1.Retrospective analysis of BI-RADS 4 and 5 lesions additionally detected by breast MRI.
Lei JIANG ; Jia Yin GAO ; Zhu Jin XU ; Shu Rong HE ; Bin HUA
Chinese Journal of Surgery 2023;61(2):100-106
Objectives: To establish a newly-designed scoring system for breast imaging-reporting and data system (BI-RADS) 4 and 5 breast lesions only visible on MRI, and to examine their clinical pathway of biopsy. Methods: The BI-RADS 4 and 5 breast lesions only visible on MRI but not suspected on mammograms or ultrasound between June 2007 and December 2021 at Beijing Hospital were evaluated retrospectively. A total of 209 lesions from 184 patients were finally included. All patients were female, aged (50±11) years (range: 27 to 76 years). All lesions were confirmed by pathology and divided into malignancy and non-malignancy. The lesions were divided into mass and non-mass type using BI-RADS. The receiver operator characteristic (ROC) curve was used to evaluate the diagnostic performance of the new scoring system. Four types of pathology-obtaining pathway were used: biopsy guided by second-look ultrasound, local excision guided by lesion position information on MRI, intraductal lesion excision guided by methylene blue stain and mastectomy. The data between mass and non-mass lesions were compared by Mann-Whitney U test, χ2 test or Fisher exact test,respectively. Results: There were 124 malignant and 85 non-malignant lesions, while 100 mass and 109 non-mass lessions. The sizes between mass and non-mass lesions showed significant difference(M(IQR)) (7.0 (3.0) mm vs. 25.0 (25.0) mm, U=568.000, P<0.01) and their BI-RADS diagnostic accuracy had no significant difference (53.0% (53/100) vs. 65.1% (71/109), χ2=3.184, P=0.074). The areas under ROC curve of the new scoring system for evaluating mass and non-mass were 0.841 and 0.802, respectively. When taking Score 3 as threshold, it can potentially avoid 14.0% (14/100) and 4.6% (5/109) of biopsies in mass and non-mass, respectively. As to pathway of obtaining pathology, second-look ultrasound succeeded more easily in mass than non-mass (41.0% (41/100) vs.26.6% (29/109), χ2=4.851, P=0.028). More MRI-guided local excisions were performed in non-mass than mass (52.3% (57/109) vs. 34.0% (34/100), χ2=7.100, P=0.008). Conclusions: For suspicious breast lesions detected by MRI but not suspected on X-ray or ultrasound, the new scoring system can further increase diagnostic accuracy. The second-look ultrasound plays an important role for obtaining pathology, especially for mass-type lesion.
Humans
;
Female
;
Male
;
Retrospective Studies
;
Breast Neoplasms/diagnostic imaging*
;
Mastectomy
;
Radiography
;
Magnetic Resonance Imaging
2.Comparison of Digital and Screen-Film Mammography for Breast-Cancer Screening: A Systematic Review and Meta-Analysis
Soo Yeon SONG ; Boyoung PARK ; Seri HONG ; Min Jung KIM ; Eun Hye LEE ; Jae Kwan JUN
Journal of Breast Cancer 2019;22(2):311-325
PURPOSE: Digital mammography (DM) has replaced screen-film mammography (SFM). However, findings of comparisons between the performance indicators of DM and SFM for breast-cancer screening have been inconsistent. Moreover, the summarized results from studies comparing the performance of screening mammography according to device type vary over time. Therefore, this study aimed to compare the performance of DM and SFM using recently published data. METHODS: The MEDLINE, Embase, and Cochrane Library databases were searched for paired studies, cohorts, and randomized controlled trials published through 2018 that compared the performance of DM and SFM. All studies comparing the diagnostic accuracy of DM and SFM in asymptomatic, average-risk women aged 40 years and older were included. Two reviewers independently assessed the study quality and extracted the data. RESULTS: Thirteen studies were included in the meta-analysis. The pooled sensitivity (DM, 0.76 [95% confidence interval {CI}, 0.70–0.81]; SFM, 0.76 [95% CI, 0.70–0.81]), specificity (DM, 0.96 [95% CI, 0.94–0.97]; SFM, 0.97 [95% CI, 0.94–0.98]), and area under the receiver-operating characteristic curve (DM, 0.94 [95% CI, 0.92–0.96]; SFM, 0.92 [95% CI, 0.89–0.94]) were similar for both DM and SFM. The pooled screening performance indicators reinforced superior accuracy of full-field DM, which is a more advanced type of mammography, than SFM. The advantage of DM appeared greater among women aged 50 years or older. There was high heterogeneity among studies in the pooled sensitivity, specificity, and overall diagnostic accuracy estimates. Stratifying by study design (prospective or retrospective) and removing studies with a 2-year or greater follow-up period resulted in homogeneous overall diagnostic accuracy estimates. CONCLUSION: The breast-cancer screening performance of DM is similar to that of SFM. The diagnostic performance of DM depends on the study design, and, in terms of performance, full-field DM is superior to SFM, unlike computed radiography systems.
