1.Korean clinical practice guidelines for diagnostic and procedural sedation
Sang-Hyun KIM ; Young-Jin MOON ; Min Suk CHAE ; Yea-Ji LEE ; Myong-Hwan KARM ; Eun-Young JOO ; Jeong-Jin MIN ; Bon-Nyeo KOO ; Jeong-Hyun CHOI ; Jin-Young HWANG ; Yeonmi YANG ; Min A KWON ; Hyun Jung KOH ; Jong Yeop KIM ; Sun Young PARK ; Hyunjee KIM ; Yang-Hoon CHUNG ; Na Young KIM ; Sung Uk CHOI
Korean Journal of Anesthesiology 2024;77(1):5-30
Safe and effective sedation depends on various factors, such as the choice of sedatives, sedation techniques used, experience of the sedation provider, degree of sedation-related education and training, equipment and healthcare worker availability, the patient’s underlying diseases, and the procedure being performed. The purpose of these evidence-based multidisciplinary clinical practice guidelines is to ensure the safety and efficacy of sedation, thereby contributing to patient safety and ultimately improving public health. These clinical practice guidelines comprise 15 key questions covering various topics related to the following: the sedation providers; medications and equipment available; appropriate patient selection; anesthesiologist referrals for high-risk patients; pre-sedation fasting; comparison of representative drugs used in adult and pediatric patients; respiratory system, cardiovascular system, and sedation depth monitoring during sedation; management of respiratory complications during pediatric sedation; and discharge criteria. The recommendations in these clinical practice guidelines were systematically developed to assist providers and patients in sedation-related decision making for diagnostic and therapeutic examinations or procedures. Depending on the characteristics of primary, secondary, and tertiary care institutions as well as the clinical needs and limitations, sedation providers at each medical institution may choose to apply the recommendations as they are, modify them appropriately, or reject them completely.
2.Efficacy of intraoperative blood salvage and autotransfusion in living-donor liver transplantation: a retrospective cohort study
Jongchan LEE ; Sujung PARK ; Jae Geun LEE ; Sungji CHOO ; Bon-Nyeo KOO
Korean Journal of Anesthesiology 2024;77(3):345-352
Background:
Liver transplantation (LT) may be associated with massive blood loss and the need for allogeneic blood transfusion. Intraoperative blood salvage autotransfusion (IBSA) can reduce the need for allogeneic blood transfusion. This study aimed to investigate the effectiveness of blood salvage in LT.
Methods:
Among 355 adult patients who underwent elective living-donor LT between January 1, 2019, and December 31, 2022, 59 recipients without advanced hepatocellular carcinoma received IBSA using Cell Saver (CS group). Based on sex, age, model for end-stage liver disease (MELD) score, preoperative laboratory results, and other factors, 118 of the 296 recipients who did not undergo IBSA were matched using propensity score (non-CS group). The primary outcome was the amount of intraoperative allogenic red blood cell (RBC) transfusion. Comparisons were made between the two groups regarding the amount of other blood components transfused and postoperative laboratory findings.
Results:
The transfused allogeneic RBC for the CS group was significantly lower than that of the non-CS group (1,506.0 vs. 1,957.5 ml, P = 0.026). No significant differences in the transfused total fresh frozen plasma, platelets, cryoprecipitate, and estimated blood loss were observed between the two groups. The postoperative allogeneic RBC transfusion was significantly lower in the CS group than in the non-CS group (1,500.0 vs. 2,100.0 ml, P = 0.039). No significant differences in postoperative laboratory findings were observed at postoperative day 1 and discharge.
Conclusions
Using IBSA during LT can effectively reduce the need for perioperative allogeneic blood transfusions without causing subsequent coagulopathy.
