1.Effects of clinical application of free anterolateral thigh perforator lobulated flap in repair of electrical burn wounds on head based on the concept of donor site protection.
Peng Fei GUO ; Xu WANG ; Ai Zhou WEI ; Qing Nan MENG ; Jian ZHOU ; Ya GAO ; Zheng Jun CUI
Chinese Journal of Burns 2022;38(1):77-80
Objective: To explore the effects of clinical application of free anterolateral thigh perforator lobulated flap in repair of electrical burn wounds on head based on the concept of donor site protection. Methods: A retrospective observational study was conducted. Eight patients with electrical burns with huge scalp defects and exposed skulls were admitted to the First Affiliated Hospital of Zhengzhou University, from May 2017 to December 2019, who were all males, aged 21-57 (39±13) years, sustaining multiple deep partial thickness to full-thickness electrical burns to 5%-14% total body surface area. Among the scalp burn sites of the patients, 1 case was posterior occipital, 2 cases were parietal occipital, 4 cases were parietal temporal, and 1 case was frontotemporal. After debridement, the defect area was 10 cm×9 cm-16 cm×14 cm. The incision area of the free anterolateral thigh perforator lobulated flap was 22 cm×6 cm-30 cm×9 cm. The artery and vein of flap were anastomosed with superficial temporal artery and vein or facial artery and vein, and the other vein of skin flap was anastomosed with superficial vein of recipient area. The donor site of skin flap was closed by layer interrupted tension-reducing suture. After the operation, the survival of flop, donor site wound healing and complications were observed. The flap appearance, wound healing of donor sites, long-term complications and functional recovery of donor sites were observed on follow-up. Results: After the operation, the flaps of 8 patients survived completely without vascular crisis. The donor sites of flaps in all the patients healed well with no osteofascial compartment syndrome. Seven patients were followed up for 3 to 12 months, and 1 case was lost to follow up. During follow-up, the flaps of the patients' heads were in good appearance but with alopecia. The donor sites showed linear scars, which were well hidden. There were no significant differences in sensory and motor functions between the two sides, and no complications were found such as muscle hernia. Conclusions: Free anterolateral thigh perforator lobulated flap has a good clinical effect in the early repair of electrical burn wounds with huge scalp defect and skull exposure on head, and the donor wounds can be directly closed and sutured, greatly reducing the damage to the donor area.
Adult
;
Burns, Electric/surgery*
;
Humans
;
Male
;
Middle Aged
;
Perforator Flap
;
Reconstructive Surgical Procedures
;
Skin Transplantation
;
Soft Tissue Injuries/surgery*
;
Thigh/surgery*
;
Treatment Outcome
;
Young Adult
2.Clinical effects of free hallux-nail flap combined with the second toe composite tissue flap in the reconstruction of damaged thumb after electrical burns.
Pei Peng XING ; Xin Ling MU ; Cheng De XIA ; Ji Jing SHI ; Ji Dong XUE ; Gao Yuan YANG ; Jian ZHANG ; Hai Ping DI
Chinese Journal of Burns 2022;38(7):677-682
Objective: To explore the clinical effects of free hallux-nail flap combined with the second toe composite tissue flap in the reconstruction of damaged thumb after electrical burns. Methods: A retrospective observational study was conducted. From May 2018 to April 2021, 12 male patients with thumb destructive defects caused by electrical burns who met the inclusion criteria were admitted to Zhengzhou First People's Hospital, aged 27 to 58 years, including 10 cases with degree Ⅲ thumb defect and 2 cases with degree Ⅳ thumb defect after thorough debridement. The thumb was reconstructed with free hallux-nail flap combined with composite tissue flap of the second phalangeal bone, joint, and tendon with skin island. The donor site of hallux-nail flap was covered with artificial dermis in the first stage and performed with continuous vacuum sealing drainage, and covered with medium-thickness skin graft from the groin site in the second stage. The donor site in the second toe was filled and fixed with iliac bone strips. The survival of reconstructed thumb was observed 1 week after the reconstruction surgery, the survival of skin graft in the donor site of hallux-nail flap was observed 2 weeks after skin grafting, and the callus formation of the reconstructed thumb phalanx and the second toe of the donor foot was observed by X-ray 6 weeks after the reconstruction surgery. During the follow-up, the shape of reconstructed thumb was observed and the sensory function was evaluated; the function of reconstructed thumb was evaluated with trial standard for the evaluation of the functions of the upper limbs of the Hand Surgery Society of the Chinese Medical Association; whether the interphalangeal joints of the hallux and the second toe were stiff, the scar hyperplasia of the foot donor site, and whether the walking and standing functions of the donor feet were limited were observed. Results: One week after the reconstruction surgery, all the reconstructed thumbs of the patients survived. Two weeks after skin grafting, the skin grafts in the donor site of hallux-nail flap of 11 patients survived, while the skin graft in the donor site of hallux-nail flap of 1 patient was partially necrotic, which was healed completely after 10 days' dressing change. Six weeks after the reconstruction surgery, callus formation was observed in the reconstructed thumb and the second toe of the donor foot of 10 patients, the Kirschner wires were removed; while callus formation of the reconstructed thumb was poor in 2 patients, and the Kirschner wires were removed after 2 weeks of delay. During the follow-up of 6 to 24 months, the shape of reconstructed thumb was similar to that of the healthy thumb, the discrimination distance between the two points of the reconstructed thumb was 7 to 11 mm, and the functional evaluation results were excellent in 4 cases, good in 6 cases, and fair in 2 cases. The interphalangeal joints of the hallux and the second toe of the donor foot were stiff, mild scar hyperplasia was left in the donor site of foot, and the standing and walking functions of the donor foot were not significantly limited. Conclusions: The application of free hallux-nail flap combined with the second toe composite tissue flap in the reconstruction of damaged thumb after electrical burns adopts the concept of reconstruction instead of repair to close the wound. It can restore the shape and function of the damaged thumb without causing great damage to the donor foot.
Burns, Electric/surgery*
;
Cicatrix/surgery*
;
Free Tissue Flaps
;
Hallux/surgery*
;
Humans
;
Hyperplasia
;
Male
;
Reconstructive Surgical Procedures/methods*
;
Skin Transplantation/methods*
;
Thumb/surgery*
;
Toes/surgery*
;
Treatment Outcome
3.Free Flow-through Anterolateral Thigh Flaps for Wrist High-tension Electrical Burns: A Retrospective Case Series.
Cheng WANG ; Yu Ming SHEN ; Feng Jun QIN ; Xiao Hua HU
Biomedical and Environmental Sciences 2020;33(7):510-517
Objective:
The objective of this report was to demonstrate the clinical application of free flow-through anterolateral thigh flaps for the treatment of high-tension electrical wrist burns.
Methods:
We collected the data of 8 patients with high-tension electrical wrist burns admitted to Beijing Jishuitan Hospital from January 2014 to December 2018. The clinical and pathological data were extracted from electronic hospital medical records. We obtained follow-up information through clinic visits.
Results:
The injury sites for all 8 patients were the wrists, specifically 5 right and 3 left wrists, all of which were on the flexor side. Five patients had ulnar artery embolism necrosis and patency, with injury to the radial artery. Two patients had ulnar and radial arterial embolization and necrosis. The last patient had ulnar arterial embolization and necrosis with a normal radial artery. After debridement, the wound area ranged from 12 cm × 9 cm to 25 cm × 16 cm. The diagnoses for the eight patients were type II to type III high-tension electrical wrist burns. Free flow-through anterolateral thigh flaps (combined with great saphenous vein transplantation if necessary) were used to repair the wounds. The prognosis for all patients was good after six months to one year of follow-up.
Conclusion
Treating wrist types II and III high-tension electrical burns is still challenging in clinical practice. The use of free flow-through anterolateral thigh flaps (combined with great saphenous vein transplantation if necessary) to repair the wound and to restore the blood supply for the hand at the same time is a good choice for treating severe wrist electrical burns.
Adult
;
Beijing
;
Burns, Electric
;
surgery
;
Humans
;
Male
;
Retrospective Studies
;
Surgical Flaps
;
statistics & numerical data
;
Thigh
;
Wound Healing
;
Wrist Injuries
;
surgery
;
Young Adult
4.Clinical application of modified skin soft tissue expansion in early repair of devastating wound on the head due to electrical burn.
Jin LEI ; Chunsheng HOU ; Peng DUAN ; Zhengming HAO ; Yanbin ZHAI ; Yanbin MENG ; Email: M64225@163.COM.
Chinese Journal of Burns 2015;31(6):406-409
OBJECTIVETo observe the clinical effect of modified skin soft tissue expansion in repair of devastating wound on the head due to electrical burn in the early stage.
METHODSTwenty-one patients with partial scalp soft tissue defect accompanying skull exposure and necrosis in different degree due to high-voltage electrical burn were hospitalized from April 2009 to October 2014, with wound area ranging from 7 cm × 5 cm to 15 cm × 13 cm. The wounds were debrided as early as possible, and necrotic skulls were kept in situ and covered with porcine ADM and silver-containing dressing. Bacterial culture of exudate from the residual soft tissue was carried out 3 days after hospitalization. Pertinent antibiotics were applied topically to control infection, and autologous split-thickness skin grafts were transplanted. Two to three weeks after injury when the skin grafts survived, modified skin soft tissue expansion was carried out. The crossbow-form incision was made on the normal scalp 2 cm away from the edge of transplanted skin; a capsule cavity was formed by ladder-like dissection. An expander was inserted with the injection port laying outside. The expander was stretched by inflation and deflation. The incisions were sutured layer by layer. The time of continuing negative pressure drainage in the interval of expansion was extended. Volume of water reaching 2 to 3 times of the capacity of expander was injected for excessive expanding. The expanded skin flap was rotated to repair the wound after expansion was ended.
RESULTSWithin 1 week after debridement, 4 kinds of bacteria were detected in the bacterial culture of wound exudate, including 4 cases of Staphylococcus aureus, 5 cases of Staphylococcus epidermidis, 5 cases of Pseudomonas aeruginosa, and 3 cases of Acinetobacter baumannii. A total of 26 expanders were imbedded. No infection or incision dehiscence in the expanding area or cracking and leakage of expander was observed during expanding period. Two to three months after injury, expanded skin flap transplantation was completed, and the wound was repaired. Raw wounds were seen in 4 expanded skin flaps after transfer, and they healed after dressing change. Punctiform ulceration at the seams of 2 flaps was observed one month after the operation, which healed after removing few pieces of sequestra by themselves. The other expanded skin flaps survived well. During the postoperative follow-up for 3 to 12 months, satisfactory appearance and hair growth was observed in the operation area.
CONCLUSIONSRepair of the devastating wound on the head due to electrical burn with modified skin soft tissue expansion could achieve the result of early wound covering and cosmetic repair without alopecia in one time.
Animals ; Bandages ; Burns, Electric ; surgery ; Craniocerebral Trauma ; surgery ; Debridement ; Female ; Head ; Humans ; Male ; Middle Aged ; Necrosis ; Postoperative Complications ; Reconstructive Surgical Procedures ; methods ; Skin Transplantation ; Skull ; Soft Tissue Injuries ; surgery ; Staphylococcus aureus ; Surgical Flaps ; Swine ; Tissue Expansion ; Treatment Outcome ; Wound Healing
5.The middle-forearm flap based on perforator of ulnar artery for electrical burn wound on the wrist .
Chu GUOPING ; Yang MINLIE ; Yu SHUN ; Qin HONGBO ; Zhao QINGGUO ; Su QINGHE ; Lyu GUOZHONG
Chinese Journal of Plastic Surgery 2014;30(5):346-348
OBJECTIVETo dicuss the application and therapeutic effect of middle-forearm flap based on perforator of ulnar artery for electrical burn wound on the wrist.