Breast Neoplasms
;
Cohort Studies
;
Early Detection of Cancer
;
Female
;
Follow-Up Studies
;
Humans
;
Mammography
;
Mass Screening
;
Population Characteristics
;
Radiography
;
Sensitivity and Specificity
3.Effect of Different Types of Mammography Equipment on Screening Outcomes: A Report by the Alliance for Breast Cancer Screening in Korea
Bo Hwa CHOI ; Eun Hye LEE ; Jae Kwan JUN ; Keum Won KIM ; Young Mi PARK ; Hye Won KIM ; You Me KIM ; Dong Rock SHIN ; Hyo Soon LIM ; Jeong Seon PARK ; Hye Jung KIM ;
Korean Journal of Radiology 2019;20(12):1638-1645
OBJECTIVE: To investigate the effects of different types of mammography equipment on screening outcomes by comparing the performance of film-screen mammography (FSM), computed radiography mammography (CRM), and digital mammography (DM).MATERIALS AND METHODS: We retrospectively enrolled 128756 sets of mammograms from 10 hospitals participating in the Alliance for Breast Cancer Screening in Korea between 2005 and 2010. We compared the diagnostic accuracy of the types of mammography equipment by analyzing the area under the receiver operating characteristic curve (AUC) with a 95% confidence interval (CI); performance indicators, including recall rate, cancer detection rate (CDR), positive predictive value₁ (PPV₁), sensitivity, specificity, and interval cancer rate (ICR); and the types of breast cancer pathology.RESULTS: The AUCs were 0.898 (95% CI, 0.878–0.919) in DM, 0.860 (0.815–0.905) in FSM, and 0.866 (0.828–0.903) in CRM (p = 0.150). DM showed better performance than FSM and CRM in terms of the recall rate (14.8 vs. 24.8 and 19.8%), CDR (3.4 vs. 2.2 and 2.1 per 1000 examinations), PPV₁ (2.3 vs. 0.9 and 1.1%), and specificity (85.5 vs. 75.3 and 80.3%) (p < 0.001) but not in terms of sensitivity (86.3 vs. 87.4 and 86.3%) and ICR (0.6 vs. 0.4 and 0.4). The proportions of carcinoma in situ (CIS) were 27.5%, 13.6%, and 11.8% for DM, CRM, and FSM, respectively (p = 0.003).CONCLUSION: In comparison to FSM and CRM, DM showed better performance in terms of the recall rate, CDR, PPV₁, and specificity, although the AUCs were similar, and more CISs were detected using DM. The application of DM may help to improve the quality of mammography screenings. However, the overdiagnosis issue of CIS using DM should be evaluated.
Area Under Curve
;
Breast Neoplasms
;
Breast
;
Carcinoma in Situ
;
Korea
;
Mammography
;
Mass Screening
;
Medical Overuse
;
Pathology
;
Radiography
;
Retrospective Studies
;
ROC Curve
;
Sensitivity and Specificity
4.Features of Undiagnosed Breast Cancers at Screening Breast MR Imaging and Potential Utility of Computer-Aided Evaluation.