3.Assessment of Risk Factors for Postoperative Delirium in Older Adults Who Underwent Spinal Surgery and Identifying Associated Biomarkers Using Exosomal Protein
Wonhee BAEK ; JuHee LEE ; Yeonsoo JANG ; Jeongmin KIM ; Dong Ah SHIN ; Hyunki PARK ; Bon-Nyeo KOO ; Hyangkyu LEE
Journal of Korean Academy of Nursing 2023;53(4):371-384
Purpose:
With an increase in the aging population, the number of patients with degenerative spinal diseases undergoing surgery has risen, as has the incidence of postoperative delirium. This study aimed to investigate the risk factors affecting postoperative delirium in older adults who had undergone spine surgery and to identify the associated biomarkers.
Methods:
This study is a prospective study. Data of 100 patients aged ≥ 70 years who underwent spinal surgery were analyzed. Demographic data, medical history, clinical characteristics, cognitive function, depression symptoms, functional status, frailty, and nutritional status were investigated to identify the risk factors for delirium. The Confusion Assessment Method, Delirium Rating Scale-R-98, and Nursing Delirium Scale were also used for diagnosing deliri-um. To discover the biomarkers, urine extracellular vesicles (EVs) were analyzed for tau, ubiquitin carboxy-terminal hydrolase L1 (UCH-L1),neurofilament light, and glial fibrillary acidic protein using digital immunoassay technology.
Results:
Nine patients were excluded, and data obtained from the remaining 91 were analyzed. Among them, 18 (19.8%) developed delirium. Differences were observed between partici-pants with and without delirium in the contexts of a history of mental disorder and use of benzodiazepines (p = .005 and p = .026, respectively). Tau and UCH-L1—concentrations of urine EVs—were comparatively higher in participants with severe delirium than that in partici-pants without delirium (p = .002 and p = .001, respectively).
Conclusion
These findings can assist clinicians in accurately identifying the risk factors before surgery, classifying high-risk patients, and predicting and detecting delirium in older patients. Moreover, urine EV analysis revealed that postoperative delirium following spinal surgery is most likely associated with brain damage.
4.Effects of the Type of Intraoperative Fluid in Living Donor Kidney Transplantation: A Single-Center Retrospective Cohort Study
Seungho JUNG ; Jeongmin KIM ; Juhan LEE ; Su Youn CHOI ; Hye Ji JOO ; Bon-Nyeo KOO
Yonsei Medical Journal 2022;63(4):380-388
Purpose:
Perioperative fluid management in kidney transplant recipients is crucial to supporting the fluid, acid-base, and electrolyte balance required for graft perfusion. However, the choice of intraoperative crystalloids in kidney transplantation remains controversial. We conducted a single-center retrospective cohort study to evaluate the impact of intraoperative fluids on acidbase and electrolyte balance and graft outcomes.
Materials and Methods:
We included 282 living donor kidney transplant recipients from January 2010 to December 2017. Patients were classified into two groups based on the type of intraoperative crystalloids used (157 patients in the half saline group and 125 patients in the balanced crystalloid solutions group, Plasma-lyte).
Results:
Compared with the half saline group, the Plasma-lyte group showed less metabolic acidosis and hyponatremia during surgery. Hyperkalemia incidence was not significantly different between the two groups. Changes in postoperative graft function assessed by blood urea nitrogen and creatinine were significantly different between the two groups. Patients in the Plasma-lyte group exhibited consistently higher glomerular filtration rates than those in the half saline group at 1 month and 1 year after transplantation after adjusting for demographic differences.
Conclusion
Intraoperative Plasma-lyte can lead to more favorable results in terms of acid-base balance during kidney transplantation. Patients who received Plasma-lyte showed superior postoperative graft function at 1 month and 1 year after transplantation.Further studies are needed to evaluate the superiority of intraoperative Plasma-lyte over other types of crystalloids in relation to graft outcomes.
5.Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients
Ha Yeon KIM ; Sung-Yeon HAM ; Eun Jung KIM ; Hei Jin YOON ; Seung Yeon CHOI ; Bon-Nyeo KOO
Yonsei Medical Journal 2021;62(6):503-509
Purpose:
Children have few small alveoli, which reduce lung compliance; in contrast, their cartilaginous rib cage makes their chest wall highly compliant. This combination promotes lung collapse. Prolonged inspiratory to expiratory (I:E) ratio ventilation is used to optimize gas exchange and respiratory mechanics in surgery. However, the optimal ratio is unclear in children. We hypothesized that, compared to a 1:2 I:E ratio, a 1:1 I:E ratio would improve dynamic compliance and oxygenation, and affect the peak airway pressure in pediatric patients undergoing surgery.
Materials and Methods:
Forty-eight patients aged ≤6 years who were scheduled to undergo surgery under general anesthesia with an arterial line were randomly allocated to receive 1:1 (group 1:1) or 1:2 (group 1:2) I:E ratio ventilation. Airway pressure, respiratory system compliance, and arterial blood gas analyses were compared between groups immediately after induction (T0), 30 min after induction (T1), 60 min after induction (T2), immediately after surgery (T3), and on arrival at the post-anesthesia care unit (T4).
Results:
Peak and plateau airway pressures were significantly lower in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.048, respectively). The dynamic and static compliances were significantly higher in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.045, respectively). However, the partial pressure of oxygen did not significantly differ between groups.
Conclusion
Compared to a 1:2 I:E ratio, a 1:1 I:E ratio improved dynamic compliance and lowered the peak airway pressure without complications in pediatric patients. Nevertheless, our results do not support its use solely for improving oxygenation.
6.Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients
Ha Yeon KIM ; Sung-Yeon HAM ; Eun Jung KIM ; Hei Jin YOON ; Seung Yeon CHOI ; Bon-Nyeo KOO
Yonsei Medical Journal 2021;62(6):503-509
Purpose:
Children have few small alveoli, which reduce lung compliance; in contrast, their cartilaginous rib cage makes their chest wall highly compliant. This combination promotes lung collapse. Prolonged inspiratory to expiratory (I:E) ratio ventilation is used to optimize gas exchange and respiratory mechanics in surgery. However, the optimal ratio is unclear in children. We hypothesized that, compared to a 1:2 I:E ratio, a 1:1 I:E ratio would improve dynamic compliance and oxygenation, and affect the peak airway pressure in pediatric patients undergoing surgery.
Materials and Methods:
Forty-eight patients aged ≤6 years who were scheduled to undergo surgery under general anesthesia with an arterial line were randomly allocated to receive 1:1 (group 1:1) or 1:2 (group 1:2) I:E ratio ventilation. Airway pressure, respiratory system compliance, and arterial blood gas analyses were compared between groups immediately after induction (T0), 30 min after induction (T1), 60 min after induction (T2), immediately after surgery (T3), and on arrival at the post-anesthesia care unit (T4).
Results:
Peak and plateau airway pressures were significantly lower in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.048, respectively). The dynamic and static compliances were significantly higher in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.045, respectively). However, the partial pressure of oxygen did not significantly differ between groups.
Conclusion
Compared to a 1:2 I:E ratio, a 1:1 I:E ratio improved dynamic compliance and lowered the peak airway pressure without complications in pediatric patients. Nevertheless, our results do not support its use solely for improving oxygenation.
7.Ability of dynamic preload indices to predict fluid responsiveness in a high femoral-to-radial arterial pressure gradient: a retrospective study
Seon Ju KIM ; So Yeon KIM ; Hye Sun LEE ; Goeun PARK ; Eun Jang YOON ; Sungtaik HEO ; Bon-Nyeo KOO
Anesthesia and Pain Medicine 2021;16(4):360-367
Background:
Dynamic preload indices may predict fluid responsiveness in end-stage liver disease. However, their usefulness in patients with altered vascular compliance is uncertain. This study is the first to evaluate whether dynamic indices can reliably predict fluid responsiveness in patients undergoing liver transplantation with a high femoral-to-radial arterial pressure gradient (PG).
Methods:
80 liver transplant recipients were retrospectively categorized as having a normal (n = 56) or high (n = 24, difference in systolic pressure ≥ 10 mmHg and/or mean pressure ≥ 5 mmHg) femoral-to-radial arterial PG, measured immediately after radial and femoral arterial cannulation. The ability of dynamic preload indices (stroke volume variation, pulse pressure variation [PPV], pleth variability index) to predict fluid responsiveness was assessed before the surgery. Fluid replacement of 500 ml of crystalloid solution was performed over 15 min. Fluid responsiveness was defined as ≥ 15% increase in the stroke volume index. The area under the receiver-operating characteristic curve (AUC) indicated the prediction of fluid responsiveness.
Results:
Fourteen patients in the normal, and eight in the high PG group were fluid responders. The AUCs for PPV in the normal, high PG groups and total patients were 0.702 (95% confidence interval [CI] 0.553–0.851, P = 0.008), 0.633 (95% CI 0.384–0.881, P = 0.295) and 0.667 (95% CI 0.537–0.798, P = 0.012), respectively. No other index predicted fluid responsiveness.
Conclusion
PPV can be used as a dynamic index of fluid responsiveness in patients with end-stage liver disease but not in patients with altered vascular compliance.
9.Successful wire-guided fiberoptic nasotracheal intubation in a patient with hemifacial microsomia - A case report -
Seon Ju KIM ; Haeyeon LEE ; Seung Yeon CHOI ; Bon-Nyeo KOO
Anesthesia and Pain Medicine 2020;15(1):73-77
Background:
Patients with hemifacial microsomia may have a difficult airway due to the accompanying mandibular deformity. Fiberoptic bronchoscope-guided intubation is commonly used method for difficult airway management. However, awake fiberoptic nasotracheal intubation has several disadvantages, including difficulty in advancement of the endotracheal tube (ETT) due to the resistance between the ETT and bronchoscope. Wire-guided fiberoptic nasotracheal intubation may help to overcome the drawbacks of the conventional method.Case: An 18-year-old man with hemifacial microsomia was scheduled for double-jaw surgery. In preoperative evaluation, he had severe retrognathia and expected difficult airway. We successfully performed wire-guided fiberoptic nasotracheal intubation combined with high-flow nasal cannula and deep sedation without any complications.
Conclusions
A guidewire may be useful, in case of difficultly in advancing the ETT or if a smaller tube is required, while performing intubation with FOB in patients with difficult airways.
10.Bile duct ligation of C57BL/6 mice as a model of hepatic encephalopathy
Inja CHO ; Bon-Nyeo KOO ; Eun Hee KAM ; Su Kyoung LEE ; Hanseul OH ; So Yeon KIM
Anesthesia and Pain Medicine 2020;15(1):19-27
Background:
Bile duct ligation (BDL) has been used for experimental research on hepatic encephalopathy (HE) caused by chronic liver disease. However, little research has been done on a BDL model in C57BL/6 mouse. Therefore, we evaluated the suitability of a BDL model in C57BL/6 mouse for the study of HE and determined which behavioral tests are appropriate for the identification of HE in this model.
Methods:
Twelve to fourteen-week-old male C57BL/6 mice were randomly assigned to either sham group or BDL group. Histological changes in liver were confirmed by hematoxylin/ eosin and Masson’s trichrome staining. Liver function alterations were detected by alanine aminotransferase (ALT) and ammonia levels. To identify behavioral changes, open field, elevated plus maze, novel object recognition, and passive avoidance tests were performed.
Results:
Inflammatory liver injury and fibrosis were observed 14 days after BDL. ALT and ammonia levels were significantly higher in BDL group than in sham group. There were no differences in general locomotor activity or anxiety between the groups. No difference was observed between these two groups in the novel object recognition test, but BDL group showed significant learning/memory impairment in the passive avoidance test compared to sham group.
Conclusions
Fourteen days of BDL in 12–14-week-old male C57BL/6 mice is a clinically relevant model for HE, as these mice have liver fibrosis with impaired liver function, hyperammonemia, and learning/memory impairment. Passive avoidance can be used as the major behavioral test in this model of HE.

Result Analysis
Print
Save
E-mail