1.A multicenter micro-costing analysis of flexible cystoscopic procedures in Korea
Uiemo JE ; Woong Kyu HAN ; Hee-Kyo JEONG ; Hankil LEE ; Kwang Suk LEE ; Sung Ku KANG ; Byeong-Ju KWON ; Sung-Uk KUH
Investigative and Clinical Urology 2025;66(1):87-96
Purpose:
This study aims to develop and implement an economic evaluation using a micro-costing approach to provide a precise and transparent analysis of the direct costs of cystoscopic procedures in Korean hospitals. The study seeks to identify key cost components and evaluate whether current reimbursement rates accurately reflect these direct costs.
Materials and Methods:
Significant variations in cost items were identified across different studies. An economic evaluation was conducted using a micro-costing methodology for the cost analysis of cystoscopic procedures, developed through literature review, data collection from studies, and expert consultations.
Results:
Gangnam Severance Hospital (GSH) performed 2,188 cystoscopic procedures, including 1,847 cystoscopies and 341 JJ stent removals, with average costs of $100.8 and $110.6, respectively. At National Health Insurance Service Ilsan Hospital (NHIMC), 1,463 procedures were performed, including 1,167 cystoscopies and 296 JJ stent removals, with average costs of $119.2 and $125.3. Cystoscopy costs at GSH were driven by reprocessing ($45.8, 45.4%) and equipment ($33.1, 32.9%), while NHIMC’s were $52.5 (44.0%) for equipment and $48.7 (40.8%) for reprocessing. Both hospitals incurred financial losses, with NHIS (National Health Insurance Service) covering only about 71.7% and 60.6% of costs for cystoscopy, and 71.0% and 62.7% for JJ stent removal.
Conclusions
The significant discrepancy between HIRA (Health Insurance Review & Assessment Service)’s estimated costs and those identified here suggests that current fees for cystoscopic procedures may be underestimated and require reassessment.Given the results, reevaluating these rates is essential to ensure fair compensation for healthcare providers and to deliver optimal patient care.
2.Toxicological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Yiseul CHOI ; Inki LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):201-210
Following the previous study, which investigated the pharmacological properties of the Technekitty injection (Tc-99m), the toxicity of a single intravenous administration of the Technekittyinjection (Tc-99m) and the side effects that may occur at the diagnostic dose were confirmed.The Technekitty injection (Tc-99m) was administered intravenously once at a dose of 0, 0.67, 2.0, and 6.0 mCi/kg to 5 male and female rats per group. Mortality, general symptom obser-vation, and weight measurement were performed for 2 weeks, followed by observation of autopsy findings. There were no deaths, and no statistically significant weight change was observed. No abnormal systemic signs related to the Technekitty injection (Tc-99m) were observed. These results confirmed that Technekitty injection (Tc-99m) can be safely admin-istered intravenously at doses up to 6.0 mCi/kg. Additionally, technetium-99m at an average dose of 2 mCi (74 MBq) has been verified as a diagnostic dose without adverse effects, al-lowing the Technekitty injection (Tc-99m) to be used safely without side effects at this dosage.This study demonstrates that the Technekitty injection (Tc-99m) has a wide safety margin, supporting its potential for clinical application. Moreover, these findings align with the nonclin-ical safety standards for radiopharmaceuticals, reinforcing its utility in veterinary medicine.The Technekitty injection (Tc-99m) is expected to be applicable for clinical diagnosis as a vet-erinary drug in Korea.