Mirinae SEO ; Nariya CHO ; Min Sun BAE ; Hye Ryoung KOO ; Won Hwa KIM ; Su Hyun LEE ; Ajung CHU
Korean Journal of Radiology 2016;17(1):59-68
OBJECTIVE: To retrospectively evaluate the features of undiagnosed breast cancers on prior screening breast magnetic resonance (MR) images in patients who were subsequently diagnosed with breast cancer, as well as the potential utility of MR-computer-aided evaluation (CAE). MATERIALS AND METHODS: Between March 2004 and May 2013, of the 72 consecutive pairs of prior negative MR images and subsequent MR images with diagnosed cancers (median interval, 32.8 months; range, 5.4-104.6 months), 36 (50%) had visible findings (mean size, 1.0 cm; range, 0.3-5.2 cm). The visible findings were divided into either actionable or underthreshold groups by the blinded review by 5 radiologists. MR imaging features, reasons for missed cancer, and MR-CAE features according to actionability were evaluated. RESULTS: Of the 36 visible findings on prior MR images, 33.3% (12 of 36) of the lesions were determined to be actionable and 66.7% (24 of 36) were underthreshold; 85.7% (6 of 7) of masses and 31.6% (6 of 19) of non-mass enhancements were classified as actionable lesions. Mimicking physiologic enhancements (27.8%, 10 of 36) and small lesion size (27.8%, 10 of 36) were the most common reasons for missed cancer. Actionable findings tended to show more washout or plateau kinetic patterns on MR-CAE than underthreshold findings, as the 100% of actionable findings and 46.7% of underthreshold findings showed washout or plateau (p = 0.008). CONCLUSION: MR-CAE has the potential for reducing the number of undiagnosed breast cancers on screening breast MR images, the majority of which are caused by mimicking physiologic enhancements or small lesion size.
Adult
;
Aged
;
Breast/*pathology
;
Breast Neoplasms/*diagnosis/pathology/radiography
;
Diagnosis, Computer-Assisted/*methods
;
False Negative Reactions
;
Female
;
Humans
;
Magnetic Resonance Imaging/*methods
;
Mammography/*methods
;
Middle Aged
;
Retrospective Studies
5.Radiation Pneumonitis in Association with Internal Mammary Node Irradiation in Breast Cancer Patients: An Ancillary Result from the KROG 08-06 Study.
Jinhyun CHOI ; Yong Bae KIM ; Kyung Hwan SHIN ; Sung Ja AHN ; Hyung Sik LEE ; Won PARK ; Su Ssan KIM ; Jin Hee KIM ; Kyu Chan LEE ; Dong Won KIM ; Hyun Suk SUH ; Kyung Ran PARK ; Hyun Soo SHIN ; Chang Ok SUH
Journal of Breast Cancer 2016;19(3):275-282
PURPOSE: The aim of this study is to present the incidence of radiation pneumonitis (RP) reported within 6 months after treatment for breast cancer with or without internal mammary node irradiation (IMNI). METHODS: In the Korean Radiation Oncology Group (KROG) 08-06 phase III randomized trial, patients who were node-positive after surgery were randomly assigned to receive radiotherapy either with or without IMNI. A total of 747 patients were enrolled, and three-dimensional treatment planning with computed tomography simulation was performed for all patients. Of the 747 patients, 722 underwent chest X-rays before and within 6 months after radiotherapy. These 722 patients underwent evaluation, and RP was diagnosed on the basis of chest radiography findings and clinical symptoms. The relationship between the incidence of RP and clinical/dosimetric parameters was analyzed. RESULTS: RP developed in 35 patients (4.8%), including grade 1 RP in 26 patients (3.6%), grade 2 RP in nine patients (1.2%); there was no incidence of grade 3 or higher RP. Grade 2 RP cases were observed in only the IMNI group. The risk of developing RP was influenced by IMNI treatment; pneumonitis occurred in 6.5% of patients (n=23/356) who underwent IMNI and in 3.3% of patients (n=12/366) who did not (p=0.047). The differences in lung dosimetric parameters (mean lung dose, V10–40) were statistically significant between the two groups. CONCLUSION: IMNI treatment resulted in increased radiation exposure to the lung and a higher rate of RP, but the incidence and severity of RP was minimal and acceptable. This minor impact on morbidity should be balanced with the impact on survival outcome in future analyses.
