1.Optimal Follow-up of Incidental Pancreatic Cystic Lesions without Worrisome Features: Clinical Outcome after Long-term Follow-up
Dong-Won AHN ; Sang Hyub LEE ; Jin Ho CHOI ; In Rae CHO ; Dong Kee JANG ; Woo Hyun PAIK ; Ji Bong JEONG ; Ji Kon RYU ; Yong-Tae KIM
Gut and Liver 2024;18(2):328-337
Background/Aims:
The optimal duration and interval of follow-up for cystic lesions of the pancreas (CLPs) is not well established. This study was performed to investigate the optimal duration and interval of follow-up for CLPs in clinical practice.
Methods:
Patients with CLPs without worrisome features or high-risk stigmata underwent followup with computed tomography at 6, 12, 18, and 24 months and then every 12 months thereafter. A retrospective analysis of prospectively collected data was performed.
Results:
A total of 227 patients with CLPs detected from 2000 to 2008 (mean initial diameter, 1.3±0.6 cm) underwent follow-up for a median of 120 months. Twenty-two patients (9.7%) underwent surgery after a median of 47.5 months. Malignancies developed in four patients (1.8%), one within 5 years and three within 10 years. One hundred and fourteen patients (50.2%) were followed up for more than 10 years. No malignancy developed after 10 years of follow-up. During surveillance, 37 patients (16.3%) experienced progression to surgical indication. In patients with CLPs less than 2 cm in diameter, development of surgical indications did not occur within 24 months of follow-up.
Conclusions
CLPs should be continuously monitored after 5 years because of the persistent potential for malignant transformation of CLPs. An interval of 24 months for initial follow-up might be enough for CLPs with initial size of less than 2 cm in clinical practice.
2.Clinical safety and effectiveness of the Genoss drug-eluting stent in real-world clinical practice
Young Jin YOUN ; Jun-Won LEE ; Sung Gyun AHN ; Seung-Hwan LEE ; Junghan YOON ; Jae Hyoung PARK ; Sang-Yong YOO ; Woong Chol KANG ; Nam Ho LEE ; Ki Hwan KWON ; Joon Hyung DOH ; Sang-Wook LIM ; Yang Soo JANG ; Dong Woon JEON ; Jung Ho HEO ; Woong Gil CHOI ; Sungsoo CHO ; Bong-Ki LEE ; Hyonju JEONG ; Bum-Kee HONG ; Hyun-Hee CHOI
The Korean Journal of Internal Medicine 2023;38(5):683-691
Background/Aims:
The Genoss DES™ is a novel, biodegradable, polymer-coated, sirolimus-eluting stent with a cobalt- chromium stent platform and thin strut. Although the safety and effectiveness of this stent have been previously investigated, real-world clinical outcomes data are lacking. Therefore, the aim of this prospective, multicenter trial was to evaluate the clinical safety and effectiveness of the Genoss DES™ in all-comer patients undergoing percutaneous coronary intervention.
Methods:
The Genoss DES registry is a prospective, single-arm, observational trial for evaluation of clinical outcomes after Genoss DES™ implantation in all-comer patients undergoing percutaneous coronary intervention from 17 sites in South Korea. The primary endpoint was a device-oriented composite outcome of cardiac death, target vessel-related myocardial infarction (MI), and clinically driven target lesion revascularization (TLR) at 12 months.
Results:
A total of 1,999 patients (66.4 ± 11.1 years of age; 72.8% male) were analyzed. At baseline, 62.8% and 36.7% of patients had hypertension and diabetes, respectively. The implanted stent number, diameter, and length per patient were 1.5 ± 0.8, 3.1 ± 0.5 mm, and 37.0 ± 25.0 mm, respectively. The primary endpoint occurred in 1.8% patients, with a cardiac death rate of 1.1%, target vessel-related MI rate of 0.2%, and clinically driven TLR rate of 0.8%.
Conclusions
In this real-world registry, the Genoss DES™ demonstrated excellent safety and effectiveness at 12 months among all-comer patients undergoing percutaneous coronary intervention. These findings suggest that the Genoss DES™ may be a viable treatment option for patients with coronary artery disease.
