, adults aged 19 years and older who were scheduled for elective minimally invasive colorectal surgeries were included. The participants were randomly divided into 2 groups: an n-butyl cyanoacrylate skin adhesive was used in the experimental group (LSA group), while a surgical skin stapler was employed in the control group (stapler group). The primary outcome measure was the sum of the total time required for wound management.
Results:
A total of 58 patients were randomly assigned to 2 groups, with 29 patients in each group. The findings revealed comparable wound complication rates in the 2 groups (8 out of 29 in the LSA group vs. 5 out of 29 in the stapler group, P = 0.530). Notably, the LSA group had a significantly shorter wound management time (median 235 seconds vs. 1,201 seconds, P < 0.001) and similar wound management cost (median US dollar [USD] 50.6 vs. USD 54.6, P = 0.529) compared to the stapler group. Subgroup analysis showed that the LSA group had a shorter management time for uncomplicated wounds and a lower cost for complicated wounds.
Conclusion
LSA not only provides a safe alternative but also offers a resource-efficient option for wound management compared to staplers.
10.F‑18 FDG PET/CT Clinical Service Trends in Korea from 2018 to 2022:A National Surveillance Study
Jaesun YOON ; Heejin KIM ; Do Hyun WOO ; Seung Yeop CHAE ; Ji Heui LEE ; Inki LEE ; Ilhan LIM ; Byung Il KIM ; Chang Woon CHOI ; Byung Hyung BYUN
Nuclear Medicine and Molecular Imaging 2025;59(2):117-124
Objectives:
To assess the trends and disparities in the utilization of F-18 fluorodeoxyglucose positron emission tomography/ computed tomography (FDG PET/CT) in Korea between 2018 and 2022, with a focus on disease classification, patient demographics, and regional distribution.
Methods:
This national surveillance retrospective study uses data from the Health Insurance Review and Assessment Service (HIRA) database, which includes all FDG PET/CT examinations conducted in Korea from 2018 to 2022. Disease classifications, cancer types, age groups, gender, and geographic regions were analyzed using descriptive statistics. Utilization rates per 100,000 population were calculated for regional comparisons.
Results:
FDG PET/CT utilization increased by 25.4%, from 174,885 examinations in 2018 to 219,377 in 2022. Older age groups (60 years and above) accounted for the majority of examinations, with males undergoing more examinations than females. Oncology remained the primary indication, with lung, colorectal, and non-Hodgkin lymphoma leading in examination numbers. The number of examinations performed on patients aged 60 and above increased at a higher rate compared to those under 60. Significant geographic disparities were found, with Seoul reporting the highest utilization rate (1,114.3 examinations per 100,000 population), while Gyeongbuk exhibited much lower rate (26.2 examinations per 100,000 population).
Conclusions
This study highlights the growing utilization of FDG PET/CT in Korea, particularly among older adults, with significant gender differences in cancer types. The findings also reveal disparities in FDG PET/CT utilization across regions, indicating varying access to advanced imaging technology.

Result Analysis
Print
Save
E-mail