1.F‑18 FDG PET/CT Clinical Service Trends in Korea from 2018 to 2022:A National Surveillance Study
Jaesun YOON ; Heejin KIM ; Do Hyun WOO ; Seung Yeop CHAE ; Ji Heui LEE ; Inki LEE ; Ilhan LIM ; Byung Il KIM ; Chang Woon CHOI ; Byung Hyung BYUN
Nuclear Medicine and Molecular Imaging 2025;59(2):117-124
Objectives:
To assess the trends and disparities in the utilization of F-18 fluorodeoxyglucose positron emission tomography/ computed tomography (FDG PET/CT) in Korea between 2018 and 2022, with a focus on disease classification, patient demographics, and regional distribution.
Methods:
This national surveillance retrospective study uses data from the Health Insurance Review and Assessment Service (HIRA) database, which includes all FDG PET/CT examinations conducted in Korea from 2018 to 2022. Disease classifications, cancer types, age groups, gender, and geographic regions were analyzed using descriptive statistics. Utilization rates per 100,000 population were calculated for regional comparisons.
Results:
FDG PET/CT utilization increased by 25.4%, from 174,885 examinations in 2018 to 219,377 in 2022. Older age groups (60 years and above) accounted for the majority of examinations, with males undergoing more examinations than females. Oncology remained the primary indication, with lung, colorectal, and non-Hodgkin lymphoma leading in examination numbers. The number of examinations performed on patients aged 60 and above increased at a higher rate compared to those under 60. Significant geographic disparities were found, with Seoul reporting the highest utilization rate (1,114.3 examinations per 100,000 population), while Gyeongbuk exhibited much lower rate (26.2 examinations per 100,000 population).
Conclusions
This study highlights the growing utilization of FDG PET/CT in Korea, particularly among older adults, with significant gender differences in cancer types. The findings also reveal disparities in FDG PET/CT utilization across regions, indicating varying access to advanced imaging technology.
2.Nephrogenic diabetes insipidus secondary to COVID-19 infection in a patient on lithium medication: a case report
Jong-In CHOI ; Somin LEE ; Hyun Lee KIM ; Jong-Hoon CHUNG ; Byung Chul SHIN ; Youngmin YOON
Journal of the Korean Society of Emergency Medicine 2025;36(1):41-44
Nephrogenic diabetes insipidus (NDI) is characterized by polyuria and polydipsia, high serum osmolality, and low urine osmolality because of resistance to antidiuretic hormone. Lithium is commonly used to treat psychiatric disorders, and NDI is one of the common renal side effects of lithium therapy. On the other hand, NDI induced by lithium medication in a patient after a coronavirus disease-19 (COVID-19) infection has not been reported. This paper presents a patient who developed new-onset NDI secondary to a COVID-19 infection despite being on a stable lithium dose for several years. This case highlights the importance of considering a COVID-19 infection as a possible cause of NDI in patients taking lithium medication.
3.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Long-Term Incidence of Gastrointestinal Bleeding Following Ischemic Stroke
Jun Yup KIM ; Beom Joon KIM ; Jihoon KANG ; Do Yeon KIM ; Moon-Ku HAN ; Seong-Eun KIM ; Heeyoung LEE ; Jong-Moo PARK ; Kyusik KANG ; Soo Joo LEE ; Jae Guk KIM ; Jae-Kwan CHA ; Dae-Hyun KIM ; Tai Hwan PARK ; Kyungbok LEE ; Hong-Kyun PARK ; Yong-Jin CHO ; Keun-Sik HONG ; Kang-Ho CHOI ; Joon-Tae KIM ; Dong-Eog KIM ; Jay Chol CHOI ; Mi-Sun OH ; Kyung-Ho YU ; Byung-Chul LEE ; Kwang-Yeol PARK ; Ji Sung LEE ; Sujung JANG ; Jae Eun CHAE ; Juneyoung LEE ; Min-Surk KYE ; Philip B. GORELICK ; Hee-Joon BAE ;
Journal of Stroke 2025;27(1):102-112
Background:
and Purpose Previous research on patients with acute ischemic stroke (AIS) has shown a 0.5% incidence of major gastrointestinal bleeding (GIB) requiring blood transfusion during hospitalization. The existing literature has insufficiently explored the long-term incidence in this population despite the decremental impact of GIB on stroke outcomes.
Methods:
We analyzed the data from a cohort of patients with AIS admitted to 14 hospitals as part of a nationwide multicenter prospective stroke registry between 2011 and 2013. These patients were followed up for up to 6 years. The occurrence of major GIB events, defined as GIB necessitating at least two units of blood transfusion, was tracked using the National Health Insurance Service claims data.
Results:
Among 10,818 patients with AIS (male, 59%; mean age, 68±13 years), 947 (8.8%) experienced 1,224 episodes of major GIB over a median follow-up duration of 3.1 years. Remarkably, 20% of 947 patients experienced multiple episodes of major GIB. The incidence peaked in the first month after AIS, reaching 19.2 per 100 person-years, and gradually decreased to approximately one-sixth of this rate by the 2nd year with subsequent stabilization. Multivariable analysis identified the following predictors of major GIB: anemia, estimated glomerular filtration rate <60 mL/min/1.73 m2 , and a 3-month modified Rankin Scale score of ≥4.