3.Variations in Clinical Practice of Esophageal High-resolution Manometry: A Nationwide Survey
Eun Jeong GONG ; Soo In CHOI ; Bong Eun LEE ; Yang Won MIN ; Yu Kyung CHO ; Kee Wook JUNG ; Ji Hyun KIM ; Moo In PARK ;
Journal of Neurogastroenterology and Motility 2021;27(3):347-353
Background/Aims:
Esophageal high-resolution manometry (HRM) enables the comprehensive evaluation of the esophageal motor function. However, protocols are not uniform and clinical practices vary widely among institutions. This study aims to understand the current HRM practice in Korea.
Methods:
The survey was sent via email through the Korean Society of Neurogastroenterology and Motility. The questions covered descriptive information, preparation, techniques, analysis, and reporting of esophageal HRM.
Results:
The survey was completed in 32 (74.4%) out of 43 centers, including 24 tertiary and 8 secondary referral centers. Of the 32 centers, 25 (78.1%) performed HRM in a sitting position, while 7 centers (21.9%) reported performing HRM in a supine position. All the centers utilized single wet swallows as a standard, but the volume, frequency, and interval between swallows varied widely. Sixteen centers (50.0%) applied adjunctive tests, including multiple rapid swallows (n = 16) and rapid drink challenges (n = 9). Parameters assessed and documented in the report were similar. In addition to the assessment of the esophagogastric junction and esophageal body, 27 centers (84.8%) and 18 centers (56.3%) included measurements for the upper esophageal sphincter and the pharynx, respectively, in the HRM protocol.
Conclusions
We found a variation in the available HRM practice among centers, even though they broadly agreed in the data analysis. Efforts are needed to develop a standardized protocol for HRM measurement.
4.Variations in Clinical Practice of Esophageal High-resolution Manometry: A Nationwide Survey
Eun Jeong GONG ; Soo In CHOI ; Bong Eun LEE ; Yang Won MIN ; Yu Kyung CHO ; Kee Wook JUNG ; Ji Hyun KIM ; Moo In PARK ;
Journal of Neurogastroenterology and Motility 2021;27(3):347-353
Background/Aims:
Esophageal high-resolution manometry (HRM) enables the comprehensive evaluation of the esophageal motor function. However, protocols are not uniform and clinical practices vary widely among institutions. This study aims to understand the current HRM practice in Korea.
Methods:
The survey was sent via email through the Korean Society of Neurogastroenterology and Motility. The questions covered descriptive information, preparation, techniques, analysis, and reporting of esophageal HRM.
Results:
The survey was completed in 32 (74.4%) out of 43 centers, including 24 tertiary and 8 secondary referral centers. Of the 32 centers, 25 (78.1%) performed HRM in a sitting position, while 7 centers (21.9%) reported performing HRM in a supine position. All the centers utilized single wet swallows as a standard, but the volume, frequency, and interval between swallows varied widely. Sixteen centers (50.0%) applied adjunctive tests, including multiple rapid swallows (n = 16) and rapid drink challenges (n = 9). Parameters assessed and documented in the report were similar. In addition to the assessment of the esophagogastric junction and esophageal body, 27 centers (84.8%) and 18 centers (56.3%) included measurements for the upper esophageal sphincter and the pharynx, respectively, in the HRM protocol.
Conclusions
We found a variation in the available HRM practice among centers, even though they broadly agreed in the data analysis. Efforts are needed to develop a standardized protocol for HRM measurement.