METHODSFrom Oct. 2009 to Oct. 2012, 10 cases of electrical burn wounds on the wrist were treated. A line from radialis medial epicondyle of humerus to the interior radialis pisiform bone was connected as flap axis. At the midpoint of the line, Doppler flow imaging meter was used to detect the emerging point of perforator vessel. The flap was designed and harvested. The flap was transferred reversely, with superficial vein retaining which was anastomosed with vein at recipient sites in 3 cases. The wounds in the donor sites were closed directly in 2 cases, and with skin graft in 8 cases.
RESULTSAll the 10 flaps survived completely. 7 cases without vein anastomosis underwent obvious flap edema during 2-4 days postoperatively, which resovled 1 week later. Sub-flap tissue necrosis and infection happened in 2 cases, which healed after dressing and drainage. Patients were followed up for 3-36 months with satisfactory results.
CONCLUSIONSThe middle-forearm flap based on perforator of ulnar artery has a stable and reliable blood supply. It offers a new choice for the electric burn wound on the wrist, especially at the ulnar side.
Burns, Electric ; surgery ; Forearm ; Humans ; Reconstructive Surgical Procedures ; Skin Transplantation ; Surgical Flaps ; blood supply ; transplantation ; Ulnar Artery ; Wrist Injuries ; surgery
6.Opportune time and method of reconstruction of penile defects caused by devastating electrical burn.
Yi LIU ; Bin XIAO ; Ping LIU ; Jiang JIANG ; Mei SONG ; Liming CHEN ; Chengxin XU ; Xiaochen SUN ; Xianying ZHANG ; Cheng ZHANG ; Xusheng ZHANG
Chinese Journal of Burns 2014;30(5):394-399
OBJECTIVETo explore the timing and suitable method of reconstructing penile defects caused by devastating electrical burn.
METHODSThirteen patients with penile defects after devastating electrical burn, hospitalized from September 1998 to August 2013, were included in this study. After the necrotic tissues in the wounds were removed by dressing changes, a local or a hinge-like flap constructed from scrotum or abdominal wall, a prelaminated hinge-like flap from forearm, or a free forearm flap was selected, according to the injury degree of the penis, for the repair of the defect or reconstruction of penis respectively.
RESULTSThe flaps survived and the wounds healed well in 2 patients repaired with local flaps from scrotum or abdominal wall. Urethritis occurred in 2 patients 6 to 9 months after the transplantation of hinge-like flaps from scrotum, and they were cured by appropriate drugs. Functions of urination and erection of penis were recovered in these 4 patients. All flaps survived in the 5 patients repaired with hinge-like flaps from abdominal wall or prelaminated flaps from forearm. The wounds in 2 patients healed; wound dehiscence occurred in the other 3 patients in different degrees, and they healed after suturing for 2 or 3 times. The function of erection of penis recovered in these 5 patients, but with discontinuity of urinary stream during urination. Among them, 3 married patients enjoyed satisfactory sexual life. All free forearm flaps survived and the wounds healed well in 4 patients. Urinary fistula occurred in 1 patient, and it was repaired by a secondary operation. These 4 patients experienced normal urination function, but only 2 patients in whom corpus spongiosum partially remained retained the function of erection of penis to certain degree. All these 4 patients could not perform normal sexual intercourse. All patients were followed up for 6 to 13 months after surgery. Under ordinary state, the length of penis was 5.9-9.3 cm, and the circumference of penis was 8.4-10.0 cm. Wound scar was not obvious in all cases. Nine patients reported a restricted erection.
CONCLUSIONSPenile defect caused by devastating electrical burn should be repaired with a suitable flap after necrotic tissues are removed with dressing change. To repair affected penis with necrosis of a small part of cavernous body and/or corpus spongiosum, or combined with urethra defects, local flaps from scrotum or abdominal wall or hinge-like flap from scrotum should be employed. To repair those with necrosis of a large part or the whole of corpus spongiosum combined with urethra defects, hinge-like skin flaps from abdominal wall or prelaminated flaps from forearm should be employed. In patients with necrosis of a large part of cavernous body and corpus spongiosum combined with urethra defect, or total loss of penis, free forearm flaps should be employed to reconstruct penis.
