1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
		                        		
		                        			 Purpose:
		                        			The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations. 
		                        		
		                        			Methods:
		                        			This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits. 
		                        		
		                        			Results:
		                        			Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01). 
		                        		
		                        			Conclusion
		                        			Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors. 
		                        		
		                        		
		                        		
		                        	
6.Detection of germline variants in pancreatic cancer by next-generation sequencing and correlation analysis of clinical factors
Hui-Qin JIANG ; Li ZHANG ; Fei HUANG ; Xin-Ning CHEN ; Li YU ; Min-Na SHEN ; Bei-Li WANG ; Bai-Shen PAN ; Wei GUO
Fudan University Journal of Medical Sciences 2024;51(1):19-24
		                        		
		                        			
		                        			Objective To investigate the rate of germline variants in patients with pancreatic cancer and clinical characteristics related with germline variants.Methods A total of 271 patients diagnosed with pancreatic cancer were enrolled in this study.Germline variants of 21 tumor susceptibility genes were detected by next-generation sequencing,and the relationship between germline variants and clinical factors such as age of onset,family history and personal history was analyzed.Results The rate of germline P/LP variants was 6.3%in unselected pancreatic cancer patients,but was high as 17.1%in genetic high-risk group patients(those with a family or personal history of cancer,or early-onset).Genes with higher frequency of germline variants in pancreatic cancer patients were PALB2,BRCA2,and ATM.Conclusion The rate of germline variants in overall pancreatic cancer patients is not high,but it increases significantly in genetic high-risk group,proving the importance of clinical factors in the screening of hereditary pancreatic cancer.
		                        		
		                        		
		                        		
		                        	
7.The value of high-throughput sequencing data reanalysis in identifying ERBB2 amplification in colorectal cancer patients
Min-Na SHEN ; Li ZHANG ; Xin-Ning CHEN ; Fei HUANG ; Chao-Gang BAI ; Li-Meng CHEN ; Hai-Xiang PENG ; Yan ZHOU ; Bei-Li WANG ; Bai-Shen PAN ; Wei GUO
Fudan University Journal of Medical Sciences 2024;51(2):166-171
		                        		
		                        			
		                        			Objective To evaluate the value of high-throughput sequencing(HTS)data reanalysis that does not include ERBB2 copy number variation(CNV)analysis,in identifying ERBB2 amplification in patients with colorectal cancer.Methods The HTS data of 252 cases of colorectal cancer diagnosed by pathological biopsy who received peripheral blood cfDNA HTS detection samples were retrospectively analyzed.According to the HTS data of ERBB2 non-amplified samples judged by immunohistochemistry(IHC)and/or fluorescence in situ hybridization(FISH),the number of chromosome 17(Chr17)reads in the total number of reads was calculated the range of the ratio was initially determined as the threshold for prompting ERBB2 amplification.Suspected positive samples were screened according to thresholds and verified by digital PCR,IHC and FISH.Results The proportion of the number of Chr17 reads accounts for the number of total reads in the 89 cases of ERBB2 non-amplified samples determined by IHC and/or FISH ranged from 0.188 to 0.299(0.239±0.192).Using 0.298(1.25 times the mean)as the threshold indicating ERBB2 amplification,the data of 163 samples were analyzed,of which 7 cases were suspected to be positive,and the ratio ranged from 0.302 to 0.853.Among them,5 cases were determined to be positive by IHC and/or FISH,and 6 cases were confirmed to be positive by digital PCR.The ratio of the number of Chr17 reads to the number of total reads was positively correlated with the ratio of ERBB2/EIF2C1,and the correlation was good(r2=0.909).Conclusion The high-throughput sequencing data that does not cover the ERBB2 CNV analysis has a certain hint value for ERBB2 amplification in patients with colorectal cancer.
		                        		
		                        		
		                        		
		                        	
		                				8.Establishment and evaluation of a rapid PCR-colloidal gold test strip method for the detection of Fritillaria ussuriensis 
		                			
		                			Yu-he MA ; Cong-hui SHANG ; Qiu-he MA ; Tao LI ; Yue LIU ; Bei-zhen PAN ; Li-jun GAO ; Ming-cheng LI ; Wei XIA ; Yong-mei QU
Acta Pharmaceutica Sinica 2024;59(6):1773-1778
		                        		
		                        			
		                        			 This study design of specific identification primers for the ITS2 sequence of 
		                        		
		                        	
9.Clinical correlation between TNFRSF12A and hepatocellular carcinoma and its effect on immunoregulation of tumor cells
Jie ZHU ; Pei-Qi FANG ; Bai-Shen PAN ; Wei GUO ; Bei-Li WANG
Fudan University Journal of Medical Sciences 2024;51(3):368-377
		                        		
		                        			
		                        			Objective To investigate the role of the TNFRSF12A molecule in the pathogenesis of liver cancer.Methods Through comprehensive analysis of the Cancer Genome Atlas Program(TCGA)database and single-cell sequencing data,we studied the expression of TNFRSF12A in liver cancer and its correlation with prognosis.HPA database was utilized to analyze the subcellular localization of TNFRSF12A,and GO and KEGG analyses were performed by DAVID.TIME 2.0 was employed to analyze the correlation between TNFRSF12A and immune cell infiltration in liver cancer tissues.Results TNFRSF12A was found to be highly expressed in liver cancer tissues,significantly correlating with patient survival prognosis(OS:HR=1.61,P=0.007 0;RFS:HR=1.45,P=0.037 0;PFS:HR=1.30,P=0.099 0;DSS:HR=1.67,P=0.027 0),as well as age(P=0.046 7)and BCLC stage(P=0.045 6).TNFRSF12A co-expressed with tumor stem cell markers(CD24,SOX4,ANPEP),indicating a strong link to malignancy.Furthermore,molecular functional analysis unveiled that IL-2R primarily existed in the cell cytoplasm and played a role in processes such as cell apoptosis,invasion,and protein binding.Moreover,TNFRSF12A was associated with Treg cells and immune cell infiltration,further suggesting its role in tumor immune regulation.Conclusion TNFRSF12A exhibits a significant elevation within liver tumors and shows a notable correlation with patients'prognosis.Tumor cells engage in interactions with cytokines produced by Tregs,thereby reshaping the tumor microenvironment.The potential clinical significance of TNFRSF12A as a prognostic marker for tumors holds promise in offering novel avenues for personalized treatment and prognosis prediction.
		                        		
		                        		
		                        		
		                        	
10.Diagnostic value of vena contracta area measurement for grading tricuspid regurgitation severity under different etiologies:a three-dimensional echocardiography study
Bei-Qi CHEN ; Yu LIU ; Wu-Xu ZUO ; Quan LI ; Yuan-Feng WU ; De-Hong KONG ; Cui-Zhen PAN ; Li-Li DONG ; Xian-Hong SHU
Fudan University Journal of Medical Sciences 2024;51(4):484-493,504
		                        		
		                        			
		                        			Objective To explore the cut-off value of three dimensional(3D)vena contracta area(VCA)in diagnosing severe tricuspid regrugitation(TR)under different etiologies and its accuracy and practicality in clinical application.Methods From Mar 2019 to May 2021,ninety-two patients with confirmed TR underwent two dimensional(2D)and 3D transthoracic echocardiography.The correlation and consistency between 3D VCA 3D calculated based on the proximal isokinetic surface area(PISA)effective regurgitant orifice area(EROA)was calculated.Comprehensive 2D multi-parameter method was used as a reference method to calculate the cut-off value of the diagnosis of severe TR.Results A total of 85 patients were ultimately included.3D VCA and 3D PISA EROA had similar and acceptable correlations in both primary TR and secondary TR(primary TR:r=0.831,P<0.01;secondary TR:r=0.806,P<0.01).Bland-Altman analysis showed that 3D VCA overestimated TR compared with 3D PISA EROA(62%overestimated in the total patient population,51%overestimated in primary TR,and 74%overestimated in secondary TR).In secondary TR,the cut-off value of 3D VCA for diagnosing severe TR was 0.45 cm2(sensitivity 89%,specificity 82%);combining clinical symptoms,positive 2D PISA EROA results and 3D VCA results for severe TR,the chi-square value was higher than those only included clinical symptoms or incorporated clinical symptoms and positive 2D PISA EROA results(42.168 vs.26.059 and 16.759,P<0.01).Conclusion 3D VCA would overestimate TR,and had high and incremental diagnostic value for evaluating severe TR in secondary TR.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail