1.Susceptibility Evaluation of EGFR Targeted Small Molecule NXGH/NXGF for Lung Cancer Cell
Yingying SUN ; Xilin SUN ; Kai WANG ; Fang FANG ; Baozhong SHEN
Progress in Modern Biomedicine 2017;17(27):5201-5205
Objective:To investigate the sensitivity of novel small molecule tyrosine kinase inhibitors NXGH and NXGF to 4 lung cancer cell lines with different EGFR expression and mutant status.Methods:Novel small molecule tyrosine kinase inhibitors NXGH and NXGF based on NXG structure were designed.Four lung cancer cell lines with different EGFR expression and mutation status:PC9(Exon 19 deletion mutation),H1975(L858R mutation combined T790M mutation),H358(wide EGFR expression) and H520(EGFR negative expression) were chosen.Inhibition ratio of NXGH and NXGF at different concentration (1.25,2.5,5.0,10,20,30,40,60,80 μmoL·L-1)against 4 lung cancer cell lines in 48 h were investigated by MTT method.IC50 and cell viability were calculated,and sensitivity between different cell lines were compared.Results:IC50 of PC9,H358,520 and H1975 cells incubated with NXGH were 0.675 μ moL·L-1,12.097 μmoL·L-1,11.368 μmoL·L-1 and 0.981 μmoL·L-1,respectively.IC50 of PC9 and H1975 were less than H358 and H520 when the concentration was 1.25,2.5 and 5 μmoL ·L-1 (P<0.05).IC50 of PC9,H358,H520 and H1975 cells incubated with NXGF were0.685 μmoL·L-1,4.265 μmoL·L-1,3.097 μmoL·L-1 and 0.331 μmoL·L-1,respectively.IC50 of PC9 and H1975 were less than H358 and H520 when the concentration was 1.25 and 5 μmoL·L-1 (P<0.05).Conclusion:The novel small molecule tyrosine kinase inhibitors NXGH and NXGF,which were designed and constructed in our laboratory successfully,had high affinity for lung cancer cells with different EGFR expression and mutation status.And they were more sensitive to EGFR mutant cell at low concentration as expected.
2.Molecular imaging and tumor targeted therapy
Xilin SUN ; Zhaoguo HAN ; Yongyi WU ; Baozhong SHEN
Chinese Journal of Clinical Oncology 2016;43(11):475-479
The abnormal expression (level and status) of the key molecular targets of tumors is related to molecular targeted therapy response, effect, and prognosis. Therefore, the expression level and status of key molecular targets of tumors must be accurately evalu-ated, regardless of the status before, during, and after receiving targeted therapy. Molecular imaging is a non-invasive method used for qualitative and quantitative research on key molecular targets of tumor in vivo and in real-time. This technique is also employed to screen treatment beneficiaries, guide therapy, and evaluate prognosis. This paper reviews the application progress of molecular imag-ing using various probes in cancer targeted therapy. The clinical value of molecular imaging in tumor targeted therapy is further ana-lyzed to promote the development of novel targeted therapy for tumors.
3.Minimally invasive and precise treatment of malignant tumor
Chinese Journal of Clinical Oncology 2016;43(11):452-456
The treatment of malignant tumor is one of the world's worst medical problem and is thus a research hotspot. The occur-rence of tumor development follows the molecule→cell→tissue→organ process. In theory, treatment can be achieved at any stage of tumor-growth by inhibition. Minimally invasive technology for treating tumor embodies the following direction of tumor treat-ment:minimally invasive, precise, and efficient. With endoscopy or imaging as a guide, the purpose of minimally invasive therapy is to have a small wound and to control tumor maximally at the tissue and organ level;thus, this therapy mode is the best and most pre-cise. This kind of technology has a good application prospect, even in the case of distant metastasis, and can be used to relieve the symptoms and improving the quality of survival by treating lesions affecting important organ functions. Minimally invasive therapy is a great challenge following the direction of modern medicine. With the development of medical science and technology, the important role of minimally invasive therapy in future tumor therapy is foreseen.
4.The relationship between the proliferation of parathyroid cell in rabbit with primary hyperparathyroidism and the bone mineral density
Xinmin LI ; Rongjie BAI ; Dong YAN ; Xiaoguang CHENG ; Hui QU ; Baozhong SHEN ; Mingjun HAN ; Zhenhua WU
Chinese Journal of Radiology 2011;45(9):870-873
ObjectiveTo evaluate the relationship between the proliferation of parathyroid cell in rabbit with primary hyperparathyroidism (PHPT) and the bone mineral density (BMD). MethodsEighty adult Chinese rabbits were randomly and equally divided into two groups. The contrast group was fed with normal diet ( Ca ∶ P, 1.0 ∶ 0. 7 ) and the experimental group was fed with high phosphate diet ( Ca ∶ P,1.0∶7.0) to establish the animal model of PHPT. At 3, 4, 5, and 6 months after the diet, bone mineral density of the rabbits was measured by the quantity CT (QCT). Then, the parathyroid and bone of the rabbits were removed for pathological examination. The number of parathyroid cell in PHPT was calculated.Proliferation was determined by immunohistochemistry of proliferation cell nuclear antigen ( PCNA ) and Bcl-2. The t test and Logistic regression was used to analyze the difference of data of two groups. ResultThe number of parathyroid cell in PHPT group was 1.61 times than that in the contrast group[ (673 ± 151 ) HP,(418 ± 25 ) HP,P <0. 01]. The rate of PCNA positive-cell was significantly increased in PHPT group than that in contrast group [(50.52 ± 11.62)%o, (26.70 ± 2. 78 )%, P < 0.01], and so was Bcl-2[ (460. 37 ± 190. 05 )‰, (67. 02 ±:4. 38 )%‰,P <0. 05]. The value of BMD was significantly decreased in PHPT group than that in contrast group [ ( 152. 5 ± 34. 3 ), ( 188.6 ± 12. 2 ) g/cm3, P < 0. 05]. There was a negative correlation between BMD and PCNA (r = -0. 749, P < 0. 05 ) and between BMD and Bcl-2 (r =-0.800, P < 0. 05 ) in PHPT group. ConclusionThe BMD of PHPT is related to the parathyroid cells proliferation which provide a reliable method for early diagnosis of PHPT.
5.Comparison of dual-source parallel radio frequence transmission liver MRI at 3.0 T with conventional MRI
Zhuren LUO ; Dan WANG ; Baozhong SHEN ; Xilin SUN ; Guokun WANG ; Fang LIU ; Shuguang HU ; Chan QUEENIE
Chinese Journal of Radiology 2011;45(11):1032-1035
Objective To investigate the role of dual-source parallel radio frequence (RF) and single-source excitation in liver imaging at 3.0 T MR.Methods This study was a retrospective analysis.One hundred and seven subjects underwent a 3.0 T TX MR scanning including axial spectrally selective attenuated inversion recovery (SPAIR) T2WI,axial DWI and coronal balanced-fast field echo( Balanced FFE).Each sequence was carried out with both single-source and dual-source RF excitation.Student's t test was used to compare the differences between single-source and dual-source RF excitation in the image uniformity,signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR).Wilcoxon signed rank test was used to determine whether there was difference between conventional and parallel transmission in the score of image quality.Reader agreement was assessed using the Cohen's Kappa test.Results For the image uniformity,there was significant difference between single-source and dual-source excitation (418.40 ± 66.75 for single-source vs.416.26 ± 50.61 for dual-source,t =2.524,P < 0.05 ).There also existed significant difference between single-source and dual-source excitation in SNR and CNR,respectively.The SNR and CNR of parallel transmission (22.03 + 12.16 and 18.33 ± 10.01,respectively) were both higher than those of single transmission (20.36 ± 11.21 and 15.22 ± 8.95,respectively) ( t =- 2.630,P < 0.05 for SNR and t =- 4.238,P < 0.05 for CNR).Image quality comparisons revealed significantly better results with dual-source than single-source RF excitation at SPAIR T2 WI ( 1.40 + 0.42 vs.1.81 ± 0.27 ),DWI ( 1.08 ± 0.40 vs.1.63 ± 0.36 ) and Balanced FFE sequence ( 0.95 ± 0.45 vs.1.65 ± 0.37,Z =- 5.894,- 5.801 and - 6.985,respectively,P < 0.01 ).In the comparison of image quality,the agreement between the two readers was very good ( Kappa > 0.8,P < 0.05 ).Conclusion Dual-source parallel RF excitation MR imaging in liver enables reducing dielectric shading,improving homogeneity of the RF magnetic induction field,and increasing SNR and CNR at 3.0 T.
