1.Two Cases of Pancreatobiliary Disease Complications Treated Using Over-the-Scope Clip
Byung Soo KWAN ; Bo Ram SUNG ; Kwang Min KIM
Korean Journal of Pancreas and Biliary Tract 2025;30(1):26-30
The over-the-scope clip (OTSC) system is a powerful full-thickness suturing device used for closing refractory bleeding, perforations, and fistulas in gastrointestinal diseases, offering greater force than conventional clips. Here, we report two cases of pancreatobiliary disease treated using OTSC. The first case involved the successful OTSC ligation of a colonic fistula caused by necrotizing pancreatitis, and the second was a duodenal perforation due to stent migration, which was also successfully treated with OTSC. These cases indicate that OTSC can be beneficial for pancreatobiliary diseases, potentially eliminating the need for surgery when endoscopic treatment is successful.
2.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
3.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
4.Features of Lung Cyst in Birt-Hogg-Dubé Syndrome from Patients with Multiple Lung Cysts
Yong Jun CHOI ; Hye Jung PARK ; Chi Young KIM ; Bo Mi JUNG ; Jae Hwa CHO ; Min Kwang BYUN
Tuberculosis and Respiratory Diseases 2025;88(2):388-398
Background:
High-resolution chest computed tomography (CT) is a crucial assessment tool for diagnosing Birt-Hogg-Dubé (BHD) syndrome. This study aimed to analyze differences of lung cysts between BHD and other cystic lung diseases.
Methods:
From January 2020 to December 2022, patients with multiple lung cysts who underwent chest CT at Gangnam Severance Hospital were included.
Results:
Over a 3-year period (from January 2020 to December 2022), out of 52,823 patients who underwent a chest CT scan, 301 (0.6%) patients with multiple lung cysts were enrolled in this study. Of enrolled patients, 24 (8.0%) were diagnosed with BHD. In patients with BHD, 95.8% exhibited bilateral cysts, and 83.3% showed basal predominance. The cysts’ maximal diameter averaged 32.1 mm (interquartile range, 26.5 to 43.5). Additionally, 95.8% of patients with BHD had diverse cyst sizes and morphologies. Multivariate logistic regression analysis revealed that bilateral cysts (odds ratio [OR], 12.393; 95% confidence interval [CI], 1.613 to 274.682; p=0.038), basal predominance (OR, 8.511; 95% CI, 2.252 to 39.392; p=0.002), maximum diameter (OR, 1.053; 95% CI, 1.009 to 1.108; p=0.032), and diversity of morphology (OR, 19.513; 95% CI, 2.833 to 398.119; p=0.010) were significant factors associated with BHD diagnosis. A multivariate prediction model for BHD diagnosis demonstrated a sensitivity of 95.83%, a specificity of 81.22%, and an area under the receiver operating characteristic curve of 0.951 (95% CI, 0.914 to 0.987).
Conclusion
Distinguishing features of lung cysts from other cystic lung diseases include bilateral cysts, basal dominance, large size, and irregular shape.
5.Development of a Long-Acting Follicle-Stimulating Hormone Using Serum Albumin Fab-Associated Technology for Female Infertility
Daham KIM ; Yoon Hee CHO ; Min Jeong KANG ; So Jeong LEE ; Soohyun LEE ; Bo Hyon YUN ; Hyunjin CHI ; Jeongsuk AN ; Kyungsun LEE ; Jaekyu HAN ; Susan CHI ; Moo Young SONG ; Sang-Hoon CHA ; Eun Jig LEE
Endocrinology and Metabolism 2025;40(1):146-155
Background:
Recombinant human follicle-stimulating hormone (rhFSH) is commonly used to treat female infertility, but its short half-life necessitates multiple doses. Even corifollitropin alfa, with an extended half-life, requires supplementary injections of rhFSH after 7 days. This study aimed to develop and evaluate a long-acting follicle-stimulating hormone (FSH) formulation using anti-serum albumin Fab-associated (SAFA) technology to avoid additional injections and enhance ovarian function.
Methods:
SAFA-FSH was synthesized using a Chinese hamster ovary expression system. Its biological efficacy was confirmed through assays measuring its ability to stimulate cyclic adenosine monophosphate (cAMP) production, estradiol synthesis, and the expression of human cytochrome P450 family 19 subfamily A member 1 (hCYP19α1) and human steroidogenic acute regulatory protein (hSTAR) in human ovarian granulosa (KGN) cells. To evaluate the effects of SAFA-FSH, we compared its impact on serum estradiol levels and ovarian weight increase with that of rhFSH in Sprague-Dawley (SD) rats using the modified Steelman-Pohley test.
Results:
The results indicated that SAFA-FSH induces cAMP synthesis in KGN cells and upregulates the expression of hCYP19α1 and hSTAR in a dose-dependent manner. Female SD rats, aged 21 days, receiving daily subcutaneous human chorionic gonadotropin injections for 5 days exhibited a significant increase in serum estradiol levels and ovarian weight when administered SAFA-FSH on the first day or when given nine injections of rhFSH over 5 days. Notably, the group receiving SAFA-FSH on the first and third days demonstrated an even greater rise in serum estradiol levels and ovarian weight.
Conclusion
These findings suggest that SAFA-FSH presents a promising alternative to current rhFSH treatments for female infertility. However, further research is essential to thoroughly assess its safety and efficacy in clinical contexts.
6.A practical guide for enteral nutrition from the Korean Society for Parenteral and Enteral Nutrition: Part I. prescribing enteral nutrition orders
Ye Rim CHANG ; Bo-Eun KIM ; In Seok LEE ; Youn Soo CHO ; Sung-Sik HAN ; Eunjung KIM ; Hyunjung KIM ; Jae Hak KIM ; Jeong Wook KIM ; Sung Shin KIM ; Eunhee KONG ; Ja Kyung MIN ; Chi-Min PARK ; Jeongyun PARK ; Seungwan RYU ; Kyung Won SEO ; Jung Mi SONG ; Minji SEOK ; Eun-Mi SEOL ; Jinhee YOON ; Jeong Meen SEO ;
Annals of Clinical Nutrition and Metabolism 2025;17(1):3-8
Purpose:
This study aimed to develop a comprehensive practical guide for enteral nutrition (EN) designed to enhance patient safety and reduce complications in Korea. Under the leadership of the Korean Society for Parenteral and Enteral Nutrition (KSPEN), the initiative sought to standardize EN procedures, improve decision-making, and promote effective multidisciplinary communication.
Methods:
The KSPEN EN committee identified key questions related to EN practices and organized them into seven sections such as prescribing, delivery route selection, formula preparation, administration, and quality management. Twenty-one experts, selected based on their expertise, conducted a thorough literature review to formulate evidence-based recommendations. Drafts underwent peer review both within and across disciplines, with final revisions completed by the KSPEN Guideline Committee. The guide, which will be published in three installments, addresses critical elements of EN therapy and safety protocols.
Results:
The practical guide recommends that EN orders include detailed elements and advocates the use of electronic medical records for communication. Standardized prescription forms and supplementary safety measures are outlined. Review frequency is adjusted according to patient condition—daily for critically ill or unstable patients and as dictated by institutional protocols for stable patients. Evidence indicates that adherence to these protocols reduces mortality, complications, and prescription errors.
Conclusion
The KSPEN practical guide offers a robust framework for the safe delivery of EN tailored to Korea’s healthcare context. It emphasizes standardized protocols and interdisciplinary collaboration to improve nutritional outcomes, patient safety, and operational efficiency. Rigorous implementation and monitoring of adherence are critical for its success.
7.Effect of Nationwide Postoperative Rehabilitation at Home Program after Lower Extremity Surgeries in Older and Younger People
Kyunghoon MIN ; Sangchul LEE ; Jae Min KIM ; Jung Hyun PARK ; Jun Hwan CHOI ; Bo Ryun KIM ; Kyu Wan KWAK ; Seong Jun KIM ; Jae-Young LIM
Annals of Geriatric Medicine and Research 2025;29(1):119-130
Background:
A nationwide Rehabilitation at Home Care Pilot Program for patients undergoing lower extremity orthopedic surgeries has been ongoing since 2020. The program was designed to improve clinical outcomes through early mobilization and rehabilitation after discharge. This study aimed to analyze the interim data to assess its effectiveness and suggest improvements, particularly for older patients who are more vulnerable compared to younger patients.
Methods:
We analyzed the data of 872 patients from seven hospitals. Patients were divided into an older-age group (OG; ≥60 years) and younger-age group (YG; <60 years). The Berg Balance Scale (BBS) and Numeric Rating Scale (NRS) scores for pain were the main outcomes.
Results:
Participants were categorized into OG (n=801) and YG (n=71). The most common surgeries were knee joint replacement (63.7%) in OG and hip joint replacement in YG (77.5%). It took more days to enroll in the pilot program in OG (4.4 days) than YG (3.2 days). OG showed less improvement in BBS than YG for all surgeries (23.3 vs. 31.9) and hip joint surgery (19.8 vs. 33.5). In patients with hip joint replacement in OG, those with a higher number of comorbidities (≥3) showed less BBS improvement than those with fewer comorbidities (<3). In the pain domain, NRS scores decreased in both groups.
Conclusion
The postoperative rehabilitation education program appeared to be effective in improving physical function and reducing pain severity, though the improvement was less obvious in older patients who may require a more comprehensive approach compared to younger patients.
8.Two Cases of Pancreatobiliary Disease Complications Treated Using Over-the-Scope Clip
Byung Soo KWAN ; Bo Ram SUNG ; Kwang Min KIM
Korean Journal of Pancreas and Biliary Tract 2025;30(1):26-30
The over-the-scope clip (OTSC) system is a powerful full-thickness suturing device used for closing refractory bleeding, perforations, and fistulas in gastrointestinal diseases, offering greater force than conventional clips. Here, we report two cases of pancreatobiliary disease treated using OTSC. The first case involved the successful OTSC ligation of a colonic fistula caused by necrotizing pancreatitis, and the second was a duodenal perforation due to stent migration, which was also successfully treated with OTSC. These cases indicate that OTSC can be beneficial for pancreatobiliary diseases, potentially eliminating the need for surgery when endoscopic treatment is successful.
9.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
10.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.

Result Analysis
Print
Save
E-mail