Breast Neoplasms*
;
Breast*
;
Humans
;
Incidence
;
Lung
;
Lymphatic Irradiation
;
Pneumonia
;
Radiation Exposure
;
Radiation Oncology
;
Radiation Pneumonitis*
;
Radiography
;
Radiotherapy
;
Thorax
6.Characterization of Breast Lesions: Comparison of Digital Breast Tomosynthesis and Ultrasonography.
Sun Ah KIM ; Jung Min CHANG ; Nariya CHO ; Ann YI ; Woo Kyung MOON
Korean Journal of Radiology 2015;16(2):229-238
OBJECTIVE: To compare the diagnostic performance of digital breast tomosynthesis (DBT) and conventional breast ultrasound (US) to characterize breast lesions as benign or malignant. MATERIALS AND METHODS: A total of 332 women, presenting for screening examinations or for breast biopsy between March and June 2012 were recruited to undergo digital mammography (DM), DBT, and breast US examination. Among them, 113 patients with 119 breast lesions depicted on DM were finally included. Three blinded radiologists performed an enriched reader study and reviewed the DBT and US images. Each reader analyzed the lesions in random order, assigned Breast Imaging Reporting and Data System (BI-RADS) descriptors, rated the images for the likelihood of malignancy (%) and made a BI-RADS final assessment. Diagnostic accuracy, as assessed by the area under the receiver operating characteristic curve, sensitivity, and specificity of DBT and US were compared. RESULTS: Among the 119 breast lesions depicted on DM, 75 were malignant and the remaining 44 were benign. The average diagnostic performance for characterizing breast lesions as benign or malignant in terms of area under the curve was 0.899 for DBT and 0.914 for US (p = 0.394). Mean sensitivity (97.3% vs. 98.7%, p = 0.508) and specificity (44.7% vs. 39.4%, p = 0.360) were also not significantly different. CONCLUSION: Digital breast tomosynthesis may provide similar reader lesion characterization performance to that of US for breast lesions depicted on DM.
Adult
;
Aged
;
Biopsy
;
Breast/*pathology
;
Breast Neoplasms/*diagnosis/radiography/ultrasonography
;
Female
;
Humans
;
Mammography/*methods
;
Middle Aged
;
ROC Curve
;
Radiographic Image Enhancement/*methods
;
Retrospective Studies
;
Sensitivity and Specificity
;
Ultrasonography, Mammary/*methods
7.Imaging Surveillance of Patients with Breast Cancer after Primary Treatment: Current Recommendations.
Jung Hyun YOON ; Min Jung KIM ; Eun Kyung KIM ; Hee Jung MOON
Korean Journal of Radiology 2015;16(2):219-228
Women who have been treated for breast cancer are at risk for second breast cancers, such as ipsilateral recurrence or contralateral metachronous breast cancer. As the number of breast cancer survivors increases, interest in patient management and surveillance after treatment has also increased. However, post-treatment surveillance programs for patients with breast cancer have not been firmly established. In this review, we focus on the imaging modalities that have been used in post-treatment surveillance for patients with breast cancer, such as mammography, ultrasonography, magnetic resonance imaging, and positron emission tomography, the effectiveness of each modality for detecting recurrence, and how they can be applied to manage patients.
Breast Neoplasms/*radiography/therapy/*ultrasonography
;
Female
;
Fluorodeoxyglucose F18/diagnostic use
;
Humans
;
Magnetic Resonance Imaging/methods
;
Mammography/*methods
;
Neoplasm Metastasis/*diagnosis
;
Neoplasm Recurrence, Local/*diagnosis
;
Positron-Emission Tomography/methods
;
Sensitivity and Specificity
;
Ultrasonography, Mammary
8.Screening Ultrasound in Women with Negative Mammography: Outcome Analysis.