6.A comparative study of 99Tcm N-mercaptopyridine-N-oxide and 99Tcm-sestamibi myocardial perfusion imaging on acute myocardial infarction canine model
Fei SHA ; Xiaofei WEN ; Lihong BU ; Renfei LI ; Tong ZHANG ; Zhongnan JIN ; Baozhong SHEN
Chinese Journal of Radiology 2011;45(4):392-398
Objective The purpose of the present study is to compare the pharmacokinetic and biodistribution properties of 99Tcm N-mercaptopyridine-N-oxide (99 Tcm N-MPO) with 99 Tcm-sestamibi (99 Tcm-MIBI) in normal dogs, and to investigate the potential of 99TcmN-MPO as a myocardial perfusion agent in canines with acute myocardial infarction. Methods Twelve healthy mongrel dogs were injected intravenously with 99TcmN-MPO (n = 6) or 99Tcm-MIBI (n = 6). Tracer kinetics in body fluids were determined by collecting blood of 1 ml via a femoral vein catheter at 30 s, 1,2,3,4,5, 10, 20, 30, 40, 60and 90 min post-injection (p. i.). The collected blood samples were weighed and counted for radioactivity in a γ-counter. Anterior and posterior planar γ-camera images were collected at 10, 20, 30, 60, 90, and 120 min after injection, with organ uptake quantified by region-of-interest (ROIs) analysis. For comparison, 99Tcm-MIBI was also evaluated in the same twelve dogs. Canine infarct models were set up by micro-invasive interventional embolization. SPECT images in the canine infarct model were collected 24 hours after myocardial infarction at 30 min and 60 min after the administration of 99Tcm N-MPO (n = 5) or 99Tcm-MIBI (n = 5). Results Both of 99Tcm N-MPO and 99Tcm-M1BI had a rapid blood clearance with less than 50% of initial radioactivity remaining at 1 min [99TcmN-MPO: (35. 77 ± 6. 31)% ID/mg ,99Tcm-MIBI (34. 46 ± 6. 83) % ID/mg] and less than 5% at 30 min p. i. [99Tcm N-MPO(3. 11 ± 1.44) % ID/mg,99Tcm-MIBI (2.93 ±0. 39)% ID/mg] . After injection, 99TcmN-MPO showed significant accumulation in the myocardium and prolonged retention. This rapid liver clearance of 99TcmN-MPO led to favorable heart-to-liver ratios, reaching values of 0. 54 ±0. 06 at 10 min, 1.02 ±0. 06 at 30 min, and 1.38 ±0. 06 at 60 min p. i.In contrast, the heart/liver ratio of 99Tcm-MIBI remained low at all time points (0. 46 ± 0. 03 at 10 min,0. 63 ±0. 03 at 30 min, and 0. 62 ± 0. 12 at 60 min p. i.). SPECT imaging studies in canines with acute myocardial infarction indicated that good visualization of the left ventricular wall and perfusion defects could be achieved at 30 min after administration of 99TcmN-MPO, but not 99Tcm-MIBI. Conclusion The combination of high heart uptake and rapid liver clearance makes 99TcmN-MPO a promising new radiotracer for myocardial perfusion imaging.
7.Molecular imaging of human breast cancer xenografts in nude mice by epidermal growth factor labelled by near infrared fluorescent dye
Kezheng WANG ; Baozhong SHEN ; Weihua LI ; Kai WANG ; Tao HUANG ; Lihong BU ; Dan WANG ; Renfei LI ; Zhifei WANG ; Yuyan MA ; Hongfei JI ; Bo WANG ; Yue YANG
Chinese Journal of Radiology 2009;43(8):872-877
can specifically combined with EGFR, which may be applied to noninvasive NIRF imaging of tumors highly expressed EGFR in vivo.
8.Clinical application of MR susceptibility weighted imaging in intracranial hemorrhage
Baozhong SHEN ; Dan WANG ; Xilin SUN ; Hao SHEN ; Fang LIU
Chinese Journal of Radiology 2009;43(2):156-160
Objective To assess the value of susceptibility weighted imaging(SWI) in the diagnosis of intracranial hemorrhage. Methods Forty patients with intracranial hemorrhage underwent MRI scanning (GE Signa HDe 1.5 T), which included T2WI, T1WI, T2 * WI and SWI. Of them, DWI was conducted in 37 cases and enhanced MRI was conducted in 10 cases additionally. After post processing on the workstation, both magnitude and phase images of SWI were acquired for further analysis. The images of all sequences were scored from 1 to 3, according to their ability of depicting the lesions. Statistical analysis was conducted to compare the scores among these sequences. Results On SWI, the scores in detecting the lesions, their margin and adjacent veins were 2. 8, 2. 8, and 2. 8 respectively. The scores of those were 1.8, 1.7,and 0.0 on T1WI, 2.3, 2.0 and 0.0 on T2WI, 2.0, 2.1 and 0.2 on T2* WI, respectively. There was statistical difference between the scores on SWI and those on T1WI, T2 WI and T2 * WI ( P < 0. 01 ). The numbers of micro hemorrhagic lesions that could be observed on SWI, T1WI, T2WI, DWI and T2 *WI were 402, 55, 61, 84 and 188 respectively. There was statistical difference in showing micro hemorrhagic lesions between SWI and T1WI, T2WI, DWI, T2 * WI (P < 0. 01 ). Conclusion SWI is sensitive to visualize the hemorrhagic region, and has predominant advantage over conventional MR sequences including T2 * WI in detecting intracranial hemorrhage, especially cerebral microbleeding. According to the features of the paramagnetic and diamagnetic lesions, radiologists can differentiate hemorrhage and calcification with phase images.
9.Evaluation of effects of simvastatin on vascular elasticity in fat-fed rabbits by echo-tracking technique
Li XU ; Baozhong SHEN ; Shijia YU ; Tiemei SHI
Chinese Journal of Ultrasonography 2008;17(12):1072-1075
Objective To evaluate the effects of simvastatin on the vascular elasticitv in fat-fed rabbits by echo-tracking(ET)technique.Methods Twenty seven rabbits were divided randomly into 3 groups:normal control group(group A),high fat diet group(group B),simvastatin group(group C:high fat diet for the 1st 4 weeks and high fat diet+simvastatin for the 2nd 4 weeks).β,EP,AC,and PWVβof abdominal aorta (AO) and femoral artery(FA)of rabbits in group A、B、C were measured by ET technique at the end of 4th week and 8th week respectively.The expression of iNOS was measured at the end of 8th week.Results At the end of the 4th week,β,Ep,and PWVβ of FA were significantly inereased and AC was significantly decreased in group B compared to those in group A(P<0.05).At the end of the 8th week,β,Ep,PWVβof AO were significantly increased and AC was significantly decreased in group B compared to those in group A(P<0.05);β,Ep,PWVβ of FA were statistically decreased and AC was statistically increased in group C compared to those in group B(P<0.05),however there was no significant difference of AO between groups B and C.Conclusions Short-term administration of simvastatin can improve the elasticity of some muscular arteries such as FA but not AO.
10.64-detector Helical CT in Diagnosis of Coronary Heart Disease
Tong ZHANG ; Wei WANG ; Baozhong SHEN
Journal of Practical Radiology 2001;0(08):-
Objective To investigate the accuracy of 64-detector helical CT in assessing stenoses of coronary arteries. Methods 64-detector helical CT angiography was performed in 128 patients with suspected coronary artery disease,and the results were compared with that of invasive coronary angiography. Results Among 128 patients, 1 724 of 1 920 coronary artery segments were assessable (90%). Overall sensitivity for classifying stenoses was 92%, specificity was 94%, positive predictive value was 82%, and negative predictive value was 96%.Conclusion 64-detector helical CT provides a high diagnostic accuracy in assessing coronary artery stenoses.

Result Analysis
Print
Save
E-mail