1.Association of poor sleep characteristics with coexistence of negative emotions and overweight/obesity among college students
ZHANG Lisha*, LI Huihua, ZHANG Lifang, SONG Yongjing, SONG Jiancai, HUANG Bo
Chinese Journal of School Health 2025;46(8):1160-1165
Objective:
To analyze the association between poor sleep characteristics and the coexistence of negative emotions and overweight/obesity among college students, so as to provide a scientific basis for improving their physical and mental health.
Methods:
From November to December 2023, a convenience sampling method was used to survey 6 600 college students from nine universities in Jiangxi, Hunan, and Hubei provinces. The Depression Anxiety and Stress Scale-21 (DASS-21), Insomnia Severity Index (ISI), Pittsburgh Sleep Quality Index (PSQI), and physical examinations were employed to assess negative emotions, poor sleep characteristics, and overweight/obesity. Chi square test and Logistic regression were used to analyze the impact of poor sleep characteristics on the coexistence of negative emotions and overweight/obesity.
Results:
The coexistence rates of different categories of negative emotions (depression, anxiety, stress) and overweight/obesity were 6.1% ( n= 405), 8.0% ( n =529), and 3.3% ( n =217), respectively. Gender, grade level, major, maternal education level, annual family income, physical activity level, only child status, and carbonated beverage consumption were statistically associated with the coexistence rates of different categories of negative emotions and overweight/obesity ( χ 2=4.01-35.18, all P <0.05). Logistic regression analysis showed that after adjusting for gender, grade level, major, only child status, maternal education level, annual family income, physical activity level, and carbonated beverage consumption, poor sleep characteristics were significantly associated with an increased risk of the coexistence of negative emotions and overweight/obesity ( OR =1.41-6.65); moderate and poor sleep quality levels were significantly associated with an increased risk of the coexistence of different categories of negative emotions and overweight/obesity among female students ( OR =1.99-4.71) (all P <0.05).
Conclusions
Poor sleep characteristics are associated with the coexistence of negative emotions and overweight/obesity among college students. Greater attention should be paid to sleep issues in this population, and sleep education should be actively promoted to reduce the risk of comorbid negative emotions and overweight/obesity.
2.Discovery of proqodine A derivatives with antitumor activity targeting NAD(P)H: quinone oxidoreductase 1 and nicotinamide phosphoribosyltransferase.
Jiangzhou SONG ; Guiqing ZOU ; Zhou ZHAO ; Ya ZHU ; Jiayu XUE ; Lanjia AO ; Huiyong SUN ; Haiping HAO ; Bo ZHANG ; Xiaowei XU
Chinese Journal of Natural Medicines (English Ed.) 2024;22(1):75-88
NAD(P)H: quinone oxidoreductase 1 (NQO1) is a flavin protease highly expressed in various cancer cells. NQO1 catalyzes a futile redox cycle in substrates, leading to substantial reactive oxygen species (ROS) production. This ROS generation results in extensive DNA damage and elevated poly (ADP-ribose) polymerase 1 (PARP1)-mediated consumption of nicotinamide adenine dinucleotide (NAD+), ultimately causing cell death. Nicotinamide phosphoribosyltransferase (NAMPT), the rate-limiting enzyme in the NAD+ salvage synthesis pathway, emerges as a critical target in cancer therapy. The concurrent inhibition of NQO1 and NAMPT triggers hyperactivation of PARP1 and intensive NAD+ depletion. In this study, we designed, synthesized, and assessed a novel series of proqodine A derivatives targeting both NQO1 and NAMPT. Among these, compound T8 demonstrated potent antitumor properties. Specifically, T8 selectively inhibited the proliferation of MCF-7 cells and induced apoptosis through mechanisms dependent on both NQO1 and NAMPT. This discovery offers a promising new molecular entity for advancing anticancer research.
Humans
;
NAD/metabolism*
;
Cell Line, Tumor
;
Reactive Oxygen Species/metabolism*
;
Nicotinamide Phosphoribosyltransferase/metabolism*
;
Cytokines/metabolism*
;
Quinones
;
Oxidoreductases
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Bioequivalence and pharmacokinetic study of olmesartan medoxomil and hydrochlorothiazide tablets in Chinese healthy subjects
Qi-Qi ZHANG ; Xian-Gen XU ; Jin-Fang LOU ; Bo-Fan SONG ; Chun-Guang YANG ; Guang-Hui ZHU ; Ting LI
The Chinese Journal of Clinical Pharmacology 2024;40(11):1623-1627
Objective To study the bioequivalence and safety of two olmesartan medoxomil and hydrochlorothiazide tablets in Chinese healthy subjects.Methods A total of 24 healthy subjects underwent fasting and postprandial tests in a single-center,randomized,open-label,single-dose,two-formulation,two-sequence,two-period,self-cross-over controlled design.The subjects were administered a single oral dose of the test formulation and reference formulation(each containingolmesartan medoxomil 20 mg and hydrochlorothiazide 12.5 mg)in a random cross-over fashion.The plasma concentrations of olmesartan and hydrochlorothiazide were determined by LC-MS/MS.The non-compartmental model analysis of olmesartan and hydrochlorothiazide was conducted using WinNonlin 7.0 software to calculate pharmacokinetic parameters and assess bioequivalence.Results In the fasting test,the pharmacokinetic parameters of olmesartan of test and reference were as follows:Cmax were(798.35±206.78)and(664.52±168.25)ng·mL-1,AUC0-t were(4 430.71±1 294.87)and(3 976.67±1 083.54)h·ng·mL-1,AUC0-∞ were(4 551.67±1 303.06)and(4 090.37±1 103.97)h·ng·mL-1.The pharmacokinetic parameters of hydrochlorothiazide of test and reference were as follows:Cmax were(92.39±35.96)and(96.15±38.76)ng·mL-1,AUC0_t were(548.69±217.11)and(564.41±208.68)h·ng·mL-1,AUC0-∞ were(603.04±228.59)and(619.26±223.27)h·ng·mL-1.In the fed test,the pharmacokinetic parameters of olmesartan of T and R were as follows:Cmax were(583.15±149.48)and(550.57±104.76)ng·mL-1,AUC0-t were(3 585.18±952.72)and(3 292.19±904.58)h·ng·mL-1,AUC0-∞ were(3 696.05±996.55)and(3 396.30±923.41)h·ng·mL-1.The pharmacokinetic parameters of hydrochlorothiazide of test and reference were as follows:Cmax were(70.30±17.88)and(74.70±21.65)ng·mL-1,AUC0-t were(476.60±119.39)and(492.91±144.81)h·ng·mL-1,AUC0-∞ were(523.37±132.67)and(535.81±151.92)h·ng·mL-1.In fasting and fed condition,the 90%confidence interval(90%CI)of Cmax,AUC0-t and AUC0-∞ of olmesartan and hydrochlorothiazide were in 80.00%-125.00%.Conclusion The two olmesartan medoxomil and hydrochlorothiazide tablets were bioequivalent under fasting and fed conditions,and good security.
7.Research status of AQP5 regulation of programmed cell death in chronic obstructive pulmonary disease
Cheng-Cai YUN ; Li-Ying ZHANG ; Hong-Dou HOU ; Huan-Huan ZHANG ; Zhang-Bo SONG ; Wen-Xing YONG
The Chinese Journal of Clinical Pharmacology 2024;40(14):2134-2138
Aquaporin 5(AQP5),as the main water transport protein in the body,can regulate lung diseases by regulating airway mucus secretion,pulmonary inflammation,and lung function.Programmed cell death(PCD)plays a crucial role in chronic obstructive pulmonary disease(COPD).AQP5 may affect the development of COPD by regulating PCDs.This article reviews the molecular regulatory mechanism of AQP5 on apoptosis,autophagy,iron death and pyroptosis in PCDs in recent years,and further discusses its effect on COPD in order to provide theoretical support for clinical prevention and treatment of COPD.
8.Protective effects of citicoline sodium on developmental convulsive cerebral injury in rats
Bo ZHANG ; Xiao-Dong ZHAO ; Cheng XU ; Lei SONG
The Chinese Journal of Clinical Pharmacology 2024;40(17):2528-2532
Objective To explore the protective effect and mechanism of citicoline sodium on developmental convulsive cerebral injury in rats.Method SD rats were randomly divided into control group,model group and experimental group with 10 in each group.The rat developmental convulsive model was established by intraperitoneal injection of lithium chloride,scopolamine hydrobromide and pilocarpine.After successful modeling,the rats in experimental group were intraperitoneally injected with cytidine sodium(500 mg·kg-1)once a day for one week.The control group and the model group were intraperitoneally injected with the same amount of 0.9%NaCl at the same time point.Griess detection of nitric oxide(NO)concentration in serum;enzyme-linked immunosorbent assay(ELISA)detection of interleukin-6(IL-6)and interleukin-1 β(IL-1β)content in cerebrum;biochemical detection detection of superoxide dismutase(SOD)activity and malondialdehyde(MDA)content in cerebrum;real-time quantitative polymerase chain reaction(qRT-PCR)detection of mRNA levels of inducible nitric oxide synthase(iNOS)in cerebrum;Western blot detection of protein levels of G protein-coupled receptors 39 antibody(GPR39),protein kinase B(AKT),and extracellular regulated protein kinases(ERK)in cerebrum.Results In control group,model group and experimental group,the level of IL-6 in rats cerebrum were(37.16±6.34),(119.31±19.26)and(74.52±12.37)pg·mL-1,respectively;the contents of IL-1 β were(7.46±1.25),(42.73±8.41)and(24.18±4.62)pg·mL-1,respectively;SOD activity were(384.51±34.72),(229.16±27.42)and(218.47±33.59)U·gp-1,respectively;MDA content were(1.06±0.15),(1.82±0.21)and(1.24±0.17)U·gp-1,respectively;serum NO levels were(13.62±2.06),(29.34±5.37)and(16.55±3.15)μmol·L-1,respectively;mRNA levels of iNOS were 1.00±0.15,2.19±0.24 and 1.62±0.18,respectively;protein levels of GPR39 were 0.41±0.05,1.03±0.19 and 0.74±0.08,respectively;p-AKT/AKT values were 0.46±0.07,0.13±0.04 and 0.36±0.05,respectively;p-ERK/ERK values were 0.37±0.11,0.11±0.03 and 0.42±0.05,respectively.The above indicators showed statistically significant differences between the control group and the model group(P<0.01,P<0.001);the difference between the model group and the experimental group was statistically significant(P<0.05,P<0.01,P<0.001).Conclusion Cytidine sodium can effectively alleviate the degree of developmental convulsive cerebral injury rats,inhibit inflammatory reactions,and improve oxidative stress.Its mechanism may be related to the activation of GPR39/AKT/ERK signaling pathway.
9.Anatomical investigation of the venous system in pedicled nasal septal mucosal flap and its application in nasal skull base reconstruction
Kai XUE ; Bo PENG ; Huankang ZHANG ; Quan LIU ; Shixing ZHENG ; Wanpeng LI ; Xiaole SONG ; Ye GU ; Xicai SUN ; Hongmeng YU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2024;59(11):1205-1209
Objective:To investigate the distribution and primary drainage sites of the venous drainage system in the pedicled nasal septal mucosal flap, as well as to examine protective measures for the venous system of the nasal septal mucosal flap and its application in repairing the nasal skull base through the anatomical study of the nasal septum mucosal venous system in cadavers.Methods:Gross anatomy dissections were performed on 13 sides perfused fresh frozen cadaveric head specimens. The nasal septum mucosal flap was separated along the perichondrium and subperiosteum, then passed across the vomer, anterior wall of sphenoid sinus, clivus, and towards the anterior edge of vertical plate of palatine bone. Detailed documentation, including photographs, was made to record the morphology, distribution and drainage location of veins of the nasal septum mucosal flap and its pedicle, along with number of sphenopalatine veins. Furthermore, venous injuries resulting from obtaining a pedicled nasal septal mucosa flap were observed. From March 2023 to March 2024, a retrospective analysis was conducted on patients with nasopharyngeal lesions who underwent surgical repair using a modified pedicled nasal septum mucosal flap for venous system protection in the ENT institute and Department of Otorhinolaryngology at the Eye & ENT Hospital of Fudan University. The postoperative endoscopy was employed to assess the viability of the mucosal flap.Results:The veins of the nasal septum mucosa were primarily located in the posterior region, including the vomerine region, anterior wall of the sphenoid sinus, clivus region, and posterolateral wall of the nasal cavity, in a reticular pattern. Perforating veins draining into these bony structures could be observed, although their quantity and morphology varied. Notably, no prominent sphenopalatine veins were identified in 10 specimens examined, while 3 specimens exhibited sphenopalatine veins: one with a small single branch and two with venous bundles. Preservation of the nasal septal vein was possible when dissection was limited to the anterior edge of the wing of vomer. A wider range of dissection increased the risk of veinous injury. In cases where only vascular pedicles at the sphenopalatine foramen were preserved, three cadaveric head specimens retained intact sphenopalatine veins, while drainage veins were completely destroyed in ten other specimens. Fifteen patients with unilateral lesions (8 with recurrent nasopharyngeal carcinoma and 7 with nasopharyngeal radionecrosis) were included in this study. The postoperative reconstructions were carried out using contralateral pedicled nasal septal mucosal flaps. The average follow-up time was 7 months (ranging from 3 to 12 months), and all the nasal septal mucosal flaps survived.Conclusions:The primary location of the drainage vein within the nasal septum mucosa is situated in its posterior region, where it penetrates into adjacent bone structures. Very few sphenopalatine veins pass through the sphenopalatine foramen. Extensive dissection of the pedicled nasal septal mucosal flap may potentially impair the venous system and adversely affect flap survival rates, necessitating further clinical exploration.
10.National bloodstream infection bacterial resistance surveillance report (2022) : Gram-negative bacteria
Zhiying LIU ; Yunbo CHEN ; Jinru JI ; Chaoqun YING ; Qing YANG ; Haishen KONG ; Haifeng MAO ; Hui DING ; Pengpeng TIAN ; Jiangqin SONG ; Yongyun LIU ; Jiliang WANG ; Yan JIN ; Yuanyuan DAI ; Yizheng ZHOU ; Yan GENG ; Fenghong CHEN ; Lu WANG ; Yanyan LI ; Dan LIU ; Peng ZHANG ; Junmin CAO ; Xiaoyan LI ; Dijing SONG ; Xinhua QIANG ; Yanhong LI ; Qiuying ZHANG ; Guolin LIAO ; Ying HUANG ; Baohua ZHANG ; Liang GUO ; Aiyun LI ; Haiquan KANG ; Donghong HUANG ; Sijin MAN ; Zhuo LI ; Youdong YIN ; Kunpeng LIANG ; Haixin DONG ; Donghua LIU ; Hongyun XU ; Yinqiao DONG ; Rong XU ; Lin ZHENG ; Shuyan HU ; Jian LI ; Qiang LIU ; Liang LUAN ; Jilu SHEN ; Lixia ZHANG ; Bo QUAN ; Xiaoping YAN ; Xiaoyan QI ; Dengyan QIAO ; Weiping LIU ; Xiusan XIA ; Ling MENG ; Jinhua LIANG ; Ping SHEN ; Yonghong XIAO
Chinese Journal of Clinical Infectious Diseases 2024;17(1):42-57
Objective:To report the results of national surveillance on the distribution and antimicrobial resistance profile of clinical Gram-negative bacteria isolates from bloodstream infections in China in 2022.Methods:The clinical isolates of Gram-negative bacteria from blood cultures in member hospitals of national bloodstream infection Bacterial Resistant Investigation Collaborative System(BRICS)were collected during January 2022 to December 2022. Antibiotic susceptibility tests were conducted by agar dilution or broth dilution methods recommended by Clinical and Laboratory Standards Institute(CLSI). WHONET 5.6 and SPSS 25.0 software were used to analyze the data.Results:During the study period,9 035 strains of Gram-negative bacteria were collected from 51 hospitals,of which 7 895(87.4%)were Enterobacteriaceae and 1 140(12.6%)were non-fermenting bacteria. The top 5 bacterial species were Escherichia coli( n=4 510,49.9%), Klebsiella pneumoniae( n=2 340,25.9%), Pseudomonas aeruginosa( n=534,5.9%), Acinetobacter baumannii complex( n=405,4.5%)and Enterobacter cloacae( n=327,3.6%). The ESBLs-producing rates in Escherichia coli, Klebsiella pneumoniae and Proteus spp. were 47.1%(2 095/4 452),21.0%(427/2 033)and 41.1%(58/141),respectively. The prevalence of carbapenem-resistant Escherichia coli(CREC)and carbapenem-resistant Klebsiella pneumoniae(CRKP)were 1.3%(58/4 510)and 13.1%(307/2 340);62.1%(36/58)and 9.8%(30/307)of CREC and CRKP were resistant to ceftazidime/avibactam combination,respectively. The prevalence of carbapenem-resistant Acinetobacter baumannii(CRAB)complex was 59.5%(241/405),while less than 5% of Acinetobacter baumannii complex was resistant to tigecycline and polymyxin B. The prevalence of carbapenem-resistant Pseudomonas aeruginosa(CRPA)was 18.4%(98/534). There were differences in the composition ratio of Gram-negative bacteria in bloodstream infections and the prevalence of main Gram-negative bacteria resistance among different regions,with statistically significant differences in the prevalence of CRKP and CRPA( χ2=20.489 and 20.252, P<0.001). The prevalence of CREC,CRKP,CRPA,CRAB,ESBLs-producing Escherichia coli and Klebsiella pneumoniae were higher in provinicial hospitals than those in municipal hospitals( χ2=11.953,81.183,10.404,5.915,12.415 and 6.459, P<0.01 or <0.05),while the prevalence of CRPA was higher in economically developed regions(per capita GDP ≥ 92 059 Yuan)than that in economically less-developed regions(per capita GDP <92 059 Yuan)( χ2=6.240, P=0.012). Conclusions:The proportion of Gram-negative bacteria in bloodstream infections shows an increasing trend,and Escherichia coli is ranked in the top,while the trend of CRKP decreases continuously with time. Decreasing trends are noted in ESBLs-producing Escherichia coli and Klebsiella pneumoniae. Low prevalence of carbapenem resistance in Escherichia coli and high prevalence in CRAB complex have been observed. The composition ratio and antibacterial spectrum of bloodstream infections in different regions of China are slightly different,and the proportion of main drug resistant bacteria in provincial hospitals is higher than those in municipal hospitals.


Result Analysis
Print
Save
E-mail