Burns, Electric ; surgery ; Free Tissue Flaps ; Humans ; Male ; Necrosis ; Penis ; injuries ; surgery ; Postoperative Complications ; Reconstructive Surgical Procedures ; methods ; Scrotum ; Skin Transplantation ; Surgical Flaps ; Time Factors ; Treatment Outcome ; Wound Healing
7.Simple flaps for reconstruction of pediatric scalp defects after electrical burn.
Mohamed MAKBOUL ; Mohamed ABDEL-RAHIM
Chinese Journal of Traumatology 2013;16(4):204-206
OBJECTIVETo analyze the management of high-voltage electrical burn injury of the scalp in our hospital.
METHODSThis study involved 10 patients who suffered from high-voltage electrical burn injury of the scalp. Scalp reconstruction was done by different modalities according to the size and location of the defect.
RESULTSComplete flap viability was achieved in all the cases. We had one case of gapped wound which was managed only by dressing. Widening of the scar was found in 2 cases.
CONCLUSIONRotation, advancement and transposition scalp flaps are used for reconstructing scalp defects caused by electrical burn. The choice of ideal flaps for reconstruction depends upon the size and site of scalp defect.
Adolescent ; Burns, Electric ; surgery ; Child ; Female ; Humans ; Male ; Reconstructive Surgical Procedures ; methods ; Scalp ; injuries ; surgery ; Surgical Flaps ; Treatment Outcome
8.Treatment of thoracic and abdominal cavity perforation complicated by Henoch-Schonlein purpura nephritis in a patient with high-voltage electric burn.
Wei ZHANG ; Wei-guo XIE ; Wei-xiong MIN ; De-yun WANG ; Jia ZHANG ; Shi-yong WAN
Chinese Journal of Burns 2013;29(5):454-458
A 55-year-old male patient suffered from severe high-voltage electric burn with an area of 20%TBSA full-thickness injury. The injury involved the distal end of left upper limb, right trunk, and whole abdominal wall. Fracture of the 7th-10th ribs was found in the right side of chest, with perforation of abdominal cavity, and bilateral pleural effusion was found. Part of the small intestine was necrotic and exposed. At the early stage, xeno-acellular dermal matrix was grafted after debridement of abdominal wound; peritoneal lavage was performed; negative pressure drainage was performed in orificium fistula of intestine for promoting the adhesion between perforated intestine and abdominal scar. Two orificium fistulas formed after closure of abdominal granulation wound by autologous skin grafting. Eschar of chest wall and denatured ribs were retained. The risk of infection of thoracic cavity was decreased by promoting the adhesion between lung tissue and chest wall. During the treatment, the patient was diagnosed with Henoch-Schonlein purpura nephritis by renal biopsy, with the symptoms of purpura in the lower limbs, heavy proteinuria, severe hypoalbuminemia, edema, etc. After control of kidney damage by immunosuppressive treatment instead of glucocorticoid, alleviation of the levels of proteinuria and blood albumin, free latissimus dorsi myocutaneous flap was excised to repair chest wall, and free skin graft was excised to repair intestinal fistula. After all the wounds were successfully covered, the patient was treated with glucocorticoid combined with immunosuppressants for more than 1 year. The patient was followed up for 3 years, and his renal function was completely recovered with satisfactory clinical outcome.
Abdominal Cavity
;
Abdominal Injuries
;
complications
;
surgery
;
Burns, Electric
;
complications
;
surgery
;
Humans
;
Male
;
Middle Aged
;
Nephritis
;
complications
;
surgery
;
Purpura, Schoenlein-Henoch
;
complications
;
surgery
;
Thoracic Cavity
;
Thoracic Injuries
;
complications
;
surgery
9.Repair of wound on hand or foot due to electrical burn using free lateral upper arm perforator flap.