3.Pharmacological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Jisu SUN ; Hye Kyung CHUNG ; Yong Jin LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):185-199
Thyroid scanning using technetium-99m ( 99mTc) is the gold standard for diagnosing feline hyperthyroidism. In cats with an overactive thyroid, a thyroid scan is the most appropriate imaging technique to detect and localize any hyperfunctional adenomatous thyroid tissue. In this study, the pharmacological properties of the Technekitty injection (Tc-99m), developed as a diagnostic agent for feline hyperthyroidism using 99mTc as an active ingredient, were tested in FRTL-5 thyroid follicular cell line and ICR mice. The percentage of cell uptake of the Tc-99m in FRTL-5 thyroid cells was 0.182 ± 0.018%, which was about 6 times higher compared to Clone 9 hepatocytes. This uptake decreased by 38.2% due to competitive inhibition by iodine (sodium iodide). In tissue distribution tests by using ICR mice, the highest distribution was observed in the liver, kidneys, spleen, lungs, and femur at 0.083 hours after administration, and this distribution decreased as the compound was excreted through the kidneys, the pri-mary excretory organ. Maximum distribution was confirmed at 1 hour in the small intestine, 6hours in the large intestine, and 2 hours in the thyroid gland. Additionally, the total amount excreted through urine and feces over 48 hours (2 days) was 78.80% of the injected dose, with 37.70% (47.84% of the total excretion) excreted through urine and 41.10% (52.16% of the total excretion) through feces. In conclusion, the Tc-99m has the same mechanism of action, potency, absorption, distribution, metabolism, and excretion characteristics as 99mTc used for feline hyperthyroidism in the United States, Europe, and other countries, because the Technekitty injection (Tc-99m) contains 99mTc as its sole active ingredient. Based on these results, the Technekitty injection (Tc-99m) is expected to be safely used in the clinical diagnosis of feline hyperthyroidism.
4.Toxicological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Yiseul CHOI ; Inki LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):201-210
Following the previous study, which investigated the pharmacological properties of the Technekitty injection (Tc-99m), the toxicity of a single intravenous administration of the Technekittyinjection (Tc-99m) and the side effects that may occur at the diagnostic dose were confirmed.The Technekitty injection (Tc-99m) was administered intravenously once at a dose of 0, 0.67, 2.0, and 6.0 mCi/kg to 5 male and female rats per group. Mortality, general symptom obser-vation, and weight measurement were performed for 2 weeks, followed by observation of autopsy findings. There were no deaths, and no statistically significant weight change was observed. No abnormal systemic signs related to the Technekitty injection (Tc-99m) were observed. These results confirmed that Technekitty injection (Tc-99m) can be safely admin-istered intravenously at doses up to 6.0 mCi/kg. Additionally, technetium-99m at an average dose of 2 mCi (74 MBq) has been verified as a diagnostic dose without adverse effects, al-lowing the Technekitty injection (Tc-99m) to be used safely without side effects at this dosage.This study demonstrates that the Technekitty injection (Tc-99m) has a wide safety margin, supporting its potential for clinical application. Moreover, these findings align with the nonclin-ical safety standards for radiopharmaceuticals, reinforcing its utility in veterinary medicine.The Technekitty injection (Tc-99m) is expected to be applicable for clinical diagnosis as a vet-erinary drug in Korea.
5.Pharmacological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Jisu SUN ; Hye Kyung CHUNG ; Yong Jin LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):185-199
Thyroid scanning using technetium-99m ( 99mTc) is the gold standard for diagnosing feline hyperthyroidism. In cats with an overactive thyroid, a thyroid scan is the most appropriate imaging technique to detect and localize any hyperfunctional adenomatous thyroid tissue. In this study, the pharmacological properties of the Technekitty injection (Tc-99m), developed as a diagnostic agent for feline hyperthyroidism using 99mTc as an active ingredient, were tested in FRTL-5 thyroid follicular cell line and ICR mice. The percentage of cell uptake of the Tc-99m in FRTL-5 thyroid cells was 0.182 ± 0.018%, which was about 6 times higher compared to Clone 9 hepatocytes. This uptake decreased by 38.2% due to competitive inhibition by iodine (sodium iodide). In tissue distribution tests by using ICR mice, the highest distribution was observed in the liver, kidneys, spleen, lungs, and femur at 0.083 hours after administration, and this distribution decreased as the compound was excreted through the kidneys, the pri-mary excretory organ. Maximum distribution was confirmed at 1 hour in the small intestine, 6hours in the large intestine, and 2 hours in the thyroid gland. Additionally, the total amount excreted through urine and feces over 48 hours (2 days) was 78.80% of the injected dose, with 37.70% (47.84% of the total excretion) excreted through urine and 41.10% (52.16% of the total excretion) through feces. In conclusion, the Tc-99m has the same mechanism of action, potency, absorption, distribution, metabolism, and excretion characteristics as 99mTc used for feline hyperthyroidism in the United States, Europe, and other countries, because the Technekitty injection (Tc-99m) contains 99mTc as its sole active ingredient. Based on these results, the Technekitty injection (Tc-99m) is expected to be safely used in the clinical diagnosis of feline hyperthyroidism.
6.Toxicological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Yiseul CHOI ; Inki LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):201-210
Following the previous study, which investigated the pharmacological properties of the Technekitty injection (Tc-99m), the toxicity of a single intravenous administration of the Technekittyinjection (Tc-99m) and the side effects that may occur at the diagnostic dose were confirmed.The Technekitty injection (Tc-99m) was administered intravenously once at a dose of 0, 0.67, 2.0, and 6.0 mCi/kg to 5 male and female rats per group. Mortality, general symptom obser-vation, and weight measurement were performed for 2 weeks, followed by observation of autopsy findings. There were no deaths, and no statistically significant weight change was observed. No abnormal systemic signs related to the Technekitty injection (Tc-99m) were observed. These results confirmed that Technekitty injection (Tc-99m) can be safely admin-istered intravenously at doses up to 6.0 mCi/kg. Additionally, technetium-99m at an average dose of 2 mCi (74 MBq) has been verified as a diagnostic dose without adverse effects, al-lowing the Technekitty injection (Tc-99m) to be used safely without side effects at this dosage.This study demonstrates that the Technekitty injection (Tc-99m) has a wide safety margin, supporting its potential for clinical application. Moreover, these findings align with the nonclin-ical safety standards for radiopharmaceuticals, reinforcing its utility in veterinary medicine.The Technekitty injection (Tc-99m) is expected to be applicable for clinical diagnosis as a vet-erinary drug in Korea.
7.Pharmacological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Jisu SUN ; Hye Kyung CHUNG ; Yong Jin LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):185-199
Thyroid scanning using technetium-99m ( 99mTc) is the gold standard for diagnosing feline hyperthyroidism. In cats with an overactive thyroid, a thyroid scan is the most appropriate imaging technique to detect and localize any hyperfunctional adenomatous thyroid tissue. In this study, the pharmacological properties of the Technekitty injection (Tc-99m), developed as a diagnostic agent for feline hyperthyroidism using 99mTc as an active ingredient, were tested in FRTL-5 thyroid follicular cell line and ICR mice. The percentage of cell uptake of the Tc-99m in FRTL-5 thyroid cells was 0.182 ± 0.018%, which was about 6 times higher compared to Clone 9 hepatocytes. This uptake decreased by 38.2% due to competitive inhibition by iodine (sodium iodide). In tissue distribution tests by using ICR mice, the highest distribution was observed in the liver, kidneys, spleen, lungs, and femur at 0.083 hours after administration, and this distribution decreased as the compound was excreted through the kidneys, the pri-mary excretory organ. Maximum distribution was confirmed at 1 hour in the small intestine, 6hours in the large intestine, and 2 hours in the thyroid gland. Additionally, the total amount excreted through urine and feces over 48 hours (2 days) was 78.80% of the injected dose, with 37.70% (47.84% of the total excretion) excreted through urine and 41.10% (52.16% of the total excretion) through feces. In conclusion, the Tc-99m has the same mechanism of action, potency, absorption, distribution, metabolism, and excretion characteristics as 99mTc used for feline hyperthyroidism in the United States, Europe, and other countries, because the Technekitty injection (Tc-99m) contains 99mTc as its sole active ingredient. Based on these results, the Technekitty injection (Tc-99m) is expected to be safely used in the clinical diagnosis of feline hyperthyroidism.
8.Corrigendum: Clinicopathological characteristics of extrahepatic biliary neuroendocrine neoplasms in the gallbladder, extrahepatic biliary tract, and ampulla of Vater:A single-center cross-sectional study
Young Mok PARK ; Hyung Il SEO ; Byeong Gwan NOH ; Suk KIM ; Seung Baek HONG ; Nam Kyung LEE ; Dong Uk KIM ; Sung Yong HAN
Annals of Hepato-Biliary-Pancreatic Surgery 2024;28(1):114-114
9.Practice guidelines for managing extrahepatic biliary tract cancers
Hyung Sun KIM ; Mee Joo KANG ; Jingu KANG ; Kyubo KIM ; Bohyun KIM ; Seong-Hun KIM ; Soo Jin KIM ; Yong-Il KIM ; Joo Young KIM ; Jin Sil KIM ; Haeryoung KIM ; Hyo Jung KIM ; Ji Hae NAHM ; Won Suk PARK ; Eunkyu PARK ; Joo Kyung PARK ; Jin Myung PARK ; Byeong Jun SONG ; Yong Chan SHIN ; Keun Soo AHN ; Sang Myung WOO ; Jeong Il YU ; Changhoon YOO ; Kyoungbun LEE ; Dong Ho LEE ; Myung Ah LEE ; Seung Eun LEE ; Ik Jae LEE ; Huisong LEE ; Jung Ho IM ; Kee-Taek JANG ; Hye Young JANG ; Sun-Young JUN ; Hong Jae CHON ; Min Kyu JUNG ; Yong Eun CHUNG ; Jae Uk CHONG ; Eunae CHO ; Eui Kyu CHIE ; Sae Byeol CHOI ; Seo-Yeon CHOI ; Seong Ji CHOI ; Joon Young CHOI ; Hye-Jeong CHOI ; Seung-Mo HONG ; Ji Hyung HONG ; Tae Ho HONG ; Shin Hye HWANG ; In Gyu HWANG ; Joon Seong PARK
Annals of Hepato-Biliary-Pancreatic Surgery 2024;28(2):161-202
Background:
s/Aims: Reported incidence of extrahepatic bile duct cancer is higher in Asians than in Western populations. Korea, in particular, is one of the countries with the highest incidence rates of extrahepatic bile duct cancer in the world. Although research and innovative therapeutic modalities for extrahepatic bile duct cancer are emerging, clinical guidelines are currently unavailable in Korea. The Korean Society of Hepato-Biliary-Pancreatic Surgery in collaboration with related societies (Korean Pancreatic and Biliary Surgery Society, Korean Society of Abdominal Radiology, Korean Society of Medical Oncology, Korean Society of Radiation Oncology, Korean Society of Pathologists, and Korean Society of Nuclear Medicine) decided to establish clinical guideline for extrahepatic bile duct cancer in June 2021.
Methods:
Contents of the guidelines were developed through subgroup meetings for each key question and a preliminary draft was finalized through a Clinical Guidelines Committee workshop.
Results:
In November 2021, the finalized draft was presented for public scrutiny during a formal hearing.
Conclusions
The extrahepatic guideline committee believed that this guideline could be helpful in the treatment of patients.
10.Re-Assessment of Applicability of Greulich and Pyle-Based Bone Age to Korean Children Using Manual and Deep Learning-Based Automated Method
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Pyeong Hwa KIM ; Boram BAK ; Byeong Uk BAE ; Jinkyeong SUNG ; Hwa Jung KIM ; Ah Young JUNG ; Young Ah CHO ; Jin Seong LEE
Yonsei Medical Journal 2022;63(7):683-691
Purpose:
To evaluate the applicability of Greulich-Pyle (GP) standards to bone age (BA) assessment in healthy Korean children using manual and deep learning-based methods.
Materials and Methods:
We collected 485 hand radiographs of healthy children aged 2–17 years (262 boys) between 2008 and 2017. Based on GP method, BA was assessed manually by two radiologists and automatically by two deep learning-based BA assessment (DLBAA), which estimated GP-assigned (original model) and optimal (modified model) BAs. Estimated BA was compared to chronological age (CA) using intraclass correlation (ICC), Bland-Altman analysis, linear regression, mean absolute error, and root mean square error. The proportion of children showing a difference >12 months between the estimated BA and CA was calculated.
Results:
CA and all estimated BA showed excellent agreement (ICC ≥0.978, p<0.001) and significant positive linear correlations (R2 ≥0.935, p<0.001). The estimated BA of all methods showed systematic bias and tended to be lower than CA in younger patients, and higher than CA in older patients (regression slopes ≤-0.11, p<0.001). The mean absolute error of radiologist 1, radiologist 2, original, and modified DLBAA models were 13.09, 13.12, 11.52, and 11.31 months, respectively. The difference between estimated BA and CA was >12 months in 44.3%, 44.5%, 39.2%, and 36.1% for radiologist 1, radiologist 2, original, and modified DLBAA models, respectively.
Conclusion
Contemporary healthy Korean children showed different rates of skeletal development than GP standard-BA, and systemic bias should be considered when determining children’s skeletal maturation.

Result Analysis
Print
Save
E-mail