Ji Young HWANG ; Boo Kyung HAN ; Eun Young KO ; Jung Hee SHIN ; Soo Yeon HAHN ; Mee Young NAM
Yonsei Medical Journal 2015;56(5):1352-1358
PURPOSE: To show the results of an audit of screening breast ultrasound (US) in women with negative mammography in a single institution and to analyze US-detected cancers within a year and interval cancers. MATERIALS AND METHODS: During the year of 2006, 1974 women with negative mammography were screened with US in our screening center, and 1727 among them had pathologic results or any follow up breast examinations more than a year. We analyzed the distribution of Breast Imaging Reporting and Data System (BI-RADS) category and the performance outcome through follow up. RESULTS: Among 1727 women (age, 30-76 years, median 49.5 years), 1349 women (78.1%) showed dense breasts on mammography, 762 (44.1%) had previous breast US, and 25 women (1.4%) had a personal history of breast cancers. Test negatives were 94.2% (1.627/1727) [BI-RADS category 1 in 885 (51.2%), 2 in 742 (43.0%)]. The recall rate (=BI-RADS category 3, 4, 5) was 5.8%. Eight cancers were additionally detected with US (yield, 4.6 per 1000). The sensitivity, specificity, and positive predictive value (PPV1, PPV2) were 88.9%, 94.6%, 8.0%, and 28.0%, respectively. Eight of nine true positive cancers were stage I or in-situ cancers. One interval cancer was stage I cancer from BI-RADS category 2. CONCLUSION: Screening US detected 4.6 additional cancers among 1000. The recall rate was 5.8%, which is in lower bound of acceptable range of mammography (5-12%), according to American College of Radiology standard.
Adult
;
Aged
;
Breast/pathology
;
Breast Neoplasms/*diagnosis/*radiography/*ultrasonography
;
Female
;
Humans
;
Mammography/*methods
;
Mass Screening/*methods
;
Middle Aged
;
Sensitivity and Specificity
;
Ultrasonography/methods
;
*Ultrasonography, Mammary
9.Distant subcutaneous recurrence of a parathyroid carcinoma: abnormal uptakes in the 99mTc-sestamibi scan and 18F-FDG PET/CT imaging.
Sang Soo KIM ; Yun Kyung JEON ; Soo Hyung LEE ; Bo Hyun KIM ; Seong Jang KIM ; Yong Ki KIM ; In Ju KIM
The Korean Journal of Internal Medicine 2014;29(3):383-387
We report a rare case of distant subcutaneous parathyroid carcinoma recurrence. A 50-year-old woman was referred to our hospital because of sustained hypercalcemia despite surgical removal of a parathyroid carcinoma. A focal uptake in the upper mediastinal area was detected in a 99mTc-sestamibi scan, and 18F-fluorodeoxyglucose (FDG) positron-emission tomography (PET)/computed tomography (CT) imaging demonstrated a subcutaneous mass. She underwent tumor resection, and the pathological findings were consistent with a parathyroid carcinoma. The postoperative serum parathyroid hormone (PTH) level remained within normal limits. However, a new palpable solitary mass was identified in the upper portion of the left breast 1 year postoperatively. Both a 99mTc-sestamibi scan and 18F-FDG PET/CT imaging revealed an abnormal lesion in the upper breast, and subsequent pathology reports confirmed parathyroid carcinoma metastasis. Serum PTH and calcium levels fell within normal ranges after tumor resection. Two subcutaneous recurrent lesions appeared likely due to tumor seeding during the previous endoscopic operation at a local hospital.
