1.A Propensity Score-Matched Cohort Study Comparing 3 Different Spine Pedicle Screw Fixation Methods: Freehand, Fluoroscopy-Guided, and Robot-Assisted Techniques
Yoon Ha HWANG ; Byeong-Jin HA ; Hyung Cheol KIM ; Byung Ho LEE ; Jeong-Yoon PARK ; Dong-Kyu CHIN ; Seong YI
Neurospine 2024;21(1):83-94
		                        		
		                        			 Objective:
		                        			This study aimed to compare the accuracy of robotic spine surgery and conventional pedicle screw fixation in lumbar degenerative disease. We evaluated clinical and radiological outcomes to demonstrate the noninferiority of robotic surgery. 
		                        		
		                        			Methods:
		                        			This study employed propensity score matching and included 3 groups: robot-assisted mini-open posterior lumbar interbody fusion (PLIF) (robotic surgery, RS), c-arm guided minimally invasive surgery transforaminal lumbar interbody fusion (C-arm guidance, CG), and freehand open PLIF (free of guidance, FG) (54 patients each). The mean follow-up period was 2.2 years. The preoperative spine condition was considered. Accuracy was evaluated using the Gertzbein-Robbins scale (GRS score) and Babu classification (Babu score). Radiological outcomes included adjacent segmental disease (ASD) and mechanical failure. Clinical outcomes were assessed based on the visual analogue scale, Oswestry Disability Index, 36-item Short Form health survey, and clinical ASD rate. 
		                        		
		                        			Results:
		                        			Accuracy was higher in the RS group (p < 0.01) than in other groups. The GRS score was lower in the CG group, whereas the Babu score was lower in the FG group compared with the RS group. No significant differences were observed in radiological and clinical outcomes among the 3 groups. Regression analysis identified preoperative facet degeneration, GRS and Babu scores as significant variables for radiological and clinical ASD. Mechanical failure was influenced by the GRS score and patients’ age. 
		                        		
		                        			Conclusion
		                        			This study showed the superior accuracy of robotic spine surgery compared with conventional techniques. When combined with minimally invasive surgery, robotic surgery is advantageous with reduced ligament and muscle damage associated with traditional open procedures. 
		                        		
		                        		
		                        		
		                        	
2.A Propensity Score-Matched Cohort Study Comparing 3 Different Spine Pedicle Screw Fixation Methods: Freehand, Fluoroscopy-Guided, and Robot-Assisted Techniques
Yoon Ha HWANG ; Byeong-Jin HA ; Hyung Cheol KIM ; Byung Ho LEE ; Jeong-Yoon PARK ; Dong-Kyu CHIN ; Seong YI
Neurospine 2024;21(1):83-94
		                        		
		                        			 Objective:
		                        			This study aimed to compare the accuracy of robotic spine surgery and conventional pedicle screw fixation in lumbar degenerative disease. We evaluated clinical and radiological outcomes to demonstrate the noninferiority of robotic surgery. 
		                        		
		                        			Methods:
		                        			This study employed propensity score matching and included 3 groups: robot-assisted mini-open posterior lumbar interbody fusion (PLIF) (robotic surgery, RS), c-arm guided minimally invasive surgery transforaminal lumbar interbody fusion (C-arm guidance, CG), and freehand open PLIF (free of guidance, FG) (54 patients each). The mean follow-up period was 2.2 years. The preoperative spine condition was considered. Accuracy was evaluated using the Gertzbein-Robbins scale (GRS score) and Babu classification (Babu score). Radiological outcomes included adjacent segmental disease (ASD) and mechanical failure. Clinical outcomes were assessed based on the visual analogue scale, Oswestry Disability Index, 36-item Short Form health survey, and clinical ASD rate. 
		                        		
		                        			Results:
		                        			Accuracy was higher in the RS group (p < 0.01) than in other groups. The GRS score was lower in the CG group, whereas the Babu score was lower in the FG group compared with the RS group. No significant differences were observed in radiological and clinical outcomes among the 3 groups. Regression analysis identified preoperative facet degeneration, GRS and Babu scores as significant variables for radiological and clinical ASD. Mechanical failure was influenced by the GRS score and patients’ age. 
		                        		
		                        			Conclusion
		                        			This study showed the superior accuracy of robotic spine surgery compared with conventional techniques. When combined with minimally invasive surgery, robotic surgery is advantageous with reduced ligament and muscle damage associated with traditional open procedures. 
		                        		
