1.Nanoparticles (NPs)-mediated Siglec15 silencing and macrophage repolarization for enhanced cancer immunotherapy.
Xiaodi LIU ; Qi ZHANG ; Yixia LIANG ; Shiyu XIONG ; Yan CAI ; Jincheng CAO ; Yanni XU ; Xiaolin XU ; Ye WU ; Qiang LU ; Xiaoding XU ; Baoming LUO
Acta Pharmaceutica Sinica B 2023;13(12):5048-5059
T cell infiltration and proliferation in tumor tissues are the main factors that significantly affect the therapeutic outcomes of cancer immunotherapy. Emerging evidence has shown that interferon-gamma (IFNγ) could enhance CXCL9 secretion from macrophages to recruit T cells, but Siglec15 expressed on TAMs can attenuate T cell proliferation. Therefore, targeted regulation of macrophage function could be a promising strategy to enhance cancer immunotherapy via concurrently promoting the infiltration and proliferation of T cells in tumor tissues. We herein developed reduction-responsive nanoparticles (NPs) made with poly (disulfide amide) (PDSA) and lipid-poly (ethylene glycol) (lipid-PEG) for systemic delivery of Siglec15 siRNA (siSiglec15) and IFNγ for enhanced cancer immunotherapy. After intravenous administration, these cargo-loaded could highly accumulate in the tumor tissues and be efficiently internalized by tumor-associated macrophages (TAMs). With the highly concentrated glutathione (GSH) in the cytoplasm to destroy the nanostructure, the loaded IFNγ and siSiglec15 could be rapidly released, which could respectively repolarize macrophage phenotype to enhance CXCL9 secretion for T cell infiltration and silence Siglec15 expression to promote T cell proliferation, leading to significant inhibition of hepatocellular carcinoma (HCC) growth when combining with the immune checkpoint inhibitor. The strategy developed herein could be used as an effective tool to enhance cancer immunotherapy.
2.Correlation analysis of contrast-enhanced ultrasound Liver Imaging Reporting and Data System classification with hepatocellular carcinoma differentiation and Ki-67 index
Suwan CHAI ; Wenjia CAI ; Jie YU ; Rongqin ZHENG ; Jintang LIAO ; Baoming LUO ; Lina TANG ; Ping LIANG
Chinese Journal of Ultrasonography 2023;32(5):386-391
Objective:To investigate the correlation of hepatocellular carcinoma (HCC) classified by contrast-enhanced ultrasound (CEUS) Liver Imaging Data and Report System (LI-RADS) with differentiation degree and Ki-67 index.Methods:A multicenter, retrospective study was conducted.The clinical and CEUS imaging data of 208 patients with 208 HCC lesions from December 2017 to December 2020 in China CEUS database were included and analyzed. According to the CEUS LI-RADS version 2017 proposed by the American College of Radiology, the HCC was classified. The diagnosis and pathological information of all lesions were confirmed by pathology. The differentiation degree of HCC and the distribution of Ki-67 index in different LI-RADS categories were evaluated, and their correlation was analyzed.Results:The degree of differentiation and Ki-67 index among HCC of different CEUS LI-RADS were statistically significant ( P<0.001, P=0.009). LI-RADS M HCC was more likely to be poorly differentiated and showed a higher Ki-67 index. The category of LI-RADS was positively correlated with the degree of tumor differentiation (tau-b=-0.250, P<0.001) and the Ki-67 index (tau-b=0.178, P=0.002), that is, the higher the category of LI-RADS, the lower differentiation degree and the higher the Ki-67. Conclusions:The CEUS LI-RADS classification of HCC is correlating with the degree of differentiation and Ki-67 index.
3.A multicenter study to confirm further diagnostic value of strain ratio method giving to 5-point scoring by elastography for differentiation of breast lesions
Bing OU ; Jiayi WU ; Xinchuan ZHOU ; Jiyi YAO ; Ming LIANG ; Baoming LUO ; Hui ZHI ; Yulan PENG ; Parajuly Sundar SHYAM
Chinese Journal of Ultrasonography 2017;26(10):867-871
Objective To confirm whether strain ratio should be added after evaluation of lesions with 5-point elasticity scoring for differentiating breast lesions on ultrasonic elastography(UE).Methods Eight hundred and forty-six consecutive female patients with 1 071 breast lesions were recruited into a multicenter retrospective study,which involved 8 centers across China.All the patients underwent the UE procedure and the strain ratios were calculated.The sensitivity,specificity,accuracy,PPV and NPV were calculated for each of the two evaluation systems and the areas under the ROC curve were compared.Results The strain ratios of 559 benign lesions(2.7±1.4)and 512 malignant lesions(8.1±5.9)were significantly different (P<0.001).When the cutoff point was 3.03,strain ratio method had 81.6% sensitivity,89.7% specificity,81.7% accuracy,80.2% PPV and 84.2% NPV.The areas under the ROC curve with the strain ratio method and 5-point scoring method were 0.865 and 0.862,respectively(P =0.622).For the lesions with elasticity score 3 and 4,the areas under the ROC curve of the two Methods were 0.71 1 and 0.629, respectively(P = 0.020).Conclusions Although the two UE Methods have similar diagnostic performance,separate calculation of the strain ratios seems compulsory,especially for the lesions with elasticity score 3 and 4.