Biological Markers/blood
;
Breast Neoplasms/blood/radiography/*radionuclide imaging/*secondary/surgery
;
Carcinoma/blood/radiography/*radionuclide imaging/*secondary/surgery
;
Female
;
Fluorodeoxyglucose F18/*diagnostic use
;
Humans
;
Middle Aged
;
Multimodal Imaging
;
Parathyroid Hormone/blood
;
Parathyroid Neoplasms/blood/*pathology/surgery
;
*Positron-Emission Tomography
;
Predictive Value of Tests
;
Radiopharmaceuticals/*diagnostic use
;
Technetium Tc 99m Sestamibi/*diagnostic use
;
Time Factors
;
*Tomography, X-Ray Computed
;
Treatment Outcome
10.Intratumoral Heterogeneity of Breast Cancer Xenograft Models: Texture Analysis of Diffusion-Weighted MR Imaging.
Bo La YUN ; Nariya CHO ; Mulan LI ; Min Hye JANG ; So Yeon PARK ; Ho Chul KANG ; Bohyoung KIM ; In Chan SONG ; Woo Kyung MOON
Korean Journal of Radiology 2014;15(5):591-604
OBJECTIVE: To investigate whether there is a relationship between texture analysis parameters of apparent diffusion coefficient (ADC) maps and histopathologic features of MCF-7 and MDA-MB-231 xenograft models. MATERIALS AND METHODS: MCF-7 estradiol (+), MCF-7 estradiol (-), and MDA-MB-231 xenograft models were made with approval of the animal care committee. Twelve tumors of MCF-7 estradiol (+), 9 tumors of MCF-7 estradiol (-), and 6 tumors in MDA-MB-231 were included. Diffusion-weighted MR images were obtained on a 9.4-T system. An analysis of the first and second order texture analysis of ADC maps was performed. The texture analysis parameters and histopathologic features were compared among these groups by the analysis of variance test. Correlations between texture parameters and histopathologic features were analyzed. We also evaluated the intraobserver agreement in assessing the texture parameters. RESULTS: MCF-7 estradiol (+) showed a higher standard deviation, maximum, skewness, and kurtosis of ADC values than MCF-7 estradiol (-) and MDA-MB-231 (p < 0.01 for all). The contrast of the MCF-7 groups was higher than that of the MDA-MB-231 (p = 0.004). The correlation (COR) of the texture analysis of MCF-7 groups was lower than that of MDA-MB-231 (p < 0.001). The histopathologic analysis showed that Ki-67mean and Ki-67diff of MCF-7 estradiol (+) were higher than that of MCF-7 estradiol (-) or MDA-MB-231 (p < 0.05). The microvessel density (MVD)mean and MVDdiff of MDA-MB-231 were higher than those of MCF-7 groups (p < 0.001). A diffuse-multifocal necrosis was more frequently found in MDA-MB-231 (p < 0.001). The proportion of necrosis moderately correlated with the contrast (r = -0.438, p = 0.022) and strongly with COR (r = 0.540, p = 0.004). Standard deviation (r = 0.622, r = 0.437), skewness (r = 0.404, r = 0.484), and kurtosis (r = 0.408, r = 0.452) correlated with Ki-67mean and Ki-67diff (p < 0.05 for all). COR moderately correlated with Ki-67diff (r = -0.388, p = 0.045). Skewness (r = -0.643, r = -0.464), kurtosis (r = -0.581, r = -0.389), contrast (r = -0.473, r = -0.549) and COR (r = 0.588, r = 0.580) correlated with MVDmean and MVDdiff (p < 0.05 for all). CONCLUSION: The texture analysis of ADC maps may help to determine the intratumoral spatial heterogeneity of necrosis patterns, amount of cellular proliferation and the vascularity in MCF-7 and MDA-MB-231 xenograft breast cancer models.
Animals
;
Breast Neoplasms/metabolism/pathology/*radiography
;
Cell Line, Tumor
;
*Diffusion Magnetic Resonance Imaging
;
Estradiol/metabolism
;
Female
;
Humans
;
Image Interpretation, Computer-Assisted
;
Immunohistochemistry
;
Ki-67 Antigen/metabolism
;
MCF-7 Cells
;
Mice
;
Mice, Nude
;
Transplantation, Heterologous

Result Analysis
Print
Save
E-mail