		                        		
		                        		
		                        	
3.Clinical Outcomes After Drug-Coated Balloon Treatment in Popliteal Artery Disease: K-POP Registry 12-Month Results
Jong-Il PARK ; Young-Guk KO ; Seung-Jun LEE ; Chul-Min AHN ; Seung-Woon RHA ; Cheol-Woong YU ; Jong Kwan PARK ; Sang-Ho PARK ; Jae-Hwan LEE ; Su-Hong KIM ; Yong-Joon LEE ; Sung-Jin HONG ; Jung-Sun KIM ; Byeong-Keuk KIM ; Myeong-Ki HONG ; Donghoon CHOI
Korean Circulation Journal 2024;54(8):454-465
		                        		
		                        			 Background and Objectives:
		                        			The popliteal artery is generally regarded as a “no-stent zone.”Limited data are available on the outcomes of drug-coated balloons (DCBs) for popliteal artery disease. This study aimed to evaluate the 12-month clinical outcomes among patients who received DCB treatment for atherosclerotic popliteal artery disease. 
		                        		
		                        			Methods:
		                        			This prospective, multicenter registry study enrolled 100 patients from 7 Korean endovascular centers who underwent endovascular therapy using IN.PACT DCB (Medtronic) for symptomatic atherosclerotic popliteal artery disease. The primary endpoint was 12-month clinical primary patency and the secondary endpoint was clinically driven target lesion revascularization (TLR)–free rate. 
		                        		
		                        			Results:
		                        			The mean age of the study cohort was 65.7±10.8 years, and 77% of enrolled patients were men. The mean lesion length was 93.7±53.7 mm, and total occlusions were present in 45% of patients. Technical success was achieved in all patients. Combined atherectomy was performed in 17% and provisional stenting was required in 11%. Out of the enrolled patients, 91 patients completed the 12-month follow-up. Clinical primary patency and TLR-free survival rates at 12 months were 76.0% and 87.2%, respectively. A multivariate Cox regression analysis identified female and longer lesion length as the significant independent predictors of loss of patency. 
		                        		
		                        			Conclusions
		                        			DCB treatment yielded favorable 12-month clinical primary patency and TLRfree survival outcomes in patients with popliteal artery disease. 
		                        		
		                        		
		                        		
		                        	
4.A Propensity Score-Matched Cohort Study Comparing 3 Different Spine Pedicle Screw Fixation Methods: Freehand, Fluoroscopy-Guided, and Robot-Assisted Techniques
Yoon Ha HWANG ; Byeong-Jin HA ; Hyung Cheol KIM ; Byung Ho LEE ; Jeong-Yoon PARK ; Dong-Kyu CHIN ; Seong YI
Neurospine 2024;21(1):83-94
		                        		
		                        			 Objective:
		                        			This study aimed to compare the accuracy of robotic spine surgery and conventional pedicle screw fixation in lumbar degenerative disease. We evaluated clinical and radiological outcomes to demonstrate the noninferiority of robotic surgery. 
		                        		
		                        			Methods:
		                        			This study employed propensity score matching and included 3 groups: robot-assisted mini-open posterior lumbar interbody fusion (PLIF) (robotic surgery, RS), c-arm guided minimally invasive surgery transforaminal lumbar interbody fusion (C-arm guidance, CG), and freehand open PLIF (free of guidance, FG) (54 patients each). The mean follow-up period was 2.2 years. The preoperative spine condition was considered. Accuracy was evaluated using the Gertzbein-Robbins scale (GRS score) and Babu classification (Babu score). Radiological outcomes included adjacent segmental disease (ASD) and mechanical failure. Clinical outcomes were assessed based on the visual analogue scale, Oswestry Disability Index, 36-item Short Form health survey, and clinical ASD rate. 
		                        		
		                        			Results:
		                        			Accuracy was higher in the RS group (p < 0.01) than in other groups. The GRS score was lower in the CG group, whereas the Babu score was lower in the FG group compared with the RS group. No significant differences were observed in radiological and clinical outcomes among the 3 groups. Regression analysis identified preoperative facet degeneration, GRS and Babu scores as significant variables for radiological and clinical ASD. Mechanical failure was influenced by the GRS score and patients’ age. 
		                        		
		                        			Conclusion
		                        			This study showed the superior accuracy of robotic spine surgery compared with conventional techniques. When combined with minimally invasive surgery, robotic surgery is advantageous with reduced ligament and muscle damage associated with traditional open procedures. 
		                        		
