1.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
		                        		
		                        			 Objective:
		                        			This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).  
		                        		
		                        			Methods:
		                        			The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.  
		                        		
		                        			Results:
		                        			The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.  
		                        		
		                        			Conclusions
		                        			Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability. 
		                        		
		                        		
		                        		
		                        	
2.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
		                        		
		                        			 Objective:
		                        			This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).  
		                        		
		                        			Methods:
		                        			The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.  
		                        		
		                        			Results:
		                        			The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.  
		                        		
		                        			Conclusions
		                        			Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability. 
		                        		
		                        		
		                        		
		                        	
3.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
		                        		
		                        			 Objective:
		                        			This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).  
		                        		
		                        			Methods:
		                        			The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.  
		                        		
		                        			Results:
		                        			The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.  
		                        		
		                        			Conclusions
		                        			Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability. 
		                        		
		                        		
		                        		
		                        	
4.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
		                        		
		                        			 Objective:
		                        			This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).  
		                        		
		                        			Methods:
		                        			The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.  
		                        		
		                        			Results:
		                        			The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.  
		                        		
		                        			Conclusions
		                        			Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability. 
		                        		
		                        		
		                        		
		                        	
5.Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Jong-Chan BAIK ; Youn-Kyung CHOI ; Yonghun CHO ; Yunju BAEK ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Ki Beom KIM ; Yong-Il KIM
The Korean Journal of Orthodontics 2024;54(6):359-373
		                        		
		                        			 Objective:
		                        			This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).  
		                        		
		                        			Methods:
		                        			The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/ moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width.The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.  
		                        		
		                        			Results:
		                        			The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.  
		                        		
		                        			Conclusions
		                        			Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability. 
		                        		
		                        		
		                        		
		                        	
6.Healthcare reform: let science, not politics, lead the way
Nayoung KIM ; Ji Eun PARK ; Hyun Jung KOO ; Sarah CHAY ; Soo-Youn HAM ; So Yeon KIM ; Ji-Young SUL ; Soon Won HONG ; Hyun Wook BAIK
Annals of Coloproctology 2024;40(Suppl 1):S48-S49
		                        		
		                        		
		                        		
		                        	
7.The Effect of Tegoprazan on the Treatment of Endoscopic Resection-Induced Artificial Ulcers: A Multicenter, Randomized, Active-Controlled Study
Byung-Wook KIM ; Jong Jae PARK ; Hee Seok MOON ; Wan Sik LEE ; Ki-Nam SHIM ; Gwang Ho BAIK ; Yun Jeong LIM ; Hang Lak LEE ; Young Hoon YOUN ; Jun Chul PARK ; In-Kyung SUNG ; Hyunsoo CHUNG ; Jeong Seop MOON ; Gwang Ha KIM ; Su Jin HONG ; Hyuk Soon CHOI
Gut and Liver 2024;18(2):257-264
		                        		
		                        			 Background/Aims:
		                        			Tegoprazan is a novel potassium-competitive acid blocker that has beneficial effects on acid-related disorders such as gastroesophageal reflux and peptic ulcer diseases.This study aimed to validate the effect of tegoprazan on endoscopic submucosal dissection (ESD)-induced artificial ulcers. 
		                        		
		                        			Methods:
		                        			Patients from 16 centers in Korea who underwent ESD for gastric neoplasia were enrolled. After ESD, pantoprazole was administered intravenously for 48 hours. The patients were randomly allocated to either the tegoprazan or esomeprazole group. Tegoprazan 50 mg or esomeprazole 40 mg were administered for 4 weeks, after which gastroscopic evaluation was performed. If the artificial ulcer had not healed, the same dose of tegoprazan or esomeprazole was administered for an additional 4 weeks, and a gastroscopic evaluation was performed. 
		                        		
		                        			Results:
		                        			One hundred sixty patients were enrolled in this study. The healing rates of artificial ulcers at 4 weeks were 30.3% (23/76) and 22.1% (15/68) in the tegoprazan and esomeprazole groups, respectively (p=0.006). At 8 weeks after ESD, the cumulative ulcer healing rates were 73.7% (56/76) and 77.9% (53/68) in the tegoprazan and esomeprazole groups, respectively (p=0.210). Delayed bleeding occurred in two patients in the tegoprazan group (2.6%) and in one patient in the esomeprazole group (1.5%). Other adverse events were negligible in both groups. 
		                        		
		                        			Conclusions
		                        			Tegoprazan showed similar effects on post-ESD artificial ulcer healing in comparison with esomeprazole. 
		                        		
		                        		
		                        		
		                        	
8.Evaluating the Validity and Reliability of the Korean Version of the Scales for Outcomes in Parkinson’s Disease–Cognition
Jinse PARK ; Eungseok OH ; Seong-Beom KOH ; In-Uk SONG ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Yoon-Joong KIM ; Jin Whan CHO ; Hyeo-Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Jee-Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung KIM ; Jinyoung YOUN ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Joong-Seok KIM ; Ji-Young KIM
Journal of Movement Disorders 2024;17(3):328-332
		                        		
		                        			 Objective:
		                        			The Scales for Outcomes in Parkinson’s Disease–Cognition (SCOPA-Cog) was developed to assess cognition in patients with Parkinson’s disease (PD). In this study, we aimed to evaluate the validity and reliability of the Korean version of the SCOPACog (K-SCOPA-Cog). 
		                        		