Pi-hong ZHANG ; Ming-hua ZHANG ; Ting-hong XIE ; Jie ZHOU ; Li-cheng REN ; Peng-fei LIANG ; Ji-zhang ZENG ; Xiao-yuan HUANG
Chinese Journal of Burns 2013;29(5):424-426
OBJECTIVETo observe the effect of free lateral upper arm perforator flap in repairing wound on hand or foot due to electrical burn.
METHODSSix patients with full-thickness wounds on hand or foot resulting from electrical burn were hospitalized from June 2010 to June 2013. The wounds ranged from 6.0 cm ×4.0 cm to 8.5 cm×7.5 cm in area. Free lateral upper arm perforator flaps were used to repair these defects, with flap area ranging from 9 cm ×4 cm to 12 cm × 9 cm. The donor sites in five cases were closed by suturing; the other one donor site was closed by transplantation of full-thickness skin from abdomen.
RESULTSOne flap used to repair the wound in middle finger failed due to failure of venous return, and it was repaired with full-thickness skin harvested from abdomen after dressing change. The other five flaps survived resulting in good elasticity and matched appearance of the recipient area without obvious bulkiness. Patients were followed up for 6 to 24 months. The function of the injured hands or feet recovered well, and the results of function evaluation of five hands were excellent in 2 cases, good in 2 cases, and poor in 1 case. Little scar formation with no contraction or function impairment was observed on donor site, and the result was satisfactory.
CONCLUSIONSFree lateral upper arm perforator flap, with long vessel and less adipose tissue, is suitable for repairing small but deep wound on hand or foot due to electrical burn.
Adult ; Aged ; Arm ; surgery ; Burns, Electric ; surgery ; Foot Injuries ; surgery ; Hand Injuries ; surgery ; Humans ; Male ; Middle Aged ; Perforator Flap ; Skin Transplantation ; methods ; Young Adult
10.Repair of deep wound on the head due to high-voltage electrical burn.
Xi-sheng XU ; Kai CHEN ; Bo-tong LI ; Hai-yang ZHOU ; Zheng-zheng MA ; Yong-sheng ZHOU ; Cai-sheng OU ; Yong CHENG ; Yun HUANG ; Yong-cai HU ; Yi ZHANG ; Yong-fei WANG
Chinese Journal of Burns 2012;28(6):415-418
OBJECTIVETo explore the methods for repairing deep wound on the head due to high-voltage electrical burn (HEB).
METHODSTwenty-six patients with deep wounds on the head due to HEB were hospitalized from June 2002 to May 2012. They were all injured by high-voltage (voltage ranged from 380 V to 300 kV) electric current, involving head and several other parts over the body. The total burn area ranged from 1% to 75% TBSA, and the depth ranged from deep partial-thickness to full-thickness (including muscle or even bone). Scalp defect area ranged from 3 cm×2 cm to 20 cm×18 cm, and the maximum size of skull exposure was 12 cm×9 cm and the maximum size of skull defect was 7 cm×6 cm. The wounds of 26 patients were repaired with 7 local advance flaps, 4 bilateral rotation flaps, 18 local rotation flaps combined with thin split-thickness skin grafts in donor site, and 3 free anterolateral thigh flaps with vascular anastomosis. In four of the 26 patients, expander was used in the early stage after burn and 5 after wound healing (with thin split-thickness grafts).
RESULTSAll flaps and skin grafts survived, except for one flap which was complicated by wound infection, and it was healed after dressing and secondary suturing. The implanted expander expanded smoothly. Patients were followed up for 15 days to three years after surgery. Satisfactory results were obtained, and wounds of 15 patients were repaired completely.
CONCLUSIONSDeep wound on the head due to HEB should be repaired with suitable flap combined with skin graft in donor site, and implantation of expander according to the injury area and condition of patient.
Adolescent ; Adult ; Burns, Electric ; surgery ; Child ; Craniocerebral Trauma ; surgery ; Female ; Humans ; Male ; Middle Aged ; Reconstructive Surgical Procedures ; methods ; Skin Transplantation ; Surgical Flaps ; Young Adult

Result Analysis
Print
Save
E-mail