4.Comparative study of superb microvascular imaging and contrast-enhanced ultrasonographic microvascular imaging in diagnosis of breast tumor
Xin CHEN ; Baoming LUO ; Xiaofeng GUAN ; Huan WU ; Xiaoyun XIAO
Chinese Journal of Ultrasonography 2016;25(7):608-611
Objective To compare the diagnostic efficiency of superb microvascular imaging (SMI) and contrast-enhanced ultrasonographic microvascular imaging (MVI) for differentiating breast lesions.Methods One hundred and sixteen patients with 116 breast lesions were first examined by grayscale ultrasound.Then SMI and MVI were performed on all patients.Microvascular architectures of breast lesions were depicted by both methods.The lesions were evaluated based on their microvascular architectures.The diagnostic efficacy of both methods were compared.Results The diagnostic sensitivity,specificity,and accuracy of SMI and MVI were 79.24%,90.48 %,85.35% and 88.68%,87.30%,87.93%,respectively.The areas under the curve of SMI and MVI were 0.888 and 0.926.The diagnostic values of SMI and MVI were not statistically different (P =0.212).Conclusions SMI can detect tiny vessels and depict microvascular architecture of breast lesions as MVI do,which is beneficial for breast tumor differentiation.The diagnostic efficacy of SMI is almost the same as MVI.
5.Comparison of Contrast-enhanced Ultrasound, Contrast-enhanced CT and Contrast-enhanced MRI in the Diagnosis of Renal Space-occupying Lesions
Zhi ZHANG ; Zizhuo ZHAO ; Jingliang RUAN ; Jing TIAN ; Baoming LUO
Chinese Journal of Medical Imaging 2014;(10):764-767
Purpose To compare the value of contrast-enhanced ultrasound (CEUS), contrast-enhanced CT (CECT) and contrast-enhanced MRI (CEMRI) in the diagnosis of renal space-occupying lesions. Materials and Methods Seventy-eight patients whose 80 kidney space-occupying lesions were conifrmed by traditional ultrasound underwent CEUS examination. Among those patients, 39 patients also underwent CECT, 28 had CEMRI, and 5 had CECT and CEMRI examination together. Taken pathologic findings as gold standard, the value of conventional ultrasound, CEUS, CECT and CEMRI was compared in the diagnosis of renal space-occupying lesions. Results Among 80 renal masses, 57 lesions were malignant and the rest 23 lesions were benign. The diagnostic sensitivity, speciifcity, positive predictive value and negative predictive value were 93.0%, 69.6%, 88.3%, 80.0%for CEUS;those for CECT were 96.4%, 72.7%, 90.0%, 88.9%respectively;and for CEMRI were 86.4%, 66.7%, 90.5%, 57.1%respectively;and the diagnostic value among the three means showed no difference (P>0.05). Conclusion CEUS, CECT and CEMRI are all effective in the diagnosis of renal space-occupying lesions, We may select suitable examination means for patients according to their features. A combination of these techniques provides more information for the diagnosis of renal space-occupying lesions.
6.Diagnostic value of sound velocity and real-time ultrasonic elastographpy in differentiation benign or malignant of breast lesions
Bing OU ; Hui ZHI ; Haiyun YANG ; Baoming LUO
Chinese Journal of Ultrasonography 2013;(1):59-62
Objective To compare the diagnostic value of sound velocity(SV) and real-time ultrasonic elastography in differentiating benign or malignant of breast lesions.Methods 75 patients with 99 lesions were examined with the zone speed index technique and real-time ultrasonic elastography respectively.Then the SVs of the lesions were calculated and elastography of the lesions were scored with 5-scoring method.The ROC curves were constructed with histology as the golden standard.Results There was significant difference between the SVs of benign and malignant breast lesions(P =0.0001).1561 m/s was the best cufoff point.And the areas under the curves (AUC) of SV and real-time ultrasonic elastography were 0.842 and 0.968,respectively.There was significant difference between the two methods of AUC (P =0.023).The sensitivity,specificity and accuracy for SV were 81.5%,91.7%,88.9%,respectively.There was no significant difference between sensitivity,specificity and accuracy of the two methods(P =1.0,P =0.125,P =0.146).Conclusions Both SV method and real-time ultrasonic elastography are helpful in the evaluation of benign or malignant of breast lesions.
7.Ultrasound image evaluation for nuchal translucency based on image recognition
Hong DING ; Yong ZHANG ; Yunhui WANG ; Zhenhua WANG ; Baoming LUO
Chinese Journal of Ultrasonography 2013;22(11):977-980
Objective To establish the model and software for quality assessment of fetal nuchal translucency ultrasound image using computer image recognition technology.Methods The proposed approach firstly divided the input image into four sub-image blocks:the nasal bone(NB) area,the nuchal translucency (NT) area,the midbrain area,and the jaw and chest area.For each sub-image block,the algorithm compared the image block with the corresponding area of the standard training image set,and then determined whether the current image block was the qualified one using the the Gabor feature and Bayesian decision.The input ultrasound image was determined to be qualified only if it had four qualified sub-image blocks.Results The difference between our automatic method and the manual screening by experts wasting small,the method obtained Kappa =0.795 and P <0.001.Moreover,the efficiency of our method was much higher than the manual screening method.Conclusions Image recognition technology can effectively assist the sonographer to assess the quality of fetal NT of ultrasound image.The proposed approach can reduce the subjectivity and randomness of the manual evaluation of NT image.
8.Value of contrast-enhanced ultrasonography in diagnosis typing of placenta accrete
Hong DING ; Baoming LUO ; Yunhui WANG ; Xuedan JIAO
Chinese Journal of Ultrasonography 2013;(4):337-339
Objective To assess the value of contrast enhanced ultrasound (CEUS) in diagnosing subtypes of postpartum placenta accreta.Methods 31 puerperal clinically diagnosed of postpartum placenta accreta were collected.They were inspected by using CEUS and 2-dimensional color Doppler ultrasound,respectively.The operation was used as a reference.Results Both 2-dimensional color Doppler and CEUS could identify the sizes of residual placenta for the patients,but CEUS showed more explicit boundary for placenta and uterus and the rich/poor blood flow areas in the placenta.Among the 31 patients,7,23 and 1 were classified of accreta,increta and percreta,respectively,by using 2-dimensional color Doppler ultrasound,while 11,16 and 4 were classified of accreta,increta and percreta,respectively,by using CEUS based on the myometrial thickness and contrast agent subsided time.With respect to operation,10 patients were confirmed of accrete,with the other diagnosed of increta and percreta.The misclassification rate of 2-dimensional color Doppler ultrasound was 19.6 %,while CEUS had only 6.5 %.CEUS had a good agreement with operation (Kappa =0.859,P < 0.001).Conclusions CEUS has higher accuracy in diagnosing subtypes of postpartum placenta accrete compared with 2-dimensional color Doppler ultrasound.CEUS can increase the accuracy and reliability for diagnosing those who were clinically considered of postpartum placenta accrete,and can provide helpful guidelines for clinical treatment.
9.Initial study of contrast-enhanced ultrasound 5-point scoring system in the diagnosis of breast tumor
Xiaoyun XIAO ; Hui ZHI ; Haiyun YANG ; Huan WU ; Baoming LUO
Chinese Journal of Ultrasonography 2012;21(4):328-331
Objective To explore the application of contrast-enhanced scoring system in the diagnosis of breast tumor.Methods 249 patients with 260 lesions were examined by elastography and contrastenhanced ultrasound before surgery.All the lesions were scored according to the two different methods.Pathological results were made the golden criteria.The diagnosis accuracy of the two methods were compared.Results There were 145 benign and 115 malignant tumors.The diagnosis accuracy,specificity and sensibility of elastography were 85.0%,88.3%,80.1 % respectively.The critical value of contrastenhanced ultrasound was between 3 and 4.The diagnosis accuracy,specificity and sensibility of contrastenhanced ultrasound were 88.9%,87.6%,90.4% respectively.Area under ROC curve of the two methods were 0.901 and 0.910,the difference was not statistically significant.Conclusions Contrast-enhanced ultrasound 5-point scoring system was an initial quantitative criterion for breast tumor diagnosis.The diagnosis accuracy was parallel to that of elastography.
10.Diagnostic value of ultrasonic elastography and conventional ultrasound in differentiating the benign and malignant hepatic tumors
Xinchuan ZHOU ; Hui ZHI ; Xiaoyun XIAO ; Baoming LUO
Chinese Journal of Ultrasonography 2011;20(11):950-952
Objective To evaluate the diagnostic value of conventional ultrasound and ultrasonic elastography (UE) in differentiating benign and malignant hepatic lesions.Methods One hundred and forty-five patients with 159 hepatic tumors were included in the study.Conventional ultrasound scan and UE were performed on each patient.Pathological results were as the golden standard.The diagnostic performance of the 2 methods were evaluated with receiver operating characteristic (ROC) curves and the interobserver agreements were analysed.Results A better interobserver agreement was achieved in UE (κ =0.325 at conventional ultrasound versus κ =0.782 at UE).The area under ROC curve of conventional ultrasound,ultrasonic elastography and the combination of both methods were 0.76,0.77 and 0.87,respectively.After the combination of the 2 methods,the sensitivity and accuracy could be enhanced significantly ( P <0.05).Conclusions Conventional ultrasound combined with UE may be more helpful in differentiating malignant from benign hepatic tumors.

Result Analysis
Print
Save
E-mail