5.Safety and Efficacy of a New Ultrathin Sirolimus-Eluting Stent with Abluminal Biodegradable Polymer in Real-World Practice
Young Jin YOUN ; Sang Yong YOO ; Jun Won LEE ; Sung Gyun AHN ; Seung Hwan LEE ; Junghan YOON ; Jae Hyoung PARK ; Woong Gil CHOI ; Sungsoo CHO ; Sang Wook LIM ; Yang Soo JANG ; Ki Hwan KWON ; Nam Ho LEE ; Joon Hyung DOH ; Woong Chol KANG ; Dong Woon JEON ; Bong Ki LEE ; Jung Ho HEO ; Bum Kee HONG ; Hyun Hee CHOI
Korean Circulation Journal 2020;50(4):317-327
BACKGROUND AND OBJECTIVES: Recently, Genoss drug-eluting stent (DES)™ stent comprising cobalt-chromium platform with an ultrathin strut thickness, sirolimus, and an abluminal biodegradable polymer was developed. Owing to the lack of substantial evidence for the safety and efficacy of this stent, we report 12-month results of the Genoss DES™ stent.METHODS: We analyzed subjects who were eligible for a 12-month follow-up from the ongoing Genoss DES™ registry, which is a prospective, single-arm, observational, multicenter trial to investigate the clinical outcomes after the successful Genoss DES™ stent implantation among all-comers. The primary endpoint was a device-oriented composite outcome, defined as cardiac death, target vessel-related myocardial infarction, and target lesion revascularization at 12-month follow-up.RESULTS: Among 622 subjects, the mean age of subjects was 66.5±10.4 years, 70.6% were males, 67.5% had hypertension, and 38.3% had diabetes. The implanted stent number, diameter, and length per patient were 1.5±0.8, 3.1±0.4 mm, and 36.0±23.3 mm, respectively. At 12-month clinical follow-up, the primary endpoint occurred only in 4 (0.6%) subjects.CONCLUSIONS: The novel Genoss DES™ stent exhibited excellent safety and efficacy in real-world practice.
Death
;
Drug-Eluting Stents
;
Follow-Up Studies
;
Humans
;
Hypertension
;
Male
;
Multicenter Studies as Topic
;
Myocardial Infarction
;
Percutaneous Coronary Intervention
;
Polymers
;
Prospective Studies
;
Registries
;
Sirolimus
;
Stents
6.Computed Tomography (CT) Protocols Associated with Cardiac and Bone Single-Photon Emission Computed Tomography/CT (SPECT/CT) in Korea
Eun Jeong LEE ; Ji Young KIM ; Jung Mi PARK ; Bong-Il SONG ; Hongyoon CHOI ; Hye-kyeong SHIM ; Hey Lim PARK ; Ho-Young LEE ; Kyung Jae LEE ; Joon-Kee YOON ; Seongho SEO ; Seong Min KIM ; Soo Bin PARK ; Young Seok CHO ; Seong Hoon KIM
Nuclear Medicine and Molecular Imaging 2020;54(3):139-146
Purpose:
Single-photon emission computed tomography/computed tomography (SPECT/CT) is an advanced hybrid nuclear medicine technology that generates both functional and anatomical images in a single study. As utilization of SPECT/CT in Korea has been increasing, the purpose of this study was to survey its application of cardiac and skeletal SPECT/CT imaging for protocol optimization.
Methods:
We surveyed CT protocols established for cardiac and skeletal SPECT/CT. We searched the guidelines for the CT protocols for SPECT/CT and reviewed the literature recently published.
Results:
Among 36 hybrid SPECT scanners equipped with four or more multi-channel detector CTs (MDCTs), 18 scanners were used to perform cardiac studies at both very low current CT (30–80 mA; 11.1%) and ultra-low current CT (13–30 mA; 88.9%). Among the 33 canners, very low current (≤ 80 mA) CT or low current CT (80–130 mA) was used in 23.5%, and 41.8% for spine disorders, and in 36.4% or 30.3% for foot/ankle disorders, respectively. In the CT reconstructions, slice thickness of 5 mm for cardiac studies was most commonly used (94.4%); thinner slices (0.6–1.0 mm) for spine and foot/ankle studies were used in 24.2% and 45.5%, respectively. We also reviewed the international guidelines.
Conclusions
The results and current recommendations will be helpful for optimizing CT protocols for SPECT/CT. Optimization of SPECT/CT protocols will be required for generating the proper strategy for the specific lesions and clinical purpose.
7.Safety and Efficacy of a New Ultrathin Sirolimus-Eluting Stent with Abluminal Biodegradable Polymer in Real-World Practice
Young Jin YOUN ; Sang Yong YOO ; Jun Won LEE ; Sung Gyun AHN ; Seung Hwan LEE ; Junghan YOON ; Jae Hyoung PARK ; Woong Gil CHOI ; Sungsoo CHO ; Sang Wook LIM ; Yang Soo JANG ; Ki Hwan KWON ; Nam Ho LEE ; Joon Hyung DOH ; Woong Chol KANG ; Dong Woon JEON ; Bong Ki LEE ; Jung Ho HEO ; Bum Kee HONG ; Hyun Hee CHOI
Korean Circulation Journal 2020;50(4):317-327
BACKGROUND AND OBJECTIVES:
Recently, Genoss drug-eluting stent (DES)â„¢ stent comprising cobalt-chromium platform with an ultrathin strut thickness, sirolimus, and an abluminal biodegradable polymer was developed. Owing to the lack of substantial evidence for the safety and efficacy of this stent, we report 12-month results of the Genoss DESâ„¢ stent.
METHODS:
We analyzed subjects who were eligible for a 12-month follow-up from the ongoing Genoss DESâ„¢ registry, which is a prospective, single-arm, observational, multicenter trial to investigate the clinical outcomes after the successful Genoss DESâ„¢ stent implantation among all-comers. The primary endpoint was a device-oriented composite outcome, defined as cardiac death, target vessel-related myocardial infarction, and target lesion revascularization at 12-month follow-up.
RESULTS:
Among 622 subjects, the mean age of subjects was 66.5±10.4 years, 70.6% were males, 67.5% had hypertension, and 38.3% had diabetes. The implanted stent number, diameter, and length per patient were 1.5±0.8, 3.1±0.4 mm, and 36.0±23.3 mm, respectively. At 12-month clinical follow-up, the primary endpoint occurred only in 4 (0.6%) subjects.
CONCLUSIONS
The novel Genoss DESâ„¢ stent exhibited excellent safety and efficacy in real-world practice.
8.Comparison of Fentanyl versus Meperidine in Combination with Midazolam for Sedative Colonoscopy in Korea
Gwan Woo HONG ; Jun Kyu LEE ; Jung Hyeon LEE ; Ji Hun BONG ; Sung Hun CHOI ; Hyeki CHO ; Ji Hyung NAM ; Dong Kee JANG ; Hyoun Woo KANG ; Jae Hak KIM ; Yun Jeong LIM ; Moon Soo KOH ; Jin Ho LEE
Clinical Endoscopy 2020;53(5):562-567
Background/Aims:
Combination of midazolam and opioids is used widely for endoscopic sedation. Compared with meperidine, fentanyl is reportedly associated with rapid recovery, turnover rate of endoscopy room, and quality of endoscopy. We compared fentanyl with meperidine when combined with midazolam for sedative colonoscopy.
Methods:
A retrospective, cross-sectional, 1:2 matching study was conducted. Induction and recovery time were compared as the primary outcomes. Moreover, cecal intubation time, withdrawal time, total procedure time of colonoscopy, paradoxical reaction, adenoma detection rate, and adverse effect of midazolam or opioids were assessed as the secondary outcomes.
Results:
A total of 129 subjects (43 fentanyl vs. 86 meperidine) were included in the analysis. The fentanyl group showed significantly more rapid induction time (4.5±2.7 min vs. 7.5±4.7 min, p<0.001), but longer recovery time (59.5±25.6 min vs. 50.3±10.9 min, p=0.030) than the meperidine group. In multivariate analysis, the induction time of the fentanyl group was 3.40 min faster (p<0.001), but the recovery time was 6.38 min longer (p=0.046) than that of the meperidine group. There was no difference in withdrawal time and adenoma detection rate between the two groups.
Conclusions
The fentanyl group had more rapid sedation induction time but longer recovery time than the meperidine group.
9.Vegetarianism as a protective factor for asymptomatic colonic diverticulosis in Asians: a retrospective cross-sectional and case-control study
Jihun BONG ; Hyoun Woo KANG ; Hyeki CHO ; Ji Hyung NAM ; Dong Kee JANG ; Jae Hak KIM ; Jun Kyu LEE ; Yun Jeong LIM ; Moon-Soo KOH ; Jin Ho LEE
Intestinal Research 2020;18(1):121-129
Background/Aims:
Dietary fiber intake is considered a protective factor for diverticular disease such as diverticulitis. However, evidence for an inverse connection between dietary fiber consumption and asymptomatic colonic diverticulosis is lacking. Specifically, few studies have investigated this subject in Asians with different presentations of diverticulosis. Therefore, we assessed the protective effects of a vegetarian diet for asymptomatic colonic diverticulosis in Buddhist monks who are obligatory vegetarians for spiritual reasons compared with the general population.
Methods:
A retrospective, cross-sectional, case-control study was conducted in age- and sex-matched Buddhist monks and the general population who underwent colonoscopy for screening at a Korean health promotion center from August 2005 to June 2018. We compared the prevalence of asymptomatic diverticulosis between the 2 groups using a self-administered questionnaire.
Results:
In this study, a total of 1,316 individuals were included (Buddhist monks of 658 and general population of 658) with a mean age of 52.6±9.5 years. The prevalence of asymptomatic diverticulosis in Buddhist monks was lower compared with the general population (6.7% [44/658] vs. 10.8% [71/658], P=0.008). Buddhist monks had a higher rate of high body mass index (BMI) and metabolic syndrome. By a multivariate regression analysis model, a nonvegetarian diet (odds ratio [OR], 1.82; 95% confidence interval [CI], 1.21–2.72, P=0.004), old age (OR, 4.53; 95% CI, 1.36–15.12; P=0.014), male sex (OR, 1.91; 95% CI, 1.28–2.85; P=0.002), and a high BMI (OR, 1.50; 95% CI, 1.01–2.23; P=0.047) were independent predictors of asymptomatic diverticulosis. Moreover, a nonvegetarian diet was associated with both right-sided and left-sided diverticulosis.
Conclusions
A nonvegetarian diet may increase a risk of asymptomatic colonic diverticulosis in Asians.
10.Epicardial Fat Thickness is Correlated with Vagal Hyperactivity in Patients with Neurally-Mediated Syncope.
Kyoung Im CHO ; Young Soo LEE ; Byong Kyu KIM ; Bong Joon KIM ; Kee Sik KIM
Journal of Cardiovascular Ultrasound 2017;25(2):57-62
BACKGROUND: Epicardial fat tissue has unique endocrine and paracrine functions that affect the cardiac autonomic system. The head-up tilt test (HUTT) is a simple non-invasive measurement that assesses autonomic nervous system dysfunction. We investigated the association between epicardial fat thickness (EFT) and autonomic neural tone, such as vagal tone. METHODS: A total of 797 consecutive patients (mean age 46.5 years, male: 45.7%) who underwent HUTT and echocardiography between March 2006 and June 2015 were enrolled. EFT was measured during the diastolic phase of the parasternal long axis view. We excluded patients with prior percutaneous coronary intervention, old age (* 70 years old), valvular heart disease, symptomatic arrhythmias and diabetes. We divided patients into two groups based on the HUTT (positive vs. negative). RESULTS: There were 329 patients (41.3%) with a negative HUTT result and 468 patients (58.7%) with a positive result. The HUTT-positive patients showed a significantly lower waist circumference, body mass index and systolic and diastolic blood pressure, although a significantly higher EFT as compared to the HUTT-negative patients (HUTT-positive, 5.69 ± 1.76 mm vs. HUTT-negative, 5.24 ± 1.60 mm; p < 0.001). EFT > 5.4 mm was associated with a positive HUTT result with 51.7% sensitivity and 63.8% specificity (p < 0.001) on receiving operator characteristic analysis. Multivariate Cox regression analysis revealed that EFT (hazard ratio: 1.02, 95% confidence interval: 1.01–1.30, p = 0.004) was an independent predictor of HUTT-positivity. CONCLSION: EFT was significantly correlated with positive HUTT, which suggests an association between EFT and autonomic dysregulation.
Arrhythmias, Cardiac
;
Autonomic Nervous System
;
Blood Pressure
;
Body Mass Index
;
Echocardiography
;
Heart Valve Diseases
;
Humans
;
Male
;
Percutaneous Coronary Intervention
;
Sensitivity and Specificity
;
Syncope*
;
Syncope, Vasovagal
;
Waist Circumference

Result Analysis
Print
Save
E-mail