1.Research on BP Neural Network Method for Identifying Cell Suspension Concentration Based on GHz Electrochemical Impedance Spectroscopy
An ZHANG ; A-Long TAO ; Qi-Hang RAN ; Xia-Yi LIU ; Zhi-Long WANG ; Bo SUN ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2025;52(5):1302-1312
		                        		
		                        			
		                        			ObjectiveThe rapid advancement of bioanalytical technologies has heightened the demand for high-throughput, label-free, and real-time cellular analysis. Electrochemical impedance spectroscopy (EIS) operating in the GHz frequency range (GHz-EIS) has emerged as a promising tool for characterizing cell suspensions due to its ability to rapidly and non-invasively capture the dielectric properties of cells and their microenvironment. Although GHz-EIS enables rapid and label-free detection of cell suspensions, significant challenges remain in interpreting GHz impedance data for complex samples, limiting the broader application of this technique in cellular research. To address these challenges, this study presents a novel method that integrates GHz-EIS with deep learning algorithms, aiming to improve the precision of cell suspension concentration identification and quantification. This method provides a more efficient and accurate solution for the analysis of GHz impedance data. MethodsThe proposed method comprises two key components: dielectric property dataset construction and backpropagation (BP) neural network modeling. Yeast cell suspensions at varying concentrations were prepared and separately introduced into a coaxial sensor for impedance measurement. The dielectric properties of these suspensions were extracted using a GHz-EIS dielectric property extraction method applied to the measured impedance data. A dielectric properties dataset incorporating concentration labels was subsequently established and divided into training and testing subsets. A BP neural network model employing specific activation functions (ReLU and Leaky ReLU) was then designed. The model was trained and tested using the constructed dataset, and optimal model parameters were obtained through this process. This BP neural network enables automated extraction and analytical processing of dielectric properties, facilitating precise recognition of cell suspension concentrations through data-driven training. ResultsThrough comparative analysis with conventional centrifugal methods, the recognized concentration values of cell suspensions showed high consistency, with relative errors consistently below 5%. Notably, high-concentration samples exhibited even smaller deviations, further validating the precision and reliability of the proposed methodology. To benchmark the recognition performance against different algorithms, two typical approaches—support vector machines (SVM) and K-nearest neighbor (KNN)—were selected for comparison. The proposed method demonstrated superior performance in quantifying cell concentrations. Specifically, the BP neural network achieved a mean absolute percentage error (MAPE) of 2.06% and an R² value of 0.997 across the entire concentration range, demonstrating both high predictive accuracy and excellent model fit. ConclusionThis study demonstrates that the proposed method enables accurate and rapid determination of unknown sample concentrations. By combining GHz-EIS with BP neural network algorithms, efficient identification of cell concentrations is achieved, laying the foundation for the development of a convenient online cell analysis platform and showing significant application prospects. Compared to typical recognition approaches, the proposed method exhibits superior capabilities in recognizing cell suspension concentrations. Furthermore, this methodology not only accelerates research in cell biology and precision medicine but also paves the way for future EIS biosensors capable of intelligent, adaptive analysis in dynamic biological research. 
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
7.No Incidence of Liver Cancer Was Observed in A Retrospective Study of Patients with Aristolochic Acid Nephropathy.
Tao SU ; Zhi-E FANG ; Yu-Ming GUO ; Chun-Yu WANG ; Jia-Bo WANG ; Dong JI ; Zhao-Fang BAI ; Li YANG ; Xiao-He XIAO
Chinese journal of integrative medicine 2024;30(2):99-106
		                        		
		                        			OBJECTIVE:
		                        			To assess the risk of aristolochic acid (AA)-associated cancer in patients with AA nephropathy (AAN).
		                        		
		                        			METHODS:
		                        			A retrospective study was conducted on patients diagnosed with AAN at Peking University First Hospital from January 1997 to December 2014. Long-term surveillance and follow-up data were analyzed to investigate the influence of different factors on the prevalence of cancer. The primary endpoint was the incidence of liver cancer, and the secondary endpoint was the incidence of urinary cancer during 1 year after taking AA-containing medication to 2014.
		                        		
		                        			RESULTS:
		                        			A total of 337 patients diagnosed with AAN were included in this study. From the initiation of taking AA to the termination of follow-up, 39 patients were diagnosed with cancer. No cases of liver cancer were observed throughout the entire follow-up period, with urinary cancer being the predominant type (34/39, 87.17%). Logistic regression analysis showed that age, follow-up period, and diabetes were potential risk factors, however, the dosage of the drug was not significantly associated with urinary cancer.
		                        		
		                        			CONCLUSIONS
		                        			No cases of liver cancer were observed at the end of follow-up. However, a high prevalence of urinary cancer was observed in AAN patients. Establishing a direct causality between AA and HCC is challenging.
		                        		
		                        		
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Retrospective Studies
		                        			;
		                        		
		                        			Incidence
		                        			;
		                        		
		                        			Carcinoma, Hepatocellular
		                        			;
		                        		
		                        			Liver Neoplasms/epidemiology*
		                        			;
		                        		
		                        			Kidney Diseases/chemically induced*
		                        			;
		                        		
		                        			Aristolochic Acids/adverse effects*
		                        			
		                        		
		                        	
8.An experimental study of a novel external fixator based on universal joints for the rapid initial stabilization of mandibular comminuted fractures
Zhi-Qiang HU ; Tai-Qiang DAI ; Lu ZHAO ; Xun LI ; Xu GONG ; Hao JIA ; Hai-Tao KONG ; Bo-Lei CAI ; Shi-Ping CHANG ; Lei TIAN
Chinese Journal of Traumatology 2024;27(5):254-262
		                        		
		                        			
		                        			Purpose::Shaping and assembling contemporary external fixators rapidly for the severe mandibular fractures remains a challenge, especially in emergency circumstance. We designed a novel external fixator that incorporates universal joints to provide the stabilization for mandibular comminuted fractures. This study aims to confirm the efficacy of this novel external fixator through biomechanical tests in vitro and animal experiments. Methods::In vitro biomechanical tests were conducted using 6 fresh canine with mandibular defect to simulate critical comminuted fractures. Three mandibles were stabilized by the novel external fixator and other mandibles were fixed by 2.5 mm reconstruction plates. All fixed mandibles were subjected to loads of 350 N on the anterior regions of teeth and 550 N on the first molar of the unaffected side. The stability was evaluated based on the maximum displacement and the slope of the load-displacement curve. In animal experiments, 9 beagles with comminuted mandibular fractures were divided into 3 groups, which were treated with the novel external fixation, reconstruction plate, and dental arch bar, respectively. The general observation, the changes in animals’ weight, and the surgical duration were recorded and compared among 3 groups. The CT scans were performed at various intervals of 0 day (immediately after the surgery), 3 days, 7 days, 14 days, 21 days, and 28 days to analyze the displacement of feature points on the canine mandible and situation of fracture healing at 28 days. The statistical significance was assessed by the two-way analysis of variance test followed by the Bonferroni test, enabling multiple comparisons for all tests using GraphPad Prism10.1.0 (GraphPad Inc, USA). Results::The outcomes of the biomechanical tests indicated that no statistically significant differences were found in terms of the maximum displacement ( p = 0.496, 0.079) and the slope of load displacement curves ( p = 0.374, 0.349) under 2 load modes between the external and internal fixation groups. The animal experiment data showed that there were minor displacements of feature points between the external and internal fixation groups without statistic difference, while the arch bar group demonstrated inferior stability. The CT analysis revealed that the best fracture healing happened in the internal fixation group, followed by the external fixation and arch baring at 28 days after fixation. The external fixation group had the shortest fixation duration (25.67 ± 3.79) min compared to internal fixation ((70.67 ± 4.51) min, p < 0.001) and arch baring ((42.00 ± 3.00) min, p = 0.046). Conclusion::The conclusion of this study highlighted the efficacy and reliability of this novel external fixator in managing mandibular fractures rapidly, offering a viable option for the initial stabilization of comminuted mandibular fractures in the setting of emergency rescue.
		                        		
		                        		
		                        		
		                        	
9.IgA nephropathy with mesangial type Ⅲ collagen deposition:2 cases report
Jie-Bo HUANG ; Xiao-Fan CAI ; Zhong-Hua ZHAO ; Zhi-Gang ZHANG ; Qiang SHEN ; Hao WANG ; Hui-Juan WU
Fudan University Journal of Medical Sciences 2024;51(3):426-430
		                        		
		                        			
		                        			As interstitial collagen,type Ⅲ collagen(Col Ⅲ)does not express in normal glomeruli.However,in Col Ⅲ nephropathy,a large amount of Col Ⅲ deposit in the mesangial and subendothelial area of the glomeruli.IgA nephropathy with Col Ⅲ deposition was extremely rare.In this article,we reported two cases of such disease.After treating with immunosuppressive agents or traditional Chinese medicine decoction,the renal function of the two patients remained stable and the urinary protein levels reduced significantly.
		                        		
		                        		
		                        		
		                        	
10.Preliminary study on delaying aging induced thymus degeneration in SAMP6 mice with Bazi Bushen capsule
Zhao-Dong LI ; Yin-Xiao CHEN ; Bo-Yang GONG ; Zhe XU ; Zhi-Xian YU ; Yue-Xuan SHI ; Yan-Fei PENG ; Yu-Hong BIAN ; Yun-Long HOU ; Xiang-Ling WANG ; Shu-Wu ZHAO
Chinese Pharmacological Bulletin 2024;40(6):1186-1192
		                        		
		                        			
		                        			Aim To explore the improvement effect of Bazi Bushen capsule on thymic degeneration in SAMP6 mice and the possible mechanism.Methods Twenty 12 week old male SAMP6 mice were randomly divided into the model group(SAMP6)and the Bazi Busheng capsule treatment group(SAMP6+BZBS).Ten SAMR1 mice were assigned to a homologous control group(SAMR1).The SAMP6+BZBS group was oral-ly administered Bazi Bushen capsule suspension(2.8 g·kg-1)daily,while the other two groups were orally administered an equal amount of distilled water.After nine weeks of administration,the morphology of the thymus in each group was observed and the thymus in-dex was calculated;HE staining was used to observe the structural changes of thymus tissue;SA-β-gal stai-ning was used to detect thymic aging;flow cytometry was used to detect the proportion of thymic CD3+T cells in each group;Western blot was used to detect the levels of p16,Bax,Bcl-2,and cleaved caspase-3 proteins in thymus;immunofluorescence was applied to detect the proportion of cortical thymic epithelial cells in each group;ELISA was employed to detect IL-7 lev-els in thymus.Results Compared with the SAMP6 group,the thymic index of the SAMP6+BZBS group significantly increased(P<0.05);the disordered thy-mic structure was significantly improved;the positive proportion of SA-β-gal staining significantly decreased(P<0.01);the proportion of CD3+T cells apparently increased(P<0.05);the level of p16 protein signifi-cantly decreased(P<0.05);the level of Bcl-2 pro-tein significantly increased(P<0.05),while the lev-el of cleaved caspase-3 protein markedly decreased(P<0.05);the proportion of cortical thymic epithelial cells evidently increased;the level of IL-7 significantly increased(P<0.01).Conclusions Bazi Bushen capsule can delay thymic degeneration,inhibit cell ap-optosis in thymus and promote thymic cell development in SAMP6 mice,which may be related to increasing the proportion of cortical thymic epithelial cells and promoting IL-7 secretion.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail