1.Polysaccharide of Alocasia cucullata Exerts Antitumor Effect by Regulating Bcl-2, Caspase-3 and ERK1/2 Expressions during Long-Time Administration.
Qi-Chun ZHOU ; Shi-Lin XIAO ; Ru-Kun LIN ; Chan LI ; Zhi-Jie CHEN ; Yi-Fei CHEN ; Chao-Hua LUO ; Zhi-Xian MO ; Ying-Bo LIN
Chinese journal of integrative medicine 2024;30(1):52-61
OBJECTIVE:
To study the in vitro and in vivo antitumor effects of the polysaccharide of Alocasia cucullata (PAC) and the underlying mechanism.
METHODS:
B16F10 and 4T1 cells were cultured with PAC of 40 µg/mL, and PAC was withdrawn after 40 days of administration. The cell viability was detected by cell counting kit-8. The expression of Bcl-2 and Caspase-3 proteins were detected by Western blot and the expressions of ERK1/2 mRNA were detected by quantitative real-time polymerase chain reaction (qRT-PCR). A mouse melanoma model was established to study the effect of PAC during long-time administration. Mice were divided into 3 treatment groups: control group treated with saline water, positive control group (LNT group) treated with lentinan at 100 mg/(kg·d), and PAC group treated with PAC at 120 mg/(kg·d). The pathological changes of tumor tissues were observed by hematoxylin-eosin staining. The apoptosis of tumor tissues was detected by TUNEL staining. Bcl-2 and Caspase-3 protein expressions were detected by immunohistochemistry, and the expressions of ERK1/2, JNK1 and p38 mRNA were detected by qRT-PCR.
RESULTS:
In vitro, no strong inhibitory effects of PAC were found in various tumor cells after 48 or 72 h of administration. Interestingly however, after 40 days of cultivation under PAC, an inhibitory effect on B16F10 cells was found. Correspondingly, the long-time administration of PAC led to downregulation of Bcl-2 protein (P<0.05), up-regulation of Caspase-3 protein (P<0.05) and ERK1 mRNA (P<0.05) in B16F10 cells. The above results were verified by in vivo experiments. In addition, viability of B16F10 cells under long-time administration culture in vitro decreased after drug withdrawal, and similar results were also observed in 4T1 cells.
CONCLUSIONS
Long-time administration of PAC can significantly inhibit viability and promote apoptosis of tumor cells, and had obvious antitumor effect in tumor-bearing mice.
Mice
;
Animals
;
Alocasia/metabolism*
;
MAP Kinase Signaling System
;
Caspase 3/metabolism*
;
Apoptosis
;
RNA, Messenger/metabolism*
2.Longitudinal extrauterine growth restriction in extremely preterm infants: current status and prediction model
Xiaofang HUANG ; Qi FENG ; Shuaijun LI ; Xiuying TIAN ; Yong JI ; Ying ZHOU ; Bo TIAN ; Yuemei LI ; Wei GUO ; Shufen ZHAI ; Haiying HE ; Xia LIU ; Rongxiu ZHENG ; Shasha FAN ; Li MA ; Hongyun WANG ; Xiaoying WANG ; Shanyamei HUANG ; Jinyu LI ; Hua XIE ; Xiaoxiang LI ; Pingping ZHANG ; Hua MEI ; Yanju HU ; Ming YANG ; Lu CHEN ; Yajing LI ; Xiaohong GU ; Shengshun QUE ; Xiaoxian YAN ; Haijuan WANG ; Lixia SUN ; Liang ZHANG ; Jiuye GUO
Chinese Journal of Neonatology 2024;39(3):136-144
Objective:To study the current status of longitudinal extrauterine growth restriction (EUGR) in extremely preterm infants (EPIs) and to develop a prediction model based on clinical data from multiple NICUs.Methods:From January 2017 to December 2018, EPIs admitted to 32 NICUs in North China were retrospectively studied. Their general conditions, nutritional support, complications during hospitalization and weight changes were reviewed. Weight loss between birth and discharge > 1SD was defined as longitudinal EUGR. The EPIs were assigned into longitudinal EUGR group and non-EUGR group and their nutritional support and weight changes were compared. The EPIs were randomly assigned into the training dataset and the validation dataset with a ratio of 7∶3. Univariate Cox regression analysis and multiple regression analysis were used in the training dataset to select the independent predictive factors. The best-fitting Nomogram model predicting longitudinal EUGR was established based on Akaike Information Criterion. The model was evaluated for discrimination efficacy, calibration and clinical decision curve analysis.Results:A total of 436 EPIs were included in this study, with a mean gestational age of (26.9±0.9) weeks and a birth weight of (989±171) g. The incidence of longitudinal EUGR was 82.3%(359/436). Seven variables (birth weight Z-score, weight loss, weight growth velocity, the proportion of breast milk ≥75% within 3 d before discharge, invasive mechanical ventilation ≥7 d, maternal antenatal corticosteroids use and bronchopulmonary dysplasia) were selected to establish the prediction model. The area under the receiver operating characteristic curve of the training dataset and the validation dataset were 0.870 (95% CI 0.820-0.920) and 0.879 (95% CI 0.815-0.942), suggesting good discrimination efficacy. The calibration curve indicated a good fit of the model ( P>0.05). The decision curve analysis showed positive net benefits at all thresholds. Conclusions:Currently, EPIs have a high incidence of longitudinal EUGR. The prediction model is helpful for early identification and intervention for EPIs with higher risks of longitudinal EUGR. It is necessary to expand the sample size and conduct prospective studies to optimize and validate the prediction model in the future.
3.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
4.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
5.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
6.Effects of emodin modulation of the HIF-1α/VEGF pathway on vascular endothelial cells damage in diabetic macroangiopathy rats
Qiu-Xiao ZHU ; Hui-Yao HAO ; Zi-Bo LIU ; Ming GAO ; Fang ZHANG ; Jing ZHOU ; Zhi-Hua HAO ; Li-Hui ZHANG ; Yong-Mei HAO
The Chinese Journal of Clinical Pharmacology 2024;40(6):859-863
Objective To investigate the impact of emodin(EM)on vascular endothelial cell injury in rats with diabetes macroangiopathy by regulating hypoxia inducible factor-1α(HIF-1α)/vascular endothelial growth factor(VEGF)signaling pathway.Methods SD rats were divided into blank group and modeling group,the rats in the modeling group were fed with high fat and high sugar combined with N-nitro-L-arginine methyl ester to build the diabetes macroangiopathy model,and the blank group was fed with ordinary diet.The vascular endothelial cells successfully isolated from the thoracic aorta of rats in blank group and modeling group were named control group and model group,respectively.The vascular endothelial cells in the modeling group were divided into model group,dimethyloxallyl glycine(DMOG)group(10 μmol·L-1DMOG),combined group(80 mg·L-1EM+10 μmol·L-1 DMOG)and experimental-L,-M,-H groups(20,40,80 mg·L-1 EM).The apoptosis of rat vascular endothelial cells was detected by flow cytometry;Western blot was applied to detect the expression of HIF-1αand VEGF proteins in rat vascular endothelial cells.Results The apoptosis rates of vascular endothelial cells in experimental-M,-H groups,DMOG group,combined group,model group and control group were(10.18±0.36)%,(6.28±0.20)%,(24.96±1.18)%,(12.36±0.49)%,(18.76±0.68)%and(4.59±0.26)%;HIF-1α protein levels were 0.96±0.07,0.78±0.06,2.03±0.12,1.05±0.13,1.58±0.12 and 0.69±0.05;VEGF protein levels were 0.59±0.05,0.23±0.02,0.98±0.06,0.63±0.04,0.86±0.07 and 0.11±0.01.The above indexes in the model group were compared with the control,DMOG,experimental-M and experimental-H groups,and the above indexes in the combined group were compared with the experimental-H group,and the differences were statistically significant(all P<0.05).Conclusion EM may inhibit HIF-1α/VEGF pathway to improve vascular endothelial cell injury in rats with diabetes macroangiopathy.
7.Bioequivalence study of gliclazide sustained-release tablets in Chinese healthy subjects
Zhou-Ping DUAN ; Xiao-Wei ZHAO ; Jin-Hua WEN ; Shi-Bo HUANG ; Pu LI ; Duan-Wen CAO
The Chinese Journal of Clinical Pharmacology 2024;40(15):2241-2245
Objective To investigate the bioequivalence of gliclazide sustained-release tablets in Chinese healthy subjects.Methods The study was designed using a single-center,open,randomized,single-dose,two-cycle,two-sequence administration method;subjects were orally administered the test/reference preparation 30 mg on an fasting or fed conditions,with self-cross-dosing.The concentration of gliclazide in human plasma was determined by liquid chromatography tandem mass spectrometry(LC-MS/MS)method.The main pharmacokinetic parameters of gliclazide(Cmax,AUC0-t and AUC0-∞)were analyzed by non-atrioventricular model of WinNonlin.Result In the fasting study,24 subjects were recruited and 22 completed the study.The main pharmacokinetic parameters of gliclazide sustained-release tablets test preparation and reference preparation in the fasting group were as follows:Cmax were(862.48±294.48)and(902.96±259.09)ng·mL-1;AUC0-t were(2.60 × 104±8 930.46)and(2.50 ×104±7 573.42)h·ng-1·mL-1;AUC0-∞ were(3.00 × 104±1.43 × 104)and(2.68 × 104±7 085.99)h·ng·mL-1.In the fed study,twenty-four subjects were enrolled and 23 completed the study.The main pharmacokinetic parameters of gliclazide sustained-release tablets test preparation and reference preparation in fed group:Cmax were(1 531.74±273.49)and(1 510.87±241.08)ng·mL-1;AUC0-t were(2.78 ×104±9 565.89)and(2.76 ×104±9 821.43)h·ng·mL-1;AUC0-∞ were(3.02 ×104±1.24 ×104)and(3.02 × 104±1.30 × 104)h·ng·mL-1 h·ng·mL-1.The 90%confidence intervals of the geometric mean ratios of Cmax,AUC0-t,AUC0-∞ for the test preparation and reference preparation gliclazide sustained-release tablets were all between 80%and 125%.Conclusion The test and the reference preparation of gliclazide sustained-release tablets are bioequivalent in Chinese healthy subjects.
8.Reliability of a region-locked 3D-printed template combined with a bi-directional matching scheme to assist screw placement for thoracolumbar fractures
Wenxi ZHANG ; Jinhua ZHOU ; Hua ZHU ; Zhijun QIAO ; Bo LIU
Chinese Journal of Orthopaedic Trauma 2024;26(1):26-34
Objective:To evaluate the reliability of a region-locked 3D-printed template combined with a bi-directional matching scheme in assistance of screw placement for thoracolumbar fractures.Methods:From January 2019 to March 2023, 52 patients with thoracolumbar fracture were treated at Department of Orthopedics, The People's Hospital of Liyang. They were 29 males and 23 females, with an age of (58.2±13.3) years. They were divided into a template group and a free-hand group according to the different screw placements. In the template group of 25 cases, a region-locked 3D-printed template combined with a bi-directional matching scheme was used to assist the pedicle positioning; in the free-hand group of 27 cases, the free hand screw placement was assisted only by image data and C-arm fluoroscopy. The operation time, intraoperative fluoroscopy frequency, intraoperative blood loss, complications, and placement accuracy were compared between the 2 groups. Visual analogue scale (VAS), Oswestry disability index (ODI), and anterior height ratio of the injured vertebra were compared between preoperation, 1 week postoperation, and the final follow-up, as well as between the 2 groups.Results:There were no statistically significant differences in the preoperative general data between the 2 groups, showing comparability ( P>0.05). All patients were followed up for (11.2±4.2) months. The differences were not statistically significant between the 2 groups in intraoperative blood loss, rate of complications, VAS or ODI at preoperation, 1 week postoperation, or the final follow-up, or in anterior height ratio of the injured vertebra ( P>0.05). In the template group, the operation time [(80.1±18.5) min] was significantly longer than that in the free-hand group [(69.4±16.6) min], the intraoperative fluoroscopy frequency [2 (2, 3) times] significantly lower than that in the free-hand group [3 (3, 4) times], and the placement accuracy [98.4% (127/129)] significantly higher than that in the free-hand group [91.8% (112/122)] (all P<0.05). All patients showed significant improvements in VAS, ODI and anterior height ratio of the injured vertebra at postoperative 1 week compared with the preoperative values, and the improvements at the last follow-up were significantly larger than those at postoperative 1 week ( P<0.05). No injury to the spinal cord, nerve root or blood vessel was observed postoperatively. Conclusions:In the treatment of thoracolumbar fractures, the screw placement assisted by a region-locked 3D-printed template combined with a bi-directional matching scheme is better than free-hand screw placement in terms of improved accuracy and reduced fluoroscopy, but the former incurs longer operative exposure than the latter. There is no significant difference between the 2 methods of screw placement in clinical efficacy.
9.Antiviral Effect of Extracellular Matrix Protein ABI3BP on Vesicular Stomatitis Virus and Its Mechanism:A Preliminary Study In Vitro
Meng XIANG-BO ; Chen MEI-HUA ; Xu NUO ; Li TIAN-QI ; Li SHUAI-CHEN ; Zhou SUN-XIN ; Chen HUAN ; Zhang TONG
Chinese Medical Sciences Journal 2024;39(1):1-8,中插1
Objective To explore the influence of extracellular matrix protein ABI-interactor 3-binding protein(ABI3BP)on vesicular stomatitis virus(VSV)genome replication and innate immune signaling pathway. Methods The small interfering RNA(siRNA)was transfected to knock down ABI3BP gene in human skin fibroblast BJ-5ta cells.VSV-green fluorescent protein(VSV-GFP)-infected cell model was established.The morphological changes and F-actin stress fiber formation were detected on ABI3BP knockdown cells by phalloidin immunofluorescence staining.The mRNA level of virus replication was detected by RT-qPCR in BJ-5ta cells after VSV-GFP infection;western blotting was performed to detect the changes in interferon regulatory factor 3(IRF3)andTANK-binding kinase 1(TBK1)phosphorylation levels. Results The VSV-GFP-infected BJ-5ta cell model was successfully established.Efficient knockdown of ABI3BP in BJ-5ta cells was achieved.Phalloidin immunofluorescence staining revealed structural rearrangement of intracellular F-actin after ABI3BP gene knockdown.Compared with the control group,the gene copy number of VSV-GFP in ABI3BP knockdown cells increased by 2.2-3.5 times(P<0.01)and 2.2-4.0 times(P<0.01)respectively when infected with VSV of multiplicity of infection 0.1 and 1.The expression of viral protein significantly increased in ABI3BP knockdown cells after virus infection.The activation of type-Ⅰ interferon pathway,as determined by phosphorylated IRF3 and phosphorylated TBK1,was significantly decreased in ABI3BP knockdown cells after VSV-GFP infection. Conclusions Extracellular matrix protein ABI3BP plays an important role in maintaining the formation and rearrangement of actin structure.ABI3BP gene deletion promotes RNA virus replication,and ABI3BP is an important molecule that maintains the integrity of type Ⅰ interferon pathway.
10.The crosstalk of Wnt/β-catenin signaling and p53 in acute kidney injury and chronic kidney disease
Wen-Hua MING ; Lin WEN ; Wen-Juan HU ; Rong-Fang QIAO ; Yang ZHOU ; Bo-Wei SU ; Ya-Nan BAO ; Ping GAO ; Zhi-Lin LUAN
Kidney Research and Clinical Practice 2024;43(6):724-738
Wnt/β-catenin is a signaling pathway associated with embryonic development, organ formation, cancer, and fibrosis. Its activation can repair kidney damage during acute kidney injury (AKI) and accelerate the occurrence of renal fibrosis after chronic kidney disease (CKD). Interestingly, p53 has also been found as a key modulator in AKI and CKD in recent years. Meantime, some studies have found crosstalk between Wnt/β-catenin signaling pathways and p53, but more evidence is required on whether they have synergistic effects in renal disease progression. This article reviews the role and therapeutic targets of Wnt/β-catenin and p53 in AKI and CKD and proposes for the first time that Wnt/β-catenin and p53 have a synergistic effect in the treatment of renal injury.

Result Analysis
Print
Save
E-mail