1.Value of cell block technique as an adjunct to smear cytology in thyroid fine-needle aspiration biopsy
Nichole Andrea Bisquera ; Oliver Allan Dampil ; Bernadette Diane Vista
Philippine Journal of Pathology 2025;10(1):1-8
BACKGROUND
Thyroid fine-needle aspiration biopsy (FNAB) is widely used for thyroid nodule characterization, with approximately 2.7% of samples classified as "inadequate." Non-diagnostic samples pose limitations, resulting in repeated procedures, and unnecessary diagnostic thyroidectomies. Conventional smear (CS) is commonly the method of choice for cytologic preparation of thyroid FNAB. The cell block technique is an alternative that concentrates cells providing additional material for better evaluation and ancillary testing. While conventional smears are commonly used, introducing routine complementary cell blocks could potentially lower costs associated with repeat procedures and improve patient management.
OBJECTIVEThe study aimed to investigate the diagnostic value of incorporating the cell block technique as adjunct to conventional smear technique in reducing nondiagnostic rates (Bethesda Category I) in thyroid-fine needle aspiration biopsies (FNAB) conducted in 2 private hospitals.
METHODOLOGYThis is a multi-center, retrospective cross-sectional study with 701 samples from 528 adult patients, who underwent thyroid FNAB between January 2020 - September 2022. The primary outcome of interest is the reduction in non-diagnostic rates with the combined use of conventional smears and cell block.
RESULTSThe non-diagnostic rates were significantly higher with cell block technique (28.10%) as compared to conventional smears (16.26%), p-value < .01. The results show that conventional smears have lower non-diagnostic rates. With smear cytology alone, 114 (16.3%) of all samples were nondiagnostic. With the addition of cell block technique, 15 of these samples were reclassified as benign (n = 13), Bethesda III (n = 1) or Bethesda IV (n = 1). The rest of the non-diagnostic samples (n = 99) remained Bethesda I. Overall, the equivalent decrease in non-diagnostic rate was 2.1%.
CONCLUSIONThe combined use of cell block and conventional smears did not significantly decrease nondiagnostic rates in thyroid FNAB. In general, conventional smears demonstrated superior diagnostic efficacy across all Bethesda categories, establishing it as the preferred sampling preparation method for thyroid FNAB. Cell blocks should be considered a supplementary technique, particularly in cases where ancillary methods like immunohistochemistry or molecular testing are needed.
Biopsy, Fine-needle ; Thyroid Nodule ; Thyroid Gland ; Thyroid Diseases
2.Upgrade rate and associated predictive factors of papillary breast lesions on core needle biopsy in a private tertiary institution: A cross-sectional study
Manuelito Madrid ; Nicole Dominique Santos
Philippine Journal of Pathology 2025;10(1):17-25
OBJECTIVE
The aim of this study was to determine the upgrade rate in diagnosis of biopsy-proven papillary breast lesions on core needle biopsy and their respective surgical excisions, and to assess for predictive factors associated with an upgrade at St. Luke’s Medical Center – Global City.
METHODOLOGYA retrospective review of our institution’s database identified 184 papillary breast lesions diagnosed by core needle biopsy. The study population consisted of 71 samples that met the inclusion criteria. The overall upgrade and concordance rates were determined and analyzed if there was any significant association with clinical demographics, radiologic findings, and core diameter on gross examination. Continuous variables were presented as mean and median, and Shapiro-Wilk test was used to assess normality of data. Categorical variables were expressed as frequencies and percentages. Simple logistic regression analysis with Firth’s bias correction was performed to determine the variables associated with a diagnostic upgrade. P values ≤0.05 were considered statistically significant.
RESULTSA total 71 patients, all female, were included in the study. The overall upgrade rate was 8.45% (95% CI: 3.16-17.49%) in comparison with the diagnosis of the initial CNB and SE alone. This translated to 6/71 samples in this study. The overall concordance was 91.55% based on clinical significance, and an individual diagnosis concordance rate of 78.87%. None of the predictive factors (i.e., age, history of breast cancer, BI-RADS score, and gross core diameter) assessed showed an association with a diagnostic upgrade.
CONCLUSIONThe computed overall upgrade rate is within range of currently published literature. The concordance rates for both clinical significance and individual diagnosis were quite high, suggesting good reproducibility of histopathologic diagnosis within our institution. This was also found to be consistent with other studies. Of the predictive factors, none showed an association to a diagnostic upgrade. Despite the latter, our findings may be of value within the medical center in further exploring and expanding the data set at hand, such that it may hopefully contribute to local guidelines in managing PBLs in the future.
Papilloma ; Biopsy, Core Needle
4.Cytology Smears of Rapid On-site Evaluation as Supplemental Material for Molecular Testing of Non-small Cell Lung Cancer.
Shiqi TANG ; Chunli TANG ; Zeyun LIN ; Juhong JIANG
Chinese Journal of Lung Cancer 2024;26(12):910-918
BACKGROUND:
The thoracic small biopsy sampling procedure including transbronchial forceps lung biopsy (TBLB) and endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) can be accompanied by rapid on-site evaluation (ROSE) of sample material to provide immediate feedback for the proceduralist. The present study aims to investigate the supplemental effect of ROSE smear samples for lung cancer molecular test.
METHODS:
In a retrospective study, 308 patients admitted to our hospital from August 2020 to December 2022 undergoing diagnostic TBLB and EBUS-TBNA with ROSE and subsequently diagnosed as non-small cell lung cancer (NSCLC) were analyzed. The matched formalin-fixed paraffin-embedding (FFPE) tissue section and ROSE smears for tumor cellularity were compared. DNA yields of smears were determined. Real-time polymerase chain reaction (PCR) and next-generation sequencing (NGS) were performed on adequate smear samples.
RESULTS:
ROSE smear samples were enriched in tumor cells. Among 308 biopsy samples, 78 cases (25.3%) exhibited inadequate FFPE tissue sections, whereas 44 cases (14.3%) yielded adequate smear samples. Somatic mutations detected in the FFPE tissue section samples were also detected in the matching adequate smear sample.
CONCLUSIONS
ROSE smear samples of the thoracic small biopsies are beneficial supplemental materials for ancillary testing of lung cancer. Combined use of cytology smear samples with traditional FFPE section samples can enhance the detection rate of informative mutations in patients with advanced NSCLC. We recommend that the laboratory could further evaluate the ROSE cell smears of the patient when FFPE tissue sections are inadequate, and that adequate cell smears can be used as a supplemental source for the molecular testing of NSCLC.
Humans
;
Carcinoma, Non-Small-Cell Lung/pathology*
;
Lung Neoplasms/pathology*
;
Rapid On-site Evaluation
;
Retrospective Studies
;
Molecular Diagnostic Techniques
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods*
5.Influencing Factors of Bethesda Ⅲ Results in Fine-Needle Aspiration Biopsy of Thyroid Nodules.
Jian LIU ; Shang-Hong XIE ; Xue-Hua XI ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(6):929-933
Objective To investigate the influencing factors of Bethesda Ⅲ results in fine-needle aspiration biopsy of thyroid nodules.Methods A total of 300 thyroid nodules with cytological diagnosis results were analyzed retrospectively,including 100 Bethesda Ⅲ nodules and 50 nodules of Bethesda Ⅱ,Ⅳ,Ⅴ,and Ⅵ categories,respectively.Univariate analysis and Logistic regression analysis were performed on the clinical data of patients and the ultrasound signs of thyroid nodules to clarify the factors influencing the diagnosis of Bethesda Ⅲ nodules.Results Univariate analysis showed that Bethesda Ⅲ nodules were mostly adjacent to the capsule(P<0.001),with no blood flow in the color Doppler assessment(P=0.011)and lack of blood supply(P=0.033)and maximum diameter ≤0.9 cm(P=0.038)as revealed by the contrast-enhanced ultrasound.Logistic regression showed that the position close to the capsule(OR=5.110,95%CI=2.153-12.130,P<0.001)and color Doppler without blood flow signal(OR=3.015,95%CI=1.094-8.311,P=0.033)were independent risk factors for the diagnosis of Bethesda Ⅲ nodules.Conclusions The puncture difficulty caused by the dangerous position of thyroid nodules close to the capsule and the aspiration difficulty caused by the absence of blood flow signal in color Doppler are the main factors influencing the diagnosis of Bethesda Ⅲ nodules.Therefore,corresponding avoidance measures should be taken during the aspiration process to reduce the diagnosis results of Bethesda Ⅲ nodules.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Thyroid Neoplasms/diagnosis*
;
Biopsy, Fine-Needle/methods*
;
Retrospective Studies
;
Ultrasonography/methods*
6.Application of Rapid HE Staining in Cytological Rapid On-site Evaluation of Peripheral Lung Cancer Needle Biopsy.
Jian HE ; Guilan XIA ; Shiping WANG ; Kun CHEN
Chinese Journal of Lung Cancer 2023;26(8):572-578
BACKGROUND:
Rapid on-site evaluation (ROSE) is a technique used for simultaneous evaluation of biopsy specimens through rapid cytology staining. Diff-Quik (DQ) staining is the most commonly employed method for cytological rapid on-site evaluation (C-ROSE). However, the utilization of DQ staining for on-site cytological interpretation remains uncommon among pathologists in China, posing challenges to the implementation of C-ROSE. This study aims to assess the application of rapid hematoxylin-eosin (HE) staining and DQ staining for C-ROSE during percutaneous needle biopsy of peripheral lung cancer and evaluate the value of rapid HE staining in C-ROSE.
METHODS:
Computed tomography (CT)-guided lung biopsies were conducted on 300 patients diagnosed with peripheral lung cancer. The patients were randomly assigned to two groups for C-ROSE using either rapid HE staining or DQ staining, and subsequently the two methods were compared and evaluated.
RESULTS:
The concordance rate between C-ROSE and histopathological diagnosis was 96.7%. The median staining time for rapid HE staining was 160 s, while that for DQ staining was 120 s, representing a significant difference between the two groups (P<0.001). However, there were no significant differences observed in terms of total biopsy time, concordance rate with histopathology, cytology specimen peeling rate, and incidence of serious adverse reactions between the two groups (P>0.05).
CONCLUSIONS
Both staining methods comply with C-ROSE criteria in the biopsy setting of peripheral lung cancer. Rapid HE staining is more aligned with domestic clinical requirements and holds potential for further promotion and adoption in C-ROSE.
Humans
;
Lung Neoplasms/pathology*
;
Eosine Yellowish-(YS)
;
Rapid On-site Evaluation
;
Biopsy, Needle/methods*
;
Staining and Labeling
7.New progress in the surgical treatment of laryngeal cyst in infants and children.
Huiying LV ; Yihua NI ; Chao CHEN ; Wenxia CHEN ; Zhengmin XU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(12):968-971
Laryngeal cyst is a cystic lesion occurring in the laryngeal cavity. Large laryngeal cyst in infants and young children can cause laryngeal wheezing and other upper airway obstruction symptoms. In severe cases, it can be even life-threatening and requires timely surgical treatment. Currently, there is a lack of unified clinical treatment strategy for this disease.This article summarizes the surgical methods, the advantages and disadvantages of various surgical methods for laryngeal cysts in recent years. It is recommended that needle aspiration, partial cyst wall resection, radical cyst dissection, transoral robotic surgery or external approach cyst resection should be selected through full communication and evaluation to clarify the extent of the lesion scope and the advantages and disadvantages of surgery.
Infant
;
Child
;
Humans
;
Child, Preschool
;
Cysts/diagnosis*
;
Laryngeal Diseases/diagnosis*
;
Larynx/surgery*
;
Robotic Surgical Procedures
;
Biopsy, Needle
9.Influencing Factors and Prediction Model of Performance of Needle Visualization in Fine Needle Aspiration of Thyroid Nodules.
Liang-Kai WANG ; Jia-Jia TANG ; Wen-Quan NIU ; Xin-Ying JIA ; Xue-Hua XI ; Jiao-Jiao MA ; Hui-Lin LI ; Zhe SUN ; Xin-Yi LIU ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(3):366-373
Objective To investigate the influencing factors and establish a model predicting the performance of needle visualization in fine-needle aspiration (FNA) of thyroid nodules. Methods This study prospectively included 175 patients who underwent FNA of thyroid nodules in the Department of Ultrasound in China-Japan Friendship Hospital and compared the display of the needle tips in the examination of 199 thyroid nodules before and after the application of needle visualization.We recorded the location,the positional relationship with thyroid capsule,ultrasonic characteristics,and the distribution of the soft tissue strip structure at the puncture site of the nodules with unclear needle tips display before using needle visualization.Furthermore,according to the thyroid imaging reporting and data system proposed by the American College of Radiology,we graded the risk of the nodules.Lasso-Logistic regression was employed to screen out the factors influencing the performance of needle visualization and establish a nomogram for prediction. Results The needle tips were not clearly displayed in the examination of 135 (67.8%) and 53 (26.6%) nodules before and after the application of needle visualization,respectively,which showed a significant difference (P<0.001).Based on the positional relationship between the nodule and capsule,anteroposterior/transverse diameter (A/T) ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site,a nomogram was established to predict the probability of unclear display of the needle tips after application of needle visualization.The C-index of the prediction model was 0.75 (95%CI=0.67-0.84) and the area under the receiver operating characteristic curve was 0.72.The calibration curve confirmed the appreciable reliability of the prediction model,with the C-index of 0.70 in internal validation. Conclusions Needle visualization can improve the display of the needle tip in ultrasound-guided FNA of thyroid nodules.The nomogram established based on ultrasound features such as the positional relationship between the nodule and capsule,A/T ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site can predict whether needle visualization is suitable for the examination of nodules.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Biopsy, Fine-Needle/methods*
;
Reproducibility of Results
;
Ultrasonography
;
Retrospective Studies
;
Thyroid Neoplasms
10.Diagnostic values of nuclear score combined with cyclin D1 immunocytochemistry in indeterminate thyroid follicular nodules in preoperative fine needle aspiration.
Shu Rong HE ; Long Teng LIU ; Rong Ming CHEN ; Meng Ge WANG ; Song Tao HU ; Gang MIAO ; Lan CHEN ; Dong Ge LIU
Chinese Journal of Pathology 2023;52(7):696-701
Objective: To assess the feasibility of nuclear score combined with cyclin D1 immunocytochemistry in classifying indeterminate thyroid nodules with fine-needle aspiration (FNA) cytological diagnosis of Bethesda category Ⅲ-Ⅴ. Methods: A consecutive cohort of 118 thyroid FNA specimens with indeterminate diagnosis (TBSRTC category Ⅲ-Ⅴ) and available histopathologic follow-up data were collected between December 2018 and April 2022 at the Department of Pathology, Beijing Hospital, China. These cases were subjected to cytological evaluation and cyclin D1 immunocytochemistry. The optimal cut-off points of a simplified nuclear score and the percentage of cyclin D1-positive cells for the diagnosis of malignancy or low-risk neoplasm were determined using the receiver operating characteristic (ROC) curves and area under the ROC curve (AUC). The specificity, sensitivity, positive predictive value (PPV) and negative predictive value (NPV) of nuclear score and cyclin D1 immunostaining were evaluated from the crosstabs based on cut-off points. The diagnostic accuracy of simplified nuclear score combined with cyclin D1 immunostaining was estimated using ROC curve analysis. Results: Nuclear grooves, intra-nuclear inclusions and chromatin clearing were more commonly found in malignancy/low-risk neoplasms than benign lesions (P=0.001, P=0.012 and P=0.001 respectively). A cut-off point of≥2 for the simplified nuclear score was sensitive for defining malignancy/low-risk neoplasm, and its PPV, NPV, sensitivity and specificity were 93.6%, 87.5%, 99.0% and 50.0% respectively. A positive cut-off point of 10% positive thyroid cells in cyclin D1 immunostaining demonstrated sensitivity of 88.5%, specificity of 100%, PPV of 100% and NPV of 53.8% for correctly detecting thyroid malignancy or low-risk neoplasm. The sensitivity and PPV of simplified nuclear score combined with cyclin D1 immunostaining were 93.3% and 100%, respectively. Both specificity and NPV were maintained at high levels (100% and 66.7%, respectively). The diagnostic accuracy of simplified nuclear score combined with cyclin D1 immunostaining in detecting thyroid malignancy/low-risk neoplasm was increased to 94.1% compared to using either of them alone. Conclusions: Combing simplified nuclear score and cyclin D1 immunostaining on FNA cytology specimens can increase the diagnostic accuracy in classifying thyroid nodules of indeterminate cytological categories. Thus, this supplementary approach provides a simple, accurate, and convenient diagnostic method for cytopathologists so that may reduce unnecessary thyroidectomies.
Humans
;
Thyroid Nodule/pathology*
;
Biopsy, Fine-Needle
;
Cyclin D1
;
Immunohistochemistry
;
Thyroid Neoplasms/pathology*
;
Retrospective Studies


Result Analysis
Print
Save
E-mail