1.Finite element analysis of optimal fixation method for femoral neck fracture with different reduction conditions
Biao HAN ; Ji LI ; Bin LI ; Bo SUN ; Shuangle ZONG ; Hongrun WANG ; Dongmei LI ; Ligeng LI ; Bin WANG
Chinese Journal of Tissue Engineering Research 2024;28(12):1810-1814
BACKGROUND:The traditional fixation method for femoral neck fractures is three hollow screws inverted triangle fixation,and the optimal fixation method for femoral neck fractures that have not achieved anatomical reduction is inconclusive. OBJECTIVE:To compare the biomechanical properties of cannulated screws internal fixation for sub-capitated femoral neck fracture with different reduction qualities based on finite element analysis. METHODS:The three-dimensional digital model was reconstructed using CT data of the proximal femur from a healthy male volunteer.The femur was modeled to sub-capitated femoral neck fractures.Fracture models were divided into anatomical reduction group,coxa vara group,and coxa valgus group.All fracture model groups were transferred using the standard group,screw depression group,and screw elevation group.A vertical downward stress of 1 400 N was applied to the femoral head at the top of the acetabulum.The displacement and stress distribution of the femur and internal fixator under different fixation methods were observed,and the maximum stress and displacement of the femur and fixator were compared. RESULTS AND CONCLUSION:(1)For anatomical reduction femoral neck fracture,the peak stress of fixation in the standard group,screw depression group and screw elevation group was 41.35,31.27 and 43.32 MPa,respectively.The maximum peak stress of the femur was found on the screw elevation group(28.58 MPa),and the standard group had the maximum peak displacement.(2)During hip varus,the stresses in the three subgroups were relatively dispersed and even.The peak stress of the femur in the standard group was the smallest,but the peak displacement was the largest.The stability of fixation might be poor.The peak displacement of the femur in the screw depression group was the smallest.(3)In the hip valgus,obvious screw stress concentration appeared in the screw depression group,and the peak displacement was the largest among the three subgroups,and an in-out-in phenomenon appeared.The peak stress of the screws in the screw elevation group was the largest among the three subgroups,but the peak displacement was the smallest.(4)It is concluded that for sub-capitated femoral neck fractures that are completely anatomically reduced,it is recommended to use standard inverted triangular nails for fixation.When the hip varus and hip valgus occur within the allowable range of the reduction standard,it is recommended to use the inverted triangle screw to fix it by rotating the corresponding angle in the same direction as the hip varus or valgus.
2.Quantitative CT measurement of bone mass density in different regions of the distal clavicle in reconstruction of acromioclavicular joint dislocation
Jian XU ; Wenzhi BI ; Yuncong JI ; Yunkang KANG ; Peiqi MA ; Jialiang WANG ; Zongxi ZHANG ; Fusheng GAN ; Haiyang YU ; Biao GUO
Chinese Journal of Tissue Engineering Research 2024;28(12):1920-1924
BACKGROUND:There is no consensus on the optimal bone tunnel position in the lateral clavicle,which guides coracoclavicular ligament reconstruction.Postoperative complications such as enlargement of the lateral clavicle bone tunnel,bone osteolysis,clavicle fracture,and failure of internal fixation are likely to occur.Bone mass density plays an important role in the strength and stability of endophytic fixation.Regional differences in the bone mass density of the distal clavicle should not be overlooked in the repair and reconstruction of acromioclavicular dislocation.Currently,there are no quantitative clinical studies in humans regarding the bone mass density of the distal clavicle. OBJECTIVE:To measure the magnitude of bone mass density in different regions of the distal clavicle by quantitative CT to provide a reference for surgeons to repair and reconstruct the coracoclavicular ligament. METHODS:101 patients undergoing quantitative CT checking in Fuyang People's Hospital Affiliated to Anhui Medical University from October to December 2022 were enrolled,from which 1 616 samples of subdivisional bone mass density of the distal clavicle were measured.For each of the quantitative CT samples,firstly,the distal clavicle was divided medially to laterally into the following four regions:conical nodal region(region A),inter-nodal region(region B),oblique crest region(region C)and distal clavicular region(region D).Secondly,each region was divided into the first half and the second half to determine eight subdivisions,then setting semiautomatic region of interest(ROI)in each subdivision:(ROI A1,A2,B1,B2,C1,C2,D1,and D2).Thirdly,each quantitative CT scan was transferred to the quantitative CT pro analysis workstation,and cancellous bone mass density was measured in the distal clavicle ROI.Finally,the clavicular cortex was avoided when measuring. RESULTS AND CONCLUSION:(1)There was no statistically significant difference in bone mineral density on the different sides of the shoulder(P>0.05).(2)The analysis of bone mineral density in eight sub-areas of the distal clavicle A1,A2,B1,B2,C1,C2,D1,and D2 showed statistically significant differences(P<0.05).It could be considered that there were differences in bone mineral density in different areas of the distal clavicle.After pairwise comparison,there was no statistically significant difference in bone mineral density between A1 and A2,D1 and D2,A2 and B1(P>0.05),and there was a statistically significant difference in bone mineral density between the other sub-areas(P<0.05).(3)The bone mineral density in the region A2 of the anatomical insertion of the conical ligament was significantly higher than that in the inter-nodular area(region B)(P<0.05).The bone mineral density in the region A1 was higher than that in the region A2,but the difference was not statistically significant(P>0.05).The bone mineral density in the region C1 of the anatomical insertion of the trapezium ligament was higher than that in regions C2,D1 and D2,and the bone mineral density in the inter-nodular area(region B)was significantly higher than that in regions C and D(P<0.05).(4)These results have suggested that there are differences in bone mass density in different regions of the distal clavicle;regional differences in bone mass density in the distal clavicle during repair and reconstruction of acromioclavicular dislocation cannot be ignored.Consideration should be given not only to biomechanical factors but also to the placement of implants or bone tunnels in regions of higher bone mass density,which could improve the strength and stability of implant fixation and reduce the risk of complications such as bone tunnel enlargement,osteolysis,fracture and implant failure.
3.Transcutaneous Electrical Acupoint Stimulation Promotes PGC-1α Mediated Mitochondrial Biogenesis and Antioxidant Stress to Protect Cognitive Function in Vascular Dementia Rats
Ji-Liang KANG ; Ke HU ; Jun-Yue LU ; Zi-Wei HU ; Biao-Ping XU ; Xiao-Mao LI ; Jun-Jie ZHOU ; Yu JIN ; Min TANG ; Rong XU ; You-Liang WEN
Progress in Biochemistry and Biophysics 2024;51(5):1191-1202
ObjectiveThe purpose of this study was to investigate the effects of transcutaneous electrical acupoint stimulation (TEAS) on cognitive function of vascular dementia (VD) rats and its mechanism. MethodsVD rat model was established by modified two-vessel occlusion (2-VO). After modeling, TEAS and electroacupuncture (EA) were used to stimulate Baihui and Zusanli points of rats respectively for 14 d. After treatment, novel object recognition test, Morris water maze test, and Y maze test were used to evaluate the spatial memory and learning ability of rats. Hematoxylin and eosin staining was used to observe the morphology of hippocampal neurons. Transmission electron microscopy was used to observe the ultrastructure of hippocampal mitochondria. Enzyme-linked immunosorbent assay kits were used to detected the levels of SOD, CAT, GSH-Px, MDA and ROS in serum of rats. Western blot was used to detect the expression of PGC-1α, TFAM, HO-1, NQO1 proteins in the hippocampus, Keap1 protein in the cytoplasm and Nrf2, NRF1 proteins in the nucleus. ResultsAfter treatment for 14 d, compared to the model group, the escape latency of VD rats decreased, while the discrimination index, the times of rats crossing the original platform area, the residence time in the original platform quadrant, and the percentage of alternation increased. TEAS can improve the structure of hippocampal neurons and mitochondria of VD rats, showing that neurons were arranged more regularly and distributed more evenly, nuclear membrane and nucleoli were clearer, and mitochondrial swelling were reduced, mitochondrial matrix density were increased, and mitochondrial cristae were more obvious. The levels of SOD, GSH-Px and CAT in serum increased significantly, while the concentration of MDA and ROS decreased. TEAS also up-regulated the expression levels of PGC-1α TFAM, NQO1 and HO-1 proteins in the hippocampus and Nrf2, NRF1 proteins in the nucleus, but down-regulated the Keap1 protein in the cytoplasm. ConclusionTEAS can improve cognition, hippocampal neurons and mitochondrial structure of VD rats, and the effect is better than EA. The mechanism may be the activation of PGC-1α mediated mitochondrial biogenesis and antioxidant stress, which also provides a potential therapeutic technology and experimental basis for the treatment of VD.
4.Efficacy of arthroscopic superior capsular reconstruction using composite autologous patch graft combined with tenodesis of the long head of the biceps tendon in the treatment of irreparable massive rotator cuff tears
Yuncong JI ; Jian XU ; Yunkang KANG ; Wenzhi BI ; Wei MA ; Dongqiang YANG ; Honglin CUI ; Pengfei FU ; Yijun LIU ; Jinxiang TIAN ; Biao GUO
Chinese Journal of Trauma 2024;40(3):236-242
Objective:To investigate the efficacy of arthroscopic superior capsular reconstruction using composite autologous patch graft combined with tenodesis of the long head of the biceps tendon in the treatment of irreparable massive rotator cuff tears (IMRCT).Methods:A retrospective case series study was performed on 11 IMRCT patients who were admitted to Affiliated Fuyang Hospital of Bengbu Medical University (Fuyang People′s Hospital) from May 2020 to June 2022, including 7 males and 4 females, aged 54-74 years [(62.6±7.3)years]. All the patients were treated with arthroscopic superior capsular reconstruction using composite patch graft combined with tenodesis of the long head of the biceps tendon. The Visual Analogue Scale (VAS), Acromiohumeral Distance (AHD), Constant-Murley score and University of California Los Angeles (UCLA) score and active range of motion of the shoulder joint before, at 6 months after surgery and at the last follow-up were compared. At the last follow-up, the integrity of reconstructed superior capsule and the long head of the biceps tendon was evaluated using MRI of the shoulder joint. Postoperative complications were observed.Results:All the patients were followed up for 13-39 months [16(13, 36)months]. The VAS score, AHD, Constant-Murley score, and UCLA score were 2(2, 3)points, (9.1±1.1)mm, (56.1±5.4)points, and (19.7±2.8)points respectively at 6 months after surgery, which were all significantly improved from those before surgery [6(5, 7)points, (5.1±1.2)mm, (37.9±2.2)points, and (11.8±1.2)points] ( P<0.05). The VAS score, AHD, Constant-Murley score, and UCLA score were 0(0, 1)points, (8.4±0.9)mm, (83.6±3.8)points, and (28.2±2.3)points respectively at the last follow-up, which were all significantly improved from those before surgery ( P<0.05). At the last follow-up, the VAS score or AHD were not significantly improved from those at 6 months after surgery ( P>0.05); Constant-Murley score and UCLA score were both significantly improved from those at 6 months after surgery ( P<0.05). At 6 months after surgery, shoulder active ranges of motion in forward flexion, abduction and external rotation were (134.6±13.5)°, (124.6±18.6)° and 45(40, 50)° respectively, which were all significantly improved compared with those before surgery [(63.2±36.1)°, (65.0±23.1)°, and [30(20, 40)°] ( P<0.05). At the last follow-up, shoulder active ranges of motion in forward flexion, abduction and external rotation were (144.1±12.6)°, (139.6±15.4)° and 60(45, 65)° respectively, which were all significantly improved compared with those before surgery ( P<0.05). There were no significant differences in active range of motion of the shoulder in forward flexion, abduction and external rotation between 6 months after surgery and the last follow-up ( P>0.05). At the last follow-up, MRI revealed integrity of the reconstructed superior joint capsule and the long head of the biceps tendon in 10 patients. One patient developed resorption of the greater tuberosity and 1 showed a partial tear of the supraspinatus tendon at 1 year after surgery. Conclusion:Arthroscopic superior capsular reconstruction using composite autologous patch graft combined with tenodesis of the long head of the biceps tendon can relieve shoulder pain, decrease upward displacement of the humerus head, improve the function and range of motion of the shoulder joint, and reduce complications in the treatment of IMRCT.
5.Genetic characterization of varicella-zoster virus in Jilin province from 2010 to 2023
Xiang LI ; Leilei WEI ; Biao HUANG ; Tao CHENG ; Yuanchun SHAN ; Guixiang QIN ; Hongyan SUN ; Shangwei JI ; Xin TIAN ; Simei FU ; Shuang WANG
Chinese Journal of Experimental and Clinical Virology 2024;38(5):521-526
Objective:This study aimed to analyze the genomic characteristics of Varicella-Zoster Virus (VZV) strains circulating in Jilin province from 2010 to 2023.Methods:Vesicle fluid from 78 sporadic cases with VZV infection were collected in Jilin province from 2010 to 2023, after detecting by Real-time PCR, 26 specimens (CT<25) were detected by PCR. Open reading frame 22(ORF22), ORF38 and ORF62 were amplified and analyzed. Genotyping was confirmed by SNPs ORF22 (37902, 38019, 38055, 38081 and 38177) and ORF38 (69424). Vaccine strains were indentified from wild-type strains according to ORF38 (69349) and ORF62 (106262, 107252, and 108111). Sequences were analyzed by homologous comparison and phylogenetic analysis.Results:The comparison with Dumas sequence revealed that SNPs (37902, 38055, 38081 and 38177) in ORF22 and ORF38 (69424) have mutations similar to the pOka strain, which belong to clade 2. Compared to the Dumas and Baike strains, all 26 samples were wild-type strains. JL2016-4 strain changes from threonine to asparaginyl at position 38059, JL2021-4 strain changes from arginine to proline at position 37933, from aspartic acid to tyrosine at position 37935, and from aspartic acid at base 38031 to tyrosine. JL2023-1 strain changes from arginine to leucine at position 37933.Conclusions:VZV has been prevalent for 14 years in Jilin province. The main epidemic strains belong to the clade 2. We should strengthen the monitoring of VZV outbreaks and raise the coverage rate of VZV vaccination.
6.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
7.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
8.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
9.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
10.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.

Result Analysis
Print
Save
E-mail