Conclusion
Patients with AIS are susceptible to major GIB, particularly in the first month after the onset of AIS, with the risk decreasing thereafter. Implementing preventive strategies may be important, especially for patients with anemia and impaired renal function at stroke onset and those with a disabling stroke.
7.F‑18 FDG PET/CT Clinical Service Trends in Korea from 2018 to 2022:A National Surveillance Study
Jaesun YOON ; Heejin KIM ; Do Hyun WOO ; Seung Yeop CHAE ; Ji Heui LEE ; Inki LEE ; Ilhan LIM ; Byung Il KIM ; Chang Woon CHOI ; Byung Hyung BYUN
Nuclear Medicine and Molecular Imaging 2025;59(2):117-124
Objectives:
To assess the trends and disparities in the utilization of F-18 fluorodeoxyglucose positron emission tomography/ computed tomography (FDG PET/CT) in Korea between 2018 and 2022, with a focus on disease classification, patient demographics, and regional distribution.
Methods:
This national surveillance retrospective study uses data from the Health Insurance Review and Assessment Service (HIRA) database, which includes all FDG PET/CT examinations conducted in Korea from 2018 to 2022. Disease classifications, cancer types, age groups, gender, and geographic regions were analyzed using descriptive statistics. Utilization rates per 100,000 population were calculated for regional comparisons.
Results:
FDG PET/CT utilization increased by 25.4%, from 174,885 examinations in 2018 to 219,377 in 2022. Older age groups (60 years and above) accounted for the majority of examinations, with males undergoing more examinations than females. Oncology remained the primary indication, with lung, colorectal, and non-Hodgkin lymphoma leading in examination numbers. The number of examinations performed on patients aged 60 and above increased at a higher rate compared to those under 60. Significant geographic disparities were found, with Seoul reporting the highest utilization rate (1,114.3 examinations per 100,000 population), while Gyeongbuk exhibited much lower rate (26.2 examinations per 100,000 population).
Conclusions
This study highlights the growing utilization of FDG PET/CT in Korea, particularly among older adults, with significant gender differences in cancer types. The findings also reveal disparities in FDG PET/CT utilization across regions, indicating varying access to advanced imaging technology.
8.F‑18 FDG PET/CT Clinical Service Trends in Korea from 2018 to 2022:A National Surveillance Study
Jaesun YOON ; Heejin KIM ; Do Hyun WOO ; Seung Yeop CHAE ; Ji Heui LEE ; Inki LEE ; Ilhan LIM ; Byung Il KIM ; Chang Woon CHOI ; Byung Hyung BYUN
Nuclear Medicine and Molecular Imaging 2025;59(2):117-124
Objectives:
To assess the trends and disparities in the utilization of F-18 fluorodeoxyglucose positron emission tomography/ computed tomography (FDG PET/CT) in Korea between 2018 and 2022, with a focus on disease classification, patient demographics, and regional distribution.
Methods:
This national surveillance retrospective study uses data from the Health Insurance Review and Assessment Service (HIRA) database, which includes all FDG PET/CT examinations conducted in Korea from 2018 to 2022. Disease classifications, cancer types, age groups, gender, and geographic regions were analyzed using descriptive statistics. Utilization rates per 100,000 population were calculated for regional comparisons.
Results:
FDG PET/CT utilization increased by 25.4%, from 174,885 examinations in 2018 to 219,377 in 2022. Older age groups (60 years and above) accounted for the majority of examinations, with males undergoing more examinations than females. Oncology remained the primary indication, with lung, colorectal, and non-Hodgkin lymphoma leading in examination numbers. The number of examinations performed on patients aged 60 and above increased at a higher rate compared to those under 60. Significant geographic disparities were found, with Seoul reporting the highest utilization rate (1,114.3 examinations per 100,000 population), while Gyeongbuk exhibited much lower rate (26.2 examinations per 100,000 population).
Conclusions
This study highlights the growing utilization of FDG PET/CT in Korea, particularly among older adults, with significant gender differences in cancer types. The findings also reveal disparities in FDG PET/CT utilization across regions, indicating varying access to advanced imaging technology.
9.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
10.Nephrogenic diabetes insipidus secondary to COVID-19 infection in a patient on lithium medication: a case report
Jong-In CHOI ; Somin LEE ; Hyun Lee KIM ; Jong-Hoon CHUNG ; Byung Chul SHIN ; Youngmin YOON
Journal of the Korean Society of Emergency Medicine 2025;36(1):41-44
Nephrogenic diabetes insipidus (NDI) is characterized by polyuria and polydipsia, high serum osmolality, and low urine osmolality because of resistance to antidiuretic hormone. Lithium is commonly used to treat psychiatric disorders, and NDI is one of the common renal side effects of lithium therapy. On the other hand, NDI induced by lithium medication in a patient after a coronavirus disease-19 (COVID-19) infection has not been reported. This paper presents a patient who developed new-onset NDI secondary to a COVID-19 infection despite being on a stable lithium dose for several years. This case highlights the importance of considering a COVID-19 infection as a possible cause of NDI in patients taking lithium medication.

Result Analysis
Print
Save
E-mail