		                        			Methods:
		                        			We enrolled 129 PD patients with movement disorders from 31 clinics in South Korea. The original version of the SCOPA-Cog was translated into Korean using the translation-retranslation method. The test–retest method with an intraclass correlation coefficient (ICC) and Cronbach’s alpha coefficient were used to assess reliability. Spearman’s rank correlation analysis with the Montreal Cognitive Assessment-Korean version (MOCA-K) and the Korean Mini-Mental State Examination (K-MMSE) were used to assess concurrent validity. 
		                        		
		                        			Results:
		                        			The Cronbach’s alpha coefficient was 0.797, and the ICC was 0.887. Spearman’s rank correlation analysis revealed a significant correlation with the K-MMSE and MOCA-K scores (r = 0.546 and r = 0.683, respectively). 
		                        		
		                        			Conclusion
		                        			Our results demonstrate that the K-SCOPA-Cog has good reliability and validity. 
		                        		
		                        		
		                        		
		                        	
9.Parenting Experience of Shift Nurses With Elementary School-Aged Children During the COVID-19 Pandemic: A Phenomenological Study
Jeung-Im KIM ; Mi-Youn JANG ; A-Ri SONG ; Jung-Eun YU ; Myung-Sook BAIK
Journal of the Korean Society of Maternal and Child Health 2023;27(3):154-166
		                        		
		                        			 Purpose:
		                        			This phenomenological study aimed to comprehend the altered parenting experience of nurses during the coronavirus disease 2019 (COVID-19) pandemic.Method: Using a qualitative approach, the research design employed a phenomenological methodology. The participants were 6 nurses with elementary school-aged children. The nurses were employed in tertiary general hospitals, working on rotating shifts during the COVID-19 pandemic. In-depth interviews were conducted to collect individual data, which were then analyzed using Colaizzi phenomenological method. 
		                        		
		                        			Results:
		                        			Analyzing the collected data led to 178 significant results, from which 13 themes were derived. These 13 themes were further integrated into 5 distinct theme clusters: (1) struggling as a nurse-mom, (2) providing a supportive presence, (3) facing challenges in facilitating children's learning activities, (4) navigating parental roles in a chaotic situation, and (5) pursuing physical safety. These clusters were subsequently categorized into four overarching categories: “suffering,” which encompassed the themes of pressure of infection and providing a supportive presence, as well as “controlling,” “parenting,” and “seeking,” representing the remaining clusters, respectively. 
		                        		
		                        			Conclusion
		                        			The parenting experiences of shift nurses during the COVID-19 pandemic encompassed various aspects, including the challenges posed by the pressure of infection, the importance of providing a supportive presence, difficulties in managing children’s learning activities, navigating parental roles amid chaotic circumstances, and the pursuit of physical safety. These experiences significantly impact the stability of shift nurses’ caregiving abilities for both their patients and their children. Therefore, it is crucial to establish a comprehensive nationallevel care support system in times of disaster situations like the COVID-19 pandemic. 
		                        		
		                        		
		                        		
		                        	
10.Comparison of In Vivo Three-Dimensional Glenohumeral Positions and Scapular Kinematics between Young and Older Male Groups
Ki Youn KWON ; Doo Sup KIM ; Seung Hoon BAIK ; Jin Woo LEE
Clinics in Orthopedic Surgery 2021;13(3):376-384
		                        		
		                        			Background:
		                        			Many researchers have questioned whether shoulder kinematics such as the glenohumeral position and scapular kinematics would be different in different age groups. However, studies comparing shoulder kinematics between different age groups have been rare. The aim of this study was to analyze and compare the three-dimensional (3D) glenohumeral position, scapular kinematics, and scapulohumeral rhythm (SHR) during scapular plane arm abduction between a normal young male group and a normal older male group. 
		                        		
		                        			Methods:
		                        			Twenty normal men (10 young and 10 older) were enrolled in this controlled laboratory study. Fluoroscopic images were obtained using a single plane X-ray system. Bilateral computed tomography scans were taken to create a 3D model. A 3D-2D registration technique was used to determine the 3D position and orientation of the bones of the shoulder. 
		                        		
		                        			Results:
		                        			During scapular plane arm abduction, there were significant differences in scapular kinematics between the groups. The older male group showed more upward rotation, posterior tilt, and external rotation than the young male group. On the other hand, the glenohumeral position such as superior inferior translation, anterior posterior translation, and external rotation of the humeral head did not show significant difference between the groups. The mean value of SHR for the overall arm elevation range from start to maximum elevation angle for the older group and young group was 2.298 ± 0.964 and 2.622 ± 0.931, respectively, showing a significant difference between the two groups (p = 0.035). 
		                        		
		                        			Conclusions
		                        			Scapular kinematics and SHR were significantly different between the older male group and the young male group. Our study could provide reference values of shoulder kinematics for older men aged 55–65 years.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail