1.Effects of Peripheral Blood Different Pretreatment Methods and Preservation Time on RNA Quality.
Jia-Yi ZHANG ; Qian-Nan XU ; Xi-Ling LIU ; Cheng-Tao LI
Journal of Forensic Medicine 2021;37(6):825-831
OBJECTIVES:
To evaluate the effects of different pretreatment methods and preservation time on RNA quality of peripheral blood samples, and to optimize the preservation method of peripheral blood samples.
METHODS:
Eight pretreatment methods were used to preprocess the peripheral blood from 3 healthy unrelated individuals and the treated samples were stored at -80 ℃. Total RNA of samples was extracted using Quick-RNATM Miniprep Plus kit. DNA/RNA ShieldTM was added to peripheral blood and total RNA was extracted after preservation at -80 ℃ for 0, 5, 10, 15, 30 and 60 days, respectively. The concentration, purity and integrity of RNA were determined. Statistical analyses were performed by SPSS 22.0 software to compare the differences in RNA yield, purity and integrity among the eight pretreatment methods.
RESULTS:
In terms of purity, leukocyte pretreated with RNAlaterTM and directly cryopreservation peripheral blood showed the worst purity. The other six methods showed better purity. In terms of yield, blood cells with DNA/RNA ShieldTM came out with the highest yield, followed by peripheral blood with DNA/RNA ShieldTM. In terms of integrity, peripheral blood preserved in PAXgene Blood RNA tube method had the best integrity. Except for peripheral blood pretreated with DNA/RNA ShieldTM and blood cells pretreated with DNA/RNA shieldTM, the other five methods had statistical differences when compared to the method by keeping peripheral blood in PAXgene Blood RNA tube. The purity of RNA stored at six-time gradients ranged from 1.815 to 1.952. With the increase of storage time, RNA yield decreased from 4.516 ng to 1.039 ng, and RNA integrity decreased from 8.533 to 7.150.
CONCLUSIONS
According to the results of total RNA's yield, purity and integrity, peripheral blood pretreated with DNA/RNA ShieldTM was the best pretreatment method. After the pretreatment, samples can be preserved for up to 60 days in low temperature.
Blood Specimen Collection/methods*
;
Cryopreservation
;
DNA/analysis*
;
Humans
;
RNA
2.Adrenocorticotropic Hormone-Secreting Esthesioneuroblastoma with Ectopic Cushing's Syndrome
Young Soo CHUNG ; Minkyun NA ; Cheol Ryong KU ; Se Hoon KIM ; Eui Hyun KIM
Yonsei Medical Journal 2020;61(3):257-261
Esthesioneuroblastoma as a source of ectopic Cushing's syndrome is rare, and to the best of our knowledge, only 20 cases have been reported worldwide. A 46-year-old healthy man visited a local clinic for general weakness and hyposmia, and underwent examination with serial endocrinological workup and brain imaging. ⁶⁸Gallium-DOTA-TOC positron emission tomography scan was helpful where diagnosis of sellar MRI and inferior petrosal sinus sampling were discordant. Combined transcranial and endoscopic endonasal approach surgery was performed, and a diagnosis of esthesioneuroblastoma was given.
Cushing Syndrome
;
Diagnosis
;
Esthesioneuroblastoma, Olfactory
;
Humans
;
Magnetic Resonance Imaging
;
Middle Aged
;
Neuroimaging
;
Petrosal Sinus Sampling
;
Positron-Emission Tomography
3.Surface judgments, profound questions: A homosexual male's Phlebotomy experience
Chadwick Co Sy Su ; Paul Martin Anthony C. Cenizal ; Teresita E. Dumagay
Philippine Journal of Health Research and Development 2019;23(4):12-17
Background and Objectives:
Two of the authors, one heterosexual and one homosexual, both voluntarily donated blood to a well-known health institution in the Philippines. As they were filling out the paperwork, one of the authors' attention was called by one of the questions in the form: “Nakipagtalik ka na ba sa iyong kauri?,” which can be literally translated as “Have you had sex with your own kind?”. This erroneously phrased
question was the sole question interrogated and problematized in the study.
Methodology:
Reviews of Standpoint Theory and the methodology associated with it and, in effect, used in the
study, formed part of the critique, divided into individual narrations and interpretations by each author. A third co-author, a hematologist, lent her insight on the logistics and issues of phlebotomy. Institutional ethnography was brought to bear on the narratives
Results and Conclusion
This three-author collaboration is presented as a claim that an interdisciplinary approach may open new vistas to a phenomenon that has long existed but been ignored. Reviews of Standpoint Theory and curriculum planning for health professionals are recommended.
Phlebotomy
;
Communication
;
Homosexuality
;
Blood Donation
4.Pediatric Deaths and Venipuncture
Taek CHUNG ; Sohyung PARK ; Hye Jeong KIM ; Kyoungmoo YANG ; Hongil HA
Korean Journal of Legal Medicine 2018;42(1):1-7
Venipuncture is a routine and relatively safe and painless medical procedure, necessary for accurate diagnosis and treatment. However, given that pain related to medical procedures may have adverse effects for children, could venipuncture cause deaths in infants and children? We analyzed our cases of unexpected death after venipuncture and conducted a literature review on them. A vasovagal response to noxious stimuli may explain such a sudden death immediately after venipuncture, commonly presented as needle phobia, breath-holding spell, and reflex anoxic seizure in the literature, despite the fact that the current medical evidence is not enough to prove their casual relationship. In addition, pain prevention and management during medical procedure is incorporated in clinical guidelines for pediatric patients, because painful medical procedures negatively affect child development. Thus, prevention and management of pain related to medical procedure may be helpful to avoid an adverse vasovagal response to noxious stimuli from occurring.
Autopsy
;
Child
;
Child Development
;
Death, Sudden
;
Diagnosis
;
Forensic Pathology
;
Humans
;
Infant
;
Infant Death
;
Needles
;
Phlebotomy
;
Phobic Disorders
;
Reflex
;
Seizures
5.Assessment of the Influence of Application Time of Lidocaine Patch on Pain Intensity after Venipuncture.
Journal of Korean Academy of Fundamental Nursing 2018;25(4):250-258
PURPOSE: This study was done to assess the influence of application time of Lidocaine patch on pain intensity following venipuncture in hospital. METHODS: The participants were 31 adult patients admitted to J hospital in G city. Patients' anxiety, blood pressure and pulse were measured when no patch was applied and when a patch was applied. To evaluate the pain intensity and physiological index caused by venipuncture, blood pressure, pulse and pain intensity were checked for patients in the no patch group, and for a 5 minutes of application and 30 minutes application patch. Pain was evaluated using a visual analogue scale, anxiety using the Profile of Mood states developed McNair et al. and modified by Lee. Data were analyzed using one-way repeated measures ANOVA with the SPSS 21.0 program. RESULTS: Anxiety and pain were significantly reduced when a lidocaine patch was applied following venipuncture. There was no significant difference in pain intensity whether the lidocaine patch application is for 30 minutes or application for 5 minutes. CONCLUSION: Results of this study show that application of lidocaine patch can be used as a nursing intervention for pain reduction by showing that there is no need to wait a long time for pain to be reduced.
Adult
;
Anxiety
;
Blood Pressure
;
Humans
;
Lidocaine*
;
Nursing
;
Phlebotomy*
6.Reducing the Reporting Time by Improving Laboratory Processing for Inpatient Routine Chemistry Tests.
Eun Jung CHO ; Kyoung Jin PARK ; Dae Hyun KO ; Hoon HONG ; Woochang LEE ; Sail CHUN ; Won Ki MIN
Laboratory Medicine Online 2018;8(2):52-55
BACKGROUND: The returning time of inpatient specimen analysis is usually slow because phlebotomists deliver all the collected specimens at the end of their work cycle. In addition, manual specimen reception further delays the reporting time and imposes a heavy workload on the technical staff, thus compromising effectiveness. Therefore, we have created an automated specimen reception system to tackle testing delays and enhance the efficiency and quality of specimen collection and handling. METHODS: In May 2015, the pre-analytical processing of inpatient samples was renovated. We automated the specimen reception in parallel with barcode printing and introduced pneumatic tubes to deliver samples for routine chemistry tests. We compared the reporting time of the automated system with that of the manual system and analyzed the distribution pattern of the specimens according to handling time. RESULTS: The median reporting time was advanced by 41 minutes, from 09:33 AM to 08:52 AM for the manual and automated reception, respectively. Moreover, with the reduction in hands-on time, the blood specimens reached the laboratory immediately after phlebotomy, thereby improving the processing efficiency by spreading out the interval during which the specimens arrived in the laboratory. Additionally, the new system allowed the identification of the phlebotomist who collected the specimens and tracking the specimens from collection to test result. CONCLUSIONS: With the introduction of our automatic reception system, the reporting time was considerably reduced. Therefore, the satisfaction of the clinician and the technical staff was improved.
Chemistry*
;
Humans
;
Inpatients*
;
Phlebotomy
;
Specimen Handling
7.Sudden unexpected cardio-respiratory arrest after venipuncture in children.
Goun JEONG ; Son Moon SHIN ; Nam Su KIM ; Young Min AHN
Korean Journal of Pediatrics 2018;61(4):108-113
PURPOSE: This study aimed to investigate the clinical and socioenvironmental characteristics of sudden cardiorespiratory arrest after venipuncture in children. METHODS: We conducted a retrospective email-based survey of all members of the Korean Pediatric Society. The questionnaire included items on patient demographics, socioenvironmental circumstances of the venipuncture, type of cardiorespiratory arrest, symptoms and signs, treatment, prognosis, and presumed cause of the arrest. RESULTS: Fourteen patients were identified. Of these, 13 were young children (< 2 years old), and 1 was 14 years old. All patients had been previously healthy and had no specific risk factors for sudden cardiorespiratory arrest. Most cases (n=11, 79%) were defined as cardiac or cardiorespiratory arrest, while the remaining cases (n=3, 21%) were defined as respiratory arrest. Aspiration (n=3), acute myocarditis (n=2), and laryngeal chemoreflex (n=1) were presumed as the causes; however, the exact causes were unclear. The overall prognosis was poor (death, n=7; morbidity, n=5; full recovery, n=2). The medical institutions faced severe backlash because of these incidents (out-of-court settlement, n=5; medical lawsuit, n=5; continuous harassment, n=3). CONCLUSION: Cardiorespiratory arrest after venipuncture is unpredictable and the probable cause of most cases is a vasovagal reaction. Medical personnel must be aware of the risk of unexpected cardiorespiratory arrest during routine intravenous procedures.
Cardiopulmonary Resuscitation
;
Child*
;
Demography
;
Heart Arrest
;
Humans
;
Myocarditis
;
Phlebotomy*
;
Prognosis
;
Retrospective Studies
;
Risk Factors
8.Role of fetal ultrasound in prenatally diagnosed de novo balanced translocations.
Eui Sun SEONG ; Hye Jin YOUN ; Min Kyung PARK ; Hye Yeon BOO ; Bom Yi LEE ; Hyun Mee RYU ; You Jung HAN
Journal of Genetic Medicine 2018;15(1):8-12
PURPOSE: This study aimed to investigate fetal ultrasonographic findings in cases of prenatally diagnosed de novo balanced translocations and the role of fetal ultrasound in prenatal genetic counseling. MATERIALS AND METHODS: We collected cases with de novo balanced translocations that were confirmed in chorionic villus sampling, amniocentesis, and cordocentesis between 1995 and 2016. A detailed, high-resolution ultrasonography was performed for prediction of prognosis. Chromosomes from the parents of affected fetuses were also analyzed to determine whether the balanced translocations were de novo or inherited. RESULTS: Among 32,070 cases with prenatal cytogenetic analysis, 27 cases (1/1,188 incidence) with de novo balanced translocations were identified. Fourteen cases (51.9%) showed abnormal findings, and the frequency of major structural anomalies was 11.1%. Excluding the major structural anomalies, all mothers who continued pregnancies delivered healthy babies. CONCLUSION: Results of a detailed, high-resolution ultrasound examination are very important in genetic counseling for prenatally diagnosed de novo balanced translocations.
Amniocentesis
;
Chorionic Villi Sampling
;
Cordocentesis
;
Cytogenetic Analysis
;
Female
;
Fetus
;
Genetic Counseling
;
Humans
;
Mothers
;
Parents
;
Pregnancy
;
Prenatal Diagnosis
;
Prognosis
;
Translocation, Genetic
;
Ultrasonography*
;
Ultrasonography, Prenatal
9.Two Small Intravenous Catheters for High-Rate Contrast Medium Injection for Computed Tomography in Patients Lacking Superficial Veins to Accommodate a Large Catheter.
Bum Gu SON ; Min Jung KIM ; Myeung Hwa PARK ; Kyoungsook KIM ; Jiyu KIM ; Se Young KIM ; Kyung Jin LEE ; Sang Hyun CHOI ; Ah Young KIM ; Seong Ho PARK
Korean Journal of Radiology 2018;19(3):489-497
OBJECTIVE: To prospectively investigate the feasibility of using 2 small intravenous catheters for high-rate computed tomography (CT) contrast injection in patients lacking superficial veins capable of accommodating ≤ 20-gauge catheters. MATERIALS AND METHODS: Sixty-eight consecutive eligible adults referred for dynamic liver CT were enrolled; 58 had previously undergone liver CT, including 8 that experienced extravasation. Two 22- or 24-gauge catheters were placed in all patients after 2–5 venipunctures, and 2 mL/kg of contrast agent (370 mg I/mL) was split-administered through both catheters to achieve total flow rate of 4 mL/s. Patients' experience and examination success rate, defined as uneventful scans completed at 4 mL/s or at < 4 mL/s achieving standard image quality in all phases, were analyzed. Quantitative hepatic signal-to-noise and hepatic vascular contrast-to-noise ratios (CNRs) were compared with 30 control examinations scanned at 4 mL/s using an 18-gauge catheter. RESULTS: One case each of extravasation and severe injection pain caused the examination to be aborted. Success rate was 88.2% (60/68; 54 patients scanned at 4 mL/s, 6 at 3.5–3.9 mL/s). Fifty-five of 58 patients (94.8%) that had past CT regarded the venipuncture as more tolerable than (n = 36) or similar to (n = 19) past experiences; 45 of 58 patients (77.6%) found contrast injection less painful than (n = 35) or similar to (n = 10) past experiences. When compared with control examinations, signal-to-noise ratio was similar in all phases (p ≥ 0.502), but the hepatic arterial CNR in arterial phase was slightly inferior (p ≤ 0.047). CONCLUSION: Using 2 small intravenous catheters can effectively achieve high-rate CT contrast injection in patients lacking adequate superficial veins.
Adult
;
Catheters*
;
Contrast Media
;
Humans
;
Liver
;
Multidetector Computed Tomography
;
Patient Satisfaction
;
Phlebotomy
;
Prospective Studies
;
Quality Assurance, Health Care
;
Signal-To-Noise Ratio
;
Veins*
10.Minimum Specimen Volume Analysis of ABO/RhD Typing and Unexpected Antibody Screening Using an Automated Immunohematology System DAYmate S.
Tae Yeul KIM ; Dong Woo SHIN ; Byeong Hui SON ; Ji Sang KANG ; Yousun CHUNG ; Dae Hyun KO ; Yun Ji HONG ; Hyungsuk KIM ; Kyoung Un PARK ; Kyou Sup HAN
Korean Journal of Blood Transfusion 2018;29(2):159-170
BACKGROUND: Phlebotomy performed for laboratory testing has the potential to cause anemia in newborns and infants. This study investigated the minimum specimen volume required for an automated immunohematology analyzer DAYmate S. METHODS: Three combinations of tubes were evaluated: I. 6 mL EDTA tube, II. 0.5 mL microtainer (on top of 3 mL EDTA tube), and III. 1 mL sample cup (on top of 6 mL EDTA tube). ABO/RhD cell typing was done using centrifuged red cells; unexpected antibody screening was carried out using plasma, and Type & Screening was conducted using whole blood samples. The lowest specimen volume capable of performing 10 repetitive tests without errors was investigated. RESULTS: ABO/RhD cell typing could be performed from I. 30 μL, II. 25 μL, and III. 25 μL. Unexpected antibody screening could be performed from I. 170 μL, II. 150 μL, and III. 140 μL. According to the hematocrit levels, Type & Screening could be performed from 30%, I&III 650 μL, II. 800 μL; 40%, I&III 650 μL, II. 900 μL; and 50%, I&III 1,000 μL, II. Testing using specimen volumes below 1,000 μL was difficult. CONCLUSION: By separating red cells and plasma, pre-transfusion testing of ABO/RhD cell typing and unexpected antibody screening could be conducted with very small specimen volumes using DAYmate S compared to Type & Screening using whole blood. The application of small-sized sample tubes was more competitive and this is expected to be very useful for preventing iatrogenic anemia in neonates and infants less than 4 months old.
Anemia
;
Edetic Acid
;
Hematocrit
;
Humans
;
Infant
;
Infant, Newborn
;
Mass Screening*
;
Phlebotomy
;
Plasma


Result Analysis
Print
Save
E-mail