		                        		
		                        		
		                        	
5.Clinical Outcomes After Drug-Coated Balloon Treatment in Popliteal Artery Disease: K-POP Registry 12-Month Results
Jong-Il PARK ; Young-Guk KO ; Seung-Jun LEE ; Chul-Min AHN ; Seung-Woon RHA ; Cheol-Woong YU ; Jong Kwan PARK ; Sang-Ho PARK ; Jae-Hwan LEE ; Su-Hong KIM ; Yong-Joon LEE ; Sung-Jin HONG ; Jung-Sun KIM ; Byeong-Keuk KIM ; Myeong-Ki HONG ; Donghoon CHOI
Korean Circulation Journal 2024;54(8):454-465
		                        		
		                        			 Background and Objectives:
		                        			The popliteal artery is generally regarded as a “no-stent zone.”Limited data are available on the outcomes of drug-coated balloons (DCBs) for popliteal artery disease. This study aimed to evaluate the 12-month clinical outcomes among patients who received DCB treatment for atherosclerotic popliteal artery disease. 
		                        		
		                        			Methods:
		                        			This prospective, multicenter registry study enrolled 100 patients from 7 Korean endovascular centers who underwent endovascular therapy using IN.PACT DCB (Medtronic) for symptomatic atherosclerotic popliteal artery disease. The primary endpoint was 12-month clinical primary patency and the secondary endpoint was clinically driven target lesion revascularization (TLR)–free rate. 
		                        		
		                        			Results:
		                        			The mean age of the study cohort was 65.7±10.8 years, and 77% of enrolled patients were men. The mean lesion length was 93.7±53.7 mm, and total occlusions were present in 45% of patients. Technical success was achieved in all patients. Combined atherectomy was performed in 17% and provisional stenting was required in 11%. Out of the enrolled patients, 91 patients completed the 12-month follow-up. Clinical primary patency and TLR-free survival rates at 12 months were 76.0% and 87.2%, respectively. A multivariate Cox regression analysis identified female and longer lesion length as the significant independent predictors of loss of patency. 
		                        		
		                        			Conclusions
		                        			DCB treatment yielded favorable 12-month clinical primary patency and TLRfree survival outcomes in patients with popliteal artery disease. 
		                        		
		                        		
		                        		
		                        	
6.Clinical Outcomes After Drug-Coated Balloon Treatment in Popliteal Artery Disease: K-POP Registry 12-Month Results
Jong-Il PARK ; Young-Guk KO ; Seung-Jun LEE ; Chul-Min AHN ; Seung-Woon RHA ; Cheol-Woong YU ; Jong Kwan PARK ; Sang-Ho PARK ; Jae-Hwan LEE ; Su-Hong KIM ; Yong-Joon LEE ; Sung-Jin HONG ; Jung-Sun KIM ; Byeong-Keuk KIM ; Myeong-Ki HONG ; Donghoon CHOI
Korean Circulation Journal 2024;54(8):454-465
		                        		
		                        			 Background and Objectives:
		                        			The popliteal artery is generally regarded as a “no-stent zone.”Limited data are available on the outcomes of drug-coated balloons (DCBs) for popliteal artery disease. This study aimed to evaluate the 12-month clinical outcomes among patients who received DCB treatment for atherosclerotic popliteal artery disease. 
		                        		
		                        			Methods:
		                        			This prospective, multicenter registry study enrolled 100 patients from 7 Korean endovascular centers who underwent endovascular therapy using IN.PACT DCB (Medtronic) for symptomatic atherosclerotic popliteal artery disease. The primary endpoint was 12-month clinical primary patency and the secondary endpoint was clinically driven target lesion revascularization (TLR)–free rate. 
		                        		
		                        			Results:
		                        			The mean age of the study cohort was 65.7±10.8 years, and 77% of enrolled patients were men. The mean lesion length was 93.7±53.7 mm, and total occlusions were present in 45% of patients. Technical success was achieved in all patients. Combined atherectomy was performed in 17% and provisional stenting was required in 11%. Out of the enrolled patients, 91 patients completed the 12-month follow-up. Clinical primary patency and TLR-free survival rates at 12 months were 76.0% and 87.2%, respectively. A multivariate Cox regression analysis identified female and longer lesion length as the significant independent predictors of loss of patency. 
		                        		
		                        			Conclusions
		                        			DCB treatment yielded favorable 12-month clinical primary patency and TLRfree survival outcomes in patients with popliteal artery disease. 
		                        		
		                        		
		                        		
		                        	
7.A Propensity Score-Matched Cohort Study Comparing 3 Different Spine Pedicle Screw Fixation Methods: Freehand, Fluoroscopy-Guided, and Robot-Assisted Techniques
Yoon Ha HWANG ; Byeong-Jin HA ; Hyung Cheol KIM ; Byung Ho LEE ; Jeong-Yoon PARK ; Dong-Kyu CHIN ; Seong YI
Neurospine 2024;21(1):83-94
		                        		
		                        			 Objective:
		                        			This study aimed to compare the accuracy of robotic spine surgery and conventional pedicle screw fixation in lumbar degenerative disease. We evaluated clinical and radiological outcomes to demonstrate the noninferiority of robotic surgery. 
		                        		
		                        			Methods:
		                        			This study employed propensity score matching and included 3 groups: robot-assisted mini-open posterior lumbar interbody fusion (PLIF) (robotic surgery, RS), c-arm guided minimally invasive surgery transforaminal lumbar interbody fusion (C-arm guidance, CG), and freehand open PLIF (free of guidance, FG) (54 patients each). The mean follow-up period was 2.2 years. The preoperative spine condition was considered. Accuracy was evaluated using the Gertzbein-Robbins scale (GRS score) and Babu classification (Babu score). Radiological outcomes included adjacent segmental disease (ASD) and mechanical failure. Clinical outcomes were assessed based on the visual analogue scale, Oswestry Disability Index, 36-item Short Form health survey, and clinical ASD rate. 
		                        		
		                        			Results:
		                        			Accuracy was higher in the RS group (p < 0.01) than in other groups. The GRS score was lower in the CG group, whereas the Babu score was lower in the FG group compared with the RS group. No significant differences were observed in radiological and clinical outcomes among the 3 groups. Regression analysis identified preoperative facet degeneration, GRS and Babu scores as significant variables for radiological and clinical ASD. Mechanical failure was influenced by the GRS score and patients’ age. 
		                        		
		                        			Conclusion
		                        			This study showed the superior accuracy of robotic spine surgery compared with conventional techniques. When combined with minimally invasive surgery, robotic surgery is advantageous with reduced ligament and muscle damage associated with traditional open procedures. 
		                        		
		                        		
		                        		
		                        	
8.Clinical Outcomes After Drug-Coated Balloon Treatment in Popliteal Artery Disease: K-POP Registry 12-Month Results
Jong-Il PARK ; Young-Guk KO ; Seung-Jun LEE ; Chul-Min AHN ; Seung-Woon RHA ; Cheol-Woong YU ; Jong Kwan PARK ; Sang-Ho PARK ; Jae-Hwan LEE ; Su-Hong KIM ; Yong-Joon LEE ; Sung-Jin HONG ; Jung-Sun KIM ; Byeong-Keuk KIM ; Myeong-Ki HONG ; Donghoon CHOI
Korean Circulation Journal 2024;54(8):454-465
		                        		
		                        			 Background and Objectives:
		                        			The popliteal artery is generally regarded as a “no-stent zone.”Limited data are available on the outcomes of drug-coated balloons (DCBs) for popliteal artery disease. This study aimed to evaluate the 12-month clinical outcomes among patients who received DCB treatment for atherosclerotic popliteal artery disease. 
		                        		
		                        			Methods:
		                        			This prospective, multicenter registry study enrolled 100 patients from 7 Korean endovascular centers who underwent endovascular therapy using IN.PACT DCB (Medtronic) for symptomatic atherosclerotic popliteal artery disease. The primary endpoint was 12-month clinical primary patency and the secondary endpoint was clinically driven target lesion revascularization (TLR)–free rate. 
		                        		
		                        			Results:
		                        			The mean age of the study cohort was 65.7±10.8 years, and 77% of enrolled patients were men. The mean lesion length was 93.7±53.7 mm, and total occlusions were present in 45% of patients. Technical success was achieved in all patients. Combined atherectomy was performed in 17% and provisional stenting was required in 11%. Out of the enrolled patients, 91 patients completed the 12-month follow-up. Clinical primary patency and TLR-free survival rates at 12 months were 76.0% and 87.2%, respectively. A multivariate Cox regression analysis identified female and longer lesion length as the significant independent predictors of loss of patency. 
		                        		
		                        			Conclusions
		                        			DCB treatment yielded favorable 12-month clinical primary patency and TLRfree survival outcomes in patients with popliteal artery disease. 
		                        		
		                        		
		                        		
		                        	
9.A Propensity Score-Matched Cohort Study Comparing 3 Different Spine Pedicle Screw Fixation Methods: Freehand, Fluoroscopy-Guided, and Robot-Assisted Techniques
Yoon Ha HWANG ; Byeong-Jin HA ; Hyung Cheol KIM ; Byung Ho LEE ; Jeong-Yoon PARK ; Dong-Kyu CHIN ; Seong YI
Neurospine 2024;21(1):83-94
		                        		
		                        			 Objective:
		                        			This study aimed to compare the accuracy of robotic spine surgery and conventional pedicle screw fixation in lumbar degenerative disease. We evaluated clinical and radiological outcomes to demonstrate the noninferiority of robotic surgery. 
		                        		
		                        			Methods:
		                        			This study employed propensity score matching and included 3 groups: robot-assisted mini-open posterior lumbar interbody fusion (PLIF) (robotic surgery, RS), c-arm guided minimally invasive surgery transforaminal lumbar interbody fusion (C-arm guidance, CG), and freehand open PLIF (free of guidance, FG) (54 patients each). The mean follow-up period was 2.2 years. The preoperative spine condition was considered. Accuracy was evaluated using the Gertzbein-Robbins scale (GRS score) and Babu classification (Babu score). Radiological outcomes included adjacent segmental disease (ASD) and mechanical failure. Clinical outcomes were assessed based on the visual analogue scale, Oswestry Disability Index, 36-item Short Form health survey, and clinical ASD rate. 
		                        		
		                        			Results:
		                        			Accuracy was higher in the RS group (p < 0.01) than in other groups. The GRS score was lower in the CG group, whereas the Babu score was lower in the FG group compared with the RS group. No significant differences were observed in radiological and clinical outcomes among the 3 groups. Regression analysis identified preoperative facet degeneration, GRS and Babu scores as significant variables for radiological and clinical ASD. Mechanical failure was influenced by the GRS score and patients’ age. 
		                        		
		                        			Conclusion
		                        			This study showed the superior accuracy of robotic spine surgery compared with conventional techniques. When combined with minimally invasive surgery, robotic surgery is advantageous with reduced ligament and muscle damage associated with traditional open procedures. 
		                        		
		                        		
		                        		
		                        	
10.Clinical Values of Whole‑Body Blood Pool Scans and SPECT for Evaluation of Congenital Vascular Malformation
Junik SON ; Chae Moon HONG ; Jaetae LEE ; Ho Yun CHUNG ; Byeong‑Cheol AHN
Nuclear Medicine and Molecular Imaging 2024;58(2):69-80
		                        		
		                        			 Purpose:
		                        			This study examines the diagnostic potential of whole-body blood pool scintigraphy (WBBPS) using technetium-99 m-labeled red blood cells to detect congenital vascular malformations (CVMs). It aims to compare its efficacy with traditional imaging techniques such as magnetic resonance imaging (MRI) and ultrasonography (USG), emphasizing its potential advantages in terms of characterization of lesions and capacity for whole-body assessment. 
		                        		
		                        			Methods:
		                        			The efficacy of WBBPS and single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging in diagnosing CVMs, comparing them with USG and MRI results, was evaluated in this retrospective study. Of the 38 patients, 21 were evaluated using these diagnostic methods, with CVMs classified according to the International Society for the Study of Vascular Anomalies guidelines. Also, this study aimed to elucidate the characteristics between WBBPS, SPECT/CT, USG, or MRI findings and their consistency with the final diagnosis. 
		                        		
		                        			Results:
		                        			A total of 21 participants were included in this study, with an average age of 17.7 years old, with female predominance (57.1%). The most common diagnosis was vascular malformations (VMs) (71.4%), followed by combined vascular malformations (14.3%) and lymphatic malformations (9.5%). WBBPS demonstrated positive results in 95.2% of cases.Distinct imaging patterns for each condition were observed, with WBBPS being crucial in locating lesions. 
		                        		
		                        			Conclusion
		                        			The study findings suggested that WBBPS with SPECT/CT could be helpful in detecting occult VM lesions and ruling out a lymphatic malformation diagnosis. Thus, it can be employed in the evaluation of CVMs. 
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail