1.Implant-assisted removable partial denture (IARPD) rehabilitation in a patient exhibiting mandibular prognathism due to decreased vertical dimension: a case report
Hye-Kyoung HWANG ; Young-Jun LIM ; Ho-Beom KWON ; Myung-Joo KIM
The Journal of Korean Academy of Prosthodontics 2025;63(1):82-91
The loss of occlusal vertical dimension due to multiple tooth loss and wear can lead to a collapsed occlusion, resulting in both functional and aesthetic problems.This case report describes a patient exhibiting mandibular prognathism as a result of vertical dimension loss. A comprehensive oral rehabilitation involving an increase in vertical dimension was required. A minimal number of implants were placed, and implant-supported surveyed crowns were fabricated, allowing for the design of a stable and retentive implant-assisted removable partial denture. The treatment resulted in both functional and aesthetic improvements. The anterior rotational pattern of the mandible was alleviated, and the implant-assisted partial denture provided clinically high levels of patient satisfaction. This case report details the diagnostic and therapeutic processes involved in this treatment.
2.Full mouth rehabilitation of a crossed-occlusion patient using digital printing technology
Jae-Bok LEE ; Young-Jun LIM ; Ho-Beom KWON ; Myung-Joo KIM
The Journal of Korean Academy of Prosthodontics 2025;63(1):31-39
Crossbite refers to a condition where there are remaining teeth, but none of the teeth are in occlusal contact, resulting in the loss of vertical support. When posterior vertical stop is lost, it is important to appropriately restore this support and create a harmonious occlusal plane. In this case, the patient had lost posterior support but declined surgical intervention due to a history of osteoporosis and the associated risk of medication-related osteonecrosis of the jaw (MRONJ). To restore the vertical space required for prosthetic rehabilitation, the vertical dimension was increased. The missing posterior teeth were replaced using removable partial dentures. Cross-mounting was performed, and the metal copings of the surveyed crowns and the framework of the final removable partial denture were 3D printed. After the treatment was completed, the patient expressed satisfaction with both functions and aesthetics. Regular follow-ups were conducted to monitor oral hygiene and occlusal stability.
3.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
4.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
5.Implant-assisted removable partial denture (IARPD) rehabilitation in a patient exhibiting mandibular prognathism due to decreased vertical dimension: a case report
Hye-Kyoung HWANG ; Young-Jun LIM ; Ho-Beom KWON ; Myung-Joo KIM
The Journal of Korean Academy of Prosthodontics 2025;63(1):82-91
The loss of occlusal vertical dimension due to multiple tooth loss and wear can lead to a collapsed occlusion, resulting in both functional and aesthetic problems.This case report describes a patient exhibiting mandibular prognathism as a result of vertical dimension loss. A comprehensive oral rehabilitation involving an increase in vertical dimension was required. A minimal number of implants were placed, and implant-supported surveyed crowns were fabricated, allowing for the design of a stable and retentive implant-assisted removable partial denture. The treatment resulted in both functional and aesthetic improvements. The anterior rotational pattern of the mandible was alleviated, and the implant-assisted partial denture provided clinically high levels of patient satisfaction. This case report details the diagnostic and therapeutic processes involved in this treatment.
6.Full mouth rehabilitation of a crossed-occlusion patient using digital printing technology
Jae-Bok LEE ; Young-Jun LIM ; Ho-Beom KWON ; Myung-Joo KIM
The Journal of Korean Academy of Prosthodontics 2025;63(1):31-39
Crossbite refers to a condition where there are remaining teeth, but none of the teeth are in occlusal contact, resulting in the loss of vertical support. When posterior vertical stop is lost, it is important to appropriately restore this support and create a harmonious occlusal plane. In this case, the patient had lost posterior support but declined surgical intervention due to a history of osteoporosis and the associated risk of medication-related osteonecrosis of the jaw (MRONJ). To restore the vertical space required for prosthetic rehabilitation, the vertical dimension was increased. The missing posterior teeth were replaced using removable partial dentures. Cross-mounting was performed, and the metal copings of the surveyed crowns and the framework of the final removable partial denture were 3D printed. After the treatment was completed, the patient expressed satisfaction with both functions and aesthetics. Regular follow-ups were conducted to monitor oral hygiene and occlusal stability.
7.Immunologic Response and Effects of COVID-19Vaccines in Patients with Antineutrophil Cytoplasmic Antibody-Associated Vasculitis
Ki Hyun LEE ; Hyunsue DO ; Jun Yong CHOI ; Yong-Beom PARK ; Sinyoung KIM ; Sang-Won LEE ; Su Jin JEONG
Yonsei Medical Journal 2025;66(5):259-268
Purpose:
The immunological response and adverse effects of antineutrophil cytoplasmic antibody-associated vasculitis (AAV) in patients receiving coronavirus disease-2019 (COVID-19) vaccines remain unclear. We aimed to evaluate the effects of these vaccines on AAV disease activity.
Materials and Methods:
We reviewed the medical records of 52 patients with AAV who had received at least second doses of the COVID-19 vaccine and evaluated their immunogenicity by measuring the anti-spike (S) antibody (Ab) titer levels using the Roche Elecsys® immunoassay. Responses to the Birmingham Vasculitis Activity Score (BVAS) tool and 36-Item Short Form Survey before and after vaccination were obtained to assess AAV disease activity. Vaccine reactivity was measured using a standardized questionnaire.
Results:
We enrolled 52 patients with AAV. No differences were found between those who received second and third doses of vaccination in terms of AAV type, disease activity, vaccine type, or the use of immunosuppressive agents, including steroids. The median anti-S Ab titer was 3967.0 after third doses compared to 419.0 after second doses (p=0.001). Except for mycophenolate mofetil (MMF), when immunosuppressants were administered in conjunction with steroids, the Ab titer was higher after the third vaccination than that after the second dose. The BVAS remained unchanged before and after second and third doses. No life-threatening adverse events were reported.
Conclusion
Although COVID-19 vaccine may not produce sufficient antibodies in patients taking MMF, the vaccine did not exacerbate disease activity or cause severe side effects. Therefore, COVID-19 vaccines should be considered in patients with AAV.
8.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
9.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
10.Immunologic Response and Effects of COVID-19Vaccines in Patients with Antineutrophil Cytoplasmic Antibody-Associated Vasculitis
Ki Hyun LEE ; Hyunsue DO ; Jun Yong CHOI ; Yong-Beom PARK ; Sinyoung KIM ; Sang-Won LEE ; Su Jin JEONG
Yonsei Medical Journal 2025;66(5):259-268
Purpose:
The immunological response and adverse effects of antineutrophil cytoplasmic antibody-associated vasculitis (AAV) in patients receiving coronavirus disease-2019 (COVID-19) vaccines remain unclear. We aimed to evaluate the effects of these vaccines on AAV disease activity.
Materials and Methods:
We reviewed the medical records of 52 patients with AAV who had received at least second doses of the COVID-19 vaccine and evaluated their immunogenicity by measuring the anti-spike (S) antibody (Ab) titer levels using the Roche Elecsys® immunoassay. Responses to the Birmingham Vasculitis Activity Score (BVAS) tool and 36-Item Short Form Survey before and after vaccination were obtained to assess AAV disease activity. Vaccine reactivity was measured using a standardized questionnaire.
Results:
We enrolled 52 patients with AAV. No differences were found between those who received second and third doses of vaccination in terms of AAV type, disease activity, vaccine type, or the use of immunosuppressive agents, including steroids. The median anti-S Ab titer was 3967.0 after third doses compared to 419.0 after second doses (p=0.001). Except for mycophenolate mofetil (MMF), when immunosuppressants were administered in conjunction with steroids, the Ab titer was higher after the third vaccination than that after the second dose. The BVAS remained unchanged before and after second and third doses. No life-threatening adverse events were reported.
Conclusion
Although COVID-19 vaccine may not produce sufficient antibodies in patients taking MMF, the vaccine did not exacerbate disease activity or cause severe side effects. Therefore, COVID-19 vaccines should be considered in patients with AAV.

Result Analysis
Print
Save
E-mail